NI NIUSB-9237 Strain- and bridge-based measurement Datasheet

Strain- and Bridge-Based Measurements
NI USB-9237
• Full-, half-, and quarter-bridge
(120/350 Ω) completion1
• Bus powered
• Built-in excitation up to 10 V
• Up to 50 kS/s/ch sample rate
• Simultaneous acquisition with
four ADCs
• Quick sensor connect with
RJ50 connectors
• TEDS (IEEE 1454.1) compatible
• External excitation input through analog
bridge (optional)
1Quarter
bridge requires accessory.
Operating Systems
Compatible Software
•
•
•
•
•
•
LabVIEW
LabWindows™/CVI
Measurement Studio
Visual Basic 6.0
C# and Visual Basic .NET
ANSI C/C++
Measurement Services
Software (included)
• NI-DAQmx driver software
• Measurement & Automation Explorer
configuration utility
• LabVIEW SignalExpress LE
data-logging software
• Windows Vista/XP/2000
Overview
Connectivity
The National Instruments USB-9237 combines performance and
portability by making the NI 9237 C Series module compatible with the
bus-powered USB carrier for C Series modules. This module is ideal for
laptop applications because the USB port on the laptop powers all
acquisition and sensor excitation.
The USB-9237 uses four standard RJ50 connectors for rapid sensor
connection. You can add an RJ50 connector to any sensor using a
crimping tool, making sensor removal and insertion as easy as
connecting a PC to a network. For screw-terminal connectivity, the
NI 9949 accessory kit converts from RJ50 to 10 screw terminals. RJ50
cable kits are available in quantities of four 2 m cables and one 10 m
cable. For custom sensor wiring, cable kits are available with an RJ50
connector on one end and 10 signal wires on the other.
High-Speed Measurements
The NI USB-9237 module can take measurements at up to 50 kS/s on
four channels simultaneously and continuously stream the data back
over a Hi-Speed USB interface to serve applications from static load
or fatigue testing to high-speed fracture tests.
Sensor Compatibility
With full-, half-, and quarter-bridge completion, the USB-9237 can
measure a variety of load, force, and torque cells as well as some
pressure transducers and most strain gages.1
Safety Isolation
• 30 V of overvoltage protection
• 60 V of CAT I channel-to-earth ground isolation
• 1000 V of transient withstand isolation
1Quarter
bridge requires accessory.
Software
The USB-9237 is shipped with the standard NI-DAQmx bundle that
includes Measurement & Automation Explorer (MAX) for configuration
and testing; LabVIEW SignalExpress LE for out-of-the-box measurements,
logging, and data display; and an API/driver for languages such as
LabVIEW, ANSI C, C#, Visual Basic .NET, Visual Basic 6.0, Measurement
Studio, and LabWindows/CVI.
Strain- and Bridge-Based Measurements
Excitation Voltages
Specifications
>> For complete specifications, see the NI USB-9237 User Guide and
Specifications manual at ni.com/manuals.
Input Characteristics
Number of channels............................
Bridge completion
Full and half ....................................
Quarter............................................
ADC resolution................................
Type of ADC ....................................
4
Internal
External
24 bits
Delta-sigma
(with analog prefiltering)
Sampling mode............................... Simultaneous
Data rates (ƒs) ................................. (50 kS/s)/n, n= 1, 1, …31
Master timebase (internal)
Frequency........................................ 12.8 MHz
Accuracy ......................................... ±100 ppm max
Nominal full-scale range ................ ±25 mV/V
Scaling coefficient .............................. 2.9802 nV/V per LSB
Overvoltage protection
between any two terminals ........... ±30 V
Accuracy
Error1
Percent of Reading
Percent of Range2
Calibrated max (-40 to 70 °C)
0.20%
0.25%
Calibrated typ (25 °C, ±5 °C)
0.05%
0.05%
Uncalibrated max (-40 to 70 °C)
0.60%
0.35%
Uncalibrated typ (25 °C, ±5 °C)
0.20%
0.1%
1 Excluding offset null or shunt calibration. 2 Range equals 25 mV/V.
Gain drift .............................................
Offset drift
2.5 V excitation...............................
3.3 V excitation...............................
5 V excitation..................................
10 V excitation................................
10 ppm/°C max
0.6 μV/V per °C
0.5 μV/V per °C
0.3 μV/V per °C
0.2 μV/V per °C
Although the sensor industry does not recognize a single standard
excitation voltage level, excitation voltage levels of between 2.5 and
10 V are common. You can program the USB-9237 to supply 2.5, 3.3,
5, or 10 V of excitation voltage, and the module can provide up to
150 mW of excitation power. Unless you supply external excitation
voltage, National Instruments recommends that you set the excitation
voltage to a value that keeps the total power below 150 mW. The
USB-9237 automatically reduces internal excitation voltages as needed
to stay below 150 mW.
The power consumed by a single bridge is
2
V ex
--------R
where R is the total resistance of the bridge.
For a full bridge, R is equal to the resistance of each element. For a
half or quarter bridge, R is equal to two times the resistance of each
element.
With the 150 mW limit, you can power full and half bridges as
follows:
• Four 350 Ω half bridges at 5.0 V
• Four 350 Ω full bridges at 3.3 V
• Four 120 Ω half bridges at 2.5 V
If you need an excitation voltage greater than 150 mW, use the
four-position external excitation voltage connector to connect an
external excitation source to the USB-9237.
Channel Signal Names
RJ50 (10p10c) Modular Plug and RJ50 RJ45 Signal
Receptacle Pin Numbers
Pin Pin Name
1
2
3
4
5
6
7
8
9
10
Safety
Safety Voltages
Connect only voltages that are within these limits.
Between any two terminals ............... ±30 V max
Isolation
Channel-to-channel............................. No isolation between channels
Channel-to-earth ground
Continuous...................................... 60 VDC, Measurement Category I
Withstand ....................................... 1,000 Vrms, verified by a 5 s
dielectric withstand test
1
–
1
2
3
4
5
6
7
8
–
SC
AI+
AIRS+
RSEX+
EXT+
TSC
Signal Description
Shunt calibration
Positive input signal
Negative input signal
Positive remote sense signal
Negative remote sense signal
Positive excitation signal1
Negative excitation signal1
TEDS DATA
TEDS Return1
Shunt calibration
These signals are shared by all four RJ50 connectors on the USB-9237.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
2
Strain- and Bridge-Based Measurements
Accessories
Ordering Information
There are several options for connecting signals to the USB-9237, as
shown in figures 1 and 2.
NI USB-9237 (carrier, module, and USB cable) ....................780137-01
NI 9945 (1/4 bridge, 350 Ω, qty 4) ......................................194739-01
NI 9944 (1/4 bridge, 120 Ω, qty 4) ......................................194738-01
NI 9949 (RJ50 to screw terminal) ........................................196809-01
NI 9942 (excitation connector) ..............................................194611-01
RJ50 cable, 2 m (qty 4)..........................................................194612-02
RJ50 cable, 10 m (qty 1)........................................................194612-10
RJ50 to signal wire cable, 2 m (qty 4) ..................................195950-02
RJ50 to signal wire cable, 10 m (qty 1) ................................195950-10
BUY NOW!
For complete product specifications, pricing, and accessory
information, call 800 813 3693 (U.S.) or go to ni.com/compactdaq.
Figure 1. NI 9237 with RJ50 to 10 m Signal Wire Cable
Figure 2. NI 9237 with RJ50 Cable and Screw-Terminal Accessories
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
3
NI Services and Support
NI has the services and support to meet
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
that identifies individuals who have high levels of skill and knowledge on
using NI products. Visit ni.com/training.
Professional Services
Our NI Professional Services team is composed of NI applications
and systems engineers and a worldwide National Instruments Alliance
Partner program of more than 600 independent consultants and
integrators. Services range
from start-up assistance to
turnkey system integration.
Visit ni.com/alliance.
OEM Support
We offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
ni.com • 800 813 3693
National Instruments • [email protected]
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support.
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and configure
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online
with ni.com/pxiadvisor.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
*351510A-01*
351510A-01
2007-9107-301-101-D
© 2007 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com, SCXI, and
SignalExpress are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Other product and company names listed are
trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency,
partnership, or joint-venture relationship with National Instruments.
Similar pages