MA600RWI Series Wide 2:1 Input, 6W, High 3 kVDC Isolation DC/DC Converters Electrical Specifications Key Features: Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. • 6W Output Power Input Parameter • 2:1 Input Voltage Range Input Start Voltage • 3,000 VDC Isolation • 24 Standard Models • Single & Dual Outputs • Compact DIP Case • -40°C to +85°C Operation • Industry Standard Pin-Out Under Voltage Shutdown Input Filter Typ. 8.0 16.0 34.0 Conditions Typ. ±1.0 ±1.0 ±0.1 ±0.6 Max. 9.0 18.0 36.0 8.5 16.0 35.0 Units Max. ±2.0 ±2.0 ±0.5 ±1.2 70 100 600 Units % % % % VDC VDC Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Min. Dual Output, Balanced Loads VIN = Min to Max IOUT = 0% to 100% See Note 1 Over Line, Load & Temp. Ripple & Noise (20 MHz) 1.5 kV Isolation Models Available Conditions Min. 12 VDC Input 7.0 24 VDC Input 14.0 48 VDC Input 32.0 12 VDC Input 24 VDC Input 48 VDC Input (Pi) Filter Transient Recovery Time, See Note 2 Transient Response Deviation Temperature Coefficient Output Overload Protection Output Short Circuit 300 25% Load Step Change ±3.0 ±0.01 Foldback 110 145 Continuous (Autorecovery) ±0.02 Conditions Max. mV P - P µSec % %/°C % General 4:1 Input Range Models Available Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency EMI Characteristics Parameter Radiated Emissions Conducted Emissions ESD RS EFT Surge CS 60 Seconds 500 VDC 100 kHz/1.0V Standard See Note 3 See Note 3 EN 55022 EN 55022 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 Min. 3,000 1,000 Typ. 1,000 330 Units VDC M pF kHz Level Class A Class A Criteria A; ±8 kV Air ±6 kV Contact Criteria A; 10V/m Criteria A; ±2 kV Criteria A; ±1 kV Criteria A; 10V/m Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Conditions Ambient Case Min. -40 Typ. +25 -50 Free Air Convection RH, Non-condensing Max. +85 +100 +125 Units °C °C °C 95 % 1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm) Non-Conductive Black Plastic (UL94-V0) 0.45 Oz (12.8g) Reliability Specifications T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter MTBF Conditions MIL HDBK 217F, 25°C, Gnd Benign Min. 1.0 Typ. Max. Units MHours Conditions 12 VDC Input 24 VDC Input 48 VDC Input 1.5 mm From Case for 10 Sec Min. -0.7 -0.7 -0.7 Typ. Max. 25.0 50.0 100.0 260 Units Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC °C www.micropowerdirect.com Model Selection Guide Input Model Number MA612S-03RWI MA612S-05RWI MA612S-12RWI MA612S-15RWI MA612S-24RWI MA612D-05RWI MA612D-12RWI MA612D-15RWI MA624S-05RWI MA624S-05RWI MA624S-12RWI MA624S-15RWI MA624S-24RWI MA624D-05RWI MA624D-12RWI MA624D-15RWI MA648S-03RWI MA648S-05RWI MA648S-12RWI MA648S-15RWI MA648S-24RWI MA648D-05RWI MA648D-12RWI MA648D-15RWI Voltage (VDC) Nominal Range 12 12 12 12 12 12 12 12 24 24 24 24 24 24 24 24 48 48 48 48 48 48 48 48 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 36.0 - 72.0 36.0 - 72.0 36.0 - 72.0 36.0 - 72.0 36.0 - 72.0 36.0 - 72.0 36.0 - 72.0 36.0 - 72.0 Output Current (mA) Voltage Current (mA, Max) Full-Load No-Load (VDC) 440 641 609 609 595 534 609 609 214 313 298 298 298 260 298 298 107 156 149 149 149 130 149 149 40 40 40 40 40 40 40 40 20 20 20 20 20 20 20 20 10 10 10 10 10 10 10 10 3.3 5.0 12.0 15.0 24.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 24.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 24.0 ±5.0 ±12.0 ±15.0 Current (mA, Min) 1,200.0 1,200.0 500.0 400.0 250.0 ±500.0 ±250.0 ±200.0 1,200.0 1,200.0 500.0 400.0 250.0 ±500.0 ±250.0 ±200.0 1,200.0 1,200.0 500.0 400.0 250.0 ±500.0 ±250.0 ±200.0 0.0 0.0 0.0 0.0 0.0 ±0.0 ±0.0 ±0.0 0.0 0.0 0.0 0.0 0.0 ±0.0 ±0.0 ±0.0 0.0 0.0 0.0 0.0 0.0 ±0.0 ±0.0 ±0.0 Notes: 1. When measuring output ripple, it is recommended that an external 3.3 µF ceramic capacitor be placed from the +VOUT pin to the -VOUT pin for single output units and from each output to common for dual output units. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Operation at no-load will not damage these units. 4. An external 220 µF/100V capacitor connected across the input pins is required to meet EN61000-4-4 and EN61000-4-5. 5. Dual output units may be connected to provide a 10, 24 or 30 VDC output. To do this, connect the load across the positive (+VOUT) and negative (-VOUT) outputs and float the output common. 6. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor be mounted close to the converter. For 12V input units a 3.3 µF is recommended; and for 24V & 48V units a 2.2 µF. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Efficiency (%, Typ) Fuse Reflected Capacitive Ripple Rating Load Current Slow-Blow (µF, Max) (mA Typ) 75 78 82 82 84 78 82 82 77 80 84 84 84 80 84 84 77 80 84 84 84 80 84 84 (mA) 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 470 470 100 100 47 ±100 ±100 ±100 470 470 100 100 47 ±100 ±100 ±100 470 470 100 100 47 ±100 ±100 ±100 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 700 700 700 700 700 700 700 700 350 350 350 350 350 350 350 350 For 1.5 kV Isolation, See MA600x-xxRW Series Datasheet For 4:1 Inputs, See MA600x-xxRU Series Datasheet Mechanical Dimensions Derating Curve Pin Connections Pin Single Dual 2, 3 9 11 14 16 22, 23 -VIN No Pin NC +V VOUT -V VOUT +VIN -VIN Common -V VOUT +V VOUT Common +VIN NC: No Connection Mechanical Notes: MicroPower Direct • All dimensions are typical in inches (mm) • Tolerance x.x = ±0.02 (±0.50) • Tolerance x.xx = ±0.01 (±0.25) We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]