Specification
Input
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
• 0.4 A for AEH15, at 230 VAC
0.7 A for AEH24, at 230 VAC
Inrush Current
• 15/30 A max at 115/230 VAC 100% load,
cold start
Earth Leakage Current • <0.5 mA max at 115 VAC/60Hz
<0.75 mA max at 230 VAC/50Hz
Output
Output Voltage
• See tables (factory set). Non-standard
voltages available - contact sales
Initial Set Accuracy
• 5%
Start Up Delay
• 2 s max
Hold Up Time
• 20 ms min at full load and 115 VAC
Line Regulation
• See tables
Load Regulation
• See tables
Transient Response
• 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 2% pk-pk, 20 MHz BW
Overvoltage Protection • 112-132% Vnom, auto reset
Overload Protection
• 112-132% of nominal, auto recovery
Temperature
• ±0.04% /˚C max
Coefficient
General
Efficiency
Isolation
MTBF
• Up to 85%
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 100 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 ˚C to +70 ˚C, derate linearly from
full load at +40 ˚C to half load at +70 ˚C
Operating Humidity
• 5-95 % RH, non-condensing
Storage Temperature
• -40 ˚C to +85 ˚C
Vibration
• 2 g on 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
•
•
•
•
•
•
•
•
•
EN55022 level B, conducted and radiated
EN61000-3-2, Class A
EN61000-3-3
EN61000-4-2, level 2 Perf Criteria A
EN61000-4-3, level 3 Perf Criteria A
EN61000-4-4, level 2 Perf Criteria A
EN61000-4-5, level 3 Perf Criteria A
EN61000-4-6, level 2 Perf Criteria A
EN61000-4-11 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
• EN60950, UL60950,
CSA C22.2 No. 950 per cUL,
UL60950
Output
Power
8.25 W
12.00 W
12.00 W
15.00 W
15.00 W
15.00 W
15.00 W
15.00 W
15.00 W
15.00 W
15.00 W
Output Voltage
Nominal(1)
3.3 V
5.0 V
7.0 V
10.0 V
12.0 V
15.0 V
18.0 V
24.0 V
30.0 V
36.0 V
48.0 V
Output Current
Minimum
Maximum
0.0 A
2.50 A
0.0 A
2.40 A
0.0 A
1.70 A
0.0 A
1.50 A
0.0 A
1.25 A
0.0 A
1.00 A
0.0 A
0.80 A
0.0 A
0.62 A
0.0 A
0.50 A
0.0 A
0.40 A
0.0 A
0.30 A
Total
Regulation(2)
7%
5%
5%
5%
5%
5%
5%
5%
5%
3%
3%
Model
Number
AEH15US03
AEH15US05
AEH15US07
AEH15US10
AEH15US12
AEH15US15
AEH15US18
AEH15US24
AEH15US30
AEH15US36
AEH15US48
Notes
1. Factory-set non-standard outputs available in single output versions.
2. Total regulation includes initial set accuracy, line and load regulation.
Mechanical Details
Notes
1. Dimensions shown in inches (mm).
2. Tolerance 0.02 (0.5) max.
3. Output connector is 5.5mm outer diameter barrel.
Inner diameter is 2.5mm with centre positive (+) and
outer shell negative (-).
4. Output cable length is 72.0 (1830).
5. Optional output connectors available. Contact sales
office.
6. Weight 0.3 lb (135 g) approx.
7. For UK mains lead order part: UK-MAINS-IEC.
For European mains lead order part: EU-MAINS-IEC.
1.5
(38.0)
AC Input
IEC 320 Inlet
1.42
(36.0)
3.58 (91.0)
Models and Ratings
Output
Power
15.00 W
20.00 W
22.00 W
24.00 W
24.00 W
24.00 W
24.00 W
24.00 W
24.00 W
24.00 W
Output Voltage
Nominal(1)
5.0 V
7.0 V
10.0 V
12.0 V
15.0 V
18.0 V
24.0 V
30.0 V
36.0 V
48.0 V
Output Current
Minimum
Maximum
0.0 A
3.00 A
0.0 A
2.80 A
0.0 A
2.20 A
0.0 A
2.00 A
0.0 A
1.60 A
0.0 A
1.30 A
0.0 A
1.00 A
0.0 A
0.80 A
0.0 A
0.66 A
0.0 A
0.50 A
Total
Regulation(2)
5%
5%
5%
5%
5%
5%
3%
3%
3%
2%
Model
Number
AEH24US05
AEH24US07
AEH24US10
AEH24US12
AEH24US15
AEH24US18
AEH24US24
AEH24US30
AEH24US36
AEH24US48
Notes
1. Factory-set non-standard outputs available in single output versions.
2. Total regulation includes initial set accuracy, line and load regulation.
Mechanical Details
AC Input
IEC 320 Inlet
Notes
1. Dimensions shown in inches (mm).
2. Tolerance 0.02 (0.5) max.
3. Output connector is 5.5mm outer diameter barrel.
Inner diameter is 2.5mm with centre positive (+) and
outer shell negative (-).
4. Output cable length is 72.0 (1830).
5. Optional output connectors available. Contact sales
office.
6. Weight 0.47 lb (215 g) approx.
7. For UK mains lead order part: UK-MAINS-IEC.
For European mains lead order part: EU-MAINS-IEC.
4.17 (106.0)
1.18
(30.0)
2.56 (65.0)
08-Nov-07