Home > Product Details LCA50S Features Small and compact PCB construction UL recognized, CSA certified Built-in Inrush Current Protection RoHS Compliant Safety Agency Approvals Complies with DEN-AN UL1950, CSA C22.2 No.234 EMI Compliance FCC-B VCCI-B 2 year warranty(refer to Instruction Manual) Input Voltage [V] Output Wattage [W] DC Output [V/A] LCA50S-3 DC 110 170 AC 85 - 132 30 3V 10A LCA50S-5 DC 110 170 AC 85 - 132 50 5V 10A LCA50S-12 DC 110 170 AC 85 - 132 51.6 12V 4.3A LCA50S-15 DC 110 170 AC 85 - 132 52.5 15V 3.5A LCA50S-24 DC 110 170 AC 85 - 132 60 24V 2.5A LCA50S-24-H DC 110 170 AC 85 - 132 60 (peak 72) 24V 2.5A (peak 3A) LCA50S-36 DC 110 170 AC 85 - 132 61.2 36V 1.7A LCA50S-48 DC 110 170 AC 85 - 132 62.4 48V 1.3A Model Ordering information Rugged PCB type LCA50S LC 1 A 2 50 3 S 4 Recommended Noise Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series -5 5 -O 6 1Series name 2100/120V input 3Output wattage 4Single output 5Output voltage 6Optional C :with Coating G :Low leakage current Y :with Potentiometer *The Noise Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT LCA50S-3 30 3V 10A LCA50S-5 50 5V 10A LCA50S-12 51.6 12V 4.3A LCA50S-15 52.5 15V 3.5A LCA50S-24 60 24V 2.5A LCA50S-24-H LCA50S-36 60 61.2 24V 2.5A 36V 1.7A LCA50S-48 62.4 48V 1.3A SPECIFICATIONS LCA INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V FREQUENCY[Hz] EFFICIENCY[%] INRUSH CURRENT[A] ACIN 100V LEAKAGE CURRENT[mA] VOLTAGE[V] *3 CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD LCA50S-3 LCA50S-5 LCA50S-12 LCA50S-15 LCA50S-24 LCA50S-24-H LCA50S-36 LCA50S-48 AC85 - 132 1f or DC110 - 170 1.3typ (Io=100%) 47 - 440 or DC 71typ 78typ 80typ 81typ 82typ 82typ 82typ 82typ 30typ (Io=100%) (At cold start) 0.5max (60Hz, According to UL, CSA and DEN-AN) 3 5 12 15 24 24 36 48 10 10 4.3 3.5 2.5 2.5 (Peak 3) 1.7 1.3 20max 20max 48max 60max 96max 96max 144max 192max 40max 40max 100max 120max 150max 150max 240max 300max 80max 80max 120max 120max 120max 120max 150max 150max 140max 140max 160max 160max 160max 160max 200max 200max 120max 120max 150max 150max 150max 150max 250max 350max 160max 160max 180max 180max 180max 180max 300max 400max 50max 50max 120max 150max 240max 240max 360max 480max 60max 60max 150max 180max 290max 290max 450max 600max 20max 20max 48max 60max 96max 96max 144max 192max 200max (ACIN 85V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as optional: 5, 12, 15, 24, 36, 48V t10%) 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 23.0 - 25.0 34.5 - 37.5 46.0 - 50.0 xx Works over 105% of rating (works over 105% of peak current at option -H) and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating Not provided Not provided Not provided AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, CSA C22.2 No.234 Complies with DEN-AN Complies with FCC-B, VCCI-B 50X25X195mm (WXHXD) / 200g max Convection *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output. *3 Peak load for 10 sec. or less is acceptable(The average current has to be less than the rated current). E-66 LCA50S External view LCA Performance data ¡STATIC CHARACTERISTICS (LCA50S-5) ¡RISE TIME & FALL TIME (LCA50S-5) ¡OVERCURRENT CHARACTERISTICS (LCA50S-5) ¡DERATING CURVE E-67