Sensortechnics HDIM010DBY8H3 Amplified pressure sensor Datasheet

HDI Series
Amplified pressure sensors
FEATURES
· 10 mbar to 5 bar,
absolute, gage or differential pressure
· Digital I2C-bus and analog output
· Precision ASIC signal conditioning
· Calibrated and temperature
compensated
· SMT and DIP housings
· RoHS compliant
· Sensortechnics PRO services
MEDIA COMPATIBILITY
To be used with non-corrosive, non-ionic working
fluids such as clean dry air, dry gases and the like.
SPECIFICATIONS
ELECTRICAL CONNECTION
Maximum ratings
Supply voltage VS
HDI...3
HDI...5
Output current
Sink
Source
2.7 ... 3.3 VDC
4.5 ... 5.5 VDC
max. 6.50 VDC
E / 11650 / A
1
2
1 mA
1 mA
Lead specifications
Average preheating temperature gradient 2.5 K/s
Soak time
ca. 3 min
Time above 217°C
50 s
Time above 230°C
40 s
Time above 250°C
15 s
Peak temperature
260°C
Cooling temperature gradient
-3.5 K/s
Temperature ranges5
Compensated
Operating
Storage
+Vs
4
6
Vout
SDA
SCL
3
GND
0 ... +85 °C
-20 ... +85 °C
-40 ... +125 °C
1/11
www.sensortechnics.com
HDI Series
Amplified pressure sensors
PRESSURE SENSOR CHARACTERISTICS
(TA = 25 °C)
Part no.
Operating pressure
Proof pressure1
Burst pressure2
HDIM010...B...
HDIM020...B...
HDIM050...B...
HDIM100...B...
HDIM200...B...
HDIM500...B...
HDIB001...B...
HDIM010...U...
HDIM020...U...
HDIM050...U...
HDIM100...U...
HDIM200...U...
HDIM500...U...
HDIB001...U...
HDIB002...U...
HDIB005...U...
HDI0611AR...
HDI0811AR...
0...±10 mbar
0...±20 mbar
0...±50 mbar
0...±100 mbar
0...±200 mbar
0...±500 mbar
0...±1 bar
0...10 mbar
0...20 mbar
0...50 mbar
0...100 mbar
0...200 mbar
0...500 mbar
0...1 bar
0...2 bar
0...5 bar
600...1100 mbar(a)
800...1100 mbar(a)
150 mbar
150 mbar
210 mbar
300 mbar
1 bar
1 bar
2 bar
150 mbar
150 mbar
210 mbar
300 mbar
1 bar
1 bar
2 bar
4 bar
7 bar
2 bara
2 bara
200 mbar
200 mbar
350 mbar
500 mbar
1.5 bar
1.5 bar
3 bar
200 mbar
200 mbar
350 mbar
500 mbar
1.5 bar
1.5 bar
3 bar
6 bar
7 bar
3 bara
3 bara
Other pressure ranges are available on request. Please contact Sensortechnics.
Specification notes:
1. Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters
of the sensing element.
2. Burst pressure is the maximum pressure which may be applied without causing damage to the sensing element or leaks to
the housing.
3. Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure.
4. Total accuracy is the combined error from offset and span calibration, linearity, pressure hysteresis, and temperature
effects. Linearity is the measured deviation based on a straight line. Hysteresis is the maximum output difference at any point
within the operating pressure range for increasing and decreasing pressure. Calibration errors include the deviation of offset
and full scale from nominal values.
5. Extended temperature ranges on request. Please contact Sensortechnics.
6. Max. delay time between pressure change at the pressure die and signal change at the output.
7. The response time depends on the adjusted internal A/D resolution of the sensor. For 12 bit it is typ. 0.5 ms. Other A/D resolutions
and reponse time are available on request. Please contact Sensortechnics for further information.
8. Sensors with lower current consumption are available on request. Please contact Sensortechnics for further information.
E / 11650 / A
2/11
www.sensortechnics.com
HDI Series
Amplified pressure sensors
PERFORMANCE CHARACTERISTICS
(VS = 5.0 VDC, TA = 25°C, analog output signal is ratiometric to VS, digital output signal is not ratiometric to VS)
All HDI...P5 devices (Prime Grade, VS = 5.0)
Characteristics
all barometric devices
Total accuracy (0...85°C)4
all other devices
Response delay6, 7
A/D resolution7
D/A resolution
Current consumption8
All HDI...R...P5 (barometric devices)
Characteristics
Min.
Typ.
Max.
±1.0
±0.5
0.5
12
5
Typ.
%FSS
ms
11
Min.
Units
bi t
mA
Max.
Units
A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC
Output at min. specified pressure
Full scale span (FSS)3
Full scale output
0.46
4.46
0.50
4.00
4.50
0.54
V
4.54
D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC
Output at min. specified pressure
Full scale span (FSS)3
Full scale output
3015
29228
3277
26214
29490
3539
29752
Min.
Typ.
Max.
counts
All HDI...U...P5 (unidirectional devices)
Characteristics
Units
A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC
Zero pressure offset
Full scale span (FSS)3
Full scale output
0.48
4.48
0.50
4.00
4.50
0.52
V
4.52
D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC
Zero pressure offset
Full scale span (FSS)3
Full scale output
3146
All HDI...B...P5 (bidirectional devices)
Characteristics
29359
3277
26214
29490
3408
29621
Min.
Typ.
Max.
counts
Units
A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC
Zero pressure offset
Full scale span (FSS)3
Output
2.48
at max. specified pressure
at min. specified pressure
4.48
0.48
2.50
4.00
4.50
0.50
2.52
4.52
0.52
V
D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC
Zero pressure offset
Full scale span (FSS)3
Output
E / 11650 / A
16252
at max. specified pressure
at min. specified pressure
29359
3146
16384
26214
29490
3277
16515
29621
3408
counts
3/11
www.sensortechnics.com
HDI Series
Amplified pressure sensors
PERFORMANCE CHARACTERISTICS
(VS = 5.0 VDC, TA = 25°C, analog output signal is ratiometric to VS, digital output signal is not ratiometric to VS)
All HDI...H5 devices (High Grade, VS = 5.0)
Characteristics
Total accuracy (0...85°C)4
Response delay6, 7
A/D resolution7
D/A resolution
Current consumption8
Min.
Typ.
Max.
±1.5
0.5
12
11
5
Units
%FSS
ms
bi t
mA
All HDI...U...H5 (unidirectional devices) and HDI...R...H5 (barometric devices)
Characteristics
Min.
Typ.
Max.
Units
A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC
Output at min. specified pressure
Full scale span (FSS)3
Full scale output
0.44
4.44
0.50
4.00
4.50
0.56
V
4.56
D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC
Output at min. specified pressure
Full scale span (FSS)3
Full scale output
2883
29097
3277
26214
29490
3670
29883
Min.
Typ.
Max.
counts
All HDI...B...H5 (bidirectional devices)
Characteristics
Units
A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC
Zero pressure offset
Full scale span (FSS)3
Output
2.44
at max. specified pressure
at min. specified pressure
4.44
0.44
2.50
4.00
4.50
0.50
2.56
4.56
0.56
V
D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC
Zero pressure offset
Full scale span (FSS)3
Output
E / 11650 / A
15990
at max. specified pressure
at min. specified pressure
29097
2883
16384
26214
29490
3277
16777
29883
3670
counts
4/11
www.sensortechnics.com
HDI Series
Amplified pressure sensors
PERFORMANCE CHARACTERISTICS
(VS = 3.0 VDC, TA = 25°C, analog output signal is ratiometric to VS, digital output signal is not ratiometric to VS)
All HDI...P3 devices (Prime Grade, VS = 3.0)
Characteristics
all barometric devices
Total accuracy (0...85°C)4
all other devices
Response delay6, 7
A/D resolution7
D/A resolution
Current consumption8
All HDI...R...P3 (barometric devices)
Characteristics
Min.
Typ.
Max.
±1.0
±0.5
0.5
12
3
Typ.
%FSS
ms
11
Min.
Units
bi t
mA
Max.
Units
A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC
Output at min. specified pressure
Full scale span (FSS)3
Full scale output
0.23
2.23
0.25
2.00
2.25
0.27
V
2.27
D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC
Output at min. specified pressure
Full scale span (FSS)3
Full scale output
All HDI...U...P3 (unidirectional devices)
Characteristics
2512
24357
2731
21845
24575
2949
24794
Min.
Typ.
Max.
counts
Units
A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC
Zero pressure offset
Full scale span (FSS)3
Full scale output
0.24
2.24
0.25
2.00
2.25
0.26
V
2.26
D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC
Zero pressure offset
Full scale span (FSS)3
Full scale output
2621
24466
2731
21845
24575
2840
24684
Min.
Typ.
Max.
counts
All HDI...B...P3 (bidirectional devices)
Characteristics
Units
A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC
Zero pressure offset
Full scale span (FSS)3
Output
1.24
at max. specified pressure
at min. specified pressure
2.24
0.24
1.25
2.00
2.25
0.25
1.26
2.26
0.26
V
D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC
Zero pressure offset
Full scale span (FSS)3
Output
E / 11650 / A
13545
at max. specified pressure
at min. specified pressure
24466
2621
13653
21845
24575
2731
13762
24684
2840
counts
5/11
www.sensortechnics.com
HDI Series
Amplified pressure sensors
PERFORMANCE CHARACTERISTICS
(VS = 3.0 VDC, TA = 25°C, analog output signal is ratiometric to VS, digital output signal is not ratiometric to VS)
All HDI...H3 devices (High Grade, VS = 3.0)
Characteristics
Total accuracy (0...85°C)4
Response delay6, 7
A/D resolution7
D/A resolution
Current consumption8
Min.
Typ.
Max.
±1.5
0.5
12
11
3
Units
%FSS
ms
bi t
mA
All HDI...U...H3 (unidirectional devices) and HDI...R...H3 (barometric devices)
Characteristics
Min.
Typ.
Max.
Units
A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC
Output at min. specified pressure
Full scale span (FSS)3
Full scale output
0.22
2.22
0.25
2.00
2.25
0.28
V
2.28
D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC
Output at min. specified pressure
Full scale span (FSS)3
Full scale output
2403
24248
2731
21845
24575
3058
24903
Min.
Typ.
Max.
counts
All HDI...B...H3 (bidirectional) devices
Characteristics
Units
A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC
Zero pressure offset
Full scale span (FSS)3
Output
1.22
at max. specified pressure
at min. specified pressure
2.22
0.22
1.25
2.00
2.25
0.25
1.28
2.28
0.28
V
D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC
Zero pressure offset
Full scale span (FSS)3
Output
E / 11650 / A
13325
at max. specified pressure
at min. specified pressure
24248
2403
13653
21845
24575
2731
13981
24903
3058
counts
6/11
www.sensortechnics.com
HDI Series
Amplified pressure sensors
I²C BUS
Introduction
DATA valid (D): State of data line represents valid data when,
after START condition, data line is stable for duration of
HIGH period of clock signal. Data on line must be
changed during LOW period of clock signal. There is
one clock pulse per bit of data.
The HDI is capable to generate a digital output signal. The
device runs a cyclic program, which will store a corrected
pressure value with 12 bit resolution about every 250 µs
within the output registers of the internal ASIC. In order to
use the sensor for digital signal readout, it should be connected to a bidirectional I²C-bus.
Acknowledge (A): Data is transferred in pieces of 8 bits
(1 byte) on serial bus, MSB first. After each byte receiving
device – whether master or slave – is obliged to pull
data line LOW as acknowledge for reception of data.
Master must generate an extra clock pulse for this purpose. When acknowledge is missed, slave transmitter
becomes inactive. It is on master either to send last command again or to generate STOP condition in that case.
According to the I²C-bus specification, the bus is controlled by a master device, which generates the clock signal,
controls the bus access and generates START and STOP
conditions. The HDI is designed to work as a slave, hence
it will only respond to requests from a master device.
Digital I²C interface
Slave address: The I²C-bus master-slave concept requires
a unique address for each device. The HDI has a
preconfigured slave address (1111000xb). By factory programming it is possible to define a secondary slave
address additional to the general one. According to I²C
specification 127 different addresses are available. The
sensor will then listen to both slave addresses. After
generating a START condition the master sends the
address byte containing a 7 bit address followed by a
data direction bit (R/W). A "0" indicates a transmission
from master to slave (WRITE), a "1" indicates a data
request (READ).
The HDI complies with the following protocol (Fig. 1):
Bus not busy: During idle periods both data line (SDA) and
clock line (SCL) remain HIGH.
START condition (S): HIGH to LOW transition of SDA line
while clock (SCL) is HIGH is interpreted as START condition. START conditions are always generated by the
master. Each initial request for a pressure value has to
begin with a START condition.
STOP condition (P): LOW to HIGH transition of SDA line while
clock (SCL) is HIGH determines STOP condition. STOP
conditions are always generated by the master. More than
one request for the current pressure value can be transmitted without generation of intermediate STOP condition.
DATA operation: The sensor starts to send 2 data bytes containing the current pressure value as a 15 bit information
placed in the output registers.
SCL
SDA
START
condition
Data
valid
1
S Slave Address R/W A
Data allowed
to change
Data Byte 1
A
STOP
condition
Data Byte 2
Read out of first pressure value
generated by master
generated by slave
A
Data Byte 1
P
Read out of n pressure values (optional)
S = START condition
Data Byte 1 = High Byte (MSB first)
A = Acknowledge
Data Byte 2 = Low Byte (LSB last)
P = STOP condition
Fig. 1:
I²C bus protocol
E / 11650 / A
7/11
www.sensortechnics.com
HDI Series
Amplified pressure sensors
I²C Interface Parameters
Parameter
Symbol
Input high level
Input low level
Output low level
Pull-up resistor
Load capacitance @ SDA
Input capacitance @ SDA/SCL
SCL clock frequency
Bus free time between STOP and START condition
Hold time (repeated) START condition, to first clock pulse
LOW period of SCL
HIGH period of SCL
Setup time repeated START condition
Data hold time
Data setup time
Rise time of both SDA and SCL
Fall time of both SDA and SCL
Setup time for STOP condition
Min.
Typ.
90
0
Max.
Unit
100
10
10
% of V s
Ω
500
C SD A
CI2C_IN
FSC L
tBUF
tHD.STA
tLOW
tHIGH
tSU.STA
tHD.DAT
tSU.DAT
tR
tF
tSU.STO
400
10
400
100*
1.3
0.8
1.3
0.6
1
0
0.2
pF
kHz
µs
0.3
0.3
0.6
* recommended
Note: Sensortechnics recommends communication speeds of at least 100 kHz (max. 400 kHz).
Please contact your nearest Sensortechnics sales office for further information.
tSU;DAT
tHD;DAT
tSU;STA tHD;STA
tR
tSU;STO tBUF
tHD;STA
tF
SCL
SDA
tHIGH
tLOW
SCL
SDA
Fig. 2:
Timing characteristics
E / 11650 / A
8/11
www.sensortechnics.com
HDI Series
Amplified pressure sensors
PHYSICAL DIMENSIONS
Different housing options are available on request. Please contact Sensortechnics.
HDI...E... (SMD, 2 ports same side)
15.0
7.5
Ø 2.3
High pressure port
19.5
2.54
0.46
12.85
8.35
4.1
3.2
4.0
7.0
9.1
6.3
9.9
0.7
third angle projection
dimensions in mm
HDI...F... (DIP, 2 ports same side)
15.0
7.5
Ø 2.3
12.85
8.35
0.46
High pressure port
19.5
2.54
4.1
3.2
9.1
15.15
0.7
6.3
9.25
7.0
third angle projection
dimensions in mm
E / 11650 / A
9/11
www.sensortechnics.com
HDI Series
Amplified pressure sensors
PHYSICAL DIMENSIONS (cont.)
Different housing options are available on request. Please contact Sensortechnics.
HDI...Y... (SMD, 1 port axial)
11.9
4.0
0.7
3 2 1
10.4
Pin
marking
15.79
Ø 2.69
15.0
4 5 6
6.9
3.1
2.54
0.46
8.0
third angle projection
dimensions in mm
HDI...Z... (DIP, 1 port axial)
11.9
9.25
Ø 2.7
15.0
0.7
10.4
21.05
8.0
6.9
3.1
2.54
0.46
third angle projection
dimensions in mm
E / 11650 / A
10/11
www.sensortechnics.com
HDI Series
Amplified pressure sensors
ELECTRICAL CONNECTION (cont.)
HDI...A...
(absolute)
HDI...G...
(gage)
4 5 6
HDI...D...
(differential)
6 5 4
3 2 1
Pin
marking
Pin
Connection
1
+Vs
2
+Vout
3
GND
4 5 6
1 2 3
Pin
marking
4
SD A
5
I / C*
6
SC L
3 2 1
* Internal connection.
Do not connect for any reason
Pin
marking
High pressure port
ORDERING INFORMATION
Series
Options
HDI
Pressure range
0611
0811
Pressure mode
600...1100 mbar A* Absolute
800...1100 mbar D Differential
M010
10 mbar G
M020
20 mbar
M050
50 mbar
M100
100 mbar
M200
200 mbar
M500
500 mbar
B 001
1 bar
(B001A)
1 bara
B 002
2 bar
B 005
5 bar
Gage
Note:
HDI
M050
Bidirectional
U
Unidirectional
R* Barometric
Housing
Porting
E* SMD, 2 ports
same side
8
Straight
Grade
Voltage
H High
3
3V
P Prime
5
5V
P
5
F* DIP, 2 ports
same side
Y** SMD, 1 port
axial
Z** DIP, 1 port
axial
* only available
from 1 bar
Example:
Calibration
B
G
* for pressure ranges
0611, 0811
U
* standard for differential
devices, "D"
** standard for absolute
and gage devices,
"A" and "G"
Y
8
Devices highlighted in grey are preferred stock items
Sensortechnics PRO services:
· Extended guarantee period of 2 years
· Custom product modifications and adaptations even for small quantities
· Advanced logistics models for supply inventory and short delivery times
· Technical support through application engineers on the phone or at your site
· Traceability of each sensor through serial numbers on request
· No product specification changes without customer notification
· No product obsolescence without very early prior notice
· Fastest possible technical response for design and QA engineers
· Long term product availability for your spares and service needs
... plus other services on request
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
E / 11650 / A
11/11
www.sensortechnics.com
Similar pages