Emerson Network Power NLP40-7615J 40-50 w ac/dc universal input switch mode power supply Datasheet

NLP40 Series
Single, dual and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
•
•
•
•
•
•
•
•
40-50 W AC/DC Universal Input Switch Mode Power Supplies
1
4.25 x 2.5 x 1.15 inch package (1U applications)
Smallest industry package
Overvoltage and short circuit protection
40 W with free air convection
EN55022, EN55011 conducted emission level B
EN61000-4-2, -3, -4, -5, -6 immunity compliant
UL, VDE and CSA safety approvals
Available RoHS compliant
The NLP40 series is a 40 W universal input ac-dc power supply on a 4.25 x 2.5 inch card
with a maximum component height of 1.15 inches for use in 1U applications. This product is
the smallest standard 40 W package in the industry making the series ideal for
communication applications with space constraints where a standard 5 x 3 inch card
solution is not suitable. The NLP40 provides 40 W of output power with free air convection
cooling which can be boosted to 50 W with 20 CFM of air. Standard features include
overvoltage and short circuit protection. The series, with full international safety approval and
the CE mark, meets conducted noise EN55022 level B and has immunity compliance to
EN61000-4-2,-3,-4, -5, -6. The NLP40 series is designed for use in low power data
networking, computer and telecom applications such as hubs, routers, POS terminals, LCD
projectors, cable modems and PABX’s. This list is not exclusive as the generic feature set of
the NLP40 series with industry standard output configurations provides a solution for most
low power applications including many industrial applications.
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
OUTPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Total regulation
(Line and load)
Main output
Auxiliary outputs
Rise time
At turn-on
Transient response
Main output
5.0% max. dev.,
25% step at 0.1 A/µs 1 ms rec. to 1.0%
Temperature coefficient
±2.0%
±5.0%
1.0 s, max.
±0.02%/°C
Overvoltage protection
Main outputs
Short circuit protection
Cyclic operation
Minimum output current
Single
Multiple
135%, ±15%
Continuous
0A
(See Note 5)
INPUT SPECIFICATIONS
Input voltage range
(See Note 9)
120 Vac
230 Vac
12 ms @ 40 W
20 ms @ 40 W
Efficiency
75% typical
Isolation voltage
Input/output
Input/chassis
Switching frequency
Fixed
65 kHz, ±5 kHz
Approvals and
standards (See Note 8)
EN60950, IEC950, UL1950
VDE0805, CSA C22.2 No. 950
Weight
MTBF
3000 Vac
1500 Vac
200 g (7.06 oz)
MIL-HDBK-217F
150,000 hours min.
ENVIRONMENTAL SPECIFICATIONS
Universal input
Input frequency range
90-264 Vac
120-370 Vdc
Thermal performance
(See Notes 6, 7, 9)
Operating ambient,
0 °C to +70 °C
(see derating curve)
Non-operating
-40 °C to +70 °C
50 °C to 70 °C ambient,
Derate to
convection cooled
50% load
0 °C to 50 °C, ambient,
40 W
convection cooled
0 °C to 50 °C ambient,
50 W
20 CFM forced air
Peak (0 °C to +50 °C, 60 s) (See Note 2)
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration (See Note 4)
5-500 Hz
Shock
per MIL-STD-810E
47-440 Hz
Input surge current
120 Vac, cold start
230 Vac, cold start
Safety ground
leakage current
120 Vac, 60 Hz
230 Vac, 50 Hz
Input current
120 Vac
230 Vac
Input fuse
UL/IEC127
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
Hold-up time
15 A max.
30 A max.
0.2 mA
0.4 mA
1.4 A rms
0.7 A rms
250 Vac H 3.15 A
(10)
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 3
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Perf.
Perf.
Perf.
Perf.
Perf.
Perf.
level B
level A
criteria 1
criteria 1
criteria 1
criteria 1
criteria 1
criteria 1
5% to 95% RH
10,000 feet max.
30,000 feet max.
2.4 G rms peak
516.4 Part IV
File Name: nlp40.pdf Rev (03): 08 Nov 2005
NLP40 Series
Single, dual and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
40-50 W AC/DC Universal Input Switch Mode Power Supplies
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT CURRENT
OUTPUT
RIPPLE
(1)
PEAK
(2)
FAN
TOTAL
(3)
(1)
MODEL NUMBER
VOLTAGE
MAX
+3.3 V (IA)
4A
5A
4.5 A
50 mV
±2.0%
+12 V (IB)
2A
3A
3A
120 mV
±5.0%
–12 V (IC)
0.2 A
1A
0.5 A
120 mV
±5.0%
+5 V (IA)
4A
5A
4.5 A
50 mV
±2.0%
+12 V (IB)
2A
3A
3A
120 mV
±5.0%
–12 V (IC)
0.2 A
1A
0.5 A
120 mV
±5.0%
+5 V (IA)
4A
5A
4.5 A
50 mV
±2.0%
+15 V (IB)
1.6 A
2A
2A
150 mV
±5.0%
–15 V (IC)
0.2 A
1A
0.5 A
150 mV
±5.0%
+12 V (IA)
1.8 A
2.2 A
2.1 A
120 mV
±2.0%
-12 V (IB)
1.8 A
2.2 A
2.1 A
120 mV
±5.0%
+5 V (IA)
4A
5A
4.5 A
50 mV
±2.0%
+12 V (IB)
2A
3A
3A
120 mV
±5.0%
3.3 V (IA)
8A
10 A
9A
50 mV
±2.0%
NLP40-76S3J
NLP40-76T366J
(5)
NLP40-7610J
(5)
NLP40-7627J
(5)
NLP40-7629J
(5)
5V
8A
10 A
9A
50 mV
±2.0%
NLP40-7605J
3.3 A
4.5 A
4A
120 mV
±2.0%
NLP40-7612J
15 V
2.6 A
3.6 A
3.3 A
150 mV
±2.0%
NLP40-7615J
24 V
1.6 A
2.5 A
2A
240 mV
±2.0%
NLP40-7624J
48 V
0.8 A
1.1 A
1A
300 mV
±2.0%
NLP40-7617J
Notes
(5)
NLP40-7608J
12 V
Maximum output power is 40 W for natural convection cooling. With
20 CFM fan cooling, the maximum output power is 50 W.
2 Peak output current lasting less than 60 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total reg. limits.
3 Figure is peak-to-peak. Output noise measurements are made across a
50 MHz bandwidth using a 12 inch twisted pair, terminated with a 47 µF
capacitor.
4 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G
rms 5 Hz to 500 Hz.
5 For multiple output units (except -7627J, 76T366J) to maintain stated
regulation then:
0.25 ≤ IA / IB ≤ 5, for IB > 0.3 A
0.50 ≤ IA / IB ≤ 5, for IB < 0.3 A
For maximum output current I(C) on triple output models, i.e. for
IC = IMax., I A min. ≥ 0.5 A and IA ≥ IB.
For NLP40-7627J only, to maintain stated regulation then:
0.5 ≤ IA / IB ≤ 2.
For NLP40-76T366J only, to maintain stated regulation then:
0.25 ≤ IA / IB ≤ 4.
6 For optimum reliability, no part of the heatsink should exceed 120 °C, and
no semiconductor case temperature should exceed 130 °C.
7 CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
8 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
9 When the input voltage is <90 Vac the operating range is 0 °C to +40 °C.
10 For system EMI compliance, a ground choke may be required before
connecting the ground wire to the chassis. It is recommended that this
ground choke be placed as close as possible to the systems ac inlet to
eliminate noise pick-up in the system.
11 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
12 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
(11,12)
REGULATION
DERATING CURVE
Output Power (Watts)
1
50W
20 CFM FORCED AIR COOLING
40W
25W
NATURAL
CONVECTION
COOLING
0°C
10°C
20°C
30°C
40°C
20W
50°C
60°C
70°C
File Name: nlp40.pdf Rev (03): 08 Nov 2005
NLP40 Series
Single, dual and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
40-50 W AC/DC Universal Input Switch Mode Power Supplies
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
4.25
(107.95)
0.125
(3.175)
4.00
(101.60)
J1
F1
N
1
L
2.50
(63.50)
J2
2.25
(57.15)
P1
T1
C5
ALL DIMENSIONS IN INCHES (mm)
Mounting
Hole Diameter
0.138 (3.50) Typical
MAXIMUM COMPONENT
HEIGHT 1.15 (29.21)
TOLERANCE: .xxx ± 0.005"
.xx
± 0.02"
Input and output connectors
AC (J1) connector type
Molex 26-60-4030 type.
INPUT
PIN CONNECTIONS
J1
DC (J2) connector type
Molex 26-60-4060 type.
Mating connectors
AC (J1) mating connector type
Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp
terminals.
DC (J2) mating connector type
Molex 09-50-3061 with Triurcon 6838 or equivalent crimp terminals.
Note: The input and output connectors are the same as
those used on NFS40, NFN40, NAL40 and NAN40.
VDE0805/EN60950/IEC950 File 10401-3336-0093
Licence No. 93662
UL1950 File No. E136005
AC Line
Pin 2
No Pin
Pin 3
AC Neutral
Pin 1
Safety Ground
P1
J2
International Safety Standard Approvals
Pin 1
OUTPUT PIN CONNECTIONS
SINGLE
DUAL
TRIPLE
Pin 1
+Vout
V (B)
V (B)
Pin 2
+Vout
V (A)
V (A)
Pin 3
+Vout
V (A)
V (A)
Pin 4
Return
Return
Return
Pin 5
Return
Return
Return
Pin 6
Return
Return
V (C)
CSA C22.2 No. 950 File No. LR41062C
Datasheet © Artesyn Technologies® 2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent
accompany the sale of any such product(s) or information contained herein.
www.artesyn.com
File Name: nlp40.pdf Rev (03): 08 Nov 2005
Similar pages