Proven Reliabilit y GP SERIES ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS 100V to 6kV at 1W PRODUCT SELECTION TABLE PRODUCT PRODUCTDESCRIPTION DESCRIPTION The GP Series is a line of miniature DC to HV DC converters providing 100V to 6kV, positive or negative in a compact PC mount package. This line features low power consumption, making it ideal for portable, battery powered applications. The isolated output is proportional to the input, and is linear from approximately 0.7 volts in. A low noise quasisinewave oscillator and shielded transformer provide clean, reliable DC to HV DC conversion with low EMI and RFI. The isolated output allows for user selectable output polarity. No minimum load is required. Output Voltage vs. Input Voltage 100 90 Output Voltage % 80 70 60 50 MODEL OUTPUT VOLTAGE*2 OUTPUT CURRENT*1 GP01 100V 10mA GP02 200V 5mA GP03 300V 3.3mA GP05 500V 2mA GP06 600V 1.67mA GP08 800V 1.25mA GP10 1kV 1mA GP12 1.2kV 840uA GP15 1.5kV 660uA GP20 2kV 500uA GP25 2.5kV 400uA GP30 3kV 340uA GP40 *5 4kV 250uA GP50 *5 5kV 200uA GP60 *5 6kV 166uA 40 30 20 10 0 0 1 2 3 4 5 6 7 8 9 10 11 12 Input Voltage APPLICATIONS • Portable, Battery Powered • Sustaining Ion Pumps • Vacuum Gauges • Photomultiplier Tubes • Spectrometry • Electrostatic Chuck • Non-impact Printers • Field Generation • Piezo Devices • Electrophoresis OPTIONS FEATURES • Proportional Input/Output • Compact, PCB Mount Package • Low Power Consumption • Low Ripple, Low EMI / RFI • Short Circuit Protected • Input/Output Isolation • Low Leakage Current • Low Input/Output Coupling Capacitance • No External Components Required • No Minimum Load Required • MTBF: >2.31 million hrs per Bellcore TR-332 • UL Certified Encapsulant, Meets 94V-0 Flammability • RoHS Compliant • External Mounting Enclosure (AB Suffix) WWW.XPPOWER.COM 4728X01 PAGE 1 GP SERIES *3 ELECTRICAL SPECIFICATIONS REVERSIBLE MODEL OUTPUT VOLTAGE*2 OUTPUT CURRENT*1 INPUT CURRENT (NO LOAD) INPUT CURRENT (FULL LOAD) RIPPLE GP01 0 to 100V 10mA <45mA <150mA <0.75% GP02 0 to 200V 5mA <45mA <150mA <1.75% GP03 0 to 300V 3.3mA <45mA <125mA <0.50% GP05 0 to 500V 2mA <15mA <125mA <0.50% GP06 0 to 600V 1.67mA <15mA <125mA <0.50% GP08 0 to 800V 1.25mA <25mA <125mA <0.75% GP10 0 to 1kV 1mA <15mA <125mA <0.75% GP12 0 to 1.2kV 840uA <15mA <125mA <0.75% GP15 0 to 1.5kV 660uA <20mA <125mA <0.75% GP20 0 to 2kV 500uA <30mA <130mA <0.75% GP25 0 to 2.5kV 400uA <30mA <130mA <1.0% GP30 0 to 3kV 340uA <40mA <130mA <1.0% GP40*5 0 to 4kV 250uA <50mA <130mA <1.0% GP50 *5 0 to 5kV 200uA <75mA <150mA <1.5% GP60*5 0 to 6kV 166uA <85mA <175mA <1.0% WWW.XPPOWER.COM 4728X01 PAGE 2 GP SERIES *3 ELECTRICAL SPECIFICATIONS PARAMETER VALUE INPUT VOLTAGE 0 to 12V TURN-ON VOLTAGE <0.7V ISOLATION < +/-3.5kV BIAS INPUT CAPACITANCE 120uF RESPONSE TIME <20ms OUTPUT VOLTAGE TOLERANCE +/-3% (Full Load, 100% output voltage) REGULATION <10% VARIATION OVER LOAD RANGE FREQUENCY 60-400kHz OPERATING TEMPERATURE -20°C to +70°C (CASE) STORAGE TEMPERATURE -20°C to +105°C *4 WWW.XPPOWER.COM 4728X01 PAGE 3 GP SERIES GP01 thru GP60 MECHANICAL SPECIFICAIONS RECOMMENDED PCB LAYOUT TOP VIEW HIGH VOLTAGE TOP VIEW 1.50 (38.10) 0.15 (3.81) 0.800 (20.32) 1.50 (38.10) 0.20 (5.08) 0.63 (16.00) 1.200 (30.48) 4 2 1.200 (30.48) 1 3 0.15 (3.81) 0.35 (8.89) RECOMMENDED HOLE & PAD O.D. SIZE: Ø 0.052 (1.32 )& Ø 0.082 (2.08 ) 4 PLACES 0.031 Ø PC PIN (0.79) 4 PLACES DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS) DIMENSIONAL TOLERANCES: .XX = +- 0.02 (0.51), .XXX = +- 0.005 ( 0.127) PARAMETER VALUE PIN # FUNCTION WEIGHT Weight: 1.40 OZ (40 Grams) 1 (+) Input VOLUME 1.4 cubic Inches (23 cubic centimeters) 2 (-) Input DIMENSIONS 1.5L (38.1L) x 1.5W (38.1L) x 0.63H (16.0H) 3 (+) Output CASE MATERIAL Diallyl Phthalate (DAP) 4 (-) Output WWW.XPPOWER.COM 4728X01 PAGE 4 GP SERIES – ACCESSORY EXTERNAL EMI/RFI SHIELD 4-40 SOLDERABLE GROUNDING STUD 2 PLACES 2.40 (60.96) Ø 0.140 (3.56) THRU 2 PLACES 0.300 (7.62) 0.300 (7.62) TOP VIEW 0.80 (20.32) SIDE VIEW 0.20 (5.08) 2.000 (50.80) 0.31 (7.87) 1.60 (40.64) 1.60 (40.64) HIGH VOLTAGE 0.68 (17.27) 0.40 (10.16) DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS) DIMENSIONAL TOLERANCES: .XX = +- 0.02 (0.51), .XXX = +- 0.005 ( 0.127) PARAMETER VALUE PARAMETER VALUE BOX SIZE See Table GROUND Black Anodized Aluminum MATERIAL 0.03 (0.76mm) Aluminum DIMENSIONS WITH TAB 2.4L (60.96) x 1.6W (40.64) x 0.68H (17.27) MOUNTING Two Tabs With Thru-Holes DIMENSIONS WITHOUT TAB 1.6L (40.64) x 1.6W (40.64) x 0.68H (17.27) SHIELD DESCRIPTION The “AB” Series provides low cost EMI/RFI shielding and rugged mounting for XP EMCO High Voltage DC to DC converters. These five-sided aluminum enclosures feature a durable, non-conductive black anodized finish. The enclosures are manufactured at our own sheet metal fabrication facility, which allows for low cost and stock delivery. Add an “AB” suffix to the model number for a factory-installed enclosure (e.g. E10AB). Contact our sales department by phone, fax or email for immediate attention. WWW.XPPOWER.COM APPLICATION INFORMATION On models with outputs of 3kV or higher, special care must be taken to ensure adequate spacing and insulation between the metal can and the high voltage output. Single sided layout, encapsulants or conformal coating may be required. Case grounding stud must be connected to ground. Case ground is not internally connected to (-) input. 4728X01 PAGE 5 GP SERIES BLOCK DIAGRAM (+) Output (+) In Rectifier & Multiplier Oscillator (-) In (-) Output Transformer OPTION CODE TABLE OPTION OPTIONS Shielding and Mounting Enclosure ORDER CODE MODELS AB ALL HOW TO ORDER PART NUMBER SELECTOR: Model Number: GP10AB Model Output Voltage (See table) Shielding & Mounting Enclosure (Optional) EXAMPLE: GP10AB (GP-Model, 10-Output Voltage, AB-Shielding & Mounting Enclosure) * Notes: 1. At maximum rated output voltage. 2. Output voltage is load dependent. Under light or no load conditions, reduce input voltage so maximum rated output voltage is not exceeded. 3. Specifications after 30 minute warm up, full load, at 25C unless otherwise indicated. 4. Proper thermal management techniques are required to maintain safe case temperature at maximum power output. 5. Models GP40, GP50 & GP60 do not have internal bleeder resistors on the output. Provisions must be made externally to discharge the output capacitors if this feature is desired. XP EMCO reserves the right to make changes on products and literature, including specifications, without notice. XP EMCO standard product models are not recommended for “copy-exact” applications or any other application restricting product changes. “Copy-exact” options are available. Please contact an XP EMCO sales representative for more details. WWW.XPPOWER.COM 4728X01 PAGE 6