XP Power CPK1KPS30 Ac-dc chassis mount Datasheet

AC-DC Chassis Mount
600-1000 Watts
THE XPERTS IN POWER
CPK Series
Up to 2 kW Peak Rating
•
•
Wide Output Voltage Adjustment
•
Up to 500 W Convection Cooled
•
Optional Conformal Coating
•
Optional Remote ON/OFF
•
Optional AC, DC & Fan Fail Signals
Specification
Input
Input Voltage
•
Input Frequency
•
Inrush Current
•
Power Factor
•
Earth Leakage Current •
85-264 VAC (120-350 VDC)
47-63 Hz
20/40 A typical at 115/230 VAC
0.98 typical at 230 VAC at 100% load
0.75 mA max at 230 VAC 60Hz
for 0.50 mA add suffix ‘-E’,
for 0.15 mA add suffix ‘-G’
Switching
Frequency
Vertical
Terminal block
Din Rail Mounting
Fan Fitted
•
•
•
•
N+1 Operation
Alarms (Optional)
•
•
Conformal Coating
•
Output
Output Voltage
Output Voltage
Adjustment
Minimum Load
Start Up time
Hold Up time
Initial Set Accuracy
Drift
Line Regulation
Load Regulation
Ripple & Noise
Overvoltage
Protection
Overcurrent
Protection
Remote ON/OFF
(Optional)
•
•
See Table
See Table
•
•
•
•
•
•
•
•
•
No minimum load required
500 ms max at 100 VAC 100% load
20 ms typical at 100 VAC 100% load
±1% max
±0.4%
±0.4% from low line to high line
±0.7% max from 0-100% load
±0.8% max pk-pk 20 MHz bandwidth
115-140% of Vnom, recycle input to
restart
101% of peak current auto recovery
•
•
Add suffix ‘-R’ to model number
ON 4.5-12.5 V (open circuit)
between RC+ and RCOFF 0 to 0.5 V (short circuit)
between RC+ and RC-
General
Efficiency
Isolation
•
•
86-89% dependent on model
3000 VAC Input to Output
2000 VAC Input to Ground
85 kHz ±15% active PFC
130 kHz ±15% forward converter
Add suffix ‘-T’ to model numbers
Add suffix ‘-NI’ to model numbers
Add suffix ‘-F’ to model number
(only available on 24 V units)
Option ‘-W’ & external oring diodes
For AC fail, DC fail and fan fail add
suffix ‘-W’ to model number
Add suffix ‘-L’ to model numbers
Environmental
Operating
Temperature
•
Storage Temperature
Relative Humidity
Shock
Vibration
•
•
•
•
-10 °C to +70 °C (fan cooled)
Derate linearly above +50 °C to 60%
load at +70 °C.
For convection cooled rating - See
Derating Curves
-20 °C to +75 °C
20-90% RH non-condensing
20 G, 11 ms once each, X, Y & Z axis
2 G, 3 min period, 60 min each along
X, Y & Z axis
EMC & Safety
Emissions
•
ESD Susceptibility
Radiated
Susceptibility
EFT/Burst
Surge
•
•
Safety Approvals
•
•
•
EN55022 level B conducted
(level A with option E not available with
option G) EN55022 level B radiated
EN61000-4-2 Level 2 contact Level 3 air
EN61000-4-3 Level 3
EN61000-4-4 Level 4
EN61000-4-5 Level 3 line to line
Level 4 line to ground
UL60950, C-UL (CSA60950),
EN60950, EN50178
•
•
www.xpplc.com
[email protected]
OUTPUT VOLTAGE & CURRENT RATINGS
24.0
30.0
36.0
48.0
24.0
30.0
36.0
48.0
24.0
30.0
36.0
48.0
Output
Voltage
V (21.6-27.0
V (27.0-33.0
V (33.0-41.0
V (41.0-52.8
V (21.6-27.0
V (27.0-33.0
V (33.0-41.0
V (41.0-52.8
V (21.6-27.0
V (27.0-33.0
V (33.0-41.0
V (41.0-52.8
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
Output Current (85-130 VAC IN)
Max
Fan(1)
Peak2)
14.0 A
21.0 A
25.0 A
11.0 A
16.5 A
20.0 A
9.0 A
14.0 A
16.5 A
6.5 A
10.5 A
12.5 A
17.0 A
25.0 A
42.0 A
13.5 A
20.0 A
33.5 A
11.0 A
16.5 A
28.0 A
8.0 A
12.5 A
21.0 A
21.0 A
33.0 A
63.0 A
16.5 A
26.0 A
50.0 A
14.0 A
22.0 A
42.0 A
10.5 A
16.5 A
31.5 A
CPK
Output Current (180-264 VAC IN)
Max
Fan(1)
Peak(2)
15.0 A
25.0 A
31.0 A
12.0 A
20.0 A
24.5 A
10.0 A
16.5 A
20.5 A
7.0 A
12.5 A
15.5 A
19.0 A
31.5 A
63.0 A
15.0 A
24.5 A
50.0 A
12.5 A
20.5 A
42.0 A
9.0 A
15.5 A
31.5 A
25.0 A
42.0 A
83.0 A
20.0 A
33.5 A
66.0 A
16.5 A
28.0 A
55.0 A
11.5 A
21.0 A
41.5 A
Efficiency
(3)
86%
87%
87%
89%
88%
88%
89%
89%
88%
88%
89%
89%
Model
Number
CPK600PS24
CPK600PS30
CPK600PS36
CPK600PS48
CPK750PS24
CPK750PS30
CPK750PS36
CPK750PS48
CPK1KPS24
CPK1KPS30
CPK1KPS36
CPK1KPS48
Notes
•
1. Add suffix ‘-F’ to model number to receive unit with fan fitted (24 V units only) alternatively 60 CFM system airflow must be provided.
2. Peak rating is valid for each model number and is not dependent on whether the max rating is convection or fan cooled.
3. Efficiency is specified at 230 VAC and 100% load.
Mechanical Details 600 Watts
NOTE: ‘-F’ option (24 V models only) increases the overall height from 65 to 96 mm.
Weight 1.5 kg
For pin out tables see 1000 W mechanical details.
Mechanical Details 750 Watts
NOTE: ‘-F’ option (24 V models only) increases the overall height from 70 to 101 mm.
Weight 1.9 kg
For pin out tables see 1000 W mechanical details.
www.xpplc.com
[email protected]
Mechanical Details 1000 Watts
NOTE: ‘-F’ option (24 V models only) increases the overall height from 75 to 106 mm.
Weight 2.5 kg
PIN CONNECTIONS
FUNCTION
Voltage Balance
Current Balance
Output Terminal (+)
Output Terminal (+)
Output Terminal (-)
Output Terminal (-)
Frame Ground
AC (N)
AC(L)
SYMBOL
VB
CB
+V
+V
-V
-V
FG
N
L
SCREW
M3
M4
PIN
1
2
3-8
9
10
11-12
13
14
OPTIONAL CN3 PIN CONNECTIONS
FUNCTION
SYMBOL
ROF + (-R)
RC+
ROF - (-R)
RCN/C
NC
LV Alarm (-W)
LV+
LV Alarm Ground (-W)
LVN/C
NC
PF Alarm + (-W)
PF+
PF Alarm Ground (-W)
PF-
Connector
Mating Connector
CN3 S148B-PHDSS
PHDR-14VS
Terminal
Mfr
Chain: SPHD-002T-P.0.5
Loose: BPHD-001T-P0.5 J.S.T
BPHD-002T-P0.5
For mating loom kit for optional CN3 order
part number “CPK CN3 LOOM”
Average 21 A max per pin for TB1
Forced Air Cooling (60 CFM)
The temperature points A and B shown are marked
on the psu chassis.
• Point A must be ≤ 60°C and point B must be
≤65°C at Ta = 50°C.
• Point A must be ≤ 80°C and point B must be ≤
80°C at Ta = 70°C.
The confirmation of the temperatures of point A and
B is not necessary if option fan “-F” is used.
Load factor is dependent on input
voltage and is an average power figure.
(See part number table).
Convection Cooled - Derating Curves
Convection Cooled
CPK 750
Installation Method
Note: 1. Output ripple & noise may be outside specification.
2. Load factor dependent on input voltage (see part number table) and is an average power figure.
CPK 600
www.xpplc.com
CPK 1000
[email protected]
Peak Loading
3 conditions must be satisfied:
1. t1 ≤ 10 (second)
(Ppxt1) +(Poxt2)
2. Pave =
≤ rated power
t1+t2
t1
3. Duty =
≤0.35 (refer to graphs)
t1+t2
CPK 600
CPK1000
CPK 750
1. CPK115V convection
2. CPK115V forced air
3. CPK230V convection
4. CPK230V forced air
Remote ON/OFF
Example of using Remote ON/OFF
Option ‘-R’
Voltage Applied Between
RC (+) and RC (-)
SW ON
(4.5 - 12.5 V open circuit)
SW OFF
(0-0.5 V short circuit)
Output
ON
OFF
If external power source is in the range of 4.5-12.5 V, current limit resistor R is not
required. If external power source exceeds 12.5 V, current limit resistor R must be
connected.
To calculate the current limit resistance use following equation:
R (Ω) = Vcc - (1.1+Ri x 0.005)
0.005
Where;
Vcc = External Power Source
Ri = The internal resistance (780Ω)
Remote ON/OFF circuit (RC (+), RC (-) ) is isolated from input, output and FG.
Alarms
Option “-W”
• -W is available for detecting low input alarm (PF), detecting low
output voltage (LV) and operating N+1 redundancy.
• Alarm specifications are shown in Table.
• Each alarm (PF, LV) is isolated from input, output and FG.
PF
Alarm
If line voltage falls below 85 VAC
or fan stops
Output of alarm
Open collector method
Good: Low
(0-08. V, 1 mA max)
Fail: 50 V max
If the output voltage falls out of specified
LV
Internal circuit of PF
Notice:
1. When the output is over current
(intermittent current), the alarm is
unsettled status.
2. When parallel operating without
connecting diode,
LV alarm is not operating.
Open collector method
Good: Low
(0-08. V, 1 mA max)
Fail: 50 V max
Internal circuit of LV
www.xpplc.com
[email protected]
Rev 3.0