MASW-009482 GaAs Broadband High Power SP3T Switch DC - 4.0 GHz Rev. V1 Functional Schematic Features CDMA Handset Switching Applications Balanced (symmetrical) RF Ports Low Cross Modulation Low Insertion Loss: 0.55 dB @ 1 GHz High Isolation: 27 dB @ 1 GHz High Power: P0.1dB = 36 dBm @ 1 GHz 0.5 micron GaAs pHEMT Process Lead-Free 2 mm 12-Lead STQFN package with 0.5 mm lead pitch Halogen-Free ―Green‖ Mold Compound RoHS* Compliant and 260°C Reflow Compatible GND RFC GND 12 V3 V1 1 RF3 RF1 GND GND Description The MASW-009482 is an industry leading GaAs pHEMT MMIC single pole three throw (SP3T) switch in a lead-free 2 mm 12-lead STQFN package with 0.5 mm lead pitch. The MASW-009482 is uniquely configured to enable switching from a common antenna port to CDMA Cellular, PCS, or AWS ports. It is also ideal for other applications where a compact, high performance, symmetrical SP3T switch is required. GND Pin No. Function Description 1 V3 Control 3 2 RF3 RF Port 3 3 GND Ground 4 GND Ground 5 RF2 RF Port 2 6 V2 Control 2 7 GND Ground 8 RF1 RF Port 1 9 V1 Control 1 10 GND Ground 11 RFC RF Common 12 GND Ground 13 GND (paddle) Ground The MASW-009482 is fabricated using a 0.5 micron gate length GaAs pHEMT process. The process features full passivation for performance and reliability. 1,2 Ordering Information Package MASW-009482-TR3000 3000 piece reel MASW-009482-001SMB Sample Board 0.05 - 4.0 GHz Tuning V2 Pin Configuration 3 The design is symmetric and has been fully optimized for excellent cross modulation performance in all three paths while still maintaining excellent insertion loss and isolation. The symmetrical design allows the user to assign CDMA Cellular, PCS and AWS to ports RF1, RF2 or RF3 as required to optimize the layout. Part Number RF2 3. All package ground pins (P3,4,7,10, 12) and paddle ground are no connection (N/C) electrically to the internal die. M/A-COM Technology recommends connecting all ground connections to PCB ground to ensure a good thermal path. 1. Reference Application Note M513 for reel size information. 2. All sample boards include 5 loose parts. * Restrictions on Hazardous Substances, European Union Directive 2002/95/EC. 1 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MASW-009482 GaAs Broadband High Power SP3T Switch DC - 4.0 GHz Rev. V1 Electrical Specifications: TA = 25°C, Z0 = 50 Ω, VC = 0 V / 2.7 V, 1000 pF Capacitors 4 Parameter Test Conditions Units Min. Typ. Max. Insertion Loss (All Paths) 1.0 GHz 2.0 GHz 2.5 GHz dB dB dB — — — 0.55 0.75 0.75 0.7 0.9 0.9 Isolation 1.0 GHz 2.0 GHz 2.5 GHz dB dB dB 23 17 16 27 21 20 — — — Return Loss (All RF ports) DC - 2.5 GHz dB — 20 — Input IP3 Two Tone, +23 dBm/tone, 5 MHz Spacing, 1 GHz Two Tone, +23 dBm/tone, 5 MHz Spacing, 2 GHz dBm dBm — — 65 64 — — For Cell Band: Two-tone signal input: TX1 = +22 dBm @ 820 MHz, TX2 = +22 dBm @ 821 MHz, RX interferer = -23 dBm @ 865 MHz5 dBm — -108 — For PCS Band: Two-tone signal input: TX1 = +18 dBm @ 1880 MHz, TX2 = +18 dBm @ 1881 MHz, RX interferer = -23 dBm @ 1960 MHz5 dBm — -109 — 2nd Harmonic Fin = 1 GHz, Pin = +26 dBm Fin = 2 GHz, Pin = +26 dBm dBc — — 82 83 — — 3rd Harmonic Fin = 1 GHz, Pin = +26 dBm Fin = 2 GHz, Pin = +26 dBm dBc — — 84 74 — — Input P0.1dB VC = 0 V/2.7 V, 1 GHz dBm — 36 — Trise, Tfall 10% to 90% RF, 90% to 10% RF, 900 MHz ns — 45 — Ton, Toff 50% control to 90% RF, and 50% control to 10% RF, 900 MHz ns — 70 — Transients In Band mV — 40 — Control Current VC = 0 V/2.7 V µA — 6 25 Cross Modulation 4. External DC blocking capacitors are required on all RF ports. Typical performance specifications are with 1000 pF blocking and decoupling capacitors / as shown on the application schematic . 5. RX Interferer power set to –10 dBm during test to improve dynamic range of measurement system. Typical performance with –23 dBm interferer is determined by using a linear relationship between interferer power level and cross modulation products. Absolute Maximum Ratings 6,7 Parameter Absolute Maximum Input Power (0.5 - 4.0 GHz, 2.6 V Control) +36 dBm Control Voltage ±8.5 volts Operating Temperature -40°C to +85°C Storage Temperature -65°C to +150°C 6. Exceeding any one or combination of these limits may cause permanent damage to this device. 7. M/A-COM Technology does not recommend sustained operation near these survivability limits. Truth Table 8,9 V1 V2 V3 ANT-RF1 ANT-RF2 ANT-RF3 1 0 0 On Off Off 0 1 0 Off On Off 0 0 1 Off Off On 8. Differential voltage, V (state 1) -V (state 0) must be 2.6 V minimum and must not exceed 8.5 V. 9. Positive Control: 1 = +2.6 V to +8.0 V, 0 = 0 V +/- 0.2V Negative Control: 1 = 0 V +/- 0.2V, 0 = -2.6 V to -8.0 V 2 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MASW-009482 GaAs Broadband High Power SP3T Switch DC - 4.0 GHz Rev. V1 Typical Performance Curves: Z0 = 50 Ω, 1000 pF Blocking and decoupling caps, VCTL = 0/+2.7 VDC Insertion Loss Isolation 0.0 0 -10 -0.5 -20 -1.0 -30 -1.5 +25°C -40°C +85°C -40 +25°C -40°C +85°C -50 -2.0 -60 0 1 2 3 4 5 0 1 2 Frequency (GHz) 3 4 5 Frequency (GHz) Input Return Loss Input IP2 and IP3 0 120 IIP3 IIP2 110 -10 100 -20 90 80 -30 70 +25°C -40°C +85°C -40 60 -50 0 1 2 3 4 5 50 0.5 1.0 Frequency (GHz) 1.5 2.0 2.5 3.0 3.5 4.0 Frequency (GHz) Harmonics Input P0.1dB Compression 40 100 95 39 2nd Harmonic 3rd Harmonic 90 38 85 37 80 75 36 70 35 65 34 0.5 1.0 1.5 2.0 2.5 3.0 Frequency (GHz) 3.5 4.0 60 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Frequency (GHz) 3 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MASW-009482 GaAs Broadband High Power SP3T Switch DC - 4.0 GHz Rev. V1 Typical Performance Curves vs. Control Voltage: Z0 = 50 Ω, 1000 pF Blocking and decoupling caps Input IP2 vs. Control Voltage Input IP3 vs. Control Voltage 80 120 75 115 70 110 65 105 60 1.0 GHz 1.9 GHz 2.5 GHz 3.5 GHz 100 1.0 GHz 1.9 GHz 2.5 GHz 3.5 GHz 55 50 2.0 2.5 3.0 3.5 4.0 4.5 95 5.0 90 2.0 2.5 Control Voltage (Vdc) 95 95 90 90 85 85 80 80 75 75 4.0 70 1.0 GHz 1.9 GHz 2.5 GHz 3.5 GHz 65 3.5 4.5 5.0 3rd Harmonic vs. Control Voltage 2nd Harmonic vs. Control Voltage 70 3.0 Control Voltage (Vdc) 1.0 GHz 1.9 GHz 2.5 GHz 3.5 GHz 65 60 60 55 2.0 2.5 3.0 3.5 4.0 4.5 5.0 55 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Control Voltage (Vdc) Control Voltage (Vdc) Input P0.1dB vs. Control Voltage 42 40 38 36 34 1.0 GHz 1.9 GHz 2.5 GHz 3.5 GHz 32 30 28 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Control Voltage (Vdc) 4 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MASW-009482 GaAs Broadband High Power SP3T Switch DC - 4.0 GHz Rev. V1 Application Schematic 10,11 Qualification Qualified to M/A-COM specification REL-201, Process Flow –2. GND RFC VC1 GND VC3 12 Handling Procedures 1 RF1 GND GND V2 RF3 RF2 V1 GND V3 Please observe the following precautions to avoid damage: Static Sensitivity VC2 Gallium Arsenide Integrated Circuits are sensitive to electrostatic discharge (ESD) and can be damaged by static electricity. Proper ESD control techniques should be used when handling these devices. 10. The exposed pad centered on the package bottom must be connected to ground to ensure a good thermal path. 11. All blocking and decoupling capacitors = 1000 pF Lead-Free 2mm STQFN-12LD-0.5 mm Pitch† NOTE: ALL DIMENSIONS SHOWN AS in/mm. † Reference Application Note S2083 for lead-free solder reflow recommendations. Meets JEDEC moisture sensitivity level 1 requirements. Plating is 100% matte tin over copper. 5 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MASW-009482 GaAs Broadband High Power SP3T Switch DC - 4.0 GHz Rev. V1 Applications Section: Tri-Mode Mobile Phone Performance Typical Electrical Performance: TA = 25°C, Z0 = 50Ω, VC = 0V/2.6V, 1000pF Capacitors 1 Parameter Test Conditions Units Min. Typ. Max. Insertion Loss (All Paths) 824 - 894 MHz (CELL) 1710 - 1755 MHz (AWS) 1850 - 1990 MHz (PCS) dB dB dB — — — 0.55 0.65 0.75 — — — Isolation 824 - 894 MHz (CELL) 1710 - 1755 MHz (AWS) 1850 - 1990 MHz (PCS) dB dB dB — — — 27 23 22 — — — Return Loss (All RF ports) DC - 2.5 GHz dB — 20 — Input IP3 Two Tone, +23 dBm/tone, 1 MHz Spacing, 894 MHz Two Tone, +23 dBm/tone, 1 MHz Spacing, 1755 MHz Two Tone, +23 dBm/tone, 1 MHz Spacing, 1990 MHz dBm dBm dBm — — 68 65 67 — — For Cell Band: Two-tone signal input: TX1 = +22 dBm @ 820 MHz, TX2 = +22 dBm @ 821 MHz, RX interferer = -23 dBm @ 865 MHz2 dBm — -105 — For PCS Band: Two-tone signal input: TX1 = +18 dBm @ 1880 MHz, TX2 = +18 dBm @ 1881 MHz, RX interferer = -23 dBm @ 1960 MHz2 dBm — -103 — 2nd Harmonic Fin = 894 MHz, Pin = +25.5 dBm Fin = 1755 MHz, Pin = +25.0 dBm Fin = 1990 MHz, Pin = +24.0 dBm dBc dBc dBc — — 81 81 85 — — 3rd Harmonic Fin = 894 MHz, Pin = +25.5 dBm Fin = 1755 MHz, Pin = +25.0 dBm Fin = 1990 MHz, Pin = +24.0 dBm dBc dBc dBc — — 82 81 91 — — Input P0.1dB Fin = 894 MHz Fin = 1755 MHz Fin = 1990 MHz dBm dBm dBm — 34.5 36.0 35.5 — Trise, Tfall 10% to 90% RF, 90% to 10% RF, 900 MHz ns — 45 — Ton, Toff 50% control to 90% RF, and 50% control to 10% RF, 900 MHz ns — 70 — Transients In Band mV — 40 — Control Current VC = 0 V/2.6 V µA — 6 — Cross Modulation 1. External DC blocking capacitors are required on all RF ports. Typical performance specifications are with 1000 pF blocking and decoupling capacitors / as shown on the application schematic . 2. RX Interferer power set to –10 dBm during test to improve dynamic range of measurement system. Typical performance with –23 dBm interferer is determined by using a linear relationship between interferer power level and cross modulation products. 6 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MASW-009482 GaAs Broadband High Power SP3T Switch DC - 4.0 GHz Rev. V1 Applications Section - Tri-Mode Mobile Phone Performance Typical Performance Curves: TA = 25°C, Z0 = 50Ω, VC = 0V/2.6V, 1000pF Capacitors Isolation Insertion Loss CELL 0.0 AWS PCS CELL 0 AWS PCS -10 -0.5 -20 -1.0 -30 -1.5 +25°C -40°C +85°C -2.0 0.50 1.0 -40 1.5 2.0 2.5 +25°C -40°C +85°C -50 0.50 1.0 Input Return Loss 2.0 2.5 Input IP2 and IP3 CELL 0 1.5 Frequency (GHz) Frequency (GHz) AWS PCS 120 IP2 IP3 100 -10 80 -20 60 -30 40 -40 +25°C -40°C +85°C -50 0.50 20 0 1.0 1.5 2.0 2.5 Cell (894 MHz) Frequency (GHz) Input P0.1dB Compression AWS (1755 MHz) PCS (1990 MHz) Harmonics 37 95 36 90 35 85 34 80 33 75 32 70 31 65 2nd Harmonic 3rd Harmonic 60 30 Cell (894 MHz) AWS (1755 MHz) PCS (1990 MHz) Cell (894 MHz) AWS (1755 MHz) PCS (1990 MHz) 7 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MASW-009482 GaAs Broadband High Power SP3T Switch DC - 4.0 GHz Rev. V1 M/A-COM Technology Solutions Inc. All rights reserved. Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM") products. These materials are provided by MACOM as a service to its customers and may be used for informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM assumes no responsibility for errors or omissions in these materials. MACOM may make changes to specifications and product descriptions at any time, without notice. MACOM makes no commitment to update the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise, to any intellectual property rights is granted by this document. THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS, WHICH MAY RESULT FROM THE USE OF THESE MATERIALS. MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM customers using or selling MACOM products for use in such applications do so at their own risk and agree to fully indemnify MACOM for any damages resulting from such improper use or sale. 8 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support