RSG DPG500 Ac-dc power supplies power module type Datasheet

Ordering information
AC-DC Power Supplies Power Module type
DPG
DPG 750
1
2
1Series name
2Output power
500 : 500W (ACIN 200V)
750 : 750W (ACIN 200V)
DPG
MODEL
DPG500
AC INPUT[V]
AC85 - 264
AC170 - 264
AC85 - 264
AC170 - 264
500
500
750
MAX OUTPUT WATTAGE[W]
*1
300
DC OUTPUT VOLTAGE[V]
*2
360
DPG750
SPECIFICATIONS
MODEL
DPG500
VOLTAGE[V]
AC85 - 264 1f
DPG750
AC170 - 264 1f
AC85 - 264 1f
AC170 - 264 1f
2.86typ (ACIN 200V)
5.72typ (ACIN 100V)
4.24typ (ACIN 200V)
POWER FACTOR CORRECTION RANGE[V] AC85 - 264 1f
INPUT
CURRENT[A]
3.47typ (ACIN 100V)
FREQUENCY[Hz]
50/60 (47 - 63) Hz
INRUSH CURRENT[A]
Limited by external resistance
EFFICIENCY[%]
92typ (ACIN 100V)
95typ (ACIN 200V)
93typ (ACIN 100V)
96typ (ACIN 200V)
POWER FACTOR
0.96typ (ACIN 100V)
0.93typ (ACIN 200V)
0.96typ (ACIN 100V)
0.93typ (ACIN 200V)
500
750
LEAKAGE CURRENT[mA]
OUTPUT
0.75 max (60Hz, According to IEC60950 and DEN-AN)
WATTAGE[W]
*1
300
VOLTAGE[V]
*2
360
VOLTAGE ACCURACY
*3
±2%
500
PROTECTION OVERVOLTAGE PROTECTION[V] DC400 - 450V The power factor corrector function stops
*4 Enable signal, Open-drain output, Maximum sink current 10mA, Maximum allowance voltage 35V
CIRCUIT AND ENA
OTHERS
*5 Parallel operation impossible , Thermal protection
OTHERS
ISOLATION
INPUT-OUTPUT
Non isolated
INPUT, OUTPUT-FG
AC2,800V 1minute Cutoff current = 10mA, DC500V, 50MW min (20±15C)
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to +85C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max
ENVIRONMENT
SAFETY
OTHERS
*1
*2
*3
*4
*5
*6
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
VIBRATION
10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
AGENCY APPROVALS
UL60950-1, C-UL, EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1
HARMONIC ATTENUATOR
Complies with IEC61000-3-2 *6
CASE SIZE/WEIGHT
58.4X12.7X61mm [2.3X0.5X2.4 inches] (WXHXD) / 100g max
COOLING METHOD
Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Refer to Input voltage derating.
When the input voltage is more than 240V, the output voltage becomes the value proportional to the input voltage.
The value included the output setting and the line regulation, the load regulation and the temperature regulation.
However, the input voltage is less than 240V.
Refer to the instruction Manual.
The thermal protection stops the power factor corrector function and the ENA signal.
Please contact us about class C.
DPG-2
DPG500/DPG750
External view
Base plate(Aluminum)
Recomending size for processing PCB
(TOP VIEW)
12.7±0.5
[0.5]
5.0±0.5
[0.2]
Lot No.
48.3
[1.9]
4-f3.5
[0.14]
12.7
[0.2]
[0.5]
4-M3(FG)
Mounting Hole
58.4max
[2.3]
[0.2]
[1.9]
7-f1
DPG
12.7
[0.5]
48.3 ± 0.5
(5.0)
12.7
[0.5]
±0.5
[2]
50.8
[0.5]
+VOUT
[2.4]
AC
12.7
-VOUT
[0.5]
AC
61max
AUX ENA
[0.04]
12.7
12.7
[0.5]
50.8
[2.0]
5.08
12.7
[0.5]
Case(PBT)
7-f1.5
[0.06]
5.08
[0.2]
R
¶ Dimensions in mm, [ ]=inches
¶ Div. : 0.5inch
¶ Tolerance : ±0.3 [±0.012]
¶ Weight : 100g max
¶ Dimensions in mm, [ ]=inches
¶ Mounting hole screwing torque : 0.49N-m (5.0kgf-cm) max
[0.2]
(5.1)
Name Plate
12.7
[0.5]
Performance data
¡OUTPUT VOLTAGE FOR INPUT
¡STATIC CHARACTERISTICS (AC230V )
400
400
DPG750
DPG750
OUTPUT VOLTAGE
OUTPUT VOLTAGE
V
380
V
380
360
340
320
0
340
320
0
0
0.5
1.0
1.5
OUTPUT CURRENT
2.0
0
2.5
50
100
150
200
INPUT VOLTAGE
A
¡HARMONIC CURRENT (AC100V )
250
300
V
¡HARMONIC CURRENT (AC230V )
10
10
DPG750
Harmonic current standard
of class A (at odd number)
A
Harmonic current standard
of class A (at odd number)
A
DPG750
1
1
HARMONIC CURRENT
HARMONIC CURRENT
360
0.1
0.01
0.1
0.01
0.001
0.001
1
10
20
HARMONIC ORDER
30
40
1
10
20
30
40
HARMONIC ORDER
DPG-3