MPD B1013ERW Low cost 1 x 2 inch 10w wide input range dc/dc converter Datasheet

B1000ERW Series
Low Cost 1 x 2 Inch 10W
Wide Input Range
DC/DC Converters
Key Features:
• 10W Output Power
• 2:1 Input Voltage Range
• 1,500 VDC Isolation
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
• Efficiency to 86%
• Compact 1 x 2 Inch Case
• Single & Dual Outputs
• Industry Standard Pin-Out
• Lowest Cost!!
RoHS Compliant
A
Budget
Saver!!
Input Filter
Short Circuit Input Power
Conditions
Min.
12 VDC Input
9.0
24 VDC Input 18.0
48 VDC Input 36.0
π (Pi) Filter
Typ.
12.0
24.0
48.0
Max.
18.0
36.0
72.0
1,500
Units
VDC
mW
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Positive Load Regulation
Negative Load Regulation
Ripple
Noise
Output Power Protection
Transient Recovery Time (Note 1)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 25% to 100%
Iout = 25% to 100%
Bandwidth = 20 Hz to 300 kHz
Bandwidth = DC to 20 MHz
Typ.
±0.1
0.2
3.0
30
Max.
±3.0
±5.0
±0.2
0.5
5.0
50
100
110
25% Load Step Change
Units
%
%
%
%
%
mV P - P
mV P - P
%
µSec
%
%/°C
200
±2.0
±0.01
±0.02
Typ.
Max.
Units
VDC
MΩ
pF
kHz
Max.
+71
+90
+125
Units
°C
°C
°C
95
%
Continuous
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,500
1,000
130
300
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min.
Typ.
-40
+25
-40
+25
-40
Free Air Convection
RH, Non-condensing
Ambient
Case
Physical
Case Size
Case Material
Weight
2.0 x 1.0 x 0.40 Inches (50.8 x 25.4 x 10.2 mm)
Non-Conductive Black Plastic (UL94-V0)
1.06 Oz (30g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.0
Typ.
Max.
Units
MHours
Conditions
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
All Models
Min.
-0.7
-0.7
-0.7
Typ.
Max.
25.0
45.0
100.0
300
5,000
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
VDC
°C
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
B1001ERW
B1002ERW
B1003ERW
B1004ERW
B1005ERW
B1006ERW
B1011ERW
B1012ERW
B1013ERW
B1014ERW
B1015ERW
B1016ERW
B1021ERW
B1022ERW
B1023ERW
B1024ERW
B1025ERW
B1026ERW
Input
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load
12
9.0 - 18.0
1,111
25
12
9.0 - 18.0
1,068
25
12
9.0 - 18.0
1,041
25
12
9.0 - 18.0
1,157
25
12
9.0 - 18.0
1,082
25
12
9.0 - 18.0
1,041
25
24
18.0 - 36.0
555
8
24
18.0 - 36.0
534
8
24
18.0 - 36.0
520
8
24
18.0 - 36.0
563
8
24
18.0 - 36.0
508
8
24
18.0 - 36.0
496
8
48
36.0 - 75.0
257
5
48
36.0 - 75.0
242
5
48
36.0 - 75.0
242
5
48
36.0 - 75.0
264
5
48
36.0 - 75.0
245
5
48
36.0 - 75.0
245
5
Voltage
(VDC)
5
12
15
±5
±12
±15
5
12
15
±5
±12
±15
5
12
15
±5
±12
±15
Notes:
1. Transient recovery is measured to within a 1% error band for a load
step change of 75% to 100%.
2. Output load regulation is specified for a load change of 25% to
100%.
3. When measuring output ripple, it is recommended that an external
ceramic capacitor (approx approx 1 µF to 10 µF) be placed from the
+Vout pin to the -Vout pin for single output units and from each output
to common for dual output units.
4. These units should not be operated with a load under 10% of full load.
Operation at no-load may cause damage to the unit.
5. These converters are specified for operation without external components. However, in some applications the addition of input/ouput
capacitors will enhance stability and reduce output ripple. Recommended capacitor values are:
Vin
Input
Capacitor
Output
Capacitor
12 VDC
24 VDC
48 VDC
100 µF
100 µF
100 µF
100 µF per 1A of Iout
100 µF per 1A of Iout
100 µF per 1A of Iout
For applications requiring very low output noise levels, a simple LC
filter should be effective.
6. Dual output units may be connected to provide a 10V, 24V or 30 VDC
output. To do this, connect the load across the positive (+Vout) and
negative (-Vout) outputs and float the output common.
7. It is recommended that a fuse be used on the input of a power supply
for protection. See the Model Selection table above for the correct
rating.
Capacitive
Load
Single Output
(µF Max)
400
Dual Output
(µF Max)
Output
Current
(mA, Max)
2,000
832
660
±1,000
±416
±333
2,000
832
660
±1,000
±416
±333
2,000
830
670
±1,000
±416
±333
Current
(mA, Min)
200
83
66
±100
±41
±33
200
83
66
±100
±41
±33
200
83
66
±100
±41
±33
Efficiency
(%, Typ)
75
78
80
72
77
80
75
78
80
74
82
84
81
86
86
79
85
85
Fuse Rating
Slow-Blow
(mA)
3,000
3,000
3,000
3,000
3,000
3,000
1,500
1,500
1,500
1,500
1,500
1,500
750
750
750
750
750
750
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
1
2
3
4
5
+Vin
-Vin
+Vout
No Pin
-Vout
+Vin
-Vin
+Vout
Common
-Vout
±200
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]