Vicor M-FIAM3 Military 270vin filter input attenuator module Datasheet

M-FIAM3
45
Military COTS 270Vin Filter
Input Attenuator Module
Features
•
•
•
•
•
•
•
•
EMI filtering-MIL-STD-461E
Transient protection-MIL-STD-704E/F
Environments-MIL-STD-810, MIL-STD-202
Environmental stress screening
Low profile mounting options
Output current up to 3 Amps
Mini sized package
Inrush current limiting
Shown actual size:
2.28 x 2.2 x 0.5 in
57,9 x 55,9 x 12,7 mm
Product Highlights
The M-FIAM3 is a DC front-end module
that provides EMI filtering and transient
protection. The M-FIAM3 enables designers
using Vicor 2nd Generation 300V DC-DC
converters to meet conducted emission/
conducted susceptibility per MIL-STD-461E;
and input transients per MIL-STD-704E/F.
The M-FIAM3 accepts an input voltage of
180-375Vdc and delivers output current up
to 3 Amps.
M-FIAM3 is housed in an industry
standard "half brick" module measuring
2.28" x 2.2" x 0.5" and depending upon
model selected, may be mounted on-board
or in-board for height critical applications.
Absolute Maximum Rating
Parameter
+In to –In
+In to –In
Mounting torque
Pin Soldering temperature
Pin Soldering temperature
Operating temperature H–Grade
Storage temperature H–Grade
Operating temperature M–Grade
Storage temperature M–Grade
Rating
Unit
375
Vdc
400
Vdc
5 (0.57)
in-lbs
500 (260) °F (°C)
750 (390) °F (°C)
-40 to +100
°C
-55 to +125
°C
-55 to +100
°C
-65 to +125
°C
Notes
Continuous
100ms
6 each, #4-40 or M3
<5 sec; wave solder
<7 sec; hand solder
Baseplate
Baseplate
Specifications
(typical at TBP = 25ºC, nominal line, 75% load, unless otherwise specified)
Parameter
Input voltage
Output current
Inrush limiting
Transient immunity
EMI:MIL-STD-461E
Conducted emissions:
Conducted susceptibility:
Dielectric withstand
Compatible Products
• 2nd Generation 300V Input
DC-DC converters
Part Number Format
M-FIAM3 M
2
1
Product
Product Grade(°C)
H = –40 to +100
M = –55 to +100
Pin Style
1 = Short
2 = Long
*S=Short ModuMate
*N=Long ModuMate
Baseplate
1 = Slotted
2 = Threaded
3 = Thru-hole
Efficiency
Internal voltage drop
ON/OFF control
Enable (ON)
Disable (OFF)
External capacitance
Min
180Vdc
Typ
270Vdc
Max
Remarks
375Vdc Continuous
3A
0.018A/µF
Exceeds limits of MIL-STD-704E/F
CE101, CE102
CS101, CS114, CS115, CS116
1,500Vrms
2,121Vdc
96%
98%
3.0Vdc
5.0Vdc
0.0Vdc
3.5Vdc
1.0Vdc
5.0Vdc
10µF
Weight
Warranty
22µF
3.3 (94)
2
Input/Output to base
Input/Output to base
@ 3A, 100°C baseplate
Referenced to –Vout.
100kΩ internal pull-up resistor
See illustration C1 on page 3.
400V
Ounces (grams)
Years
*Compatible with SurfMate and InMate socketing systems.
MTBF per MIL-HDBK-217F (M-FIAM3M21)
Thermal Resistance
Parameter
Typ
Baseplate to sink; flat, greased surface
0.16°C/Watt
Baseplate to sink; thermal pad (P/N 20264) 0.1°C/Watt
Baseplate to ambient
7.9°C/Watt
Baseplate to sink; 1000 LFM
2.2°C/Watt
Temp.
25°C
50°C
65°C
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Environment
Ground benign:G.B.
Naval sheltered:N.S.
Airborne inhabited cargo:A.I.C.
MTBF
4,031
725
568
MFIAM3
Set your site on VICOR at www.vicorpower.com
Unit
1,000 Hrs
1,000 Hrs
1,000 Hrs
Rev. 1.8
Page 1 of 4
Environmental Qualification
Environmental Stress Screening
Altitude
MIL-STD-810C, Method 500.2, Procedure I & II, 40,000 ft. and
70,000 ft. Operational.
Operating Temp.
Storage Temp.
Temp. Cycling:*
Explosive Atmosphere
MIL-STD-810F, Method 511.4, Procedure I, Operational.
Vibration
MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine
and Random vibration per Table 514.5C for Helicopter AH-6J
Main Rotor with overall level of 5.6 grams for 4 hours per axis.
MIL-STD-810F, Method 514.5C, General Minimum Integrity
Curve per Figure 514.5C-17 with overall level of 7.7 grams
for 1 hour per axis.
Shock
MIL-STD-810-F, Method 516.5, Procedure I, Functional Shock,40 G's.
MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft.
MIL-STD-202F, Method 213B, 60 G's, 9ms half sine.
MIL-STD-202F, Method 213B, 75 G's, 11ms Saw Tooth Shock.
H Grade
-40°C to +100°C
-55°C to +125°C
12 cycles
-65°C to +100°C
M Grade
-55°C to +100°C
-65°C to +125°C
12 cycles
-65°C to +100°C
Yes
Yes
12 hours,
28 cycles
24 hours,
56 cycles
-40°C and
+100°C
-55°C and
+100°C
Yes
Yes
vicorpower.com
Yes
Yes
vicorpower.com
Ambient Test
@ 25°C
Power Cycling
Burn-In:
Functional and
Parametric
ATE Tests:
Hi-Pot Test
Visual Inspection:
Test Data
*Temperature cycled with power off, 17°C per minute rate of change.
Conducted Noise
Acceleration
MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II,
Operational, 2-7 G's, 6 directions.
Humidity
MIL-STD-810F, Method 507.4, Procedure I, Cycle I, 240 hrs, 95% RH.
Solder Test
MIL-STD-202F, Method 208, 8 hour aging.
Figure 1– M-FIAM3 and Model V300A48M500AL
DC-DC converter operating at 180Vdc, 130W.
Inrush Limiting
Transient Immunity
Output
Input
Figure 2 – Transient Immunity: M-FIAM3 output response to
an input transient.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Figure 3– Inrush Limiting: Inrush current with 22µF external
capacitance.
MFIAM3
Set your site on VICOR at www.vicorpower.com
Rev. 1.8
Page 2 of 4
Transient and Surge Protection
Note: The M-FIAM3 is shown in the on state. To disable,
open the connection between ON/OFF and –Out.
–IN
–
–
MOV P/N
03040
M-FIAM3
+IN
–OUT
–IN
ON
OFF
EMI
GND
PR
C1
NC
NC
NC
PC
+
+
+IN
Capacitance (C1)
10µF(min),22µF(max)
Recommended Fuse:
3A Max., F03A Type
–S
2nd Generation
300Vdc Input
DC-DC Converters
SC
+S
+OUT
Mechanical Diagram
Module Pins
No.
Function
Label
1
+In
+
2
No
Connection
NC
0.50 ±0.02
12,7 ±0,5
3
Ground
EMI/GND
4
– In
–
5
– Out
–
6
ON/OFF
ON/OFF
7
No
Connection
NC
8
No
Connection
NC
9
+Out
+
2.20
55,9
1.74
44,2
0.23
(REF)
5,8
0.01
style 2 & 3
baseplates only
(4X)***
0.300 ±0.015
7,62 ±0,38
1
2
3
0.10
2,5
0.10
X 45˚
2,5
CHAMFER
4
(ALL MARKINGS
THIS SURFACE)
0.300 ±0.015
7,62 ±0,38
2.000
50,80
0.49
12,4
0.12* 0.20**
3,1 5,1
0.35 (2X)
8,8
1.900
48,26
ALUMINUM
BASEPLATE
2.28 1.30
57,9 33,0
0.65
16,5
FULL R (6X)
0.130
3,30
9
8
7
6
0.150 DIA,(2X)
3,81
0.080 DIA,(7X)
2,03
0.400
10,16
0.43
10,9
0.700
17,78
1.000
25,40
1.400
35,56
Slotted (Style 1)
or
(6X)
5
0.06
R
(3X)
1,5
0.54
(9X)
13,7
Short Pin
0.62
(9X)
15,7
Long Pin
2.20
55,9
(REF.)
Use a 4-40 Screw (6X)
Torque to:
5 in-lbs
.57 N-m
Threaded (Style 2)
4-40 UNC-2B (6X)
or
Thru Hole (Style 3)
* Style 1 baseplate only
** Style 2 & 3 baseplates
*** Reserved for Vicor accessories
Not for mounting
#30 Drill Thru (6X)
(0.1285)
PCB Mounting Specifications
PCB THICKNESS
R
0.062 ±0.010
1,57 ±0,25
PLATED
THRU HOLE
DIA
1.790
45,47
0.06
(4X)
1,5
ONBOARD
SOLDER
MOUNT
SHORT PIN STYLE
LONG PIN STYLE
(7X)
0.094 ±0.003
2,39 ±0,08
0.094 ±0.003
2,39 ±0,08
(2X)
0.164 ±0.003
4,16 ±0,08
0.164 ±0.003
4,16 ±0,08
ies
ALL MARKINGS
THIS SURFACE
0.158
4,01
1
2
3
ALUMINUM
BASEPLATE
4
PINS STYLES
SOLDER:TIN/LEAD
HOT SOLDER DIPPED
MODUMATE: GOLD PLATED COPPER
1.584*
40,23
1.900*
48.26
48,26
9
8
7
6
5
0.400*
10,16
0.43
10,9
0.700*
17,78
0.195
4,95
INBOARD
SOLDER
MOUNT
1.000*
25,40
1.400*
35,56
0.53
13,5
* DENOTES
±0.003
TOL =
±0,08
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MFIAM3
Set your site on VICOR at www.vicorpower.com
Rev. 1.8
Page 3 of 4
Vicor’s comprehensive line of power solutions includes high density AC-DC
and DC-DC modules and accessory components, fully configurable AC-DC
and DC-DC power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is
assumed by Vicor for its use. Vicor components are not designed to be used in applications, such as life
support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to
Vicor’s Terms and Conditions of Sale, which are available upon request.
Specifications are subject to change without notice.
Component Solutions
for Your Power System
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
978-470-2900
Fax: 978-475-6715
Email
Vicor Express: [email protected]
Technical Support: [email protected]
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
FARM, Filter/Autoranging Rectifier Module
Set your site on VICOR at www.vicorpower.com
Rev. 1.8
06/05