AIMTEC AM1S-1212S-NZ 1 watt | dc-dc converter Datasheet

Series AM1S-NZ
1 Watt | DC-DC Converter
FEATURES:
•
•
•
•
•
•
•
RoHS compliant
4 Pin SIP Package
Low ripple and noise
High efficiency up to 81%
Operating temperature -40oC to + 85oC
Input / Output isolation 1000 and 3000VDC
Pin compatible with multiple manufacturers
Models
Single output
Model
Output
Voltage
(V)
Input Voltage
(V)
AM1S-0505S-NZ
AM1S-0509S-NZ
AM1S-0512S-NZ
AM1S-0515S-NZ
AM1S-1205S-NZ
AM1S-1209S-NZ
AM1S-1212S-NZ
AM1S-1215S-NZ
AM1S-2405S-NZ
AM1S-2409S-NZ
AM1S-2412S-NZ
AM1S-2415S-NZ
AM1S-0505SH30-NZ
Output Current
max
(mA)
Isolation
(VDC)
Efficiency
(%)
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
21.6-26.4
21.6-26.4
21.6-26.4
21.6-26.4
5
9
12
15
5
9
12
15
5
9
12
15
200
110
83
67
200
110
83
67
200
110
83
67
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
78
79
80
78
78
80
81
79
79
80
81
79
4.5-5.5
5
200
3000
70
Input Specifications
Parameters
Voltage range
Nominal
Typical
5
12
24
4.5-5.5
10.8-13.2
21.6-26.4
Filter
Maximum
Units
VDC
Capacitor
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
Typical
60 sec
Rated
Units
1000 or 3000
VDC
MOhm
pF
Maximum
Units
> 1000
60
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Line voltage regulation (Single)
Load voltage regulation (Single)
Temperature coefficient
Ripple & Noise
Conditions
Typical
See tolerance graph
Momentary (1 sec)
±1.2
10
±0.03
75
For 1.0% of Vin
Load 10 – 100%
At 20MHz Bandwidth
%
%
%/oC
mV p-p
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
www.aimtec.com
F 051e R11.I
Conditions
Typical
100% load
Without derating
150
Maximum
Units
90
KHz
o
C
o
C
o
C
-40 to +85
-55 to +125
Free air convection
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1S-NZ
1 Watt | DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Typical
Maximum
Units
%
Humidity
90
Case material
Plastic UL94-VO
Weight
1.8
g
Dimensions (L x W x H)
0.46 x 0.24 x 0.37 inches 11.70 x 6.00 x 9.50 mm
MTBF
>1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Safety Specifications
Parameters
Standards
Agency approvals
IEC60950-1 :2001
UL and CE for 1000VDC models
Pin Out Specifications
Pin
Single
1
2
3
4
- V Input
+V Input
-V Output
+V Output
Dimensions
11.70
(0.46)
6.00
(0.24)
PRINTED
FACE
10.00
(0.39)
9.50
(0.37)
0.50
(0.02)
4.10
.
(0.16)
2.54
(0.10 )
0.50
(0.02)
0.90
(0.04)
0.30
(0.01)
6.00
(0.24)
0.50
(0.02)
www.aimtec.com
F 051e R11.I
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1S-NZ
1 Watt | DC-DC Converter
Typical Characteristics
Tolerance Envelope Graph
+10%
Typic
+5%
+2.5%
line
-2.5%
Output Voltage (%)
Nominal
Voltage
al loa
d
-7.5%
10%
50%
100%
Output Current (%)
External capacitor
Vin
(VDC)
5
12
24
-
External
capacitor
(uF)
4.7
2.2
1
Filtering
Vout
(VDC)
5
9
12
15
External
capacitor
(uF)
10
4.7
2.2
1
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary
based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C,
humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all
internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for
release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications
which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at
www.aimtec.com.
www.aimtec.com
F 051e R11.I
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages