PCA EPC3094-3 Off-line pc mount transformer Datasheet

Off-Line PC Mount Transformer
EPC3094-X
ELECTRONICS INC.
• Single Primary : 115 V
• Split Bobbin Construction
• UL 94V-0 Recognized Components
• UL 1446 Class B Insulation System
• Meets or exceeds CSA/TUV/VDE Specifications
for Creepage, Clearance and Dielectric Strength
Electrical Parameters @ 25° C
Part
Number
Primary
Voltage
EPC3094-1
EPC3094-2
EPC3094-3
EPC3094-4
EPC3094-5
EPC3094-6
EPC3094-7
EPC3094-8
EPC3094-9
EPC3094-10
115
115
115
115
115
115
115
115
115
115
Secondary Voltage
Parallel
Series
Connection
Connection
Secondary Current (A-Rms)
Parallel
Series
Connection
Connection
Power
Rating
(VA)
3.60
2.85
2.25
1.80
1.50
1.30
1.00
0.75
0.65
0.30
7.20
10
5.0
5.70
12.6
6.3
4.50
16
8.0
3.60
20
10
3.00
24
12
2.60
28
14
2.00
36
18
1.50
48
24
1.30
56
28
0.60
120
60
• Switching Frequency : 50 Hz - 500 Hz • Isolation : 2500 Vrms •
Package
36
36
36
36
36
36
36
36
36
36
Schematic
2.620
(66.70)
2.180
(55.50)
1.560
(39.70)
Pri.
Sec.
5
4
6
1
7
8
.280
(7.11)
.400
(10.20)
1.850
(47.00)
.041(1.04)
.400
(10.20)
1.200
(30.48)
1
4
Notes :
1. Optional Mounting Screws and Nut : Size #6 Screw
2. Pins 2 and 3 omitted
5
6
7
8
Clearance
Hole (4)
Unless Otherwise Specified Dimensions are in Inches /mm ± .010 /.25
PCA ELECTRONICS, INC.
16799 SCHOENBORN ST.
NORTH HILLS, CA 91343
Product performance is limited to specified parameters. Data is subject to change without prior notice.
CSC3094-X
Rev. -
7/15/02
TEL: (818) 892-0761
FAX: (818) 894-5791
http://www.pca.com