MG800RU Series Compact, 8W 4:1 Input, MiniDIP DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: Input Parameter • 8W Output Power • Very Small MiniDIP Case • EN 60950 Approved Input Start-up Threshold • Wide 4:1 Input Range Under Voltage Shutdown • High Efficiency Input Filter • 1,500 VDC Isolation Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20 MHz) Transient Recovery Time Transient Response Deviation Overload Protection Temperature Coefficient Output Short Circuit • Single and Dual Outputs • >1.0 MHour MTBF • -40°C to +80°C Operation • LOW COST Conditions Min. 24 VDC Input 9.0 48 VDC Input 18.0 24 VDC Input 48 VDC Input 24 VDC Input 48 VDC Input (Pi) Filter Typ. 24.0 48.0 Max. 36.0 75.0 9.0 18.0 8.0 16.0 Units VDC VDC VDC Output Conditions Dual Output, Balanced Loads VIN = Min To Max IOUT = 0% To 100% See Note 2 See Note 3 See Note 4 See Note 5 Min. Typ. Max. ±2.0 ±2.0 ±0.8 ±1.0 55 500 ±5.0 Units % ±1.0 % ±0.2 % ±0.5 % mV P - P µSec ±3.0 % 150 % ±0.01 ±0.02 %/°C Continuous (Autorecovery) Min. 1,500 1,800 1,000 Typ. Max. General Parameter Conditions 60 Seconds 1 Second 500 VDC 100 kHz, 1V Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency EMI Characteristics Parameter Radiated Emissions Conducted Emissions ESD RS EFT, See Note 6 Surge, See Note 6 CS PFMF Standard VDC M pF kHz 500 370 Criteria EN 55022 EN 55022 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 Units Level Class A Class A ±6 kV Contact/±8kV Air 20V/m ±2 kV ±1 kV 10 Vrms 3A/m A A A A A A Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA Parameter Operating Temperature Range Max Case Temperature Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Conditions Ambient Min. -40 Typ. +25 -50 Free Air Convection RH, Non-condensing Max. +80 +105 +125 Units °C °C °C 95 % See Mechanical Diagram (Page 2) Aluminum Alloy, Black Anodized Coating (UL-94V0) 0.20 Oz (6.1g) Reliability Specifications T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter MTBF Safety Standards Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 1.06 UL 60950, EN 60950 Max. Units MHours Max. 50.0 100.0 260 Units Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Conditions 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec Min. Typ. Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC °C www.micropowerdirect.com Model Selection Guide Input Model Number MG824S-03RU MG824S-05RU MG824S-12RU MG824S-15RU MG824S-24RU MG824D-12RU MG824D-15RU MG848S-03RU MG848S-05RU MG848S-12RU MG848S-15RU MG848S-24RU MG848D-12RU MG848D-15RU Voltage (VDC) Nominal 24 24 24 24 24 24 24 48 48 48 48 48 48 48 Range 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 Output Current (mA) Voltage Full-Load No-Load (VDC) 282 10 3.3 407 10 5.0 391 10 12.0 393 10 15.0 390 10 24.0 394 10 ±12.0 385 10 ±15.0 141 8 3.3 206 8 5.0 196 8 12.0 197 8 15.0 195 8 24.0 195 8 ±12.0 193 8 ±15.0 Notes: 1. The specified maximum capacitive load is for each output. 2. When measuring output ripple, it is recommended that an external 0.47 µF ceramic capacitor be placed in parallel from the +VOUT pin to the -VOUT pin for single output models, or from each output to common for dual output models. 3. Transient recovery is measured to within a 1% error band for a load step change of 25%. 4. Output overload protection is provided by a Hiccup circuit with auto-recovery. 5. Output short circuit protection is provided by a Hiccup circuit with auto-recovery. 6. These converters are specified for operation without external components. However, in some applications the addition of input/output capacitors, as shown in the typical connection diagram at right, will enhance stability and reduce output ripple. This simple connection includes a low ESR (<1Ω at 100 kHz) capacitor connected across the input. It is recommended that a 2.2 µF be used. To improve the output ripple performance, a 3.3 µF is connected across the output. For dual output units, a 3.3 µF capacitor should be connected from each output to common. For applications where the circuit must meet or exceed EN 61000-4-4 (5), refer to the note under the typical connection diagram. 7. Operation at no load will not damage these units, however, they may not meet all specifications. 8. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Current Current Output Capacitive Load (mA, Max) (mA, Min) (µF Max) 1,600 1,600 665 535 335 ±335 ±265 1,600 1,600 665 535 335 ±335 ±265 0.0 0.0 0.0 0.0 0.0 ±0.0 ±0.0 0.0 0.0 0.0 0.0 0.0 ±0.0 ±0.0 Rating Efficiency Fuse Slow-Blow (%, Typ) (mA) 680 680 330 330 150 150 150 680 680 330 330 150 150 150 78 82 85 85 86 85 86 78 81 85 85 86 86 86 1,500 2,000 2,000 2,000 2,000 2,000 2,000 800 1,000 1,000 1,000 1,000 1,000 1,000 Typical Connection Notes: To meet the specified EN 61000-4-4 and EN 61000-4-5 limits, an external capacitor must be connected across the input pins of the module (C1). A 220 µF/100V capacitor is recommended. This capacitor should be mounted as close to the module as possible. Derating Curve Mechanical Dimensions Pin Connections Pin Single Dual 1 -VIN -VIN 7 NC NC 8 NC Common 9 +VOUT +VOUT 10 -VOUT -VOUT 16 +VIN +VIN NC = No Connection MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) • Pin 1 is marked by a “dot” or indentation on the unit FAX: (781) 344-8481 • E-Mail: [email protected]