Vicor MI-A22-MU Military input attenuator module Datasheet

TM
MI-IAM
Military Input Attenuator Modules
Features
Product Highlights
The MI-IAM is an accessory
product to Vicor’s MI-Series of
DC-DC converters that provides
the EMI/RFI filtering and transient
protection required in military
applications. Designed for use
with all 28V and 270V input
MI-200 or MI-J00 converters, the
MI-IAM can drive any number of
modules with output loads to 200W.
The MI-IAM meets the conducted
emissions specifications of MILSTD-461C/D and offers complete
input transient, surge, and spike
protection to the most severe
levels of MIL-STD-1275A and
704A. Reverse polarity protection
and overvoltage lockout provide
additional safeguards against
potentially damaging line
conditions. High power arrays can
be configured using the expansion
port capability of the MI-IAM.
" Inputs:
28Vdc and 270Vdc
" MIL-STD-461C/D EMI compliance
" Output power: Up to 200W from
any combination of MI-200 or
MI-J00 modules
" MIL-STD-810 environments
" Expansion port for additional power
" MIL-STD-704A & MIL-STD1275A
transients and spikes
" Short circuit protected
" Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7mm)
" Reverse polarity protection
Specifications
(At TBP = 25°C, nominal line and 75% load, unless otherwise specified)
PARAMETER
Input Characteristics
28Vdc modules
Steady state input
Input spike limit
270Vdc modules
TYP
MAX
UNITS
18.8
-600
-250
28
50
600
250
100
Vdc
Vdc
Vdc
Vdc
Vdc
20
400
800
600
500
Amps
Vdc
Vdc
Vdc
Vdc
Vdc
4
1.5
125
Amps
Watts
% Iin
Input surge limit
Overvoltage shutdown 50
Reverse polarity protection
Recommended fuse
Steady state input
125
Input spike limit
All models
MIN
270
-600
Input surge limit
Overvoltage shutdown 400
Reverse polarity protection
Recommended fuse
No load power dissipation
Inrush current
0.5
110
10µS, 50Ω
100µS, 15mJ
100mS, 0.5Ω
100mS, automatic recovery
Shunt diode: input fuse required
F03A type
Steady state, l in 10mS
Input power leads Conducted emissions
CE01, CE03, CE07
CE101, CE102
Conducted susceptibility CS01, CS02, CS06
CS101, CS114, CS116
Isolation Characteristics
Input to base
Output to base
Environmental (MIL-STD-810)
Altitude - method 500.2
Humidity - method 507.2
Acceleration - method 513.3
Vibration - method 514.3
Shock - method 516.3
Reliability (MIL-HDBK-217F)
25°C Ground Benign: G.B.
50°C Naval Sheltered: N.S.
65°C Airborne Inhabited Cargo: A.I.C.
Thermal Characteristics
Efficiency
Baseplate to sink
Operating temperature, baseplate
Storage temperature
Mechanical Specifications
Weight
1 of 2
10µS, 50Ω per MIL-STD-704A
100µS, 15mJ per MIL-STD-1275A
60mS, 0.5Ω per MIL-STD-1275A
100mS, automatic recovery
Shunt diode: input fuse required
F03A type
EMC Characteristics; MIL-STD-461C/D
Output Characteristics
Clamp voltage
28Vdc input
270Vdc input
Output power
Overload protection 28Vdc input
270Vdc input
MI-IAM 04/03
NOTES
60
420
250
20
4
MIL-STD-461C
MIL-STD-461D
MIL-STD-461C
MIL-STD-461D
Vdc
Vdc
Watts
Amps
Amps
threshold; auto recovery
} Foldback
with latched shutdown after 10mS
1,500
1,500
Vrms
Vrms
70,000
86 / 240
9
20
40
feet
% / hours
g's
g's
g's
3,352,133
804,512
653,666
97
0.14
3 (85)
1 min.
1 min.
Procedure II
Procedure 1, cycle 1
Procedure
Procedure 1, category 6
Procedure 1
hours
hours
hours
%
°C/Watt
100
°C
See product grade specifications
125
°C
See product grade specifications
ounces (grams)
MI-IAM Model Selection Chart
Model Number
Nominal Input Voltage
Input Range
Compatible MI-Series
Converter
MI-A22-MU
28Vdc
18.8–50Vdc
MI-22x and MI-J2x-Mx
M–grade
MI-A66-MU
270Vdc
125–400Vdc
MI-26x and MI-J6x-Mx
M–grade
MI-A22-IU
28Vdc
18.8–50Vdc
MI-22x and MI-J2x-Ix
I–grade
MI-A66-IU
270Vdc
125–400Vdc
MI-26x and MI-J6x-Ix
I–grade
Product Grade Specifications
PARAMETER
PRODUCT GRADE
I - Grade
M - Grade
Storage temperature
-55°C to +125°C
-65°C to +125°C
Operating temperature (baseplate)
-40°C to +100°C
-55°C to +100°C
12 hours, 25 cycles
96 hours, 200 cycles
12 cycles
-65°C to +100°C
12 cycles
-65°C to +100°C
-40°C, +80°C
-55°C, +80°C
Power cycling burn-in
Temperature cycled with power off
17°C per minute rate of change
Test data supplied at these temperatures*
Warranty
Environmental compliance
Derating
2 years
2 years
MIL-STD-810
MIL-STD-810
NAVMAT P - 4855-1A
NAVMAT P - 4855-1A
*Test data available for review or download from vicorpower.com
MI-IAM Safe Operating Area*
270Vdc Input
VOLTS-PEAK VALUE OF SPIKE VOLTAGE
VOLTS-PEAK VALUE OF SPIKE VOLTAGE
28Vdc Input
600
500
400
Ratings Exceeded
300
200
100
OVP
0
50V
-100
-200
Reverse Polarity
Protection
-300
-400
-500
-600
10-6
1µs
10-5
10µs
10-4
100µs
10-3
1ms
10-2
10ms
10-1
100ms
Ratings Exceeded
800
600
OVP
400
0
200
Reverse Polarity
Protection
400
600
10-6
1µs
100
1s
500V
400V
200
10-5
10µs
10-4
100µs
10-3
1ms
10-2
10ms
10-1
100ms
100
1s
TIME (SECONDS)
TIME (SECONDS)
* Refer to input characteristics
Mechanical Drawing
Typical Connection Diagram
2.28
(57,9)
0.49
(12,4)
0.30±.015
(7,6)±(0,38)
0.65
(16,5)
1.30
(33,0)
4
9
3
2.10
(53,4)
0.080 Dia (2) places
Solder plate
over copper alloy
8
MI-IAM
VI-IAM
7
2
6
1
5
1.40
1.00 (35,6)
0.70 (25,4)
0.40 (17,8)
(10,2)
0.35± 0.015
(8,9)±(0,38)
0.15
(3,8)
FULL R
0.15
(3,8)
4700 pF
Pin #
1
2
3
4
5
6
7
8
9
+
–
+In
+Out
+In
-In
Gate In
Parallel
Gate Out
-In
-Out
MI-IAM
+In
+Out
Gate In
Gate Out
+S
Trim
-S
-In
-Out
C1
MI-Converter
4700 pF
Input Voltage Range Capacitance (C1)
28Vdc (18.8-50V)
390µF (Max.)
270Vdc (125-400V)
27µF (Max.)
0.040 (1,0) Dia (7) places
Solder plate
over copper alloy
2.40
(61,0)
Product ID
this surface
1.90
(48,3)
Function
+In
+In
–In
–In
+Out
Gate In
Parallel
Gate Out
–Out
0.30
(7,6) Min.
0.22
(5,6) Min.
0.50
(12,7)
1.75
(44,4) Max.
+0.030 (0,76)
-0.000 (0)
.01
0.12
(3,0)
Aluminum Base
MI-IAM 04/03
2 of 2
Similar pages