MPD MA124D15RU Ma100ru sery Datasheet

MA100RU Series
Wide 4:1 Input, 1.5W,
Single & Dual Output
DC/DC Converters
Electrical Specifications
Key Features:
• 1.5W Output Power
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
• 4:1 Input Voltage Range
• 1,500 VDC Isolation
Input Voltage Range
• 20 Standard Models
Input Reflected Ripple Current
• High Efficiency
Input Filter
• Compact DIP Case
Output
• -40°C to +85°C Operation
Parameter
• Metal Case Available
• Low Cost
Alternate
Pin-Out
Available
Min.
Typ.
Max.
24 VDC Input
9.0
24.0
36.0
48 VDC Input
18.0
48.0
72.0
35
VDC
mA P - P
(Pi) Filter
Conditions
Min.
Output Voltage Accuracy
Line Regulation
Typ.
Max.
Units
±1.0
%
VIN = Min to Max
±0.5
%
%
IOUT = 25% to 100%
±0.5
Cross Regulation
See Note 1
±0.5
%
Ripple & Noise (20 MHz)
See Note 2
60
mV P - P
±0.02
%/°C
Load Regulation
Temperature Coefficient
Output Short Circuit
Continuous (Autorecovery)
General
Parameter
Conditions
Isolation Voltage, See Note 3
1.5 kV Isolation
Models
Available
Units
Isolation Resistance
Isolation Capacitance
Min.
3 Seconds
1,500
500 VDC
1,000
100 kHz/0.1V
Switching Frequency
Typ.
Max.
Units
VDC
M
60
100
pF
400
kHz
Environmental
Parameter
Conditions
Operating Temperature Range
Ambient
Operating Temperature Range
Min.
Typ.
Max.
Units
-40
+25
+85
°C
+100
°C
+125
°C
95
%
Case
Storage Temperature Range
-40
Cooling
Free Air Convection
Humidity
RH, Non-condensing
Physical
Case Size
1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm)
Case Material, Plastic
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Non-Conductive Black Plastic (UL94-V0)
Weight, Plastic Case
0.44 Oz (12.5g)
Case Material, Metal
Nickel-Coated Copper With Non-Conductive Base (UL94-V0)
Weight, Metal Case
0.53 Oz (15g)
Reliability Specifications
Parameter
Conditions
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
Min.
Typ.
Max.
1.0
Units
MHours
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Min.
Typ.
Max.
24 VDC Input
-0.7
40.0
48 VDC Input
-0.7
80.0
1.5 mm From Case for 10 Sec
260
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Output
Current (mA)
Efficiency
Voltage
Current
Current
(VDC)
(mA, Max)
(mA, Min)
Full-Load No-Load
(%, Typ)
Fuse
Reflected Capacitive
Ripple
Rating
Load
Current
Slow-Blow
(µF, Max)
(mA Typ)
(mA)
Nominal
Range
MA124S-05RU-xx
24
9.0 - 36.0
91.0
20
MA124S-09RU-xx
24
9.0 - 36.0
89.0
20
9.0
167.0
55.7
70
35.0
470
200
MA124S-12RU-xx
24
9.0 - 36.0
86.0
20
12.0
125.0
41.7
72
35.0
470
200
MA124S-15RU-xx
24
9.0 - 36.0
86.0
20
15.0
100.0
33.3
72
35.0
470
200
MA124S-24RU-xx
24
9.0 - 36.0
88.0
30
24.0
62.5
20.8
71
35.0
220
200
MA124D-05RU-xx
24
9.0 - 36.0
94.0
20
±5.0
±150.0
±50.0
66
35.0
±1,000
200
MA124D-09RU-xx
24
9.0 - 36.0
91.0
20
±9.0
±83.3
±27.8
68
35.0
±220
200
MA124D-12RU-xx
24
9.0 - 36.0
89.0
20
±12.0
±62.5
±20.8
70
35.0
±220
200
MA124D-15RU-xx
24
9.0 - 36.0
89.0
20
±15.0
±50.0
±16.7
70
35.0
±220
200
MA124D-24RU-xx
24
9.0 - 36.0
90.0
30
±24.0
±31.0
±10.3
69
35.0
±100
200
MA148S-05RU-xx
48
18.0 - 72.0
44.0
10
5.0
300.0
100.0
70
35.0
2,200
100
MA148S-09RU-xx
48
18.0 - 72.0
43.0
10
9.0
167.0
55.7
72
35.0
470
100
MA148S-12RU-xx
48
18.0 - 72.0
42.0
10
12.0
125.0
41.7
74
35.0
470
100
MA148S-15RU-xx
48
18.0 - 72.0
42.0
10
15.0
100.0
33.3
74
35.0
470
100
MA148S-24RU-xx
48
18.0 - 72.0
43.0
10
24.0
62.5
20.8
72
35.0
220
100
MA148D-05RU-xx
48
18.0 - 72.0
45.0
10
±5.0
±150.0
±50.0
68
35.0
±1,000
100
MA148D-09RU-xx
48
18.0 - 72.0
44.0
10
±9.0
±83.3
±27.8
70
35.0
±220
100
MA148D-12RU-xx
48
18.0 - 72.0
43.0
10
±12.0
±62.5
±20.8
72
35.0
±220
100
MA148D-15RU-xx
48
18.0 - 72.0
43.0
10
±15.0
±50.0
±16.7
72
35.0
±220
100
MA148D-24RU-xx
48
18.0 - 72.0
44.0
10
±24.0
±31.0
±10.3
71
35.0
±100
100
5.0
For the alternate pin-out (see page 4) , add suffix “P2” to model number
(i.e. MA124S-05RU-P2)
Notes:
1. Cross regulation is measured with the output being tested at 100% load while
the other output is varied from 25% to 100% load.
2. See the typical connection circuit on page three for typical external filtering components.
For help with a specific model or layout issue, contact the factory.
3. Isolation voltage is specified for Input to output. On units with the optional metal case,
the isolation voltage for Input - Case and Output - Case is 1,000 VDC.
4. Operation at no-load will not damage the unit, but they may not meet all specifications.
To meet all specifications, a minimum load of 33% should be maintained.
5. It is recommended that a fuse be used on the input of a power supply for protection.
See the Model Selection table above for the correct rating.
Model Number
300.0
100.0
68
35.0
2,200
200
NEW DIP DC/DC Converter
Families From MPD
Series
Power
Input Range
Isolation
MA100X-xxRW
1W
2:1
1.5 kVDC
MA100X-xxRWI
1W
2:1
3.5 kVDC
MA100X-xxRU
1W
4:1
1.5 kVDC
MA100X-xxRUI
1W
4:1
3.5 kVDC
MA200X-xxRW
2W
2:1
1.5 kVDC
MA200X-xxRWI
2W
2:1
3.5 kVDC
MA200X-xxRU
2W
4:1
1.5 kVDC
MA200X-xxRUI
2W
4:1
3.5 kVDC
MA300X-xxRW
3W
2:1
1.5 kVDC
MA300X-xxRWI
3W
2:1
3.0 kVDC
MA300X-xxRU
3W
4:1
1.5 kVDC
MA300X-xxRUI
3W
4:1
3.0 kVDC
MA400X-xxRW
4W
2:1
1.5 kVDC
MA400X-xxRWI
4W
2:1
3.5 kVDC
MA400X-xxRU
4W
4:1
1.5 kVDC
MA400X-xxRUI
4W
4:1
3.5 kVDC
MA500X-xxRW
5W
2:1
1.5 kVDC
MA500X-xxRWI
5W
2:1
3.5 kVDC
MA500X-xxRU
5W
4:1
1.5 kVDC
MA500X-xxRUI
5W
4:1
3.5 kVDC
MA600X-xxRW
6W
2:1
1.5 kVDC
MA600X-xxRWI
6W
2:1
3.0 kVDC
MA600X-xxRU
6W
4:1
1.5 kVDC
MA600X-xxRUI
6W
4:1
3.0 kVDC
Visit our website or contact the factory for more information.
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Typical Connection
The diagram above illustrates a typical connection of the MA100RU
series for applications that require meeting conducted EMC standards.
The units do not require external components to operate as specified.
For applications requiring very low output noise levels, the output
filtering capacitors (C3 is a low ESR electrolytic & C4 is a ceramic) will
often be sufficient. Care must be taken in choosing output capacitors
not to exceed the capacitive load specification for the unit. For dual
output units, output capacitors should be connected from each output
to common. All external components should be mounted as close to
the unit as possible.
The recommended values for components are:
Component
48 VIN
24 VIN
C1
220 µF/100V
220 µF/100V
LCM
12 µH
12 µH
470 pF/4kV MLCC 470 pF/4kV MLCC
C2
100 µF
100 µF
C3
4.7 - 10 µF
4.7 - 10 µF
C4
Typical Board Layout: With External Filter Components, Single Output
Typical Board Layout: With External Filter Components, Dual Output
Input noise and surge suppression modules are available for a number
of MPD DC/DC power supplies. Contact the factory for more information.
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Mechanical Dimensions
Standard Units - Plastic Case
Standard Units - Metal Case
Pin Connections
s
Pin
2
3
9
11
14
16
22
23
Single Output
-VIN
-VIN
No Pin
No Connection
+VOUT
-VOUT
+VIN
+VIN
Pin
2
3
9
11
14
16
22
23
Dual Output
-VIN
-VIN
Common
-VOUT
+VOUT
Common
+VIN
+VIN
For the alternate pin-out, add suffix “P2” to model number
(i.e. MA124S-05RU-P2)
Alternate Pin-Out Units - Plastic Case
Alternate Pin-Out Units - Metal Case
Pin Connectio
tions
Pin
1
2
3
10
11
12
13
14
15
22
23
24
Single Output
+VIN
No Connection
No Connection
-VOUT
+VOUT
-VIN
-VIN
+VOUT
-VOUT
No Connection
No Connection
+VIN
Pin
1
2
3
10
11
12
13
14
15
22
23
24
Dual Output
+VIN
-V
VOUT
Common
Common
+VOUT
-VIN
-VIN
+VOUT
Common
Common
-VOUT
+VIN
MicroPower Direct
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Pin 1 is marked by a “dot” or indentation on the top of the unit
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages