Solid State Relays for Industrial I/O G3TC Reliable SSRs for I/O Module Mounting Boards • Use I/O SSRs as an interface between logic circuitry and the load. • Variety of AC/DC input and output modules with industry-standard footprint and color coding. • Built-in hold down screw fastens relay to board to eliminate loosening by vabration. • Optical Isolation - Dielectric strength of 4 kV between input and output terminals. • Zero cross function on AC output models. • AC and DC input versions incorporate a rectifier to accept both AC or DC inputs. • UL, CSA and TUV approved; marked with CE. Ordering Information ■ Input Module Function Color AC input Isolation Yellow Photo-coupler Input operating voltage range 90-140 VDC/AC 180-280 VDC/AC DC input White 10-32 VDC/AC Logic level output supply voltage Model 5 VDC G3TC-IAC5 AC/DC120 15 VDC G3TC-IAC15 AC/DC120 24 VDC G3TC-IAC24 AC/DC120 5 VDC G3TC-IAC5A AC/DC240 15 VDC G3TC-IAC15A AC/DC240 24 VDC G3TC-IAC24A AC/DC240 5 VDC G3TC-IDC5 DC/AC24 15 VDC G3TC-IDC15 DC/AC24 24 VDC G3TC-IDC24 DC/AC24 ■ Output Module Function AC output Color Black Isolation Photo-triac Rated input voltage 5 VDC 15 VDC Rated output voltage (Applicable output voltage) 3 A at 120 VAC (3 A at 75-140 VAC) 24 VDC 5 VDC 15 VDC Red Photo-coupler 5 VDC 15 VDC 15 VDC 24 VDC G3TC-OAC15 DC15 G3TC-OAC5A DC5 G3TC-OAC15A DC15 G3TC-OAC24A DC24 3 A at 60 VDC (3 A at 5-60 VDC) 24 VDC 5 VDC G3TC-OAC5 DC5 G3TC-OAC24 DC24 3 A at 240 VAC (3 A at 75-280 VAC) 24 VDC DC output Model G3TC-ODC5 DC5 G3TC-ODC15 DC15 G3TC-ODC24 DC24 1 A at 200 VDC (1 A at 5-200 VDC) G3TC-ODC5A DC5 G3TC-ODC15A DC15 G3TC-ODC24A DC24 Solid State Relays for Industrial I/O G3TC 395 ■ Typical Applications • HVAC, refrigeration equipment • Automation controls • Injection molding machines • Packaging equipment ■ I/O Classification by Color Specifications ■ Common Characteristics Insulation resistance 100 MΩ min at 500 VDC Dielectric strength 4000 VAC, 50/60 Hz for 1 minute between input and output Vibration resistance Malfunction: 10 to 55 Hz, 1.5 mm double amplitude Shock resistance Malfunction: 1,000 m/s2 Ambient temperature Operating: -30°C to 80°C with no icing or condensation Storage: -30°C to 100°C with no icing or condensation Ambient humidity Operating: 45% to 85% Approved standards UL Recognized, CSA Certified, EN60950 396 G3TC Solid State Relays for Industrial I/O ■ AC Input Module G3TC-IAC Ratings (Ambient Temperature 25°C) Input Item G3TC-IAC5 G3TC-IAC15 G3TC-IAC24 G3TC-IAC5A G3TC-IAC15A Rated voltage 120 VAC/DC 240 VAC/DC Operating voltage 90-140 VAC/DC 180-280 VAC/DC Must operate voltage 90 VAC/DC max. 180 VAC/DC max. Must release voltage 25 VAC/DC min. 45 VAC/DC min. Input current at rated voltage 5 mA max. 5 mA max. Input resistance (see note 1) 30 kΩ 69 kΩ G3TC-IAC24A Output Item G3TC-IAC5 G3TC-IAC15 G3TC-IAC24 15 VDC 24 VDC G3TC-IAC5A 5 VDC G3TC-IAC15A 15 VDC G3TC-IAC24A Output supply voltage-nominal 5 VDC 24 VDC Output supply voltage-range 4.5-6 VDC 12-18 VDC 20-30 VDC 4.5-6 VDC 12-18 VDC 20-30 VDC Output supply current at rated input voltage (see note 2) 18 mA max. 15 mA max. 12 mA max. 18 mA max. 15 mA max. 12 mA max. Control resistance (Rc in circuit configuration - see note 1) 240 Ω 1 kΩ 2.2 kΩ 240 Ω 1k Ω 2.2k Ω Output current 50 mA max. Characteristics Item G3TC-IAC5 Operate time (see note 3) 20 ms max. Release time (see note 3) 20 ms max. Output ON voltage drop 0.4 V max. Leakage current 100 μA max. Weight Approx. 40g G3TC-IAC15 G3TC-IAC24 G3TC-IAC5A G3TC-IAC15A G3TC-IAC24A Note: 1. Resistance values are reference. 2. The input module supplies the current on I/O circuit board at nominal ouput voltage. 3. At nominal output supply voltage, rated input voltage and 25°C. ■ DC Input Module G3TC-IDC Ratings (Ambient Temperature 25°C) Input Item G3TC-IDC5 Rated voltage 24 VDC/AC Operating voltage 10-32 VDC/ 15-32 VAC Must operate voltage 10 VDC/15 VAC max. Must release voltage 3 VDC/ 3 VAC min. Input current rated voltage 25 mA max. Input resistance (see note 1) 1.5 kΩ G3TC-IDC15 G3TC-IDC24 Output Item G3TC-IDC5 G3TC-IDC15 15 VDC G3TC-IDC24 Output supply voltage-nominal 5 VDC Output supply voltage-range 4.5-6 VDC 12-18 VDC 20-30 VDC Output supply current at rated input voltage (see note 2) 18 mA max. 15 mA max. 12 mA max. 1 kΩ 2.2 kΩ Control resistance (Rc in circuit configuration - see note 1) 240 Ω Output current 24 VDC 50 mA max. Solid State Relays for Industrial I/O G3TC 397 Characteristics Item G3TC-IDC5 Operate time (see note 3) 5 ms max. Release time (see note 3) 5 ms max. Output ON voltage drop 0.4 V max. Leakage current 100 μA max. Weight Approx. 40g G3TC-IDC15 G3TC-IDC24 Note: 1. Resistance values are reference. 2. The input module supplies the current on I/O circuit board at nominal ouput voltage. 3. At nominal output supply voltage, rated input voltage and 25°C. ■ AC Output Module G3TC-OAC Ratings (Ambient Temperature 25°C) Input Item G3TC-OAC5 G3TC-OAC15 G3TC-OAC24 G3TC-OAC5A G3TC-OAC15A G3TC-OAC24A Rated voltage 5 VDC 15 VDC 24 VDC 5 VDC 15 VDC Operating voltage 2.5-8 VDC 9-16 VDC 18-32 VDC 2.5-8 VDC 9-16 VDC 18-32 VDC Must operate voltage 2.5 VDC max. 9 VDC max. 18 VDC max. 2.5 VDC max. 9 VDC max. 18 VDC max. Must release voltage 1 VDC min. Input current at rated voltage (see note 2) 18 mA max. 1 kΩ 2.2 kΩ 240 Ω 1 kΩ 2.2 kΩ Control resistance (Rc 240 Ω in circuit configuration - see note 1) 24 VDC Output Item G3TC-OAC5 G3TC-OAC15 G3TC-OAC24 G3TC-OAC5A Rated load voltage 120 VAC 240 VAC Load voltage range 75-140 VAC 75-280 VAC Load current 0.05 to 3 A Inrush current 45 A (60 Hz, 1 cycle) G3TC-OAC15A G3TC-OAC24A Characteristics Item G3TC-OAC5 G3TC-OAC15 G3TC-OAC24 Operate time (see note 3) 1/2 of load power source cycle + 1 ms max. Release time (see note 3) 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. Leakage current 2.5 mA max. (at 120 VAC) Weight Approx. 45g G3TC-OAC5A 5 mA max. (at 240 VAC) Note: 1. Resistance values are reference. 2. The output module supplies the current on I/O circuit board at nominal input voltage. 3. At nominal output supply voltage, rated input voltage and 25°C. 398 Solid State Relays for Industrial I/O G3TC-OAC15A G3TC G3TC-OAC24A ■ DC Output Module G3TC-ODC Ratings (Ambient Temperature 25°C) Input Item G3TC-ODC5 G3TC-ODC15 G3TC-ODC24 5 VDC G3TC-ODC15A 15 VDC G3TC-ODC24A 5 VDC 15 VDC Operating voltage 2.5-8 VDC 9-16 VDC 18-32 VDC 2.5-8 VDC 9-16 VDC 18-32 VDC Must operate voltage 2.5 VDC max. 9 VDC max. 18 VDC max. 2.5 VDC max. 9 VDC max. 18 VDC max. Must release voltage 1 VDC min. Input current at rated voltage (see note 2) 18 mA max. 1 kΩ 2.2 kΩ 240 Ω 1 kΩ 2.2 kΩ Control resistance (Rc 240 Ω in circuit configuration - see note 1) 24 VDC G3TC-ODC5A Rated voltage 24 VDC Output Item G3TC-ODC5 G3TC-ODC15 G3TC-ODC24 G3TC-ODC5A Rated load voltage 60 VDC 200 VDC Load voltage range 5-60 VDC 5-200 VDC Load current 0.01 to 3 A 0.01 to 1.0 A Inrush current 18 A (10 ms) 9 A (10 ms) G3TC-ODC15A G3TC-ODC24A Characteristics Item G3TC-ODC5 G3TC-ODC15 G3TC-ODC24 G3TC-ODC5A G3TC-ODC15A Operate time (see note 3) 50 μs max. 100 μs max. Release time (see note 3) 50 μs max. (see note 4) 750 μs max. Output ON voltage drop 1.6 V max. Leakage current 1 mA max. (at 60 VDC) 1 mA max. (at 200 VDC) Weight Approx. 45g Approx. 40g Note: 1. 2. 3. 4. G3TC-ODC24A Resistance values are reference. The output module supplies the current on I/O circuit board at nominal input voltage. At rated load voltage, maximum rated load current, rated input voltage and 25°C. At 24 VDC load voltage, 3 A load current and 25°C. Solid State Relays for Industrial I/O G3TC 399 Engineering Data ■ Internal Circuit G3TC-IAC/IDC G3TC-OAC AC Output AC/DC Input In Out - Out In - - Note: Internal biasing circuitry is different between AC input and DC input modules G3TC-ODC DC Output Out - In - 400 Solid State Relays for Industrial I/O G3TC ■ Load Current vs. Ambient Temperature Characteristics G3TC-ODC5A G3TC-ODC15A G3TC-ODC24A 2 3 1.5 2 1.6 1 G3TC-OAC5A G3TC-OAC15A G3TC-OAC24A G3TC-OAC5 G3TC-OAC15 G3TC-OAC24 4 Load current (A) 4 Load current (A) Load current (A) G3TC-ODC5 G3TC-ODC15 G3TC-ODC24 1 0.55 0.5 3 2 1.6 1 0.37 0 −30 −20 0 20 40 45 60 70 80 100 0 −30 −20 Ambient temperature (°C) 0 20 40 45 60 70 80 100 0 −30 −20 0 20 40 45 60 70 80 100 Ambient temperature (°C) Ambient temperature (°C) ■ Inrush Current Resitivity Non-repetitive (Keep inrush current to half the rated value if it occurs.) 15 28 14 26 13 24 22 20 18 16 14 12 10 8 6 12 11 10 9 8 7 6 5 4 3 4 2 2 1 0 0 20 30 50 70 100 200 300 500 Energized time (ms) 1,000 2,000 50 Inrush current (A. Peak) 30 G3TC-OAC5A G3TC-OAC15A G3TC-OAC24A G3TC-OAC5 G3TC-OAC15 G3TC-OAC24 G3TC-ODC5A G3TC-ODC15A G3TC-ODC24A Inrush current (A. Peak) Inrush current (A. Peak) G3TC-ODC5 G3TC-ODC15 G3TC-ODC24 40 30 20 10 0 0 0 30 50 100 300 500 Energized time (ms) 1,000 2,000 10 30 50 100 200 500 1,000 5,000 Energized time (ms) Solid State Relays for Industrial I/O G3TC 401 Dimensions G3TC-IAC5 G3TC-IAC5A G3TC-IAC15 G3TC-IAC15A G3TC-IAC24 G3TC-IAC24A 15.2 Note: All units are in millimeters unless otherwise indicated. 2.5 43.2 #4–40 Hold down screw 31.8 25.4 5 4 3 2 1 6.0 7.6 1.0 dia. 7.6 10.16 22.86 27.94 G3TC-IDC5 G3TC-IDC15 G3TC-IDC24 15.2 33.02 2.5 43.2 #4–40 Hold down screw 31.8 25.4 5 4 3 2 1 6.0 7.6 1.0 dia. 7.6 10.16 22.86 27.94 G3TC-OAC5 G3TC-OAC5A G3TC-OAC15 G3TC-OAC15A G3TC-OAC24 G3TC-OAC24A 15.2 33.02 (2.5) 43.2 #4–40 Hold down screw 31.8 25.4 4 3 2 1 6.0 7.6 10.16 22.86 27.94 402 Solid State Relays for Industrial I/O G3TC 1.0 dia. 7.6 15.2 G3TC-ODC5 G3TC-ODC5A G3TC-ODC15 G3TC-ODC15A G3TC-ODC24 G3TC-ODC24A 2.5 43.2 #4–40 Hold down screw 31.8 25.4 4 3 2 1 6.0 7.6 1.0 dia. 10.16 7.6 22.86 27.94 ■ Approvals UL Recognized (File No. E64562) / CSA Certified (File No. 35535) - - Ambient Temp. = 40°C Input Output Model Input voltage Model Load voltage Load current G3TC-IAC5, -IAC15, -IAC24 90-140 V AC/DC G3TC-IAC5, -IAC15, -IAC24 5/15/24 VDC 50 mA G3TC-IAC5A, -IAC15A, -IAC24A 180-280 V AC/DC G3TC-IAC5A, -IAC15A, -IAC24A 5/15/24 VDC 50 mA G3TC-IDC5, -IDC15, -IDC24 10-32 VDC, 12-32 VAC G3TC-IDC5, -IDC15, -IDC24 5/15/24 VDC 50 mA G3TC-ODC5, -ODC5A, -OAC5, -OAC5A 5 VDC G3TC-ODC5, -ODC15, -ODC24 5-60 VDC 3A G3TC-ODC15, -ODC15A, -OAC15, -OAC15A 15 VDC G3TC-ODC5A, -ODC15A, -ODC24A 5-200 VDC 1A G3TC-ODC24, -ODC24A, -OAC24, -OAC24A 24 VDC G3TC-OAC5, -OAC15, -OAC24 75-140 VAC 3A G3TC-OAC5A, -OAC15A, -OAC24A 75-280 VAC 3A Note: The rated values approved by each of the safety standards (e.g., UL, CSA and TUV) may be different from the performance characteristics individually defined in this catalog. Solid State Relays for Industrial I/O G3TC 403 Precautions !WARNING Do not touch the relay while power is supplied or immediately after G3TC is turned OFF. Doing so may result in burns. !WARNING Do not touch the load terminal of the G3TC immediately after the power is turned OFF, otherwise an electric shock may be received due to the residual charge of the built-in C/R circuit. 9. For a DC inductive load, a diode should be connected in parallel with the load to absorb the counter electromotive force of the load. 10.For an I/O mounting rack that is installed horizontally, use the G3TC with loads that are within the following conditions. G3TC-OAC5, -OAC5A, -OAC15, -OAC15A, -OAC24, -OAC24A Horizontal Mounting 4 !WARNING Ensure that a short-circuit current does not flow on the load side of the SSR, otherwise the G3TC may be damaged. Load current (A) !WARNING Be sure to turn OFF the power supply to the G3TC before wiring, otherwise an electric shock may result. 3 2.1 2 1 ■ General Precautions 0.64 1. Do not apply excessive voltage or current to the input or output circuit of the G3TC. Doing so may result in malfunction or burning. 2. Do not connect the input and output circuits incorrectly. Doing so may result in malfunction or burning. 3. Do not obstruct the flow of air around the G3TC. Abnormal heating of the G3TC may result in short-circuiting of output elements and burning. ■ Correct Use 0 −30 −20 0 20 40 45 60 70 80 100 Ambient temperature (°C) G3TC-ODC5, -ODC15, -ODC24 Horizontal Mounting 4 Load current (A) At OMRON, we are constantly working to improve the quality and reliability of our products. SSRs, however, use semiconductors, which are prone to malfunction. Be sure to use SSRs within their rated value. Use the SSR only in systems that are designed with redundancies, flame protection, counter measures to prevent operation errors, and other countermeasures to prevent accidents involving human life or fires. 3 2.7 2 1 0.64 Before Actual Operation 1. In actual operation, the G3TC may cause accidents that were unforeseeable at the theoretical stage. Therefore, it is necessary to test the G3TC under a variety of conditions that are possible. As for the characteristics of the G3TC, it is necessary to consider the differences between G3TC models. 2. The ratings in this datasheet are for testing in a temperature range of 15 to 30°C, a relative humidity range of 25% to 85%, and an atmospheric pressure range of 88 to 106kPa. When testing operation, it is necessary to confirm correct operation not only with the actual load that will be used, but also at the same ambient conditions as for actual operation. 3. The input circuitry does not incorporate a circuit protecting the SSR from being damaged due to a reversed connection. Make sure that the polarity is correct when connecting the input lines. 4. Only use the G3TC with loads that are within the rated values. Using the G3TC with loads outside the rated values may result in malfunction, damage, or burning. 5. Use a power supply within the rated frequency range. Using a power supply outside the rated frequency range may result in malfunction, damage, or burning. 6. No over-voltage absorption element is built in. Therefore, if the G3TC is connected to an inductive load, be sure to connect an over-voltage absorption element. 7. As protection against accidents due to short-circuiting, be sure to install protective devices, such as fuses on the power supply side. 8. Keep wiring separate from high-voltage power lines and use wires of an appropriate length, otherwise malfunction and damage may result due to induction. 404 Solid State Relays for Industrial I/O G3TC 0 −30 −20 0 20 40 45 60 70 80 Ambient temperature (°C) 100 ■ Operating and Storage Environments Operating Ambient Temperature The rated value for the ambient operating temperature of the G3TC is for when there is no built-up heat. For this, reason, under conditions where heat dissipation is not good due to poor ventilation, and where heat may build up easily, the actual temperature of the G3TC may exceed the rated value resulting in malfunction or burning. When using the G3TC, design the system to allow heat dissipation sufficient to stay below the Load Current vs. Ambient Temperature characteristic curve. Note also that the ambient temperature of the G3TC may increase as a result of environmental conditions (e.g., climate, air-conditioning) and operating conditions (e.g., mounting in an airtight panel). Operating and Storage Locations Do not use or store the G3TC in the following locations. Doing so may result in damage, malfunction, or deterioration of performance characteristics. 1. Do not use or store in locations subject to direct sunlight. 2. Do not use in locations subject to ambient temperatures outside the range -30° to 80°C. 3. Do not use in locations subject to relative humidity outside the range 45% to 85% or locations subject to condensation as the result of severe change in temperature. 4. Do not store in locations subject to ambient temperatures outside the range -30° to 100°C. 5. Do not use or store in locations subject to corrosive or flammable gases. 6. Do not use or store in locations subject to dust (especially iron dust) or salts. 7. Do not use or store in locations subject to shock or vibration. 8. Do not use or store in locations subject to exposure to water, oil, or chemicals. Transportation When transporting the G3TC, observe the following points. Not doing so may result in damage, malfunction, or deterioration of performance characteristics. 1. Do not drop the G3TC or subject it to severe vibrations or shock. 2. Do not transport the product if it is wet. Vibration and Shock Do not subject the SSR to excessive vibration or shock. Otherwise the SSR may malfunction and internal components may be damaged. Solid State Relays for Industrial I/O G3TC 405 MEMO 406 Solid State Relays for Industrial I/O G3TC Omron Electronic Components, LLC Terms and Conditions of Sales I. GENERAL 1. Definitions: The words used herein are defined as follows. (a) Terms: These terms and conditions (b) Seller: Omron Electronic Components LLC and its subsidiaries (c) Buyer: The buyer of Products, including any end user in section III through VI (d) Products: Products and/or services of Seller (e) Including: Including without limitation 2. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments, invoices, purchase orders and other documents, whether electronic or in writing, relating to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's purchase order or other documents which are inconsistent with, or in addition to, these Terms. 3. Distributor: Any distributor shall inform its customer of the contents after and including section III of these Terms. II. SALES 1. Prices; Payment: All prices stated are current, subject to change without notice by Seller. Buyer agrees to pay the price in effect at the time the purchase order is accepted by Seller. Payments for Products received are due net 30 days unless otherwise stated in the invoice. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. 2. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past due amounts owing to Seller. 3. Interest: Seller, at its option, may charge Buyer 1.5% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 4. Orders: Seller will accept no order less than 200 U.S. dollars net billing. 5. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer shall make remittance to Seller at the then current exchange rate most favorable to Seller; provided that if remittance is not made when due, Buyer will convert the amount to U.S. dollars at the then current exchange rate most favorable to Seller available during the period between the due date and the date remittance is actually made. 6. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining any government approvals regarding the importation or sale of the Products. 7. Taxes: All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Seller or required to be collected directly or indirectly by Seller for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Seller. 8. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller, Seller reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Seller may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Seller fully against all costs or expenses arising in connection therewith. 10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller: (a) All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Seller), at which point title to and all risk of loss of the Products shall pass from Seller to Buyer, provided that Seller shall retain a security interest in the Products until the full purchase price is paid by Buyer; (b) Delivery and shipping dates are estimates only; and (c) Seller will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims: Any claim by Buyer against Seller for shortage or damage to the Products occurring before delivery to the carrier or any claim related to pricing or other charges must be presented in detail in writing to Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability: IT IS THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER’S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E) SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT. Buyer acknowledges that it alone has determined that the Products will meet their requirements of the intended use in all cases. Buyer must know and observe all prohibitions of use applicable to the Product/s. 2. Use with Attention: The followings are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible use of any Product, nor to imply that any use listed may be suitable for any Product: (a) Outdoor use, use involving potential chemical contamination or electrical interference. (b) Use in consumer Products or any use in significant quantities. (c) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (d) Systems, machines, and equipment that could present a risk to life or property. 3. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 4. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY SELLER. 5. Programmable Products: Seller shall not be responsible for the Buyer's programming of a programmable Product. IV. WARRANTY AND LIMITATION 1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Seller (or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES, NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. 2. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an amount equal to the purchase price of the Product; provided that there shall be no liability for Seller or its affiliates unless Seller's analysis confirms that the Products were correctly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Seller before shipment. 3. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF THE PRODUCT ON WHICH LIABILITY IS ASSERTED. 4. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. V. INFORMATION; ETC. 1. Intellectual Property: The intellectual property embodied in the Products is the exclusive property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way without the written permission of Seller. Buyer (at its own expense) shall indemnify and hold harmless Seller and defend or settle any action brought against Seller to the extent that it is based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. 2. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Seller. All information and materials supplied by Seller to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. 3. Performance Data: Performance data is provided as a guide in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements. 4. Change In Specifications: Product specifications and descriptions may be changed at any time based on improvements or other reasons. It is Seller’s practice to change part numbers when published ratings or features are changed, or when significant engineering changes are made. However, some specifications of the Product may be changed without any notice. 5. Errors And Omissions: The information on Seller’s website or in other documentation has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 6. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses regarding (a) export of the Products or information provided by Seller; (b) sale of Products to forbidden or other proscribed persons or organizations; (c) disclosure to noncitizens of regulated technology or information. VI. MISCELLANEOUS 1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing between Buyer and Seller shall operate as a waiver of rights by Seller. 2. Assignment: Buyer may not assign its rights hereunder without Seller's written consent. 3. Law: These Terms are governed by Illinois law (without regard to conflict of laws). Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any dispute hereunder. 4. Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. Solid State Relays for Industrial I/O G3TC Certain Precautions on Specifications and Use 1. Suitability for Use. Seller shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in Buyer's application or use of the Product. At Buyer's request, Seller will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases but the following is a nonexhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iii) Use in consumer products or any use in significant quantities. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 2. Programmable Products. Seller shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 3. Performance Data. Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to Seller's Warranty and Limitations of Liability. 4. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Seller representative at any time to confirm actual specifications of purchased Product. 5. Errors and Omissions. The information in this publication has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors, or omissions. 6. RoHS Compliance. Where indicated, our products currently comply, to the best of our knowledge as of the date of this publication, with the requirements of the European Union's Directive on the Restriction of certain Hazardous Substances ("RoHS"), although the requirements of RoHS do not take effect until July 2006. These requirements may be subject to change. Please consult our website for current information. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC Global - http://www.omron.com USA - http://www.components.omron.com 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. X301-E-1 06/09 Specifications subject to change without notice Solid State Relays for Industrial I/O G3TC Printed in USA