160W AC-DC High Reliability Medical Adaptor GSM160B series Features ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧℃ ‧Ⅱ ‧ ‧ ‧ ‧ ‧ Description { File Name:GSM160B-SPEC 2015-07-23 GSM160B 160W AC-DC High Reliability Medical Adaptor series SPECIFICATION ORDER NO. SAFETY MODEL NO. DC VOLTAGE OUTPUT GSM160B20-R7B GSM160B24-R7B GSM160B48-R7B GSM160B12 GSM160B15 GSM160B20 GSM160B24 GSM160B48 15V 20V 24V 48V RATED CURRENT 11.5A 9.6A 8A 6.67A 3.34A CURRENT RANGE 0 ~ 11.5A 0 ~ 9.6A 0 ~ 8A 0 ~ 6.67A 0 ~ 3.34A RATED POWER (max.) 138W 144W 160W 160W 160W RIPPLE & NOISE (max.) Note.3 80mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p VOLTAGE TOLERANCE Note.4 ±5.0% LINE REGULATION Note.5 ±1.0% ±5.0% ±1.0% ±5.0% ±4.0% ±1.0% ±4.0% ±3.0% ±1.0% ±3.0% ±3% ±1.0% ±3% ±5.0% SETUP, RISE TIME Note.6 2000ms, 50ms / 230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE 20ms / 230VAC 20ms / 115VAC at full load Note.7 80 ~ 264VAC 113 ~ 370VDC 2500ms, 50ms / 115VAC at full load FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 12V/15V:PF>0.93 / 230VAC 20V,24V,48V:PF>0.94 / 230VAC 90% 91% 92.5% EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT(max.) OVERLOAD PROTECTION GSM160B15-R7B Note.2 12V LOAD REGULATION INPUT GSM160B12-R7B OVER VOLTAGE 1.85A / 115VAC PF>0.98 / 115VAC at full load 93% 94% 1A / 230VAC 120A / 230VAC Touch current < 100 A/264VAC 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, re-power on to recover WORKING TEMP. WORKING HUMIDITY -30 ~ +70℃ (Refer to "Derating Curve") 20% ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH TEMP. COEFFICIENT ±0.03% / ℃ (0 ~ 50℃) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ANSI/AAMI ES60601-1 / ES60601-1-11, TUV EN60601-1 / EN60601-1-11 approved SAFETY STANDARDS Primary-Secondary: 2xMOPP SAFETY & ISOLATION LEVEL WITHSTAND VOLTAGE I/P-O/P: 4KVAC EMC (Note. 8) ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH OTHERS CONNECTOR NOTE EMC EMISSION EMC IMMUNITY Compliance to EN55011(CISPR11) class B, EN61000-3-2,3, FCC PART 15 class B MTBF DIMENSION 239.1K hrs min. MIL-HDBK-217F(25℃) 175*72*35mm (L*W*H) 0.66Kg; 20pcs/14.2Kg/1.06CUFT Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3 medical level, criteria A PACKING PLUG See page 3 ; Other type available by customer requested CABLE See page 3 ; Other type available by customer requested ℃ For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) File Name:GSM160B-SPEC 2015-07-23 GSM160B 160W AC-DC High Reliability Medical Adaptor Derating Curve series Static Characteristics 100 100 90 80 LOAD (%) LOAD (%) 80 60 50 40 70 60 50 20 -30 40 0 10 20 30 40 50 60 70 (HORIZONTAL) 80 90 AMBIENT TEMPERATURE (℃) 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Case No. GS160A Unit:mm Mechanical Specification 175 35 Ul2464 16AWGx4C 1000±50mm for 12V UL2464 18AWGx4C 1200±50mm for 15V ~ 48V POWER LED 30±3mm 72 23 14 Plug Assignment Output plug (Power DIN 4 pin with lock type) : KYCON KPPX-4P equivalent Mating plug (customer side , not provide with power supply) : KYCON KPJX-CM-4S equivalent R7B PIN NO. OUTPUT 2 1 3 4 1,4 +V 2,3 -V Installation Manual Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html File Name:GSM160B-SPEC 2015-07-23