XP Power ISH0503A Dc-dc converter Datasheet

ISH Series
DC-DC Converter
2 Watts
xxx Series
• Single Output
• SMD Package
• Industry Standard Pinout
• Operating Temperature 40 °C to +105 °C
• 1500 VDC Isolation, 3000 VDC Option
• 3 Year Warranty
Dimensions:
ISH:
0.500 x 0.44 x 0.285” (12.7 x 11.2 x 7.25 mm)
Models & Ratings
Input Voltage
4.5-5.5
10.8-13.2
13.5-16.5
21.6-26.4
Output Voltage
Output
Current
3.3V
5V
9V
12V
15V
5V
9V
12V
15V
24V
15V
5V
12V
15V
24V
400 mA
400 mA
222 mA
167 mA
133 mA
400 mA
222 mA
167 mA
133 mA
83 mA
133 mA
400 mA
167 mA
133 mA
83 mA
Input Current(2)
No Load
Full Load
30
30
30
30
30
25
25
25
25
25
18
15
15
15
15
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
506
506
506
506
506
212
212
212
212
212
169
105
105
105
105
Maximum Capacitive
Load
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
Efficiency(3)
Model Number(1)
72%
79%
82%
82%
83%
79%
82%
82%
83%
84%
83%
79%
82%
83%
86%
ISH0503A
ISH0505A
ISH0509A
ISH0512A
ISH0515A
ISH1205A
ISH1209A
ISH1212A
ISH1215A
ISH1224A
ISH1515A
ISH2405A
ISH2412A
ISH2415A
ISH2424A
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
Notes
1. For optional 3000 VDC isolation add suffix ‘-H’ to end of part number e.g. ISH1224A-H.
2. Input currents measured at nominal input voltage.
3. Typical value at full load.
Mechanical Details
0.500±0.020
(12.70±0.5)
Recommended Footprint
Top View grid: 0.1 x 0.1 in (2.54 x 2.54 mm)
Top View
0.276
(7.00)
0.285
(7.25)
PIN CONNECTIONS
0.327
(8.30)
0.441±0.012
(11.20±0.30)
0.300 (7.62)
8
Side View
1
0.100 0.010
(2.54) (0.25)
0.024
(0.60)
0.039
(1.00)
5
2
4
0.100
(2.54)
A
1
0.010
(0.25)
Function
1
GND
2
+Vin
4
0V
5
+Vout
8
No Connection
Notes
A
0.035
(0.88)
0.480
(12.20)
Pin
5 .00 º
www.xppower.com
1. All dimensions are in inches (mm)
2. Weight: 0.003 lbs (1.5 g) typical.
3. Pin diameter: 0.02 ±0.002 (0.5 ±0.005)
4. Pin pitch and length tolerance: ±0.014 (±0.35)
5. Case tolerance: ±0.02 (±0.5)
ISH Series
DC-DC Converter
Input
Characteristic
Input Voltage Range
Minimum
Maximum
Units
Notes & Conditions
4.50
Typical
5.50
VDC
5 V nominal
10.80
13.20
VDC
12 V nominal
13.50
16.50
VDC
15 V nominal
21.60
26.40
VDC
24 V nominal
Input Current
See Models and Ratings table
Input Reflected Ripple
15
mA pk-pk
Input Surge
Input Filter
Through 12 µH inductor and 47 µF capacitor
9
VDC for 1 s
5 V models
18
VDC for 1 s
12 V models
21
VDC for 1 s
15 V models
30
VDC for 1 s
24 V models
Maximum
Units
Notes & Conditions
24
VDC
See Models and Ratings table
-7.5, +2.5
%
Capacitor
Output
Characteristic
Minimum
Output Voltage
3.3
Typical
Initial Set Accuracy
Minimum Load
10
Line Regulation
±1.2
Load Regulation
Start Up Delay
Ripple and Noise
At 70% load
%
%
Per 1% change of input voltage (±1.5% for 3V3 output)
%
See graph
2
ms
100
mV pk-pk
Transient Response
3
% deviation
20 MHz bandwidth, measured using 0.1 µF capacitor
Recovery to within 1% in 500 µs for a 25% load change (5%
max. deviation for 3.3 & 5 V models)
Continuous, with auto recovery, except 1 s max for
24 input V models
Short Circuit Protection
Maximum Capacitive Load
220
µF
Temperature Coefficient
0.03
%/˚C
Maximum
General
Characteristic
Units
Notes & Conditions
Efficiency
Minimum
Typical
See Models and Ratings table
Isolation: Input to Output
VDC
For optional high isolation versions, 3000 VDC input to
output add suffix -H to model number
1500
Switching Frequency
50
Isolation Resistance
109
Isolation Capacitance
kHz
Input to output, tested at 500 VDC
31.8
pF
Win3
kHrs
MIL-HDBK-217F, +25 °C GB
20
Power Density
Mean Time Between Failure
300
3500
Weight
0.003 (1.5)
Ω
Input to output
lb (g)
Environmental
Characteristic
Minimum
Operating Temperature
-40
Storage Temperature
-55
Typical
Maximum
Units
+105
°C
+125
°C
Case Temperature
+115
°C
Operating Humidity
95
% RH
Cooling
Notes & Conditions
Derate from 100% load at +100 °C to 80% load at 105 °C
Non-condensing
Natural convection
www.xppower.com
2
ISH Series
DC-DC Converter
EMC: Emissions
Phenomenon
Standard
Test Level
Conducted
EN55022
Class B
Notes & Conditions
See Application Note for Class B filter
Radiated
EN55022
Class B
See Application Note for Class B filter
Phenomenon
Standard
Test Level
Criteria
ESD Immunity
EN61000-4-2
3
B
EMC: Immunity
Notes & Conditions
Radiated Immunity
EN61000-4-3
3 V/m
A
EFT/Burst
EN61000-4-4
2
B
External input capacitor required, 330 µF/100 V
Surge
EN61000-4-5
2
B
External input capacitor required, 330 µF/100 V
Conducted Immunity
EN61000-4-6
3 V rms
A
Magnetic Fields
EN61000-4-8
1 A/m
A
Load Regulation
110
105
Typical Lo
ad Curve
Output Voltage Accuracy (%)
Output Voltage Accuracy (%)
115
+2.5%
100
-2.5%
-7.5%
0
50
70
100
105
Typical Lo
ad Curve
+2.5%
100
-2.5%
-7.5%
0
Load (%)
For 3.3 V output models
50
70
100
Load (%)
For all other models
Application Note
EMI Filter for Class B Emissions
6.8 µH
+ Vin
4.7 µF,
50 V
4.7 µF,
50 V
+
Vout
ISH
-Vin
C
Load
0V
Output Voltage
C
3.3
10.00 µF
5
10.00 µF
9
4.70 µF
12
2.20 µF
15
1.00 µF
24
0.47 µF
For ISH2424A model only, add Ycap, 470 µF, 3 kv
3
www.xppower.com
04 Dec 14
Similar pages