AIMTEC AMEL5-5DEMAZ 5 watt | ac-dc / dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AMEL5-MAZ
5 Watt | AC-DC / DC-DC Converter
FEATURES:




I/O Isolation 4000VAC
Operating Temp: -40 oC to +80 oC or -25 oC to +80 oC
Input: 90-264VAC, 47-440Hz, or 130-370VDC
Over load, Over Voltage, Short Circuit Protection




RoHS compliant
Energy Star compliant
Ultra small package
Soft start
Models
Single output
Model
CB
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
(ºC)
Output
Voltage
(V)
Output
Current max
(A)
Efficiency
(%)
Maximum
capacitive
Load
(µF)
AMEL5-3.3SMAZ
90-264/47-440
130-370
-25 to +80
3.3
1. 5
2200
AMEL5-5SMAZ
90-264/47-440
130-370
-25 to +80
5
1
1100
AMEL5-12SMAZ
90-264/47-440
130-370
-25 to +80
12
0.42
680
AMEL5-15SMAZ
90-264/47-440
130-370
-25 to +80
15
0.333
330
AMEL5-24SMAZ
90-264/47-440
130-370
-25 to +80
24
0.21
220
AMEL5-3.3SEMAZ
90-264/47-440
130-370
-40 to +80
3.3
1. 5
2200
AMEL5-5SEMAZ
90-264/47-440
130-370
-40 to +80
5
1
1100
AMEL5-12SEMAZ
90-264/47-440
130-370
-40 to +80
12
0.42
680
AMEL5-15SEMAZ
90-264/47-440
130-370
-40 to +80
15
0.333
330
AMEL5-24SEMAZ
90-264/47-440
130-370
-40 to +80
24
0.21
220
Note: Optional mounting plate version can be ordered by adding “-ST” suffix to part number (ex. AMEL5-5SMAZ-ST)
115
VAC
230
VAC
71
74
77
77
76
69
70
74
74
76
70
71
75
74
75
68
71
73
73
75
Models
Dual output
Model
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
(ºC)
Output
Voltage
(V)
Output
Current max
(A)
Efficiency
(%)
Maximum
capacitive
load
(µF)
AMEL5-5DMAZ
90-264/47-440
130-370
-25 to +80
±5
±0.5
±470
AMEL5-12DMAZ
90-264/47-440
130-370
-25 to +80
±12
±0.21
±220
AMEL5-15DMAZ
90-264/47-440
130-370
-25 to +80
±15
±0.168
±150
AMEL5-5DEMAZ
90-264/47-440
130-370
-40 to +80
±5
±0.5
±470
AMEL5-12DEMAZ
90-264/47-440
130-370
-40 to +80
±12
±0.21
±220
AMEL5-15DEMAZ
90-264/47-440
130-370
-40 to +80
±15
±0.168
±150
Note: Optional mounting plate version can be ordered by adding “-ST” suffix to part number (ex. AMEL5-5SMAZ-ST)
115
VAC
230
VAC
72
73
72
72
73
72
72
73
73
72
73
73
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input Dissipation (No Load)
Start up time
Under Voltage Protection
www.aimtec.com
F 052e R8.R
Conditions
Typical
115 VAC
230 VAC
115 VAC
230 VAC





1.5
൑ 0.1
780
85
Recommended slow blow type
No load (110/230VAC)
Soft Start
Tel: +1 514 620 2722
1 of 5
Maximum
120
70
15
30
0.2
Units
mA
mA
A
A
mA
A
W
mS
VAC
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-MAZ
5 Watt | AC-DC / DC-DC Converter
Output Specifications
Parameters
Conditions
Typical
Maximum
Voltage accuracy
Line regulation
Load regulation (single output)
Cross Regulation (dual output)
Transient Recovery Time
Transient Response Deviation
Minimum load
±2
±1
0-100% load
±1
25% load – 1st out, 100% load – 2nd out
±5
300
25% load step
±2
0
3.3 / 5V models
75
Ripple & Noise *
12 / 15V models
100
24V
150
Hold-up time (minimum)
15
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1µF (M/C) and 47µF (E/C) parallel capacitor.
Units
%
%
%
%
µs
% of Vout
%
mV p-p
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
Typical
60 sec
4000
>1000
Conditions
Typical
Rated
Units
VAC
MΩ
General Specifications
Parameters
Switching frequency
Protection class
Over Load protection
Over voltage protection
Short circuit protection
Operating temperature
Storage temperature
Maximum Case temperature
Temperature coefficient
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
With derating above 50ºC
Maximum
132
Class II
Fold back
Zener diode clamp
Auto recovery
Refer to the models table above
-40 to +95
100
0.02
Units
KHz
oC
oC
oC
% / oC
Free air convection
Non condensing
20 ~ 95
% RH
Plastic (flammability to UL 94V-0)
30
g
2.03 x 1.10 x 0.70 inches 51.5 x 28 x 17.8mm
> 400,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
MTBF
> 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Parameters
Shock
Vibrations
Conditions
Wave form: Half sine wave
Acceleration amplitude: 5gn
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
www.aimtec.com
F 052e R8.R
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-MAZ
5 Watt | AC-DC / DC-DC Converter
Safety Specifications
Parameters
Agency approvals
Standards
cULus, CE, CB
Medical Electrical Equipment
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No. 601.1-M90
EN 60950-1:2006+A11:2009
EN55011, class B
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 2
IEC 61000-4-4 Level 3
IEC 61000-4-5 Level 3
IEC 61000-4-6 Level 2
IEC 61000-4-8 Level 2
IEC 61000-4-11
Additional Surge Protective Circuitry
The AMEL5-MAZ series design level surge protection is certified to IEC 61000-4-5 surge Line to Line of 1KV. However
greater protection can be enhanced by adding protective devices to ingress circuitry. For example, by adding an MOV (Metal
Oxide Varistor) device example TVR10471KSY to the N / L input lines 2KV surge protection or greater, can be achieved.
MOV PN
Vrms
V
Vdc
V
Wmax (2ms)
J
Pmax
W
TVR10471KSY
300
385
70
0.4
Dimensions
2.03
(51.50)
1.80
(45.72)
1
Case Temperature
Measurement point
3
0.40
(10.16)
1.10
0.80
(28.00) (20.32)
TOP VIEW
1
TOP VIEW
4
+
0.40
(10.16)
2
5
2
3
4
5
0.11
(2.89)
17.80
(0.70)
5 Ø- 0.047 (Ø 1.2)
Ø 0.04
(1.00)
0.2
(5.08)
(Min)
www.aimtec.com
F 052e R8.R
DIV: 0.2 (5.08)
Dimensions: inch (mm)
Case Tolerance:± 0.012 (0.30)
Pin Pitch Tolerance: ± 0.012 (0.30)
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-MAZ
5 Watt | AC-DC / DC-DC Converter
Pin Out Specifications
Pin
Single
Dual
1
2
3
4
5
AC Input (N)
AC Input (L)
+V Output
-V Output
No pin
AC Input (N)
AC Input (L)
+V Output
Common
-V Output
Derating
www.aimtec.com
F 052e R8.R
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-MAZ
5 Watt | AC-DC / DC-DC Converter
Dimensions of Optional ST Mounting Plate Version
Pin Out Specification ST Version
86.00
38.00
25.00
70.00
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.R
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only