Shunye M7G Surface mount glass general rectifier Datasheet

M1G THRU M7G
SURFACE MOUNT GLASS GENERAL RECTIFIER
Reverse Voltage – 50 to 1000 V
Forward Current – 1 A
Features
• For surface mounted applications
• Low profile package
• Built-in strain relief
• Easy pick and place
• Plastic package has Underwriters Laboratory
Flammability Classification 94V-0
• Glass passivated chip junction
Mechanical Data
• Case: SMA (DO-214AC), molded plastic.
• Terminals: Solder plated, solderable per MIL-STD-750
Method 2026
• Polarity: Indicated by cathode band.
Absolute Maximum Ratings and Characteristics
Ratings at 25OC ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Symbols M1G M2G M3G M4G M5G M6G M7G
Units
Paramter
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
V
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
V
Maximum DC Blocking Voltage
VDC
50
100
200
400
600
800
1000
V
Maximum Average Forward Rectified Current
at TL = 100 OC
I(AV)
1
A
Peak Forward Surge Current 8.3ms Single Half
Sine-wave Superimposed on Rated Load (JEDEC
method)
IFSM
30
A
Maximum Instantaneous Forward Voltage at 1 A
VF
1.1
V
Maximum DC Reverse Current
at Rated DC Blocking Voltage
IR
5
50
µA
CJ
12
RθJL
30
TJ ,TS
- 55 to + 150
at TA = 25 OC
at TA = 125 OC
Typical Junction Capacitance 1)
Typical Thermal Resistance
2)
Operating and Storage Temperature Range
1)
2)
Measured at 1 MHz and applied VR = 4 V.
8 mm2 (0.013 mm thick) land areas.
www.shunyegroup.com.cn
pF
C/W
O
C
O
M1G THRU M7G
2.0
1.0
25 50 75 100 125 150 175
LEAD TEMPERATURE .o C
PEAK FORWARD SURGE CURRENT,
AMPERES
AVERAGE FORWARD CURRENT,
AMPERES
30
SINGLE PHASE
HALF WAVE 60Hz
RESISTIVE OR
INDUCTIVE LOAD
P.C.B MOUNTED
ON 0.315x0.315"(8.0x8.0mm)
COPPER PAD AREAS
25
15
10
5
1
INSTANTANEOUS FORWARD CURRENT,
MICROAMPERES
INSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
10
Tj =125o C
Tj =75o C
Tj =25o C
0.01
0.001
0
20
40
60
10
20
50
100
Fig. 2-MAXIMUM NON-REPETITIVE PEAK FORWARD
SURGE CURRENT
100
0.1
5
2
NUMBER OF CYCLES AT 60 Hz
Fig. 1-FORWARD CURRENT
DERATING CURVE
1
8.3ms Single Half Sine Wave
(JEDEC Method)
20
80 100 120 140
PERCENT OF PEAK REVERSE VOLTAGE, %
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
INSTANTANEOUS FORWARD
VOLTAGE , VOLTS
Fig. 4-TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
Fig. 3-TYPICAL REVERSE
CHARACTERISTICS
500
200
100
50
Units Mounted On
20in2 (5.4mm 2 )+0.5mil
inches(0.013mm)
Thick Copper Land Areas
100
CAPACITANCE. pF
THERMAL IMPEDANCE (oC/W)
1000
20
10
5
2
1
0.01
0.1
1
10
Tj =25 oC
f=1.0MHz
Vsig=50mVp-p
50
20
10
5
2
1
0
1.0
10
100
100
REVERSE VOLTAGE VOLTS
REVERSE VOLTAGE VOLTS
Fig. 5-TRANSIENT THERMAL IMPEDANCE
Fig. 6-TYPICAL JUNCTION CAPACITANCE
www.shunyegroup.com.cn
1000