PETERMANN D914 High reliability for low cost Datasheet

FEATURES
PETERMANN
TECHNIK
- HIGH RELIABILITY FOR LOW COST
- WIDE FREQUENCY RANGE
- SMD PACKAGES WITH SMALL DIMENSIONS AND LOW PROFILE
- EXCELLENT ATTENUATION BEHAVIOUR
Time & Frequency Components
ONE - PORT & TWO - PORT SAW RESONATORS
TYPE
∆ f0* (MHz)
∆ f0 (kHz)
Insertion Loss (dB)
<2.5 for One-Port
433.02
SR433
+-75 / +-100
<7.5 for Two-Port
<2.5 for One-Port
+-75 / +-100
418.00
SR418
<7.5 for Two-Port
<2.5 for One-Port
SR318
318.00
+-75 / +-100
<7.5 for Two-Port
<2.5 for One-Port
SR315
315.00
+-75 / +-100
<7.5 for Two-Port
* The nominal center frequency (f0) range is from 200 MHz to 1 GHz
Other parameters and packages are available on request
PACKAGE
Freq.-Temp.-Coeff.
T0-39 / F-11 / 5x5 SMD
0.032 ppm/°C²
T0-39 / F-11 / 5x5 SMD
0.032 ppm/°C²
T0-39 / F-11 / 5x5 SMD
0.032 ppm/°C²
T0-39 / F-11 / 5x5 SMD
0.032 ppm/°C²
Insertion Loss (dB)
Package
SAW-FILTER FOR REMOTE CONTROL
TYPE
Center Frequency
(MHz)
dB
MHz
SF314
314.0
3
f0 +-0.35
2.5
T0-39 / F-11
SF315
315.0
3
f0 +-0.35
2.5
T0-39 / F-11
SF418
418.0
3
f0 +-0.35
2.5
T0-39 / F-11
SF433
433.92
3
f0 +-0.35
2.5
T0-39 / F-11
Insertion Loss (dB)
Package
Band Width
Other parameters and packages are available on request
SAW-FILTER FOR COMMUNICATION
TYPE
Center Frequency
(MHz)
dB
MHz
D150RFQ
138 ~ 174
3
f0 +-0.05
<5
F-11
D280RFQ
278 ~ 284
3
f0 +-0.05
<5
F-11
D150TFN
138 ~ 174
3
f0 +-4.0
<6.5
F-11
D280TFN
178 ~ 284
3
f0 +-3.3
<4.5
F-11
D450TFN
400 ~ 500
3
f0 +-4.0
<4.5
F-11
Band Width
Other parameters and packages are available on request
Other Typical D1106(110.592MHz), D304TFN(304 MHz), D325TFN(325 MHz), D388(388MHz), D930(930.5MHz)
Types
D450 (402/406/410/414/418/422/426/430/430/434/438/442/446/450/454/458/462/466/470/474/478/482/486/
490/492/494/498/502/506/510/514/518 MHz)
PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering
Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97
http://www.petermann-technik.de | [email protected]
PETERMANN
TECHNIK
Time & Frequency Components
SAW-FILTER FOR CORDLESS PHONE & COMMUNICATION
Band Width
TYPE
Center Frequency
(MHz)
dB
MHz
D45
45.36
3
D48
48.36
D45/48
Insertion Loss (dB)
Package
f0 +1
<5
SF-712
3
f0 +1
<5
SF-712
45.36/48.36
3
f0 +1
<5
SF-915
D903
903.75
3
f0 +-2
<5
F-11
D927
927.75
3
f0 +-2
<5
F-11
D886
886.0
3
f0 +-2
<4
F-11
D931
931.0
3
f0 +-2
<4
F-11
D914
914.0
3
f0 +-2
<4
F-11
D959
959.0
3
f0 +-2
<4
F-11
Insertion Loss (dB)
Package
<21
TO-39
WSWR max.
Package
Application
Other parameters and packages are available on request
SAW-FILTER FOR SATELLITE-RECEIVER
TYPE
Center Frequency
(MHz)
dB
MHz
D479.5B
479.5
3
f0 +13.5
Band Width
Other parameters and packages are available on request
SAW-FILTER FOR CELLULAR PHONE / RF-STAGE SERIES
TYPE
Center Frequency
(MHz)
D902
902.5
25 MHz
3.5 dB
2.5
3 x 3 mm SMD
FOR GSM
D947
947.5
25 MHz
3.5 dB
2.5
3 x 3 mm SMD
FOR GSM
D942
942.5
35 MHz
3.5 dB
2.5
3 x 3 mm SMD
FOR PDC/EGSM
D836
836.5
25 MHz
3.5 dB
2.5
3 x 3 mm SMD
FOR CDMA/AMPS
Pass-Band Width Insertion Loss max.
Other parameters and packages are available on request
PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering
Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97
http://www.petermann-technik.de | [email protected]
PETERMANN
TECHNIK
Time & Frequency Components
SAW-FILTER FOR CELLULAR PHONE / IF-STAGE SERIES
TYPE
Center Frequency
(MHz)
D881
881.5
25 MHz
D246
246.0
D400
D85
WSWR max.
Package
Application
3.5 dB
2.5
3 x 3 mm SMD
FOR CDMA/AMPS
+-80 MHz
8 dB
2.0 µs
5 x 5 mm SMD
FOR GSM
400.0
+-83 MHz
6 dB
1.0 µs
5 x 5 mm SMD
FOR GSM
85.38
+-300 MHz
15 dB
3.0 µs
7 x 5 mm SMD
FOR CDMA
Pass-Band Width Insertion Loss max.
Other parameters and packages are available on request
PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering
Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97
http://www.petermann-technik.de | [email protected]
PETERMANN
TECHNIK
Time & Frequency Components
PACKAGE DRAWINGS
TO-39
5 x 5 mm SMD
09.5max
3.5max
5.0 +- 0.2
5.0min
00.45
05.08
0.
75
0.
8
#3
1.0+0.1
-
5.0 +- 0.2
FUNCTION
INPUT
GROUND
OUTPUT
PIN
#1
#2
#3
#1
1.5max
#2
Unit:mm
0.6+0.1
1.20+0.15
-
1.27+0.1
-
F-11
3.3max
#1
#3
#2
#8
#2
#1
#4
#3
11.3max
#4
4.8max
#2
#4
#7
2.54+0.1
-
2.54 2.54 2.54
#1
#6
#3
5.0min
00.5
#5
2.08+0.15
-
PIN
#1
#2
#3
#4
FUNCTION
INPUT
GROUND
GROUND
OUTPUT
PIN
#1
#2
#3
#4
#5
#6
#7
#8
CONNECTION
GROUND
INPUT
GROUND
GROUND / CASE
GROUND
OUTPUT
GROUND
GROUND / CASE
Unit:mm
PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering
Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97
http://www.petermann-technik.de | [email protected]
Unit: mm
PETERMANN
TECHNIK
Time & Frequency Components
SF-915
SIP5L
16.0max
9.5max
5.0
4.0
16.0max
4-2.54
12.0
#1 #2 #3 #4 #5
00.5
2.75
4.0
Unit:mm
T-4
#1 #2 #3 #4 #5
5.5max
4.0
0.3
15.6max
4-2.54
4.5
0.54
Unit:mm
#1 #2 #3 #4
00.65
1.6
7.6
1.6
S-6BA
16.0max
2.5
3.5
3.5max
6.0
Unit:mm
#1 #2 #3 #4 #5
00.5
4-2.54
1.7
Unit:mm
PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering
Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97
http://www.petermann-technik.de | [email protected]
PETERMANN
TECHNIK
Time & Frequency Components
3 x 3 mm SMD
TO-8
0.85+0.08
-
3.0 +- 0.13
5.0
6.0
3.0 +- 0.13
015.6max
1.5max
5-00.5
0.6
#6
#5
#3
#4
CONNECTION
GROUND
INPUT
GROUND
GROUND
OUTPUT
GROUND
1.40
Unit: mm
6.25
#1
#2
1.40
0.6
3.75 3.75
PIN
#1
#2
#3
#4
#5
#6
TO-5
Unit:mm
5.0
DIP10K
12.7
11.5
4.0
5.2
18.5max
0.50
0.4
4-2.54
1
Unit:mm
2
3
4
5
10 9
8
7
6
PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering
Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97
http://www.petermann-technik.de | [email protected]
Unit: mm
PETERMANN
TECHNIK
Time & Frequency Components
7 x 5 mm SMD
7.0+0.2
-
5.0+0.2
-
0.9+0.09
-
1.5max
1.2+0.15
-
0.23
2.54+0.13
-
0.6
#1
#2
#2
#6
#3
#4
1.0+0.13
-
PIN
#1
#2
#3
#4
#5
#6
CONNECTION
GROUND
INPUT
OUTPUT
GROUND
SIGNAL
GROUND
Unit: mm
PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering
Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97
http://www.petermann-technik.de | [email protected]
Similar pages