Sanyo LC72130M Am/fm pll frequency synthesizer Datasheet

Ordering number : EN4973A
CMOS LSI
LC72130, 72130M
AM/FM PLL Frequency Synthesizer
Overview
Package Dimensions
The LC72130 and LC72130M are PLL frequency
synthesizers for use in tuners in radio cassette recorders
and other products.
unit: mm
3067-DIP24S
[LC72130]
Applications
PLL frequency synthesizer
Functions
• High-speed programmable dividers
— FMIN: 10 to 160 MHz ..........pulse swallower
(built-in divide-by-two prescaler)
— AMIN: 2 to 40 MHz ..............pulse swallower
0.5 to 10 MHz ...........direct division
• IF counter
— IFIN: 0.4 to 12 MHz ...........AM/FM IF counter
• Reference frequencies
— Twelve selectable frequencies
(4.5 or 7.2 MHz crystal)
1, 3, 5, 9, 10, 3.125, 6.25, 12.5, 15, 25, 50 and 100 kHz
• Phase comparator
— Dead zone control
— Unlock detection
— Deadlock clear circuit
• Built-in MOS transistor for implementing an active lowpass filter (two systems)
• Inputs and outputs
— Dedicated output ports: five pins
— Input or output ports: two pins
— Clock time base output available
• Serial data I/O
— Supports CCB format communication with the
system controller.
• Operating ranges
— Supply voltage........................4.5 to 5.5 V
— Operating temperature............–40 to +85°C
• Packages
— DIP24S, MFP24S
SANYO: DIP24S
unit: mm
3112-MFP24S
[LC72130M]
SANYO: MFP24S
• CCB is a trademark of SANYO ELECTRIC CO., LTD.
• CCB is SANYO’s original bus format and all the bus
addresses are controlled by SANYO.
SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquarters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110 JAPAN
N3096HA (OT)/51795TH (OT) No. 4973-1/22
LC72130, 72130M
Pin Assignment
No. 4973-2/22
LC72130, 72130M
Block Diagram
No. 4973-3/22
LC72130, 72130M
Specifications
Absolute Maximum Ratings at Ta = 25°C, VSS = 0 V
Parameter
Symbol
Maximum supply voltage
Maximum input voltage
Maximum output voltage
Maximum output current
Allowable power dissipation
Pins
Ratings
Unit
VDD max
VDD
–0.3 to +7.0
VIN1 max
CE, CL, DI, AIN1, AIN2
–0.3 to +7.0
V
VIN2 max
XIN, FMIN, AMIN, IFIN
–0.3 to VDD + 0.3
V
V
VIN3 max
IO1, IO2
–0.3 to +15
V
VO1 max
DO
–0.3 to +7.0
V
–0.3 to VDD + 0.3
V
VO2 max
XOUT, PD1, PD2
VO3 max
BO1 to BO5, IO1, IO2, AOUT1, AOUT2
IO1 max
BO1
IO2 max
IO3 max
–0.3 to +15
mA
DO, AOUT1, AOUT2
0 to 6.0
mA
BO2 to BO5, IO1, IO2
0 to 10.0
mA
DIP24S: 350
MFP24S: 200
mW
Ta ≤ 85°C
Pd max
V
0 to 3.0
Operating temperature
Topr
–40 to +85
°C
Storage temperature
Tstg
–55 to +125
°C
Parameter
Supply voltage
Input high level voltage
Input low level voltage
Symbol
VDD
VIH1
VIH2
Input amplitude
Oscillation-guaranteed
crystal resonator
Conditions
min
typ
max
Unit
4.5
5.5
V
CE, CL, DI
0.7 VDD
6.5
V
IO1, IO2
V
0.7 VDD
13
VIL
CE, CL, DI, IO1, IO2
0
0.3 VDD
V
VO1
DO
0
6.5
V
V O2
BO1 to BO5, IO1, IO2,
AOUT1, AOUT2
0
13
V
fIN1
XIN
VIN1
1
8
MHz
fIN2
FMIN
VIN2
10
160
MHz
fIN3
AMIN
VIN3, SNS = 1
2
40
MHz
fIN4
AMIN
VIN4, SNS = 0
0.5
10
MHz
fIN5
IFIN
VIN5
0.4
12
VIN1
XIN
fIN1
400
1500
mVrms
VIN2-1
FMIN
f = 10 to 130 MHz
40
1500
mVrms
VIN2-2
FMIN
f = 130 to 160 MHz
70
1500
mVrms
VIN3
AMIN
fIN3 , SNS = 1
40
1500
mVrms
VIN4
AMIN
fIN4 , SNS = 0
40
1500
mVrms
VIN5
IFIN
fIN5, IFS = 1
40
1500
mVrms
VIN6
IFIN
fIN6, IFS = 0
70
1500
mVrms
Xtal
XIN, XOUT
*
4.0
8.0
Output voltage
Input frequency
Pins
VDD
MHz
MHz
Allowable Operating Ranges at Ta = –40 to +85°C, VSS = 0 V
Note: * Recommended crystal oscillator CI values:
CI ≤ 120Ω (For a 4.5 MHz crystal)
CI ≤ 70Ω (For a 7.2 MHz crystal)
However, since the oscillator circuit characteristics depend on the printed circuit board and component values actually used, we recommend
requesting a circuit evaluation from the manufacturer of the crystal used.
<Sample Ocsillator Circuit>
Crystal oscillator: HC-49/U (manufactured by Kinseki, Ltd.), CL = 12 pF
C1 = C2 = 15 pF
The circuit constants for the crystal oscillator circuit depend on the crystal used, the printed circuit board pattern, and other items. Therefore we
recommend consulting with the manufacturer of the crystal for evaluation and reliability.
No. 4973-4/22
LC72130, 72130M
Electrical Characteristics at Ta = –40 to +85°C, VSS = 0 V
Parameter
Symbol
Pins
Conditions
min
typ
max
Unit
Rf1
XIN
1.0
MΩ
Rf2
FMIN
500
kΩ
Rf3
AMIN
500
kΩ
Rf4
IFIN
250
kΩ
Rpd1
FMIN
200
kΩ
Rpd2
AMIN
200
kΩ
Hysteresis
VHIS
CE, CL, DI, IO1, IO2
Output high level voltage
VOH1
PD1, PD2
IO = –1 mA
VOL1
PD1, PD2
IO = 1 mA
1.0
V
IO = 0.5 mA
0.5
V
IO = 1 mA
1.0
V
IO = 1 mA
0.2
V
IO = 5 mA
1.0
V
IO = 1 mA
0.2
V
IO = 5 mA
1.0
V
IO = 8 mA
1.6
V
AOUT1, AOUT2
IO = 1 mA, AIN = 1.3 V
0.5
V
IIH1
CE, CL, DI
VI = 6.5 V
5.0
V
IIH2
IO1, IO2
VI = 13 V
5.0
µA
Built-in feedback resistance
Built-in pull-down resistor
VOL2
Output low level voltage
VOL3
VOL4
VOL5
Input high level current
Input low level current
Output off leakage current
BO1
DO
BO2 to BO5, IO1, IO2
0.1 VDD
V
VDD – 1.0
V
IIH3
XIN
VI = VDD
2.0
11
µA
IIH4
FMIN, AMIN
VI = VDD
4.0
22
µA
IIH5
IFIN
VI = VDD
8.0
44
µA
IIH6
AIN1, AIN2
VI = 6.5 V
200
nA
IIL1
CE, CL, DI
VI = 0 V
5.0
µA
IIL2
IO1, IO2
VI = 0 V
5.0
µA
IIL3
XIN
VI = 0 V
2.0
11
µA
IIL4
FMIN, AMIN
VI = 0 V
4.0
22
µA
IIL5
IFIN
VI = 0 V
8.0
44
µA
IIL6
AIN1, AIN2
VI = 0 V
200
nA
IOFF1
BO1 to BO5, AOUT1,
AOUT2, IO1, IO2
VO = 13 V
5.0
µA
5.0
µA
IOFF2
DO
VO = 6.5 V
High level three-state
off leakage current
IOFFH
PD1, PD2,
VO = VDD
0.01
200
nA
Low level three-state
off leakage current
IOFFL
PD1, PD2
VO = 0 V
0.01
200
nA
Input capacitance
CIN
6
VDD
Xtal = 7.2 MHz,
fIN2 = 130 MHz,
VIN2-1= 40 mVrms
IDD2
VDD
PLL block stopped
(PLL INHIBIT),
Xtal oscillator operating
(Xtal = 7.2 MHz)
IDD3
VDD
PLL block stopped
Xtal oscillator stopped
IDD1
Current drain
FMIN
5
pF
10
0.5
mA
mA
10
µA
No. 4973-5/22
LC72130, 72130M
Pin Functions
Symbol
XIN
XOUT
FMIN
Pin No.
1
24
15
Type
Functions
X’tal OSC
• Crystal resonator connection
(4.5/7.2 MHz)
Local oscillator
signal input
• Serial data input: FMIN is selected when DVS is set to 1.
• The input frequency range is from 10 to 160 MHz.
• The signal is passed through a built-in divide-by-two
prescaler and then supplied to the swallow counter.
• Although the range of divisor settings is from 272 to
65,535, the actual divisor is twice the setting since there
is also a built-in divide-by-two prescaler.
AMIN
14
Local oscillator
signal input
• Serial data input: AMIN is selected when DVS is set to 0.
• Serial data input: When SNS is set to 1:
— The input frequency range is from 2 to 40 MHz.
— The signal is supplied directly to the swallow counter.
— The range of divisor settings is from 272 to 65,535
and the actual divisor will be the value set.
• Serial data input: When SNS is set to 0:
— The input frequency range is from 0.5 to 10 MHz.
— The signal is supplied directly to a 12-bit
programmable divider.
— The range of divisor settings is from 4 to 4,095 and
the actual divisor will be the value set.
CE
3
Chip enable
• Must be set high when serial data is input to the
LC72130 (DI), or when serial data is output (DO).
CL
5
Clock
• Used as the synchronization clock when serial data is
input to the LC72130 (DI), or when serial data is output
(DO).
DI
4
Data input
• Inputs serial data sent from the controller to the
LC72130.
DO
6
Data output
• Outputs serial data sent from the LC72130 to the
controller.
The content of the output data is determined by the
serial data DOC0 to DOC2.
VDD
16
Power supply
• The LC72130 power supply (VDD = 4.5 to 5.5 V)
• The power on reset circuit operates when power is first
applied.
Circuit configuration
Continued on next page.
No. 4973-6/22
LC72130, 72130M
Continued from preceding page.
Symbol
VSS
BO1
BO2
BO3
BO4
BO5
IO1
IO2
PD1
PD2
AIN1
AOUT1
AIN2
AOUT2
IFIN
Pin No.
23
7
8
9
10
2
11
13
19
20
18
17
21
22
12
Type
Functions
Ground
• The LC72130 ground
Output port
• Dedicated output pins
• The output states are determined by BO1 to BO5 in the
serial data.
Data: 0 = open, 1 = low
• These pins go to the open state after the power on reset.
• An 8 Hz time base signal can be output from BO1 when
TBC in the serial data is set to 1.
• Note that the ON impedance of the BO1 pin is higher
than that of the other pins (BO2 to BO5).
I/O port
• Pins used for both input and output
• The input or output state is determined by bits IOC1 and
IOC2 in the serial data.
Data: 0 = input port, 1 = output port
• When specified for use as an input port:
The input state is transmitted to the controller through
the DO pin.
Input state: Low → data value = 0
High → data value = 1
• When specified for use as an output port:
The output state is determined by bits IO1 and IO2 in the
serial data.
Data: 0 = open, 1 = low
• These pins go to the input port state after the power ON
reset.
Charge pump
output
• PLL charge pump output
When the frequency generated by dividing the local
oscillator frequency by N is higher than the reference
frequency, a high level will be output from the PD pin.
Similarly, when that frequency is lower, a low level will
be output. The PD pin goes to the high impedance state
when the frequencies agree.
LPF amplifier
transistor
• The MOS transistor used for the PLL active low-pass
filter.
IF counter
• The input frequency range is from 0.4 to 12 MHz.
• The signal is supplied directly to the IF counter.
• The result from the IF counter MSB is output through the
DO pin.
• There are four measurement periods: 4, 8, 32, or 64 ms.
Circuit configuration
—
No. 4973-7/22
LC72130, 72130M
Serial Data I/O Methods
The LC72130 uses Sanyo’s audio LSI serial bus format, the CCB (computer control bus) format, for data I/O. This LSI
adopts an 8-bit address version of the CCB format.
I/O mode
Address
B0
B1
B2
B3
A0
A1
A2
A3
Function
1
IN1 (82)
0
0
0
1
0
1
0
0
• This is a control data input (serial data input) mode.
• 24 bits of data are input.
• See the “DI Control Data (Serial Data Input)” item for a
description of the contents of the input data.
2
IN2 (92)
1
0
0
1
0
1
0
0
• This is a control data input (serial data input) mode.
• 24 bits of data are input.
• See the “DI Control Data (Serial Data Input)” item for a
description of the contents of the input data.
0
• This is a data output (serial data output) mode.
• The number of bits output is equal to the number of clock
cycles.
• See the “DO Control Data (Serial Data Output)” item for a
description of the content of the output data.
3
OUT (A2)
0
1
0
1
0
1
0
No. 4973-8/22
LC72130, 72130M
1. DI Control Data (Serial Data Input)
• IN1 Mode
• IN2 Mode
No. 4973-9/22
LC72130, 72130M
2. DI Control Data Functions
No.
Control block/data
Functions
Related data
Programmable divider data • Sets the programmable divider divisor.
P0 to P15
(1)
This value is a binary value whose MSB is P15. The position of the LSB varies
depending on DVS and SNS. (*: don’t care)
DVS
SNS
LSB
Divisor setting (N)
1
*
P0
272 to 65535
Actual divisor
0
1
P0
272 to 65535
The value of the setting
0
0
P4
4 to 4095
The value of the setting
Twice the value of the setting
Note: P0 to P3 are ignored when P4 is the LSB.
DVS, SNS
• These bits select the signal input pin for the programmable divider and switch the input
frequency range. (*: don’t care)
DVS
SNS
Input pin
Input frequency range
1
*
FMIN
10 to 160 MHz
0
1
AMIN
2 to 40 MHz
0
0
AMIN
0.5 to 10 MHz
Note: See the “Programmable Divider” item for more information.
Reference divider data
R0 to R3
(2)
• Selects the reference frequency (fref).
R3
R2
R1
R0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
Reference frequency (kHz)
1
1
1
1
0
0
0
0
0
0
1
1
0
1
0
1
10
9
5
1
1
1
1
1
0
0
0
1
3
15
1
1
1
0
PLL INHIBIT + X’tal OSC STOP
100
50
25
25
12.5
6.25
3.125
3.125
1
1
1
1
PLL INHIBIT
Note: PLL INHIBIT
The programmable divider block and the IF counter block are stopped, the FMIN,
AMIN, and IFIN pins are set to the pull-down state (ground), and the charge pump
goes to the high impedance state.
XS
• Crystal resonator selection
XS = 0: 4.5 MHz
XS = 1: 7.2 MHz
The 7.2 MHz frequency is selected after the power ON reset.
IF counter control data
CTE
• IF counter measurement start data
CTE = 1: Counter start
CTE = 0: Counter reset
GT0, GT1
• Determines the IF counter measurement period.
(3)
GT1
GT0
0
0
Measurement time (ms)
4
Wait time (ms)
IFS
3 to 4
0
1
8
3 to 4
1
0
32
7 to 8
1
1
64
7 to 8
Note: See the “IF Counter” item for more information.
(4)
(5)
I/O port specification data
IOC1, IOC2
• Specifies the I/O direction for the bidirectional pins IO1 and IO2.
Data: 0 = input mode, 1 = output mode
Output port data
BO1 to BO5, IO1, IO2
• Data that determines the output from the BO1 to BO5, IO1 and IO2 output ports
Data: 0 = open, 1 = low
• The data = 0 (open) state is selected after the power ON reset.
IOC1
IOC2
Continued on next page.
No. 4973-10/22
LC72130, 72130M
Continued from preceding page.
No.
Control block/data
DO pin control data
DOC0, DOC1, DOC2
Functions
Related data
• Data that determines the DO pin output
DOC2
DOC1
DOC0
0
0
0
0
0
0
1
1
0
1
0
1
Open
Low when the unlock state is detected
end-UC*1
Open
DO pin state
1
1
1
1
0
0
1
1
0
1
0
1
Open
The IO1 pin state*2
The IO2 pin state*2
Open
The open state is selected after the power ON reset.
Note: 1. end-UC: Check for IF counter measurement completion
UL0, UL1,
CTE,
IOC1, IOC2
(6)
➀ When end-UC is set and the IF counter is started (i.e., when CTE is changed
from zero to one), The DO pin automatically goes to the open state.
➁ When the IF counter measurement completes, the DO pin goes low to indicate
the measurement completion state.
➂ Depending on serial data I/O (CE: high) the DO pin goes to the open state.
2. Goes to the open state if the I/O pin is specified to be an output port.
Caution: The state of the DO pin during a data input period (an IN1 or IN2 mode period with CE
high) will be open, regardless of the state of the DO control data (DOC0 to DOC2).
Also, the DO pin during a data output period (an OUT mode period with CE high)
will output the contents of the internal DO serial data in synchronization with the
CL pin signal, regardless of the state of the DO control data (DOC0 to DOC2).
Unlock detection data
UL0, UL1
(7)
• Selects the phase error (øE) detection width for checking PLL lock.
A phase error in excess of the specified detection width is seen as an unlocked state.
UL1
UL0
0
0
Stopped
øE detection width
Open
Detector output
0
1
0
øE is output directly
1
0
±0.55 µs
øE is extended by 1 to 2 ms
1
1
±1.11 µs
øE is extended by 1 to 2 ms
DOC0,
DOC1,
DOC2
Note: In the unlocked state the DO pin goes low and the UL bit in the serial data
becomes zero.
Phase comparator
control data
DZ0, DZ1
(8)
• Controls the phase comparator dead zone.
DZ1
DZ0
0
0
Dead zone mode
DZA
0
1
DZB
1
0
DZC
1
1
DZD
Dead zone widths: DZA < DZB < DZC < DZD
(9)
Clock time base
TBC
Charge pump control data
DLC
Setting TBC to one causes an 8 Hz, 40% duty clock time base signal to be output
from the BO1 pin. (BO1 data is invalid in this mode.)
DLC
(10)
BO1
• Forcibly controls the charge pump output.
Charge pump output
0
Normal operation
1
Forced low
Note: If deadlock occurs due to the VCO control voltage (Vtune) going to zero and the VCO
oscillator stopping, deadlock can be cleared by forcing the charge pump output to
low and setting Vtune to VCC. (This is the deadlock clearing circuit.)
Continued on next page.
No. 4973-11/22
LC72130, 72130M
Continued from preceding page.
No.
(11)
Control block/data
IF counter control data
LSI test data
TEST 0 to TEST2
(12)
Functions
Related data
• Note that if this value is set to zero the system enters input sensitivity degradation mode,
and the sensitivity is reduced to 10 to 30 mV rms.
* See the “IF Counter Operation” item for details.
• LSI test data
TEST0
TEST1
These values must all be set to 0.
TEST2
These test data are set to 0 automatically after the power ON reset.
3. DO Output Data (Serial Data Output)
• OUT Mode
4. DO Output Data
No.
Control block/data
I/O port data
I2, I1
(1)
Functions
• Latched from the pin states of the IO1 and IO2 I/O ports.
• These values follow the pin states regardless of the input or output setting.
• Data is latched at the point where the circuit enters data output mode (OUT mode)
I1 ← IO1 pin state
I2 ← IO2 pin state
High: 1
Low: 0
Related data
IOC1,
IOC2
(2)
PLL unlock data
UL
• Latched from the state of the unlock detection circuit.
UL ← 0: Unlocked
UL ← 1: Locked or detection stopped mode
UL0,
UL1
(3)
IF counter binary data
C19 to C0
• Latched from the value of the IF counter (20-bit binary counter).
C19 ← MSB of the binary counter
C0 ← LSB of the binary counter
CTE,
GT0,
GT1
No. 4973-12/22
LC72130, 72130M
5. Serial Data Input (IN1/IN2) tSU, tHD, tEL, tES, tEH ≥ 0.75 µs, tLC ≤ 0.75 µs
➀ CL: Normal high
➁ CL: Normal low
6. Serial Data Output (OUT) tSU, tHD, tEL, tES, tEH ≥ 0.75 µs, tDC, tDH ≤ 0.35 µs
➀ CL: Normal high
➁ CL: Normal low
Note: Since the DO pin is an n-channel open drain pin, the time for the data to change (tDC and tDH) will differ depending on the value of the pull-up resistor
and printed circuit board capacitance.
No. 4973-13/22
LC72130, 72130M
7. Serial Data Timing
Parameter
Symbol
Pins
Conditions
min
typ
max
Unit
Data setup time
tSU
DI, CL
0.75
µs
Data hold time
tHD
DI, CL
0.75
µs
Clock low-level time
tCL
CL
0.75
µs
Clock high-level time
tCH
CL
0.75
µs
CE wait time
tEL
CE, CL
0.75
µs
CE setup time
tES
CE, CL
0.75
µs
CE hold time
tEH
CE, CL
0.75
Data latch change time
tLC
tDC
DO, CL
tDH
DO, CE
Data output time
Differs depending on the
value of the pull-up resistor
and the printed circuit board
capacitance.
µs
0.75
µs
0.35
µs
No. 4973-14/22
LC72130, 72130M
Programmable Divider
DVS
SNS
Input pin
Set divisor
Actual divisor: N
A
1
*
FMIN
272 to 65535
Twice the set value
Input frequency range (MHz)
B
0
1
AMIN
272 to 65535
The set value
2 to 40
C
0
0
AMIN
4 to 4095
The set value
0.5 to 10
10 to 160
Note: * Don’t care.
1. Programmable Divider Calculation Examples
• FM, 50 kHz steps (DVS = 1, SNS = *, FMIN selected)
FM RF = 90.0 MHz (IF = +10.7 MHz)
FM VCO = 100.7 MHz
PLL fref = 25 kHz (R0 to R1 = 1, R2 to R3 = 0)
100.7 MHz (FM VCO) ÷ 25 kHz (fref) ÷ 2 (FMIN: divide-by-two prescaler) = 2014 → 07DE (HEX)
• SW, 5 kHz steps (DVS = 0, SNS = 1, AMIN high speed side selected)
SW RF = 21.75 MHz (IF = +450 kHz)
SW VCO = 22.20 MHz
PLL fref = 5 kHz (R0 = R2 = 0, R1 = R3 = 1)
22.2 MHz (SW VCO) ÷ 5 kHz (fref) = 4440 → 1158 (HEX)
• MW, 10 kHz steps (DVS = 0, SNS = 0, AMIN low-speed side selected)
MW RF = 1000 kHz (IF = +450 kHz)
MW VCO = 1450 kHz
PLL fref = 10 kHz (R0 to R2 = 0, R3 = 1)
1450 kHz (MW VCO) ÷ 10 kHz (fref) = 145 → 091 (HEX)
No. 4973-15/22
LC72130, 72130M
IF Counter
The LC72130 IF counter is a 20-bit binary counter. The result, i.e., the counter’s msb, can be read serially from the DO pin.
Measurement time
GT1
GT0
0
0
4
3 to 4
0
1
8
3 to 4
Measurement period (GT) (ms)
Wait time (twu) (ms)
1
0
32
7 to 8
1
1
64
7 to 8
The IF frequency (Fc) is measured by determining how many pulses were input to an IF counter in a specified
measurement period, GT.
Fc =
C
GT
(C = Fc × GT)
C: Count value (number of pulses)
1. IF Counter Frequency Calculation Examples
• When the measurement period (GT) is 32 ms, the count (C) is 53980 hexadecimal (342400 decimal):
IF frequency (Fc) = 342400 ÷ 32 ms = 10.7 MHz
• When the measurement period (GT) is 8 ms, the count (C) is E10 hexadecimal (3600 decimal):
IF frequency (Fc) = 3600 ÷ 8 ms = 450 kHz
No. 4973-16/22
LC72130, 72130M
2. IF Counter Operation
Prior to starting the IF counter, reset the IF counter in advance by setting CTE in the serial data to zero.
The IF counter is started by changing the value of CTE in the serial data from zero to one. The serial data is latched
when the CE pin is dropped from high to low. The IF signal must be supplied to the IFIN pin in the period between
the point the CE pin goes low and the end of the wait time at the latest. Next, the value of the IF counter at the end of
the measurement period must be read out during the period that CTE is 1. This is because the IF counter is reset
when CTE is set to 0.
Note: When operating the IF counter, the control microprocessor must check for the presence of the IF-IC SD
(station detect signal) and, must turn on the IF buffer output and operate the counter only if the SD signal is
present. Autosearch techniques that use only the IF counter are not recommended, since it is possible for IF
buffer leakage output to cause incorrect stops at points where there is no station.
IFIN minimum input sensitivity standard
f (MHz)
0.4 ≤ f < 0.5
0.5 ≤ f < 8
8 ≤ f ≤ 12
1: Normal mode
40 mVrms
(0.1 to 3 mVrms)
40 mVrms
40 mVrms
(1 to 10 mVrms)
0: Degradation mode
70 mVrms
(10 to 15 mVrms)
70 mVrms
70 mVrms
(30 to 40 mVrms)
IFS
( ): Actual values (reference data)
No. 4973-17/22
LC72130, 72130M
Unlock Detection Timing
1. Unlock Detection Determination Timing
Unlocked state detection is performed in the reference frequency (fref) period (interval). Therefore, in principle, this
determination must be performed over a period no less than the reference frequency period. However, directly
following a change to the (frequency) divisor N, that determination must be performed after at least two reference
frequency periods have passed.
Figure 1 Unlocked State Detection Timing
For example, if fref is 1 kHz, i.e., the period is 1 ms, after the divisor N is changed, unlocked state determination
must be performed after waiting 2 ms.
Figure 2 Circuit Structure
No. 4973-18/22
LC72130, 72130M
2. Unlock Determination Software Integration Method
Figure 3
3. Unlocked State Data Output Using Serial Data Output
In the LC72130, once an unlocked state occurs, the unlocked state serial data (UL) will not be reset until a data input
(or output) operation is performed. At the data output 1 point in Figure 3, although the VCO frequency has stabilized
(locked), since no data output has been performed since the divisor N was changed the unlocked state data remains in
the unlocked state. As a result, even though the frequency has stabilized (locked), the system remains (from the
standpoint of the data) in the unlocked state.
Therefore, the unlocked state data acquired at data output 1, which occurs immediately after the divisor N was
changed, should be treated as a dummy data output and ignored. The second data output (data output 2) and
following outputs are valid data.
Locked State Determination Flowchart
4. Directly Outputting Unlocked State Data from the DO Pin (Set by the DO pin control data)
Since the locking state (high = locked, low = unlocked) is output directly from the DO pin, the dummy data
processing described in section 3 above is not required. After changing the divisor N, the locking state can be
checked after waiting at least two reference frequency periods.
No. 4973-19/22
LC72130, 72130M
Clock Time Base Usage Notes
The pull-up resistor used on the clock time base output pin (BO1) should be at least 100 kΩ. Also, to prevent chattering
we recommend using a Schmitt input at the controller (microprocessor) that receives this signal.
This is to prevent degrading the VCO C/N characteristics when a loop filter is formed using the built-in low-pass filter
transistor. Since the clock time base output pin and the low-pass filter have a common ground internal to the IC, it is
necessary to minimize the time base output pin current fluctuations and to suppress their influence on the low-pass filter.
Other Items
1. Notes on the Phase Comparator Dead Zone
DZ1
DZ0
Dead zone mode
Charge pump
Dead zone
0
0
DZA
ON/ON
– –0 s
0
1
DZB
ON/ON
–0 s
1
0
DZC
OFF/OFF
+0 s
1
1
DZD
OFF/OFF
+ +0 s
Since correction pulses are output from the charge pump even if the PLL is locked when the charge pump is in the
ON/ON state, the loop can easily become unstable. This point requires special care when designing application
circuits.
The following problems may occur in the ON/ON state.
• Side band generation due to reference frequency leakage
• Side band generation due to both the correction pulse envelope and low frequency leakage
Schemes in which a dead zone is present (OFF/OFF) have good loop stability, but have the problem that acquiring a
high C/N ratio can be difficult. On the other hand, although it is easy to acquire a high C/N ratio with schemes in
which there is no dead zone, it is difficult to achieve high loop stability. Therefore, it can be effective to select DZA
or DZB, which have no dead zone, in applications which require an FM S/R ratio in excess of 90 to 100 dB, or in
which an increased AM stereo pilot margin is desired. On the other hand, we recommend selecting DZC or DZD,
which provide a dead zone, for applications which do not require such a high FM signal-to-noise ratio and in which
either AM stereo is not used or an adequate AM stereo pilot margin can be achieved.
No. 4973-20/22
LC72130, 72130M
Dead Zone
The phase comparator compares fp to a reference frequency (fr) as shown in Figure 4. Although the characteristics of
this circuit (see Figure 5) are such that the output voltage is proportional to the phase difference ø (line A), a region
(the dead zone) in which it is not possible to compare small phase differences occurs in actual ICs due to internal
circuit delays and other factors (line B). A dead zone as small as possible is desirable for products that must provide
a high S/N ratio.
However, since a larger dead zone makes this circuit easier to use, a larger dead zone is appropriate for popularlypriced products. This is because it is possible for RF signals to leak from the mixer to the VCO and modulate the
VCO in popularly-priced products in the presence of strong RF inputs. When the dead zone is narrow, the circuit
outputs correction pulses and this output can further modulate the VCO and generate beat frequencies with the RF
signal.
Figure 4
Figure 5
2. Notes on the FMIN, AMIN, and IFIN Pins
Coupling capacitors must be placed as close as possible to their respective pin. A capacitance of about 100 pF is
desirable. In particular, if a capacitance of 1000 pF or over is used for the IF pin, the time to reach the bias level will
increase and incorrect counting may occur due to the relationship with the wait time.
3. Notes on IF Counting → SD must be used in conjunction with the IF counting time
When using IF counting, always implement IF counting by having the microprocessor determine the presence of the
IF-IC SD (station detect) signal and turn on the IF counter buffer only if the SD signal is present. Schemes in which
auto-searches are performed with only IF counting are not recommended, since they can stop at points where there is
no signal due to leakage output from the IF counter buffer.
4. DO Pin Usage Techniques
In addition to data output mode times, the DO pin can also be used to check for IF counter count completion and for
unlock detection output. Also, an input pin state can be output unchanged through the DO pin and input to the
controller.
5. Power Supply Pins
A capacitor of at least 2000 pF must be inserted between the power supply VDD and VSS pins for noise exclusion.
This capacitor must be placed as close as possible to the VDD and VSS pins.
Pin States After the Power ON Reset
A03484
No. 4973-21/22
LC72130, 72130M
Sample Application System
■ No products described or contained herein are intended for use in surgical implants, life-support systems, aerospace
equipment, nuclear power control systems, vehicles, disaster/crime-prevention equipment and the like, the failure of
which may directly or indirectly cause injury, death or property loss.
■ Anyone purchasing any products described or contained herein for an above-mentioned use shall:
➀ Accept full responsibility and indemnify and defend SANYO ELECTRIC CO., LTD., its affiliates, subsidiaries and
distributors and all their officers and employees, jointly and severally, against any and all claims and litigation and all
damages, cost and expenses associated with such use:
➁ Not impose any responsibility for any fault or negligence which may be cited in any such claim or litigation on
SANYO ELECTRIC CO., LTD., its affiliates, subsidiaries and distributors or any of their officers and employees
jointly or severally.
■ Information (including circuit diagrams and circuit parameters) herein is for example only; it is not guaranteed for
volume production. SANYO believes information herein is accurate and reliable, but no guarantees are made or implied
regarding its use or any infringements of intellectual property rights or other rights of third parties.
This catalog provide information as of November, 1996. Specifications and information herein are subject to
change without notice.
No. 4973-22/22