HLP-80H 80W Single Output Switching Power Supply series Features : Universal AC input / Full range (up to 305VAC) Built-in active PFC function Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection Output constant current level adjustable Class 2 power unit Three in one dimming function (1~10Vdc or PWM signal or resistance) Suitable for built in LED lighting system Suitable for dry / damp locations 100% full load burn-in test 3 years warranty M M SELV ( for 48V,54V only) SPECIFICATION MODEL HLP-80H-12 HLP-80H-15 HLP-80H-20 HLP-80H-24 HLP-80H-30 HLP-80H-36 HLP-80H-42 HLP-80H-48 HLP-80H-54 12V DC VOLTAGE CONSTANT CURRENT REGION Note.4 7.2 ~12V 48V 54V 25.2 ~ 42V 28.8 ~ 48V 32.4 ~ 54V 4A 3.4A 2.3A 1.95A 1.7A 1.5A 75W 80W 81.6W 81W 82.8W 81.9W 81.6W 81W 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p 200mVp-p 200mVp-p 17 ~ 22V 22 ~ 27V 27 ~ 33V 33 ~ 40V 38 ~ 46V 43 ~ 53V 49 ~ 58V 1.84 ~ 2.3A 1.56 ~ 1.95A 1.36 ~ 1.7A 1.0% 1.0% 10.8 ~ 13.5V 13.5 ~ 17V VOLTAGE ADJ. RANGE Can be adjusted by internal potentiometer or through output connector 4 ~ 5A 4 ~ 5A 3.2 ~ 4A VOLTAGE TOLERANCE Note.3 2.5% 2.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 1.5% 1.0% 2.0% Note.6 2000ms, 200ms / 115VAC at full load 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 16ms at full load Note.5 90 ~ 305VAC 2.72 ~ 3.4A 2.16 ~ 2.7A 1.2 ~ 1.5A 1.0% 1000ms, 200ms / 230VAC at full load 230VAC /115VAC 127 ~ 431VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve) EFFICIENCY (Typ.) 87.5% AC CURRENT (Typ.) INRUSH CURRENT(Typ.) 89.5% 88.5% 0.85A / 115VAC 0.425A / 230VAC COLD START 70A/230VAC LEAKAGE CURRENT <0.75mA / 277VAC OVER CURRENT Note.4 SHORT CIRCUIT OVER VOLTAGE 90% 90% 0.4A / 277VAC 90% 90% 90% 90% 54 ~ 63V 59 ~ 68V 95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed 48 ~ 58V 35 ~ 43V 14 ~ 17V 18 ~ 24V 28 ~ 35V 41 ~ 49V 23 ~ 30V Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE 95 10 (RTH2) Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. -40 ~ +70 WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT (Refer to "Derating Curve") 20 ~ 95% RH non-condensing -40 ~ +80 0.03%/ , 10 ~ 95% RH (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes SAFETY STANDARDS UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1 WITHSTAND VOLTAGE I/P-O/P:3.75KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55015, EN61000-3-2 Class C ( 60% load, 12V model EMC EMISSION EMC IMMUNITY MTBF DIMENSION PACKING NOTE 42V 21.6 ~ 36V 5A VOLTAGE RANGE OTHERS 36V 60W HOLD UP TIME (Typ.) EMC 30V 14.4 ~ 24V 5A SETUP, RISE TIME SAFETY & 24V 12 ~ 20V RATED POWER LOAD REGULATION PROTECTION 20V 9 ~ 15V RATED CURRENT CURRENT ADJ. RANGE INPUT 15V 18 ~ 30V 2.7A RIPPLE & NOISE (max.) Note.2 150mVp-p OUTPUT ( except for 48V,54V ) I/P-FG:1.88KVAC O/P-FG:0.5KVAC 65% load) ; EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A 316.2Khrs min. MIL-HDBK-217F (25 ) 167*53*29.5mm (L*W*H) 0.27Kg; 36pcs/11.2Kg/0.67CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 8. Heat Sink HS1,HS2 can not be shorted. File Name:HLP-80H-SPEC 2012-03-01 HLP-80H 80W Single Output Switching Power Supply Mechanical Specification series Unit:mm 167 159.5 5 3.5 HS2 CN2 43 6 5 4 CN1 3 2 1 FS1 T3.15A/300V /350V 6 5 4 3 2 1 4- SVR2 SVR1 3.5 3max. 29.5max. 53 HS1 AC Input Connector (CN1) : JST B6P-VH or equivalent Pin No. 1 2,4,5 3 6 Assignment AC/L No Pin AC/N FG DC Output Connector (CN2) : JST B6P-VH or equivalent Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Pin No. 1 2 3,4 5,6 Assignment DIM+(VR1) DIM-(VR2) +V -V Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent HS1,HS2 can not be shorted : Grounding required Block Diagram fosc : 100KHz EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT +V -V DIM+ DIM- O.L.P. O.T.P. FG O.L.P. DETECTION CIRCUIT PWM & PFC CONTROL O.V.P. Derating Curve Static Characteristics 100 100 90 80 80 230VAC Input only 70 60 LOAD (%) 50 40 20 -40 -25 -10 0 15 30 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 305 INPUT VOLTAGE (V) 60Hz File Name:HLP-80H-SPEC 2012-03-01 80W Single Output Switching Power Supply HLP-80H series Power Factor Characteristic Constant Current Mode 1 0 .9 9 0 .9 8 0 .9 7 277VAC PF 0 .9 6 230VAC 115VAC 0 .9 5 0 .9 4 0 .9 3 0 .9 2 50% 60% 70% 80% 90% 100% (80W) LOAD EFFICIENCY vs LOAD (48V Model) HLP-80H series possess superior working efficiency that up to 90% can be reached in field applications. 94 92 90 EFFICIENCY (%) 88 86 84 82 277VAC 80 230VAC 78 115VAC 76 74 72 70 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD DRIVING METHODS OF LED MODULE There are two major kinds of LED drive method "direct drive" and "with LED driver". A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs. Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B). (B) Constant Current area Vo(%) 100 (A) Constant Voltage area 60 (max.) (C) Hiccup Protection 50 95 Io (%) Typical LED power supply I-V curve File Name:HLP-80H-SPEC 2012-03-01 HLP-80H 80W Single Output Switching Power Supply series DIMMING OPERATION FG -V -V +V +V DIMDIM+ AC/N AC/L Built-in 3 in 1 dimming function, output constant current level can be adjusted through output connector by 1~10VDC, PWM signal, or connecting a resistance between DIM+ and DIM-. Please DO NOT connect "DIM-" to "-V". Reference resistance value for output current adjustment (Typical) OPEN 20K 10K 30K 40K 50K 70K 80K 90K Single driver 100K 60K Resistance Multiple drivers value (N=driver quantity for synchronized 10K /N 20K /N 30K /N 40K /N 50K /N 60K /N 70K /N 80K /N 90K /N 100K /N ----- dimming operation) Percentage of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 102%~108% OPEN 1 ~ 10V dimming function for output current adjustment (Typical) Dimming value 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V Percentage of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 102%~108% 10V PWM signal for output current adjustment (Typical): Frequency range :100HZ ~ 3KHz Duty value 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Percentage of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 102%~108% OPEN Using the built-in dimming function can't turn the lighting fixture totally dark. Please refer to the connection method below to achieve 0% brightness of the lighting fixture connecting to the LED power supply unit. Dimming connection diagram for turning the lighting fixture ON/OFF : N FG L Switch Relay Adjuster 0~100K Ohms resistance 1~10V DC Voltage 10V PWM Signal Green/ Yellow Brown Blue AC/L AC/N HLP-80H DIM+ DIMV(-) V(+) Blue White Black Red LED Lighting Fixture Using a switch and relay can turn ON/OFF the lighting fixture. 1.Output constant current level can be adjusted through output cable by connecting a resistance or 1~10Vdc or 10V PWM signal between DIM+ and DIM-. 2.The LED lighting fixture can be turned ON/OFF by the switch. File Name:HLP-80H-SPEC 2012-03-01