STMicroelectronics M24M01-A125 Automotive 1-mbit serial ic bus eeprom with 1 mhz clock Datasheet

M24M01-A125
Automotive 1-Mbit serial I²C bus EEPROM with 1 MHz clock
Datasheet - production data
Features
• Compatible with all I2C bus modes
– 1 MHz
– 400 kHz
– 100 kHz
TSSOP8 (DW)
169 mil width
• Memory array
– 1 Mbit (128 Kbytes) of EEPROM
– Page size: 256 bytes
– Additional Write lockable page
(Identification page)
• Extended temperature and voltage ranges
– -40 °C to 125 °C; 2.5 V to 5.5 V
• Schmitt trigger inputs for noise filtering.
SO8 (MN)
150 mil width
• Short Write cycle time
– Byte Write within 4 ms
– Page Write within 4 ms
• Write cycle endurance
– 4 million Write cycles at 25 °C
– 1.2 million Write cycles at 85 °C
– 600 k Write cycles at 125 °C
• Data retention
– 50 years at 125 °C
– 100 years at 25 °C
• ESD Protection (Human Body Model)
– 4000 V
• Packages
– RoHS compliant and halogen-free
(ECOPACK®2)
February 2014
This is information on a product in full production.
DocID023765 Rev 4
1/37
www.st.com
Contents
M24M01-A125
Contents
1
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2
Signal description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3
4
2.1
Serial Clock (SCL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.2
Serial Data (SDA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.3
Chip Enable (E2, E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.4
Write Control (WC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.5
VSS (ground) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.6
Supply voltage (VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Device operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.1
Start condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
3.2
Stop condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
3.3
Data input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
3.4
Acknowledge bit (ACK) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
3.5
Device addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.6
Identification page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.1
4.2
2/37
Write operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.1.1
Byte Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.1.2
Page Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.1.3
Write Identification Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.1.4
Lock Identification Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.1.5
Minimizing Write delays by polling on ACK . . . . . . . . . . . . . . . . . . . . . . 18
Read operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.2.1
Random Address Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.2.2
Current Address Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.2.3
Sequential Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.2.4
Read Identification Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.2.5
Read the lock status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.2.6
Acknowledge in Read mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
DocID023765 Rev 4
M24M01-A125
5
Contents
Application design recommendations . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.1
5.2
Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.1.1
Operating supply voltage (VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.1.2
Power-up conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.1.3
Power-down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Cycling with Error Correction Code (ECC) . . . . . . . . . . . . . . . . . . . . . . . . 24
6
Delivery state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
7
Maximum rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
8
DC and AC parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
9
Package mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
10
Part numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
11
Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
DocID023765 Rev 4
3/37
3
List of tables
M24M01-A125
List of tables
Table 1.
Table 2.
Table 3.
Table 4.
Table 5.
Table 6.
Table 7.
Table 8.
Table 9.
Table 10.
Table 11.
Table 12.
Table 13.
Table 14.
Table 15.
Table 16.
4/37
Signal names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Device select code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Address significant bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Device identification code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Cycling performance by groups of four bytes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Operating conditions (voltage range W) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
AC measurement conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Input parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
DC characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
400 kHz AC characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
1 MHz AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
TSSOP8 – 8-lead thin shrink small outline, package mechanical data. . . . . . . . . . . . . . . . 33
SO8N – 8 lead plastic small outline, 150 mils body width, package data . . . . . . . . . . . . . . 34
Ordering information scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
DocID023765 Rev 4
M24M01-A125
List of figures
List of figures
Figure 1.
Figure 2.
Figure 3.
Figure 4.
Figure 5.
Figure 6.
Figure 7.
Figure 8.
Figure 9.
Figure 10.
Figure 11.
Figure 12.
Figure 13.
Figure 14.
Logic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
8-pin package connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Device select code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
I2C bus protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Write mode sequences with WC = 0 (data write enabled) . . . . . . . . . . . . . . . . . . . . . . . . . 16
Write mode sequences with WC = 1 (data write inhibited) . . . . . . . . . . . . . . . . . . . . . . . . . 17
Write cycle polling flowchart using ACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Read mode sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
AC measurement I/O waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Maximum Rbus value versus bus parasitic capacitance (Cbus) for an I2C
bus at maximum frequency fC = 400 kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Maximum Rbus value versus bus parasitic capacitance Cbus) for an I2C
bus at maximum frequency fC = 1MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
AC waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
TSSOP8 – 8-lead thin shrink small outline, package outline . . . . . . . . . . . . . . . . . . . . . . . 33
SO8N – 8 lead plastic small outline, 150 mils body width, package outline . . . . . . . . . . . . 34
DocID023765 Rev 4
5/37
5
Description
1
M24M01-A125
Description
The M24M01-A125 is a 1-Mbit serial EEPROM Automotive grade device operating up to
125 °C. The M24M01-A125 is compliant with the very high level of reliability defined by the
Automotive standard AEC-Q100 grade 1.
The device is accessed by a simple serial I2C compatible interface running up to 1 MHz.
The memory array is based on advanced true EEPROM technology (Electrically Erasable
PROgrammable Memory). The M24M01-A125 is a byte-alterable memory (128 K × 8 bits)
organized as 512 pages of 256 bytes in which the data integrity is significantly improved
with an embedded Error Correction Code logic.
The M24M01-A125 offers an additional Identification Page (256 bytes) in which the ST
device identification can be read. This page can also be used to store sensitive application
parameters which can be later permanently locked in read-only mode.
Figure 1. Logic diagram
7#
%
%
(IGH VOLTAGE
GENERATOR
#ONTROL LOGIC
3#,
3$!
)/ SHIFT REGISTER
$ATA
REGISTER
9 DECODER
!DDRESS REGISTER
AND COUNTER
PAGE
)DENTIFICATION PAGE
8 DECODER
-36
6/37
DocID023765 Rev 4
M24M01-A125
Description
Table 1. Signal names
Signal name
Function
Direction
E2, E1
Chip Enable
Input
SDA
Serial Data
I/O
SCL
Serial Clock
Input
WC
Write Control
Input
VCC
Supply voltage
-
VSS
Ground
-
Figure 2. 8-pin package connections
--
$5
%
%
633
6##
7#
3#,
3$!
-36
1. DU: Don't Use (if connected, must be connected to VSS)
2. See Section 9: Package mechanical data for package dimensions, and how to identify pin 1.
DocID023765 Rev 4
7/37
36
Signal description
M24M01-A125
2
Signal description
2.1
Serial Clock (SCL)
The signal applied on this input is used to strobe the data available on SDA(in) and to output
the data on SDA(out).
2.2
Serial Data (SDA)
SDA is an input/output used to transfer data in or out of the device. SDA(out) is an open
drain output that may be wire-OR’ed with other open drain or open collector signals on the
bus. A pull up resistor must be connected between SDA and VCC (Figure 10 indicates how
to calculate the value of the pull-up resistor).
2.3
Chip Enable (E2, E1)
(E2,E1) input signals are used to set the value that is to be looked for on the three least
significant bits (b3, b2) of the 7-bit device select code (see Table 2). These inputs must be
tied to VCC or VSS, as shown in Figure 3. When not connected (left floating), these inputs
are read as low (0).
Figure 3. Device select code
6##
6##
-XXX
-XXX
%I
%I
633
633
!I
2.4
Write Control (WC)
This input signal is useful for protecting the entire contents of the memory from inadvertent
write operations. Write operations are disabled to the entire memory array when Write
Control (WC) is driven high. Write operations are enabled when Write Control (WC) is either
driven low or left floating.
When Write Control (WC) is driven high, device select and address bytes are
acknowledged, Data bytes are not acknowledged.
8/37
DocID023765 Rev 4
M24M01-A125
2.5
Signal description
VSS (ground)
VSS is the reference for the VCC supply voltage.
2.6
Supply voltage (VCC)
VCC is the supply voltage pin.
DocID023765 Rev 4
9/37
36
Device operation
3
M24M01-A125
Device operation
The device supports the I2C protocol (see Figure 4).
The I2C bus is controlled by the bus master and the device is always a slave in all
communications.
The device (bus master or a slave) that sends data on to the bus is defined as a transmitter;
the device (bus master or a slave) is defined as a receiver when reading the data.
Figure 4. I2C bus protocol
3#,
3$!
3$!
)NPUT
34!24
#ONDITION
3#,
3$!
-3"
3$!
#HANGE
34/0
#ONDITION
!#+
34!24
#ONDITION
3#,
3$!
-3"
!#+
34/0
#ONDITION
!)"
10/37
DocID023765 Rev 4
M24M01-A125
3.1
Device operation
Start condition
Start is identified by a falling edge of Serial Data (SDA) while Serial Clock (SCL) is stable in
the high state. A Start condition must precede any data transfer instruction. The device
continuously monitors (except during a Write cycle) Serial Data (SDA) and Serial Clock
(SCL) for a Start condition.
3.2
Stop condition
Stop is identified by a rising edge of Serial Data (SDA) while Serial Clock (SCL) is stable and
driven high. A Stop condition terminates communication between the device and the bus
master.
A Stop condition at the end of a Write instruction triggers the internal Write cycle.
3.3
Data input
During data input, the device samples Serial Data (SDA) on the rising edge of Serial Clock
(SCL). For correct device operation, Serial Data (SDA) must be stable during the rising edge
of Serial Clock (SCL), and the Serial Data (SDA) signal must change only when Serial Clock
(SCL) is driven low.
3.4
Acknowledge bit (ACK)
The acknowledge bit is used to indicate a successful byte transfer. The bus transmitter,
whether it be bus master or slave device, releases Serial Data (SDA) after sending eight bits
of data. During the 9th clock pulse period, the receiver pulls Serial Data (SDA) low to
acknowledge the receipt of the eight data bits.
DocID023765 Rev 4
11/37
36
Device operation
3.5
M24M01-A125
Device addressing
To start communication between the bus master and the slave device, the bus master must
initiate a Start condition. Following this, the bus master sends the device select code, as
shown in Table 2.
The device select code consists of a 4-bit device type identifier and a 2-bit Chip Enable
address (E2, E1). A device select code handling any value other than 1010b (to select the
memory) or 1011b (to select the Identification page) is not acknowledged by the memory
device.
Up to four memory devices can be connected on a single I2C bus. Each one is given a
unique 2-bit code on the Chip Enable (E2, E1) inputs. When the device select code is
received, the memory device only responds if the Chip Enable Address is the same as the
value decoded on the E2, E1 inputs.
The 8th bit is the Read/Write bit (RW). This bit is set to 1 for Read and 0 for Write operations.
Table 2. Device select code
Chip Enable
address(2)
Device type identifier(1)
When accessing
the memory
When accessing
the Identification
page
Address
bit
RW
b7
b6
b5
b4
b3
b2
b1
b0
1
0
1
0
E2
E1
A16
RW
1
0
1
1
E2
E1
X(3)
RW
1. The most significant bit, b7, is sent first.
2. E2 and E1 bits are compared with the value read on input pins E2,E1.
3. X = don’t care.
If a match occurs on the device select code, the corresponding memory device gives an
acknowledgment on Serial Data (SDA) during the 9th bit time. If the memory device does not
match the device select code, it deselects itself from the bus, and goes into Standby mode.
Once the memory device has acknowledged the device select code (Table 2), the memory
device waits for the master to send two address bytes (most significant address byte sent
first, followed by the least significant address byte (Table 3). The memory device responds
to each address byte with an acknowledge bit.
Note:
A: significant address bit.
X: bit is Don’t Care.
12/37
DocID023765 Rev 4
M24M01-A125
Device operation
Table 3. Address significant bits
Memory(1) (2)
Identification page
(Device type identifier =
1010b)
Lower address byte
Upper address byte
Device
Select
bit 1
(Device type identifier = 1011b)
Random
Address
Read
Write
Read
Identification
page
Write
Identification
page
Lock
Identification
page
Read
lock
status
b16
A16
A16
X
X
X
X
b15
A15
A15
X
X
X
X
b14
A14
A14
X
X
X
X
b13
A13
A13
X
X
X
X
b12
A12
A12
X
X
X
X
b11
A11
A11
X
X
X
X
b10
A10
A10
X
0
1
0
b9
A9
A9
X
X
X
X
b8
A8
A8
X
X
X
X
b7
A7
A7
A7
A7
X
X
b6
A6
A6
A6
A6
X
X
b5
A5
A5
A5
A5
X
X
b4
A4
A4
A4
A4
X
X
b3
A3
A3
A3
A3
X
X
b2
A2
A2
A2
A2
X
X
b1
A1
A1
A1
A1
X
X
b0
A0
A0
A0
A0
X
X
1. A: significant address bit.
2. X: bit is Don’t Care.
DocID023765 Rev 4
13/37
36
Device operation
3.6
M24M01-A125
Identification page
The M24M01-A125 offers an Identification Page (256 bytes) in addition to the 1 Mb memory.
The Identification page contains two fields:
Note:
•
Device identification code: the first three bytes are programmed by STMicroelectronics
with the Device identification code, as shown in Table 4.
•
Application parameters: the bytes after the Device identification code are available for
application specific data.
If the end application does not need to read the Device identification code, this field can be
overwritten and used to store application-specific data. Once the application-specific data
are written in the Identification page, the whole Identification page should be permanently
locked in Read-only mode.
The instructions Read, Write and Lock Identification Page are detailed in Section 4:
Instructions.
Table 4. Device identification code
Address in
Identification page
00h
14/37
Content
ST manufacturer code
2C
family code
01h
I
02h
Memory density code
DocID023765 Rev 4
Value
20h
E0h
11h (1024 Kbit)
M24M01-A125
4
Instructions
4.1
Write operations
Instructions
For a Write operation, the bus master sends a Start condition followed by a device select
code with the R/W bit reset to 0. The device acknowledges this, as shown in Figure 5, and
waits for the master to send two address bytes (most significant address byte sent first,
followed by the least significant address byte (Table 3). The device responds to each
address byte with an acknowledge bit, and then waits for the data byte.
The 128 Kbytes (1 Mb) are addressed with 17 address bits, the 16 lower address bits being
defined by the two address bytes and the most significant address bit (A16) being included
in the Device Select code (see Table 2).
When the bus master generates a Stop condition immediately after a data byte Ack bit (in
the “10th bit” time slot), either at the end of a Byte Write or a Page Write, the internal Write
cycle tW is then triggered. A Stop condition at any other time slot does not trigger the internal
Write cycle.
During the internal Write cycle, Serial Data (SDA) is disabled internally, and the device does
not respond to any requests.
After the successful completion of an internal Write cycle (tW), the device internal address
counter is automatically incremented to point to the next byte after the last modified byte.
If the Write Control input (WC) is driven High, the Write instruction is not executed and the
accompanying data bytes are not acknowledged, as shown in Figure 6.
DocID023765 Rev 4
15/37
36
Instructions
4.1.1
M24M01-A125
Byte Write
After the device select code and the address bytes, the bus master sends one data byte. If
the addressed location is Write-protected, by Write Control (WC) being driven high, the
device replies with NoAck, and the location is not modified (see Figure 6). If, instead, the
addressed location is not Write-protected, the device replies with Ack. The bus master
terminates the transfer by generating a Stop condition, as shown in Figure 5.
Figure 5. Write mode sequences with WC = 0 (data write enabled)
7#
!#+
!#+
"YTE ADDR
"YTE ADDR
!#+
$ATA IN
3TOP
$EV SEL
3TART
"YTE 7RITE
!#+
27
7#
!#+
"YTE ADDR
$EV SEL
3TART
0AGE 7RITE
!#+
!#+
"YTE ADDR
!#+
$ATA IN $ATA IN 27
7# CONTgD
!#+
$ATA IN .
3TOP
0AGE 7RITE CONTgD
!#+
16/37
DocID023765 Rev 4
!)D
M24M01-A125
Page Write
The Page Write mode allows up to N(a) bytes to be written in a single Write cycle, provided
that they are all located in the same page in the memory: that is, the most significant
memory address bits, A16/A8, are the same. If more bytes are sent than will fit up to the end
of the page, a condition known as “roll-over” occurs. In case of roll-over, the first bytes of the
page are overwritten.
The bus master sends from 1 to N(a) bytes of data, each of which is acknowledged by the
device if Write Control (WC) is low. If Write Control (WC) is high, the contents of the
addressed memory location are not modified, and each data byte received by the device is
not acknowledged, as shown in Figure 6. After each byte is transferred, the internal byte
address counter is incremented. The transfer is terminated by the bus master generating a
Stop condition.
Figure 6. Write mode sequences with WC = 1 (data write inhibited)
7#
!#+
!#+
"YTE ADDR
!#+
"YTE ADDR
./ !#+
$ATA IN
3TOP
$EV SEL
3TART
"YTE 7RITE
27
7#
!#+
0AGE 7RITE
$EV SEL
3TART
!#+
"YTE ADDR
!#+
"YTE ADDR
./ !#+
$ATA IN $ATA IN 27
7# CONTgD
./ !#+
0AGE 7RITE CONTgD
./ !#+
$ATA IN .
3TOP
4.1.2
Instructions
!)D
a. N is the number of bytes in a page.
DocID023765 Rev 4
17/37
36
Instructions
4.1.3
M24M01-A125
Write Identification Page
The Identification Page (256 bytes) is an additional page which can be written and (later)
permanently locked in Read-only mode. It is written by issuing the Write Identification Page
instruction. This instruction uses the same protocol and format as Page Write (into memory
array), except for the following differences:
•
Device type identifier = 1011b
•
Most significant address bits A16/A8 are don't care, except for address bit A10 which
must be “0”. Least significant address bits A7/A0 define the byte location inside the
Identification page.
If the Identification page is locked, the data bytes transferred during the Write Identification
Page instruction are not acknowledged (NoAck).
4.1.4
Lock Identification Page
The Lock Identification Page instruction (Lock ID) permanently locks the Identification page
in Read-only mode. The Lock ID instruction is similar to Byte Write (into memory array) with
the following specific conditions:
4.1.5
•
Device type identifier = 1011b
•
Address bit A10 must be ‘1’; all other address bits are don't care
•
The data byte must be equal to the binary value xxxx xx1x, where x is don't care
Minimizing Write delays by polling on ACK
The maximum Write time (tw) is shown in AC characteristics tables in Section 8: DC and AC
parameters, but the typical time is shorter. To make use of this, a polling sequence can be
used by the bus master.
The sequence, as shown in Figure 7, is:
18/37
•
Initial condition: a Write cycle is in progress.
•
Step 1: the bus master issues a Start condition followed by a device select code (the
first byte of the new instruction).
•
Step 2: if the device is busy with the internal Write cycle, no Ack will be returned and
the bus master goes back to Step 1. If the device has terminated the internal Write
cycle, it responds with an Ack, indicating that the device is ready to receive the second
part of the instruction (the first byte of this instruction having been sent during Step 1).
DocID023765 Rev 4
M24M01-A125
Instructions
Figure 7. Write cycle polling flowchart using ACK
:ULWHF\FOH
LQSURJUHVV
6WDUWFRQGLWLRQ
'HYLFHVHOHFW
ZLWK5: 12
)LUVWE\WHRILQVWUXFWLRQ
ZLWK5: DOUHDG\
GHFRGHGE\WKHGHYLFH
$&.
UHWXUQHG
<(6
12
1H[W
2SHUDWLRQLV
DGGUHVVLQJWKH
PHPRU\
<(6
6HQG$GGUHVV
DQG5HFHLYH$&.
5H6WDUW
6WRS
12
6WDUW&RQGLWLRQ
<(6
'DWDIRUWKH
:ULWHFSHUDWLRQ
$EVICE SELECT
WITH 27 &RQWLQXHWKH
:ULWHRSHUDWLRQ
&RQWLQXHWKH
5DQGRP5HDGRSHUDWLRQ
!)E
$,G
DocID023765 Rev 4
19/37
36
Instructions
4.2
M24M01-A125
Read operations
Read operations are performed independently of the state of the Write Control (WC) signal.
After the successful completion of a Read operation, the device internal address counter is
incremented by one, to point to the next byte address.
Figure 8. Read mode sequences
!#+
$ATA OUT
3TOP
3TART
$EV SEL
./ !#+
27
!#+
2ANDOM
!DDRESS
2EAD
"YTE ADDR
$EV SEL
!#+
./ !#+
$ATA OUT .
27
!#+
!#+
"YTE ADDR
!#+
"YTE ADDR
27
!#+
$EV SEL
3TART
3TART
$EV SEL
!#+
$ATA OUT
27
!#+
$ATA OUT ./ !#+
3TOP
3TART
$EV SEL
3EQUENTIAL
2ANDOM
2EAD
!#+
"YTE ADDR
27
!#+
3EQUENTIAL
#URRENT
2EAD
!#+
3TART
3TART
$EV SEL
!#+
3TOP
#URRENT
!DDRESS
2EAD
!#+
$ATA OUT
27
./ !#+
3TOP
$ATA OUT .
4.2.1
!)E
Random Address Read
The Random Address Read is a sequence composed of a truncated Write sequence (to
define a new address pointer value, see Table 3) followed by a current Read.
The Random Address Read sequence is therefore the sum of [Start + Device Select code
with RW=0 + two address bytes] (without Stop condition, as shown in Figure 8)] and [Start
condition + Device Select code with RW=1]. The memory device acknowledges the
sequence and then outputs the contents of the addressed byte. To terminate the data
transfer, the bus master does not acknowledge the last data byte and then issues a Stop
condition.
20/37
DocID023765 Rev 4
M24M01-A125
4.2.2
Instructions
Current Address Read
For the Current Address Read operation, following a Start condition, the bus master only
sends a device select code with the R/W bit set to 1. The device acknowledges this, and
outputs the byte pointed by the internal address counter. The counter is then incremented.
The bus master terminates the transfer with a Stop condition, as shown in Figure 8, without
acknowledging the byte.
Note that the address counter value is defined by instructions accessing either the memory
or the Identification page. When accessing the Identification page, the address counter
value is loaded with the Identification page byte location, when accessing the memory, it is
safer to always use the Random Address Read instruction (this instruction loads the
address counter with the byte location to read in the memory) instead of the Current
Address Read instruction.
4.2.3
Sequential Read
A sequential Read can be used after a Current Address Read or a Random Address Read.
After a Read instruction, the device can continue to output the next byte(s) in sequence if
the bus master sends additional clock pulses and if the bus master does acknowledge each
transmitted data byte. To terminate the stream of bytes, the bus master must not
acknowledge the last byte, and must generate a Stop condition, as shown in Figure 8.
The sequential read is controlled with the device internal address counter which is
automatically incremented after each byte output. After the last memory address, the
address counter “rolls-over”, and the device continues to output data from memory address
00h.
4.2.4
Read Identification Page
The Identification Page can be read by issuing a Read Identification Page instruction. This
instruction uses the same protocol and format as the Random Address Read (from memory
array) with device type identifier defined as 1011b. The most significant address bits A16/A8
are don't care and the least significant address bits A7/A0 define the byte location inside the
Identification page. The number of bytes to read in the ID page must not exceed the page
boundary.
4.2.5
Read the lock status
The locked/unlocked status of the Identification page can be checked by transmitting a
specific truncated command [Identification Page Write instruction + one data byte] to the
device. The device returns an acknowledge bit after the data byte if the Identification page is
unlocked, otherwise a NoAck bit if the Identification page is locked.
Right after this, it is recommended to transmit to the device a Start condition followed by a
Stop condition, so that:
•
Start: the truncated command is not executed because the Start condition resets the
device internal logic,
•
Stop: the device is then set back into Standby mode by the Stop condition.
DocID023765 Rev 4
21/37
36
Instructions
4.2.6
M24M01-A125
Acknowledge in Read mode
For all Read instructions, the device waits, after each byte sent out, for an acknowledgment
during the 9th bit time. If the bus master does not send the Acknowledge (the master drives
SDA high during the 9th bit time), the device terminates the data transfer and enters its
Standby mode.
22/37
DocID023765 Rev 4
M24M01-A125
Application design recommendations
5
Application design recommendations
5.1
Supply voltage
5.1.1
Operating supply voltage (VCC)
Prior to selecting the memory and issuing instructions to it, a valid and stable VCC voltage
within the specified [VCC(min), VCC(max)] range must be applied (see Table 7).
This voltage must remain stable and valid until the end of the transmission of the instruction
and, for a Write instruction, until the completion of the internal Write cycle (tW). In order to
secure a stable DC supply voltage, it is recommended to decouple the VCC line with a
suitable capacitor (usually of the order of 10 nF to 100 nF) close to the VCC/VSS package
pins.
5.1.2
Power-up conditions
When the power supply is turned on, the VCC voltage has to rise continuously from 0 V up to
the minimum VCC operating voltage defined in Table 7.
In order to prevent inadvertent write operations during power-up, a power-on-reset (POR)
circuit is included.
At power-up, the device does not respond to any instruction until VCC reaches the internal
threshold voltage (this threshold is defined in the DC characteristic Table 10 as VRES).
When VCC passes over the POR threshold, the device is reset and in the following state:
•
in the Standby power mode
•
deselected
As soon as the VCC voltage has reached a stable value within the [VCC(min), VCC(max)]
range (defined in Table 7), the device is ready for operation.
5.1.3
Power-down
During power-down (continuous decrease in the VCC supply voltage below the minimum
VCC operating voltage defined in Table 7), the device must be in Standby power mode (that
is after a STOP condition or after the completion of the Write cycle tW if an internal Write
cycle is in progress).
DocID023765 Rev 4
23/37
36
Application design recommendations
5.2
M24M01-A125
Cycling with Error Correction Code (ECC)
The Error Correction Code (ECC) is an internal logic function which is transparent for the
I2C communication protocol.
The ECC logic is implemented on each group of four EEPROM bytes(b). Inside a group, if a
single bit out of the four bytes happens to be erroneous during a Read operation, the ECC
detects this bit and replaces it with the correct value. The read reliability is therefore much
improved.
Even if the ECC function is performed on groups of four bytes, a single byte can be
written/cycled independently. In this case, the ECC function also writes/cycles the three
other bytes located in the same group(b). As a consequence, the maximum cycling budget is
defined at group level and the cycling can be distributed over the 4 bytes of the group: the
sum of the cycles seen by byte0, byte1, byte2 and byte3 of the same group must remain
below the maximum value defined in Table 6.
Example 1: maximum cycling limit reached with 1 million cycles per byte
Each byte of a group can be equally cycled 1 million times (at 25 °C) so that the group
cycling budget is 4 million cycles.
Example 2: maximum cycling limit reached with unequal byte cycling
Inside a group, byte0 can be cycled 2 million times, byte1 can be cycled 1 million times,
byte2 and byte3 can be cycled 500,000 times, so that the group cycling budget is 4 million
cycles.
b. A group of four bytes is located at addresses [4*N, 4*N+1, 4*N+2, 4*N+3], where N is an integer.
24/37
DocID023765 Rev 4
M24M01-A125
6
Delivery state
Delivery state
The device is delivered as follows:
7
•
The memory array is set to all 1s (each byte = FFh).
•
Identification page: the first three bytes define the Device identification code (value
defined in Table 4). The content of the following bytes is Don’t Care.
Maximum rating
Stressing the device outside the ratings listed in Table 5 may cause permanent damage to
the device. These are stress ratings only, and operation of the device at these, or any other
conditions outside those indicated in the operating sections of this specification, is not
implied. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
Table 5. Absolute maximum ratings
Symbol
TSTG
TLEAD
Parameter
Min.
Max.
Unit
Ambient operating temperature
–40
130
°C
Storage temperature
–65
150
°C
(1)
°C
–0.50
6.5
V
-
5
mA
–0.50
6.5
V
-
4000
V
Lead temperature during soldering
VIO
Input or output range
IOL
DC output current (SDA = 0)
VCC
Supply voltage
VESD
Electrostatic pulse (Human Body
model)(2)
see note
1. Compliant with JEDEC Standard J-STD-020D (for small body, Sn-Pb or Pb-free assembly), the ST
ECOPACK® 7191395 specification, and the European directive on Restrictions of Hazardous Substances
(RoHS directive 2011/65/EUof July 2011).
2. Positive and negative pulses applied on pin pairs, according to AEC-Q100-002 (compliant with JEDEC Std
JESD22-A114, C1=100 pF, R1=1500 Ω, R2=500 Ω).
DocID023765 Rev 4
25/37
36
DC and AC parameters
8
M24M01-A125
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Table 6. Cycling performance by groups of four bytes
Symbol
Ncycle
Parameter
Test condition
Min.
Max.
TA ≤ 25 °C, 2.5 V < VCC < 5.5 V
-
4,000,000
Write cycle endurance(1) TA = 85 °C, 2.5 V < VCC < 5.5 V
-
1,200,000
-
600,000
TA = 125 °C, 2.5 V < VCC < 5.5 V
Unit
Write
cycle(2)
1. The Write cycle endurance is defined for groups of four data bytes located at addresses [4*N, 4*N+1, 4*N+2, 4*N+3] where
N is an integer, or for the status register byte (refer also to Section 5.2: Cycling with Error Correction Code (ECC)). The
Write cycle endurance is defined by characterization and qualification.
2. A Write cycle is executed when either a Page Write, a Byte Write, a Write Identification Page or a Lock Identification Page
instruction is decoded. When using those Write instructions, refer also to Section 5.2: Cycling with Error Correction Code
(ECC).
Table 7. Operating conditions (voltage range W)
Symbol
VCC
TA
Parameter
Min.
Max.
Unit
Supply voltage
2.5
5.5
V
Ambient operating temperature
–40
125
°C
Max.
Unit
Table 8. AC measurement conditions
Symbol
Cbus
26/37
Parameter
Min.
Load capacitance
100
-
SCL input rise/fall time, SDA input fall time
-
Input levels
0.2 VCC to 0.8 VCC
V
-
Input and output timing reference levels
0.3 VCC to 0.7 VCC
V
DocID023765 Rev 4
-
pF
50
ns
M24M01-A125
DC and AC parameters
Figure 9. AC measurement I/O waveform
)NPUT VOLTAGE LEVELS
)NPUT AND OUTPUT
4IMING REFERENCE LEVELS
6##
6##
6##
6##
-36
Table 9. Input parameters
Symbol
Parameter(1)
Test condition
Min.
Max.
Unit
CIN
Input capacitance (SDA)
-
-
8
pF
CIN
Input capacitance (other pins)
-
-
6
pF
VIN < 0.3 VCC
30
-
kΩ
VIN > 0.7 VCC
500
-
kΩ
ZL
ZH
Input impedance (E2, E1, WC)(2)
1. Characterized only, not tested in production.
2. E2, E1 input impedance when the memory is selected (after a Start condition).
DocID023765 Rev 4
27/37
36
DC and AC parameters
M24M01-A125
Table 10. DC characteristics
Symbol
Test conditions (in addition to
those in Table 7 and Table 8)
Parameter
Min.
Max.
Unit
ILI
Input leakage current
(SCL, SDA, E2, E1)
VIN = VSS or VCC,
device in Standby mode
-
±2
µA
ILO
Output leakage current
SDA in Hi-Z, external voltage
applied on SDA: VSS or VCC
-
±2
µA
fC = 400 kHz, VCC = 5.5 V
-
2
mA
fC = 400 kHz, VCC = 2.5 V
-
2
mA
fC = 1 MHz, VCC = 5.5 V
-
2
mA
fC = 1 MHz, VCC = 2.5 V
-
2
mA
During tW
-
2
mA
Device not
t° = 85 °C
VIN = VSS or VCC , VCC = 2.5 V
-
2
µA
Device not selected(1), t° = 85 °C,
VIN = VSS or VCC, VCC = 5.5 V
-
3
µA
Device not selected(1), t° = 125 °C,
VIN = VSS or VCC, VCC = 2.5 V
-
15
µA
Device not selected(1), t° = 125 °C,
VIN = VSS or VCC, VCC = 5.5 V
-
20
µA
ICC
ICC0
Supply current (Read)
Supply current (Write)
selected(1),
ICC1
VIL
VIH
VOL
VRES (2)
Standby supply current
Input low voltage (SCL, SDA, WC)
-
–0.45
0.3 VCC
V
Input high voltage (SCL, SDA)
-
0.7 VCC
6.5
V
Input high voltage (WC, E2, E1)
-
0.7 VCC VCC +0.6
Output low voltage
IOL = 2.1 mA, VCC = 2.5 V or
IOL = 3 mA, VCC = 5.5 V
Internal reset threshold voltage
-
V
-
0.4
V
0.5
1.5
V
1. The device is not selected after power-up, after a Read instruction (after the Stop condition), or after the completion of the
internal write cycle tW (tW is triggered by the correct decoding of a Write instruction).
2. Characterized only, not 100% tested.
28/37
DocID023765 Rev 4
M24M01-A125
DC and AC parameters
Table 11. 400 kHz AC characteristics
Parameter(1)
Symbol
Alt.
fC
fSCL
Clock frequency
tCHCL
tHIGH
tCLCH
tQL1QL2(2)
tXH1XH2
Min.
Max.
Unit
-
400
kHz
Clock pulse width high
600
-
ns
tLOW
Clock pulse width low
1300
-
ns
tF
SDA (out) fall time(3)
20
120
ns
Input signal rise time
(4)
(4)
ns
(4)
(4)
ns
100
-
ns
0
-
ns
100
-
ns
-
900
ns
tR
tXL1XL2
tF
Input signal fall time
tDXCX
tSU:DAT
Data in set up time
tCLDX
tHD:DAT
Data in hold time
tCLQX(5)
tDH
Data out hold time
tCLQV(6)
tAA
Clock low to next data valid (access time)
tCHDL
tSU:STA
Start condition setup time
600
-
ns
tDLCL
tHD:STA
Start condition hold time
600
-
ns
tCHDH
tSU:STO
Stop condition set up time
600
-
ns
tDHDL
tBUF
Time between Stop condition and next Start
condition
1300
-
ns
tWLDL(7)(2)
tSU:WC
WC set up time (before the Start condition)
0
-
µs
(8)(2)
tHD:WC
WC hold time (after the Stop condition)
1
-
µs
Write time
-
4
ms
Pulse width ignored (input filter on SCL and
SDA) - single glitch
-
80
ns
tDHWH
tW
tWR
tNS(2)
-
1. Test conditions (in addition to those in Table 7 and Table 8).
2. Characterized value, not tested in production.
3. With CL = 10 pF.
4. There is no min. or max. values for the input signal rise and fall times. It is however recommended by the
I²C specification that the input signal rise and fall times be more than 20 ns and less than 300 ns when
fC < 400 kHz.
5. To avoid spurious Start and Stop conditions, a minimum delay is placed between SCL=1 and the falling or
rising edge of SDA.
6. tCLQV is the time (from the falling edge of SCL) required by the SDA bus line to reach either 0.3VCC or
0.7VCC, assuming that Rbus × Cbus time constant is within the values specified in Figure 10.
7. WC=0 set up time condition to enable the execution of a WRITE command.
8. WC=0 hold time condition to enable the execution of a WRITE command.
DocID023765 Rev 4
29/37
36
DC and AC parameters
M24M01-A125
Table 12. 1 MHz AC characteristics
Parameter(1)
Symbol
Alt.
Min.
Max.
Unit
fC
fSCL
Clock frequency
0
1
MHz
tCHCL
tHIGH
Clock pulse width high
260
-
ns
tCLCH
tLOW
Clock pulse width low
400
-
ns
tXH1XH2
tR
Input signal rise time
(2)
(2)
ns
(2)
(2)
ns
tXL1XL2
tF
Input signal fall time
tQL1QL2(3)
tF
SDA (out) fall time
-
120
ns
tDXCX
tSU:DAT
Data in setup time
50
-
ns
tCLDX
tHD:DAT Data in hold time
0
-
ns
100
-
ns
-
450
ns
tCLQX(4)
tDH
Data out hold time
tCLQV(5)
tAA
Clock low to next data valid (access time)
tCHDL
tSU:STA
Start condition setup time
250
-
ns
tDLCL
tHD:STA
Start condition hold time
250
-
ns
tCHDH
tSU:STO Stop condition setup time
250
-
ns
tDHDL
tBUF
Time between Stop condition and next Start
condition
500
-
ns
tWLDL(6) (3)
tSU:WC
WC set up time (before the Start condition)
0
-
µs
tDHWH(7)
(3)
tHD:WC
WC hold time (after the Stop condition)
1
-
µs
tW
tWR
Write time
-
4
ms
tNS(3)
-
Pulse width ignored (input filter on SCL and
SDA)
-
80
ns
1. Test conditions (in addition to those in Table 7 and Table 8).
2. There is no min. or max. values for the input signal rise and fall times. However, it is recommended by the
I²C specification that the input signal rise and fall times be more than 20 ns and less than 120 ns when
fC < 1 MHz.
3. Characterized only, not tested in production.
4. To avoid spurious Start and Stop conditions, a minimum delay is placed between SCL=1 and the falling or
rising edge of SDA.
5. tCLQV is the time (from the falling edge of SCL) required by the SDA bus line to reach either 0.3 VCC or
0.7 VCC, assuming that the Rbus × Cbus time constant is within the values specified in Figure 11.
6. WC=0 set up time condition to enable the execution of a WRITE command.
7. WC=0 hold time condition to enable the execution of a WRITE command.
30/37
DocID023765 Rev 4
M24M01-A125
DC and AC parameters
Figure 10. Maximum Rbus value versus bus parasitic capacitance (Cbus) for an I2C
bus at maximum frequency fC = 400 kHz
"US LINE PULL UP RESISTOR
K
K½
4HE 2 BUS X #BUS TIME CONSTANT
MUST BE BELOW THE NS
TIME CONSTANT LINE REPRESENTED
ON THE LEFT
2
BU
S §
#
BU
S (ERE 2BUS § #BUS NS
6##
2BUS
N
S
)£# BUS
MASTER
3#,
-XXX
3$!
P&
"US LINE CAPACITOR P&
#BUS
AIB
Figure 11. Maximum Rbus value versus bus parasitic capacitance Cbus) for an I2C
bus at maximum frequency fC = 1MHz
"US LINE PULL UP RESISTOR K
6##
4HE 2BUS § #BUS TIME CONSTANT
MUST BE BELOW THE NS
TIME CONSTANT LINE REPRESENTED
ON THE LEFT
2
BUS §
#
BUS NS
2BUS
)£# BUS
MASTER
3#,
-XXX
3$!
(ERE
2 BUS § #BUS NS
#BUS
"US LINE CAPACITOR P&
-36
DocID023765 Rev 4
31/37
36
DC and AC parameters
M24M01-A125
Figure 12. AC waveforms
^ƚĂƌƚ
ĐŽŶĚŝƚŝŽŶ
^ƚŽƉ
ĐŽŶĚŝƚŝŽŶ
ƚy>ϭy>Ϯ
ƚy,ϭy,Ϯ
ƚ,>
^ƚĂƌƚ
ĐŽŶĚŝƚŝŽŶ
ƚ>,
^>
ƚ>>
ƚy>ϭy>Ϯ
^/Ŷ
ƚ,>
ƚy,ϭy,Ϯ
^
/ŶƉƵƚ
ƚy,
^
ŚĂŶŐĞ
ƚ>y
ƚ,,
ƚ,>
t
ƚ,t,
ƚt>>
^ƚŽƉ
ĐŽŶĚŝƚŝŽŶ
^ƚĂƌƚ
ĐŽŶĚŝƚŝŽŶ
^>
^/Ŷ
ƚt
ƚ,,
ƚ,>
tƌŝƚĞĐLJĐůĞ
ƚ,>
^>
ƚ>Ys
^KƵƚ
32/37
ƚ>Yy
ĂƚĂǀĂůŝĚ
ĂƚĂǀĂůŝĚ
DocID023765 Rev 4
ƚY>ϭY>Ϯ
/ϬϬϳϵϱŝ
M24M01-A125
9
Package mechanical data
Package mechanical data
In order to meet environmental requirements, ST offers these devices in different grades of
ECOPACK® packages, depending on their level of environmental compliance. ECOPACK®
specifications, grade definitions and product status are available at: www.st.com.
ECOPACK® is an ST trademark.
Figure 13. TSSOP8 – 8-lead thin shrink small outline, package outline
1. Drawing is not to scale.
Table 13. TSSOP8 – 8-lead thin shrink small outline, package mechanical data
inches(1)
millimeters
Symbol
Typ.
Min.
Max.
Typ.
Min.
Max.
A
-
-
1.200
-
-
0.0472
A1
-
0.050
0.150
-
0.0020
0.0059
A2
1.000
0.800
1.050
0.0394
0.0315
0.0413
b
-
0.190
0.300
-
0.0075
0.0118
c
-
0.090
0.200
-
0.0035
0.0079
CP
-
0.100
-
-
0.0039
D
3.000
2.900
3.100
0.1181
0.1142
0.1220
e
0.650
-
-
0.0256
-
-
E
6.400
6.200
6.600
0.2520
0.2441
0.2598
E1
4.400
4.300
4.500
0.1732
0.1693
0.1772
L
0.600
0.450
0.750
0.0236
0.0177
0.0295
L1
1.000
-
-
0.0394
-
-
α
-
0°
8°
-
0°
8°
1. Values in inches are converted from mm and rounded to four decimal digits.
DocID023765 Rev 4
33/37
36
Package mechanical data
M24M01-A125
Figure 14. SO8N – 8 lead plastic small outline, 150 mils body width, package outline
K[ƒ
$
$
F
FFF
E
H
PP
*$8*(3/$1(
'
N
(
(
/
$
/
62$
1. Drawing is not to scale.
Table 14. SO8N – 8 lead plastic small outline, 150 mils body width, package data
inches (1)
millimeters
Symbol
Typ
Min
Max
Typ
Min
Max
A
-
-
1.750
-
-
0.0689
A1
-
0.100
0.250
-
0.0039
0.0098
A2
-
1.250
-
-
0.0492
-
b
-
0.280
0.480
-
0.0110
0.0189
c
-
0.170
0.230
-
0.0067
0.0091
ccc
-
-
0.100
-
-
0.0039
D
4.900
4.800
5.000
0.1929
0.1890
0.1969
E
6.000
5.800
6.200
0.2362
0.2283
0.2441
E1
3.900
3.800
4.000
0.1535
0.1496
0.1575
e
1.270
-
-
0.0500
-
-
h
-
0.250
0.500
-
0.0098
0.0197
k
-
0°
8°
-
0°
8°
L
-
0.400
1.270
-
0.0157
0.0500
L1
1.040
-
-
0.0409
-
-
1. Values in inches are converted from mm and rounded to four decimal digits.
34/37
DocID023765 Rev 4
M24M01-A125
10
Part numbering
Part numbering
Table 15. Ordering information scheme
Example:
M24M01-D
W MN 3
T
P /K
Device type
M24 = I2C serial access EEPROM
Device function
M01-D = 1 Mbit (128 K x 8 bits) plus identification page
Operating voltage
W = VCC = 2.5 V to 5.5 V
Package
MN = SO8 (150 mil width)(1)
DW = TSSOP8 (169 mil width)(1)
Device grade
3 = -40 to 125 °C. Device tested with high reliability certified flow(2)
Option
blank = standard packing
T = Tape and reel packing
Plating technology
P = ECOPACK® (RoHS compliant)
Process
/K = Manufacturing technology code
1. RoHS-compliant and halogen-free (ECOPACK2®)
2. The high reliability certified flow (HRCF) is described in quality note QNEE9801. Please ask your nearest
ST sales office for a copy.
For a list of available options (speed, package, etc.) or for further information on any aspect
of the devices, please contact your nearest ST sales office.
DocID023765 Rev 4
35/37
36
Revision history
11
M24M01-A125
Revision history
Table 16. Document revision history
36/37
Date
Revision
Changes
24-Jan-2013
1
Initial release.
27-May-2013
2
Document reformatted.
Document status changed from “Target specification” to “Preliminary
data”.
Updated:
– Section 3.6: Identification page
– Note (1) under Table 5: Absolute maximum ratings
– ICC ,VIL and VOL values in Table 10: DC characteristics
– Package information in Table 15: Ordering information scheme
Removed information related to UFDFPN8 (MLP8) package.
19-Aug-2013
3
Document status changed from “Preliminary data” to “Production
data”.
Updated “VOL” row in Table 10: DC characteristics.
04-Feb-2014
4
Changed Data retention from "40 years at 55 °C" to "50 years at
125 °C" in Features.
DocID023765 Rev 4
M24M01-A125
Please Read Carefully:
Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the
right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any
time, without notice.
All ST products are sold pursuant to ST’s terms and conditions of sale.
Purchasers are solely responsible for the choice, selection and use of the ST products and services described herein, and ST assumes no
liability whatsoever relating to the choice, selection or use of the ST products and services described herein.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this
document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products
or services, or any intellectual property contained therein or considered as a warranty covering the use in any manner whatsoever of such
third party products or services or any intellectual property contained therein.
UNLESS OTHERWISE SET FORTH IN ST’S TERMS AND CONDITIONS OF SALE ST DISCLAIMS ANY EXPRESS OR IMPLIED
WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF ST PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED
WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS
OF ANY JURISDICTION), OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
ST PRODUCTS ARE NOT DESIGNED OR AUTHORIZED FOR USE IN: (A) SAFETY CRITICAL APPLICATIONS SUCH AS LIFE
SUPPORTING, ACTIVE IMPLANTED DEVICES OR SYSTEMS WITH PRODUCT FUNCTIONAL SAFETY REQUIREMENTS; (B)
AERONAUTIC APPLICATIONS; (C) AUTOMOTIVE APPLICATIONS OR ENVIRONMENTS, AND/OR (D) AEROSPACE APPLICATIONS
OR ENVIRONMENTS. WHERE ST PRODUCTS ARE NOT DESIGNED FOR SUCH USE, THE PURCHASER SHALL USE PRODUCTS AT
PURCHASER’S SOLE RISK, EVEN IF ST HAS BEEN INFORMED IN WRITING OF SUCH USAGE, UNLESS A PRODUCT IS
EXPRESSLY DESIGNATED BY ST AS BEING INTENDED FOR “AUTOMOTIVE, AUTOMOTIVE SAFETY OR MEDICAL” INDUSTRY
DOMAINS ACCORDING TO ST PRODUCT DESIGN SPECIFICATIONS. PRODUCTS FORMALLY ESCC, QML OR JAN QUALIFIED ARE
DEEMED SUITABLE FOR USE IN AEROSPACE BY THE CORRESPONDING GOVERNMENTAL AGENCY.
Resale of ST products with provisions different from the statements and/or technical features set forth in this document shall immediately void
any warranty granted by ST for the ST product or service described herein and shall not create or extend in any manner whatsoever, any
liability of ST.
ST and the ST logo are trademarks or registered trademarks of ST in various countries.
Information in this document supersedes and replaces all information previously supplied.
The ST logo is a registered trademark of STMicroelectronics. All other names are the property of their respective owners.
© 2014 STMicroelectronics - All rights reserved
STMicroelectronics group of companies
Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan Malaysia - Malta - Morocco - Philippines - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America
www.st.com
DocID023765 Rev 4
37/37
37
Similar pages