Click on Series name for product info on aimtec.com Series AM2GW-Z 2 Watt | DC-DC Converter FEATURES: • • • • Models Single output Model Input Voltage (V) AM2GW-2403SZ AM2GW-2405SZ AM2GW-2412SZ AM2GW-2415SZ AM2GW-4803SZ AM2GW-4805SZ AM2GW-4812SZ AM2GW-4815SZ 9-36 9-36 9-36 9-36 18-75 18-75 18-75 18-75 Models Dual output Model Input Voltage (V) AM2GW-2405DZ AM2GW-2412DZ AM2GW-2415DZ AM2GW-4805DZ AM2GW-4812DZ AM2GW-4815DZ 9-36 9-36 9-36 18-75 18-75 18-75 Input Specifications Parameters Voltage range Filter Start up time Absolute Maximum Rating Peak Input Voltage time On/Off Control Input reflected ripple current Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance www.aimtec.com F 051e R11.F SIP9 Package Low Ripple and Noise Continuous Short Circuit Protection -40ºC to +85ºC Operating Temperature Range • • • • Ultra-Wide Input Range 4:1 1500VDC I/O Isolation Efficiency up to 85% Remote ON / OFF Control Output Voltage (V) Output Current Max (mA) Maximum Capacitive Load (µF) Input Current Full Load | No Load (mA) Efficiency (%) Output Voltage (V) Output Current Max (mA) Maximum Capacitive Load (µF) Input Current Full Load | No Load (mA) Efficiency (%) 3.3 5 12 15 3.3 5 12 15 ±5 ±12 ±15 ±5 ±12 ±15 Nominal 24 48 500 400 165 135 500 400 165 135 ±200 ±85 ±65 ±200 ±85 ±65 2200 1000 165 100 2200 1000 165 100 Typical 9-36 18-75 Capacitor 10 ±470 ±100 ±47 ±470 ±100 ±47 92 103 100 98 46 53 50 50 103 101 102 53 52 50 Maximum 10 10 10 10 5 5 5 5 10 10 15 5 5 5 75 82 85 84 75 80 84 83 82 84 82 80 82 81 Units VDC ms 50 VDC 100 100 ms ON: 0 to 0.6VDC (or open) ; OFF:2.7 to 15.0VDC ,OFF: idle current: 5mA, max 20 mA p-p 24Vin 48Vin Conditions 60 sec Typical >1000 500 Tel: +1 514 620 2722 1 of 5 Rated 1500 Units VDC MOhm pF Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2GW-Z 2 Watt | DC-DC Converter Output Specifications Parameters Voltage accuracy Cross Regulation (Dual Output Models) Short Circuit protection Short circuit restart Transient Response Deviation Transient Recovery Time Line voltage regulation Load voltage regulation Ripple & Noise General Specifications Parameters Conditions Typical 25% load on output - 100% load 2nd output Hiccup Auto-Recovery LL~HL From 10% to 100% load From 0% to 100% load 12Vout and 15Vout From 0% to 100% load 3.3Vout and 5Vout 20MHz Bandwidth Conditions ±1 ±5 Maximum Continuous ±3 300 ±0.5 ±0.5 ±0.5 ±1 50 Typical Units % % % µs % % mV p-p Maximum Units Switching frequency 100% load 250 KHz o Operating temperature -40 to +85 C o Storage temperature -40 to +125 C Temperature coefficient ±0.02 %/oC o Maximum case temperature 100 C %/°C Derating Above 75°C 3.5 Cooling Free Air Convection Humidity 95 % RH Case material Non conductive black plastic Potting Material Epoxy (UL94V-0 rated) Weight 6.5 g Dimensions (L x W x H) 1.02 x 0.36 x 0.49 inches 26.00 x.9.30 x 12.44 mm MTBF >1,212,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC) o Max Soldering Temperature 1.5mm from case 10 second 260 C NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Agency Approval CE EN55022 Class A, IEC61000-4-2, Perf. Criteria B IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria B (external 220uF/100V cap required) IEC61000-4-5, Perf. Criteria B (external 220uF/100V cap required) IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A NOTE: designed to meet IEC 60950-1:2001 Standards Pin Out Specifications Pin 1 2 3 6 7 8 9 Single - V Input + V Input On/Off Control + V Output NC NC - V Output www.aimtec.com F 051e R11.F Dual - V Input + V Input On/Off Control + V Output Common NC -V Output Tel: +1 514 620 2722 2 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2GW-Z 2 Watt | DC-DC Converter Dimensions All dimensions are in millimeters (inches) Pin diameter: 1.0 ±0.05 ( 0.04 ±0.002 ) Pin pitch tolerance: ±0.35 ( ±0.014 ) Case Tolerance: ±0.5 ( ±0.02 ) Derating Free Air Convection 75 º C Output Power (%) 100 80 Safe Operating Area 60 40 20 0 - 40 - 20 www.aimtec.com F 051e R11.F 0 20 40 60 Ambient Temperature 80 85 100 ºC Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2GW-Z 2 Watt | DC-DC Converter Test Circuits Conducted Emissions: Models AM2GW-24XX-Z AM2GW-48XX-Z C1 1210,225K/100V,X7R, 2pcs 1210,105k/100V,X7R L1 6.8µH 56µH Input Reflected Ripple current: Lin Vin+ Test Point + Cin Vin- - Lin Cin Vo+ Aimtec DC-DC Converter 12µH 47µF, ESR<1Ω at 100KHz RL (Full Load) Vo- Measurement taken at nominal input and full load. www.aimtec.com F 051e R11.F Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2GW-Z 2 Watt | DC-DC Converter Typical Efficiency Example Charts NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R11.F Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only