Emerson Network Power LPT80 Power factor correction Datasheet

Embedded Power for
Business-Critical Continuity
Rev. 05.23.08
LPT80 Series
1 of 3
LPT80 Series
RoHS
80 Watts
Total Power:
Input Voltage:
# of Outputs:
55 - 85 Watts
85-264 Vac
120-370 Vdc
Triple
Electrical Specifications
Special Features
•
•
•
•
•
•
•
•
•
•
Power Factor Correction
EN61000-3-2 compliant
Universal input
3” x 5” footprint
Remote sense on outputs 1
(& 2 for LPT81)
Power fail and remote inhibit
Wide range adjustable on
outputs 1 (& 2 for LPT81)
Built-in Class B EMI filter
Overvoltage protection
Overload protection
Input
Input range:
85-264 Vac; 120-300 Vdc
Frequency:
47-440 Hz
Inrush current:
<18 A peak @ 115 Vac;
<36 A peak @ 230 Vac,
cold start @ 25 °C
Input current:
1.5 A max. (RMS) @ 115 Vac
Efficiency:
EMI filter:
75% typical at full load
FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
Safety ground
leakage current:
<1 mA @ 50/60 Hz, 264 Vac input
Output
Maximum power:
Adjustment range:
Safety
VDE
UL
CSA
NEMKO
AUSTEL
CB
CE
Hold-up time:
60950
60950
60950
60950
60950
Certificate & report
Mark LVD
Overload protection:
60 W for convection( LPT81, 55 W);
85 W with 30 CFM forced air
3.3 V - 5.5 V on outputs one
(and two 1.8 V - 3.5 V for LPT81)
20 ms @85 W load, 115 Vac nominal line
Short circuit protection on all outputs.
Case overload protected @ 145% above peak rating
Overvoltage protection: Tracks outputs 1( & 2 for LPT81): 20% to 35% above
output setting
Embedded Power for
Business-Critical Continuity
Logic Control
Power failure
TTL logic signal goes high 100 - 500 msec after V1 output; It
goes low at least 4 msec before loss of regulation
Remote inhibit
Requires contact closure to inhibit outputs
Remote sense
Compensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected.
Environmental Specifications
Operating temperature:
0° to 50 °C ambient;
derate each output at 2.5% per degree from 50° to 70°C
Temperature coefficient: ±0.4% per °C
Storage temperature:
-40° to 85 °C
Electromagnetic
Designed to meet IEC EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3
susceptibility:
Humidity:
Operating; non-condensing 5% to 95%
Vibration:
MTBF demonstrated:
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four
major resonances 0.75 G peak 5 Hz to 500 Hz, operational
>550,000 hours at full load and 25 °C ambient conditions
Ordering Information
Maximum
Load with
Output
Minimum Maximum Load with 30CFM
Voltage
Load
Convection Cooling forced Air
+3.3 V (1.8 - 3.5 V) 0.7 A
8.0 A
13 A13 A
+5 V (3.3 - 5.5 V)
0.3 A
4.0 A
1.0 A
+12 V
0
0.7 A
Peak Load 1
15 A
15 A
1.5 A
Regulation 2
±2%
±2%
±5%
Ripple P/P
(PARD)3
50 mV
50 mV
120 mV
LPT82
+5 V (3.3 - 5.5 V)
+12 V
-12 V
0.7 A
0.3 A
0
8.0 A
3.0 A
0.7 A
13 A
4.0 A
1.0 A
15 A
4.6 A
1.5 A
±2%
±5%
±5%
50 mV
120 mV
120 mV
LPT83
+5 V (3.3 - 5.5 V)
+15 V
-15 V
0.7 A
0.3 A
0
8.0 A
2.4 A
0.7 A
13 A
3.2 A
0.7 A
15 A
3.7 A
1A
±2%
±5%
±5%
50 mV
150 mV
150 mV
Model
Number
LPT81
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load
ranges.
4. Minimum loads are required
5. Total current of all outputs can not exceed 21 A.
Rev. 05.23.08
LPT80 Series
2 of 3
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
Americas
5.00
(127.0)
0.23 (5.8)
(4x) .14 (Ø 3.6)
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 (760) 930 4600
Facsimile: +1 (760) 930 0698
Rev. 05.23.08
LPT80 Series
3 of 3
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
1
3.00
(76.2)
Asia (HK)
8
2.55"
(64.8)
4.56"
(115.8)
0.22 (5.6)
5
10
1
6
0.22 (5.6)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
techsupport.embeddedpower
@emerson.com
Mating Connectors
(SK1)AC Input:
Pin Assignments
Connector
LPT81
LPT82/83
SK1
Pin1
Neutral
Neutral
Pin3
Line
Line
Pin1
V1 (3.3V)
V1 (5 V)
Pin2
V1 (3.3V)
V1 (5 V)
Pin3
Common
Common
Pin4
Common
Common
Pin5
Common
Common
Pin6
V2 (5V)
V2 (12/15V)
Pin7
V2 (5V)
V2 (12/15V)
Pin8
V3 (12V)
V3 (-12V/15)
Pin1
+V1 Remote sense +V1 Remote sense
Pin2
-V1 Remote sense
-V1 Remote sense
Pin3
+Remote inhibit
+Remote inhibit
Pin4
-Remote inhibit
-Remote inhibit
Pin5
+Power fail
+Power fail
Pin6
Common
Common
Pin7
No connection
No connection
Pin8
+V2 sense
No connection
Pin9
-V2 sense
No connection
Pin10
No connection
No connection
SK2
SK3
(SK2)DC Outputs:
Molex 09-50-8031 (USA)
09-91-0300 (UK)
PINS: 08-58-0111
Molex 09-50-8081 (USA)
09-91-0800 (UK)
PINS: 08-58-0111
(SK3) Control Signals:
Molex 90142-0010 (USA)
PINS: 90119-2110 or
Amp: 87977-3
PINS: 87309-8
Astec connector kit:
#70-841-018
includes all the above
Notes:
1.Specifications subject to change without notice.
2.All dimensions in inches (mm), tolerance is ±.02”.
3.Mounting holes M1, M2 and M3 should be
grounded for EMI purposes.
4.Mounting hole M1 is safety ground connection.
5.Specifications are for convection rating at
factory settings at 115 VAC input, 25°C unless otherwise stated.
6.Warranty: 2 year
7.Weight: 0.8 lb. / 0.36 kg
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2008 Emerson Electric Co.
Similar pages