JZC-36F
NHG RELAYS
JZC-36F
Operation condition
Insulation Resistance
1000M
Dielectric Strength
Between contacts
Between contact and coil
US
R158859
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
Features
Heavy load, suitable for heavy power reverse.
Small size, suitable for high-density mounting..
Suitable for remote control TV set, copy machine, sales machine and air conditioner etc.
Item 6 of IEC255-5
Item 6 of IEC255-5
Item 8 of IEC255-5
Functional 200m/s2 11ms
Survival 1000m/s2 11ms
10~55Hz amplitude 1.5mm
10N
235
2
3 0.5s
-40~70
35%~85% (at 40 )
12g
Shock resistance
Patent NO.:200420081938.2
24.5 10.5 25.0
Item 7 of IEC255-5
50Hz 1000V
50Hz 3000V 4000V
Surge Voltage 10kV
R
C
min (at 500VDC)
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table
Ordering Information
4
5
6
1 Part number JZC-36F
2 Contact arrangement A:1A C:1C
3 Enclosure S:Sealed type Z:Dust cover
4 Contact current:10A
5 Coil rated voltage(V):DC:5,6,9,12,18,24,48
6 Coil power consumption:0.25:0.25W;0.53:0.53W
Dimensions
Contact Data
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operational
Electrical
Life
Mechanical
1A (SPSTNO) 1C (SPDT(B-M))
AgSnO2
10A/250VAC,30VDC
TV-5
330W 2500VA
30VDC 277VAC
100m
105
10 7
mm /inch
3.5
0.138
10.5max.
0.413max.
24.5max.
1max.
16.5
0.650
0.5
0.020
Contact Arrangement
Contact Material AgCdO
Contact Rating (resistive)
UL & CUR
10A/250VAC,30VDC;TV-5
Max. Switching Current:10A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
2
0.079
0.8
0.031
Coil Parameter
7. 5
0.295
3
Safety approval
Load
DC12V 0.25
7. 5
0.295
2
10
25max.
0.984max.
1
S
4 0.3
0.157 0.012
JZC-36F C
of IEC255-19-1 and minimum sample size 24.
Safety approvals
0.5
0.020
0.5
0.020
Coil voltage
VDC
Coil
resistance
10%
Pick up
voltage
VDC (max)
(75% of rated
voltage )
Release
voltage
VDC (min)
(5% of rated
voltage)
Coil power
consumption
W
Rated
Max
005-250
006-250
009-250
012-250
018-250
024-250
048-250
5
6
9
12
18
24
48
6.5
7.8
11.7
15.6
23.4
31.2
62.4
100
145
325
575
1300
2310
9210
3.75
4.50
6.75
9.00
13.5
18.0
36.0
0.25
0.30
0.45
0.60
0.90
1.2
2.4
0.25
005-530
006-530
009-530
012-530
018-530
024-530
048-530
5
6
9
12
18
24
48
6.5
7.8
11.7
15.6
23.4
31.2
62.4
47
68
155
270
620
1080
4400
3.75
4.50
6.75
9.00
13.5
18.0
36.0
0.25
0.30
0.45
0.60
0.90
1.2
2.4
0.53
Operate
Time
ms
1A
16.5
0.650
3.5
0.138
5- 1.3
0.051
3.5
0.138
1C
Dimensions
Dash
numbers
4- 1.3
0.051
Mounting (Bottom view)
Release
Time
ms
1A
1C
Wiring diagram
(Bottom view)
15
5
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
Reference Data
15
5
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Tolerance:
0.1/ 0.004
Ningbo Forward Relay Corporation LTD.
66
JZC-36F
JZC-36F
Operation condition
Insulation Resistance
1000M
Dielectric Strength
Between contacts
Between contact and coil
US
R158859
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
Features
Heavy load, suitable for heavy power reverse.
Small size, suitable for high-density mounting..
Suitable for remote control TV set, copy machine, sales machine and air conditioner etc.
Item 6 of IEC255-5
Item 6 of IEC255-5
Item 8 of IEC255-5
Functional 200m/s2 11ms
Survival 1000m/s2 11ms
10~55Hz amplitude 1.5mm
10N
235
2
3 0.5s
-40~70
35%~85% (at 40 )
12g
Shock resistance
Patent NO.:200420081938.2
24.5 10.5 25.0
Item 7 of IEC255-5
50Hz 1000V
50Hz 3000V 4000V
Surge Voltage 10kV
R
C
min (at 500VDC)
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table
Ordering Information
4
5
6
1 Part number JZC-36F
2 Contact arrangement A:1A C:1C
3 Enclosure S:Sealed type Z:Dust cover
4 Contact current:10A
5 Coil rated voltage(V):DC:5,6,9,12,18,24,48
6 Coil power consumption:0.25:0.25W;0.53:0.53W
Dimensions
Contact Data
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operational
Electrical
Life
Mechanical
1A (SPSTNO) 1C (SPDT(B-M))
AgSnO2
10A/250VAC,30VDC
TV-5
330W 2500VA
30VDC 277VAC
100m
105
10 7
mm /inch
3.5
0.138
10.5max.
0.413max.
24.5max.
1max.
16.5
0.650
0.5
0.020
Contact Arrangement
Contact Material AgCdO
Contact Rating (resistive)
UL & CUR
10A/250VAC,30VDC;TV-5
Max. Switching Current:10A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
2
0.079
0.8
0.031
Coil Parameter
7. 5
0.295
3
Safety approval
Load
DC12V 0.25
7. 5
0.295
2
10
25max.
0.984max.
1
S
4 0.3
0.157 0.012
JZC-36F C
of IEC255-19-1 and minimum sample size 24.
Safety approvals
0.5
0.020
0.5
0.020
Coil voltage
VDC
Coil
resistance
10%
Pick up
voltage
VDC (max)
(75% of rated
voltage )
Release
voltage
VDC (min)
(5% of rated
voltage)
Coil power
consumption
W
Rated
Max
005-250
006-250
009-250
012-250
018-250
024-250
048-250
5
6
9
12
18
24
48
6.5
7.8
11.7
15.6
23.4
31.2
62.4
100
145
325
575
1300
2310
9210
3.75
4.50
6.75
9.00
13.5
18.0
36.0
0.25
0.30
0.45
0.60
0.90
1.2
2.4
0.25
005-530
006-530
009-530
012-530
018-530
024-530
048-530
5
6
9
12
18
24
48
6.5
7.8
11.7
15.6
23.4
31.2
62.4
47
68
155
270
620
1080
4400
3.75
4.50
6.75
9.00
13.5
18.0
36.0
0.25
0.30
0.45
0.60
0.90
1.2
2.4
0.53
Operate
Time
ms
1A
16.5
0.650
3.5
0.138
5- 1.3
0.051
3.5
0.138
1C
Dimensions
Dash
numbers
4- 1.3
0.051
Mounting (Bottom view)
Release
Time
ms
1A
1C
Wiring diagram
(Bottom view)
15
5
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
Reference Data
15
5
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
65
Tolerance:
0.1/ 0.004
Ningbo Huaguan Relay Corporation LTD.