ILPA60JU SERIES 60W Water-Proof Constant Current LED Driver – – – – – – – 2 Year Warranty Wide Input Voltage 90 to 305VAC, 47 to 63Hz Constant Output Current Available From 350mA To 5000mA Over Voltage, Short Circuit, Lighting, and Over Temperature Protection High Efficiency (up to 91%) Active Power Factor Correction (PFC) (99% typical) IP67 Waterproof Rating, Metal Housing Comply with UL8750 & EN61347 Safety Regulation Approvals: Single Output Part Number ILPA60JU-S500ST ILPA60JU-S330ST ILPA60JU-S230ST ILPA60JU-S170ST ILPA60JU-S140ST ILPA60JU-S105ST ILPA60JU-S070ST ILPA60JU-S045ST ILPA60JU-S035ST Output Current Range (Min. / Typ. / Max.) 4750 / 5000 / 5250mA 3135 / 3300 / 3465mA 2185 / 2300 / 2415mA 1615 / 1700 / 1785mA 1330 / 1400 / 1470mA 1000 / 1050 / 1100mA 665 / 700 / 735mA 428 / 450 / 472mA 332 / 350 / 368mA Output Voltage (Min. / Max.) 6 / 12 VDC 9 / 18 VDC 13 / 27 VDC 18 / 36 VDC 21 / 43 VDC 29 / 58 VDC 43 / 86 VDC 67 / 134 VDC 85 / 170 VDC Efficiency (220VAC, Full Load) 87% 88% 89% 90% 90% 90% 91% 91% 91% Over Voltage Protection (Typ/Max) 15 / 17VDC 23 / 25VDC 35 / 38VDC 42 / 45VDC 50 / 55VDC 65 / 70VDC 92 / 102VDC 145 / 160VDC 195 / 215VDC Max. Output Power 60W 60W 60W 60W 60W 60W 60W 60W 60W Electrical Characteristics Parameter Input Voltage Input Frequency Output Power Range Input Current (Low Line) Input Current (High Line) High Line Inrush Current Power Factor Correction Efficiency Line Regulation Load Regulation Over Voltage Protection Over Temperature Protection Short Circuit Protection Output Overshoot / Undershoot Start Up Time Ripple & Noise (Peak to Peak) Test Conditions Operating Voltage Min. 90 47 0 Typ. Max. Unit 305 VAC 63 Hz Vin=90 to 305VAC 60 W Io=Full load, Vin=115VAC 0.80 A Io=Full load, Vin=230VAC 0.36 A Io=Full load, 25°C, Cool start, Vin=230VAC 50 A Vin=110VAC 95 99 % Io=Full Load, Vin=220VAC 87 91 % Io=Full Load 1 % Vin=230VAC 3 % Latch mode. The power unit shall return to normal operation only after the power is turn-on again. (Please refer to output table.) 110 °C No damage shall occur when any output operating in a short circuit condition. The power supply shall be self-recovery when the fault condition is removed. When power on or off 10 % Io=Full Load, Vin=100VAC 0.6 S Measured by 20 MHz bandwidth oscilloscope and the output paralleled a 0.1 uF ceramic capacitor and a 10 uF electrolytic capacitor. 5 % Vo Max. 70 85 Unit °C °C Hours Hours Conditions Parameter Test Conditions Operating Temperature Humidity: 10% RH to 100% RH Storage Temperature Humidity: 5% RH to 100% RH MTBF: Operation temperature at 25°C, calculated per MIL-HDBK-217F Life Time at 25°C ambient temperature Min. -35 -40 0.546M 0.080M Typ. Approvals and Compliance Parameter EMI EMS Safety UL/c-UL, CE Waterproof Standards EN55015 EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, , EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547 UL8750 Compliant to UL1310 ClaST 2, UL1012, UL935, CSA-C22.2 No. 0, CSA-C22.2 No. 107.1, CSA-C22.2 No.250.0, EN61347-1,EN61347-2-13 IP67 Rating Mechanical Parameter Dimension, Net Weight Specification 150x67.5x37mm (5.91x2.66x1.46 inches) 750g approx.