Ordering information AC-DC Power Supplies Power Module type DPG DPG 750 1 2 1Series name 2Output power 500 : 500W (ACIN 200V) 750 : 750W (ACIN 200V) DPG MODEL DPG500 AC INPUT[V] AC85 - 264 AC170 - 264 AC85 - 264 AC170 - 264 500 500 750 MAX OUTPUT WATTAGE[W] *1 300 DC OUTPUT VOLTAGE[V] *2 360 DPG750 SPECIFICATIONS MODEL DPG500 VOLTAGE[V] AC85 - 264 1f DPG750 AC170 - 264 1f AC85 - 264 1f AC170 - 264 1f 2.86typ (ACIN 200V) 5.72typ (ACIN 100V) 4.24typ (ACIN 200V) POWER FACTOR CORRECTION RANGE[V] AC85 - 264 1f INPUT CURRENT[A] 3.47typ (ACIN 100V) FREQUENCY[Hz] 50/60 (47 - 63) Hz INRUSH CURRENT[A] Limited by external resistance EFFICIENCY[%] 92typ (ACIN 100V) 95typ (ACIN 200V) 93typ (ACIN 100V) 96typ (ACIN 200V) POWER FACTOR 0.96typ (ACIN 100V) 0.93typ (ACIN 200V) 0.96typ (ACIN 100V) 0.93typ (ACIN 200V) 500 750 LEAKAGE CURRENT[mA] OUTPUT 0.75 max (60Hz, According to IEC60950 and DEN-AN) WATTAGE[W] *1 300 VOLTAGE[V] *2 360 VOLTAGE ACCURACY *3 ±2% 500 PROTECTION OVERVOLTAGE PROTECTION[V] DC400 - 450V The power factor corrector function stops *4 Enable signal, Open-drain output, Maximum sink current 10mA, Maximum allowance voltage 35V CIRCUIT AND ENA OTHERS *5 Parallel operation impossible , Thermal protection OTHERS ISOLATION INPUT-OUTPUT Non isolated INPUT, OUTPUT-FG AC2,800V 1minute Cutoff current = 10mA, DC500V, 50MW min (20±15C) OPERATING TEMP.,HUMID.AND ALTITUDE -40 to +85C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max ENVIRONMENT SAFETY OTHERS *1 *2 *3 *4 *5 *6 STORAGE TEMP.,HUMID.AND ALTITUDE -40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max VIBRATION 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis AGENCY APPROVALS UL60950-1, C-UL, EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1 HARMONIC ATTENUATOR Complies with IEC61000-3-2 *6 CASE SIZE/WEIGHT 58.4X12.7X61mm [2.3X0.5X2.4 inches] (WXHXD) / 100g max COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) Refer to Input voltage derating. When the input voltage is more than 240V, the output voltage becomes the value proportional to the input voltage. The value included the output setting and the line regulation, the load regulation and the temperature regulation. However, the input voltage is less than 240V. Refer to the instruction Manual. The thermal protection stops the power factor corrector function and the ENA signal. Please contact us about class C. DPG-2 DPG500/DPG750 External view Base plate(Aluminum) Recomending size for processing PCB (TOP VIEW) 12.7±0.5 [0.5] 5.0±0.5 [0.2] Lot No. 48.3 [1.9] 4-f3.5 [0.14] 12.7 [0.2] [0.5] 4-M3(FG) Mounting Hole 58.4max [2.3] [0.2] [1.9] 7-f1 DPG 12.7 [0.5] 48.3 ± 0.5 (5.0) 12.7 [0.5] ±0.5 [2] 50.8 [0.5] +VOUT [2.4] AC 12.7 -VOUT [0.5] AC 61max AUX ENA [0.04] 12.7 12.7 [0.5] 50.8 [2.0] 5.08 12.7 [0.5] Case(PBT) 7-f1.5 [0.06] 5.08 [0.2] R ¶ Dimensions in mm, [ ]=inches ¶ Div. : 0.5inch ¶ Tolerance : ±0.3 [±0.012] ¶ Weight : 100g max ¶ Dimensions in mm, [ ]=inches ¶ Mounting hole screwing torque : 0.49N-m (5.0kgf-cm) max [0.2] (5.1) Name Plate 12.7 [0.5] Performance data ¡OUTPUT VOLTAGE FOR INPUT ¡STATIC CHARACTERISTICS (AC230V ) 400 400 DPG750 DPG750 OUTPUT VOLTAGE OUTPUT VOLTAGE V 380 V 380 360 340 320 0 340 320 0 0 0.5 1.0 1.5 OUTPUT CURRENT 2.0 0 2.5 50 100 150 200 INPUT VOLTAGE A ¡HARMONIC CURRENT (AC100V ) 250 300 V ¡HARMONIC CURRENT (AC230V ) 10 10 DPG750 Harmonic current standard of class A (at odd number) A Harmonic current standard of class A (at odd number) A DPG750 1 1 HARMONIC CURRENT HARMONIC CURRENT 360 0.1 0.01 0.1 0.01 0.001 0.001 1 10 20 HARMONIC ORDER 30 40 1 10 20 30 40 HARMONIC ORDER DPG-3