DB Lectro N68FCZ8CDC24VB Employment of suitable plastic materials to be applied to high temperature and various chemical solution Datasheet

Présente / Presents:
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
N68F
NHG RELAYS
N68F
Operation condition
R
E158859
Patent NO.:03209705.0
C
28.5 10.1 12.3
US
Features
Slim type and small occupying area can offer high density P.C.B. technique.
Employment of suitable plastic materials to be applied to high temperature and various chemical solution.
Dielectric strength 5000V.
Creepage distance >8mm.
Insulation Resistance
1000M
Dielectric Strength
Between contacts
Between contact and coil
min (at 500VDC)
50Hz 1000V
50Hz 5000V
Item 7 of IEC255-5
Item 6 of IEC255-5
Item 6 of IEC255-5
Shock resistance
Functional 100m/s2
Survival: 1000m/s2
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
10~500Hz double amplitude 1.5mm 200m/s2
10N
235
2
3 0.5s
-40~70
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
Relative Humidity
Mass
85% (at 40 )
8.2g
IEC68-2-3Test Ca
11ms
6ms
IEC68-2-27 Test Ea
Qualification inspection:
Perform the qualification test as specified in the table
Ordering Information
Safety approvals
N68F C S 8 C DC12V F
6
Safety approval
Load
7
5 Contact material NIL:AgNi (Gold clad) W:AgNi
CD:AgCdO (Gold clad) C:AgCdO
1 Part number N68F
2 Contact arrangement A:1A;C:1C
3 Enclosure S:Sealed type Z:Dust cover
4 Contact current 8A
6 Coil rated voltage(V) DC:5,6,12,18,24,48,60
7 Resist heat class B:130
F:155
Dimensions
Contact Data
1A (SPSTNO
Contact Material
Ag CdO Ag SnO2
Contact Rating
Resistive
8A/250VAC
30VDC
Max. Switching Power
Resistive
300W
2500VA
Max. Switching Voltage
125VDC 380VAC
Contact Resistance or Voltage drop
Electrical
Mechanical
100m
5- 1.3
0.051
Max. Switching Current:10A
28.5max.
1.122max.
2.5
0.098
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
Rated
Coil
resistance
10%
Max
Pickup
voltage
VDC (max)
(75%of rated
voltage )
Release
voltage
VDC (min)
(10% of
rated
voltage)
Coil power
consumption
W
Operate
Time
ms
2-0.5X0.5
0.020 0.020
1A
Release
Time
ms
5
6
12
18
24
11.8
14.1
28.2
42.3
56.4
113
164
620
1295
2350
3.75
4.5
9.0
13.5
18.0
0.5
0.6
1.2
1.8
2.4
0.22
7
3
048-250
003-250
48
60
112.8
141.0
9600
12500
36.0
45.0
4.8
6.0
0.25
7
3
18.9
5.08
0.744
0.200
Mounting (Bottom view)
1A
005-220
006-220
012-220
018-220
024-220
3.2
0.126
4- 1.3
0.051
Dimensions
Coil voltage
VDC
18.9
0.744
7.62
0.300
6-0.4X0.8
0.016 0.031
3.2
0.126
1C
Item 3.12 of IEC255-7
105
107
Coil Parameter
Dash
numbers
10.1max.
0.398max.
7.62
Operational
life
mm /inch
1C (SPDT(B-M))
3.6 0.3
0.142 0.012
Contact Arrangement
UL & CUR
8A/250VAC,30VDC
7.62
5
0.300
4
0.300
3
0.3
0.012
2
12.3max.
0.484max.
1
of IEC255-19-1 and minimum sample size 24.
1C
Wiring diagram
(Bottom view)
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
Reference Data
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
3.Unless otherwise stated, the rated coil voltage specified in coil parameter table shall be used for all tests and its
application to the relay.
Ningbo Forward Relay Corporation LTD.
68
N68F
N68F
Operation condition
R
E158859
Patent NO.:03209705.0
C
28.5 10.1 12.3
US
Features
Slim type and small occupying area can offer high density P.C.B. technique.
Employment of suitable plastic materials to be applied to high temperature and various chemical solution.
Dielectric strength 5000V.
Creepage distance >8mm.
Insulation Resistance
1000M
Dielectric Strength
Between contacts
Between contact and coil
min (at 500VDC)
50Hz 1000V
50Hz 5000V
Item 7 of IEC255-5
Item 6 of IEC255-5
Item 6 of IEC255-5
Shock resistance
Functional 100m/s2
Survival: 1000m/s2
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
10~500Hz double amplitude 1.5mm 200m/s2
10N
235
2
3 0.5s
-40~70
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
Relative Humidity
Mass
85% (at 40 )
8.2g
IEC68-2-3Test Ca
11ms
6ms
IEC68-2-27 Test Ea
Qualification inspection:
Perform the qualification test as specified in the table
Ordering Information
Safety approvals
N68F C S 8 C DC12V F
6
Safety approval
Load
7
5 Contact material NIL:AgNi (Gold clad) W:AgNi
CD:AgCdO (Gold clad) C:AgCdO
1 Part number N68F
2 Contact arrangement A:1A;C:1C
3 Enclosure S:Sealed type Z:Dust cover
4 Contact current 8A
6 Coil rated voltage(V) DC:5,6,12,18,24,48,60
7 Resist heat class B:130
F:155
Dimensions
Contact Data
1A (SPSTNO
Contact Material
Ag CdO Ag SnO2
Contact Rating
Resistive
8A/250VAC
30VDC
Max. Switching Power
Resistive
300W
2500VA
Max. Switching Voltage
125VDC 380VAC
Contact Resistance or Voltage drop
Electrical
Mechanical
100m
5- 1.3
0.051
Max. Switching Current:10A
28.5max.
1.122max.
2.5
0.098
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
Rated
Coil
resistance
10%
Max
Pickup
voltage
VDC (max)
(75%of rated
voltage )
Release
voltage
VDC (min)
(10% of
rated
voltage)
Coil power
consumption
W
Operate
Time
ms
2-0.5X0.5
0.020 0.020
1A
Release
Time
ms
5
6
12
18
24
11.8
14.1
28.2
42.3
56.4
113
164
620
1295
2350
3.75
4.5
9.0
13.5
18.0
0.5
0.6
1.2
1.8
2.4
0.22
7
3
048-250
003-250
48
60
112.8
141.0
9600
12500
36.0
45.0
4.8
6.0
0.25
7
3
18.9
5.08
0.744
0.200
Mounting (Bottom view)
1A
005-220
006-220
012-220
018-220
024-220
3.2
0.126
4- 1.3
0.051
Dimensions
Coil voltage
VDC
18.9
0.744
7.62
0.300
6-0.4X0.8
0.016 0.031
3.2
0.126
1C
Item 3.12 of IEC255-7
105
107
Coil Parameter
Dash
numbers
10.1max.
0.398max.
7.62
Operational
life
mm /inch
1C (SPDT(B-M))
3.6 0.3
0.142 0.012
Contact Arrangement
UL & CUR
8A/250VAC,30VDC
7.62
5
0.300
4
0.300
3
0.3
0.012
2
12.3max.
0.484max.
1
of IEC255-19-1 and minimum sample size 24.
1C
Wiring diagram
(Bottom view)
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
Reference Data
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
3.Unless otherwise stated, the rated coil voltage specified in coil parameter table shall be used for all tests and its
application to the relay.