Click on Series name for product info on aimtec.com Series AM30K-Z 30 Watt | DC-DC Converter FEATURES: Wide Input 2:1 Range Full SMD Technology 1500 VDC Isolation Efficiency up to 91% Adjustable Output Voltage Remote ON/OFF Function Over Current, Voltage, & Temperature Protection Soft Start Models: Single output Model Input – Voltage (V) AM30K-1203SZ 9-18 AM30K-1205SZ 9-18 AM30K-1212SZ 9-18 AM30K-1215SZ 9-18 AM30K-2403SZ 18-36 AM30K-2405SZ 18-36 AM30K-2412SZ 18-36 AM30K-2415SZ 18-36 AM30K-4803SZ 36-75 AM30K-4805SZ 36-75 AM30K-4812SZ 36-75 AM30K-4815SZ 36-75 Add suffix “-K” for optional heat sink Output Voltage (V) Output Current max (A) Isolation (VDC) Max Capacitive Load (uF) Efficiency (%) 3.3 5 12 15 3.3 5 12 15 3.3 5 12 15 5.5 5.0 2.5 2.0 5.5 5.0 2.5 2.0 5.5 5.0 2.5 2.0 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 15000 10000 2200 1000 15000 10000 2200 1000 15000 10000 2200 1000 83 86 90 90 84 87 91 91 84 87 91 91 Output Voltage (V) Output Current max (A) Isolation (VDC) Max Capacitive Load (uF) Efficiency (%) ±12 ±15 ±12 ±15 ±12 ±15 ±1.25 ±1.0 ±1.25 ±1.0 ±1.25 ±1.0 1500 1500 1500 1500 1500 1500 ±1000 ±680 ±1000 ±680 ±1000 ±680 90 90 91 91 90 90 Models: Dual output Model Input – Voltage (V) AM30K-1212DZ 9-18 AM30K-1215DZ 9-18 AM30K-2412DZ 18-36 AM30K-2415DZ 18-36 AM30K-4812DZ 36-75 AM30K-4815DZ 36-75 Add suffix “-K” for optional heat sink NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Input Specifications Nominal Typical 12 24 48 9-18 18-36 36-75 Voltage range Filter Start up time Absolute Maximum Rated Input Voltage Peak Input Voltage time On/Off Control Maximum Units VDC π(Pi) Network 20 ms 25 VDC 50 100 100 ms ON – high or open (2.5V TO 5.5V); OFF – low (-0.7V to 0.8V or short circuit between pin 2 & 3) 12 24 48 Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance www.aimtec.com F 051e R8.G Conditions Typical 3 sec 1000 1200 Tel: +1 514 620 2722 1 of 4 Rated Units 1500 VDC MOhm pF Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30K-Z 30 Watt | DC-DC Converter Output Specifications Output Specifications Voltage accuracy Voltage balance (Dual Output model) Over voltage protection Over current protection Short Circuit protection Short circuit restart Line voltage regulation (Single) Line voltage regulation (Dual) Load voltage regulation (Single) Load voltage regulation (Dual) Temperature coefficient Ripple & Noise Voltage adjustment range Conditions Typical Maximum ±5 ±5 125 120 Balanced Load HL-LL HL-LL 10% to 100% Load 10% to 100% Load At 20MHz Bandwidth Units % % % % Continuous Auto Recovery ±5 ±5 ±0.5 ±0.5 ±0.02 75 ±10 % % % % %/oC m Vp-p % General Specifications Input Specifications Conditions Typical Switching frequency Operating temperature Storage temperature Max Case temperature Cooling Humidity Over Temperature Protection Case material Weight Dimensions (L X W X H) MTBF 100% load With derating above 60 oC (see graph below) 270 Maximum Units -40 to +85 -40 to +125 100 Free air convection 95 110 Nickel-coated Copper and Epoxy (UL94V-0 rated) 48 2.00 x1.60 x0.40 inches 50.80 x 40.60 x 10.20 mm >1000000 hrs Calculated using MIL-HDBK-217 F at +25 oC KHz o C o C % g Safety Specifications Standards Agency approvals CE IEC/EN 60950-1 EN55022 Class A EN55022 Class A EN61000-4-2 Perf. Criteria B EN61000-4-3 Perf. Criteria A EN61000-4-4 Perf. Criteria B EN61000-4-5 Perf. Criteria B EN61000-4-6 Perf. Criteria A EN61000-4-8 Perf. Criteria A Safety Pin Out Specifications Pin Single Dual 1 2 3 4 5 6 7 +Vin -Vin On/Off Control No Pin +Vout -Vout Trim +Vin -Vin On/Off Control +Vout Com -Vout Trim www.aimtec.com F 051e R8.G Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30K-Z 30 Watt | DC-DC Converter Dimensions 50.80 (2.00) 4 1 2 5 Bottom View 6 3 Printed Face 7 45.72 (1.80) Built-in Stand-offs to ease PCB Cleaning Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Pitch Tolerance ±0.35 (±0.014) 2.54 (0.10) Ø 1.00 (0.04) Dimensions with Optional Heat Sink Notes: Add “-K” suffix for ordering, heat sink is affixed with thermally dissipative adhesive tape. See derating graph for temperature performance. Heat sink material is anodized (black) aluminum, adds weight 17g to total mass (65g). Thermal impedance of converter is: with heatsink 8.7 Ԩ/W and 10Ԩ/W without heat sink. Trimming www.aimtec.com F 051e R8.G Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30K-Z 30 Watt | DC-DC Converter Derating Extended temperature performance can be achieved with optional heat sink. (add suffix “–K” to part number) Control ON/OFF pin connection example: Note A: An external filter capacitor is required if the module has to meet EN61000-4-4 and EN61000-4-5. The filter capacitor Aimtec suggests: 1000uF, 100V. Models AM30K-12XXXZ AM30K-24XXXZ AM30K-48XXXZ C1 330 μf, 100V 330 μf, 100V 330 μf, 100V L 12μH 12μH 12μH C2 100μ, 100V 100μ, 100V 100μ, 100V C3 N/A N/A 1000Pf, 2000V Note B: Input filter components (C1, C2, L) are used to help meet conducted emissions requirement for the module. These components should be mounted as close as possible to the module; and all leads should be minimized to decrease radiated noise. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R8.G Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only