Minmax MSLU324 Dc/dc converter 1w, high isolation, smd package with industry standard pinout Datasheet

MSLU300 SERIES
DC/DC CONVERTER 1W, High Isolation,SMD-Package
FEATURES
►SMD Package with Industry Standard Pinout
►Small Footprint: 11.0x 16.3 mm (0.43”x 0.64”)
►High 3000VDC I/O-Isolation
►Single and Dual Output Models
►Operating Temp. Range –40°C to +85°C
►High Accuracy of Pin Planarity
►Qualified for lead-free reflow solder process according
IPC/JEDEC J-STD-020D
►Tape & Reel Package available
►3 Year Product Warranty
PRODUCT OVERVIEW
The MINMAX MSLU300 series is a range of 1W DC/DC converters in a SMD- Package featuring high I/O-isolation of 3000VDC.The very small footprint
makes this product the ideal solution for many applications where a voltage has to be isolated i.e for noise reduction, ground loop elimination,in digital
interfaces or where a converted voltage is required.
An excellent efficiency allows an operating temperature range of–40°C to +85°C. With a new package design these converters are fully qualified for the
higher temperature profile used in lead-free reflow solder processes. For automated SMD production lines the product can be supplied in tape& reel
package.
Model Selection Guide
Model
Input
Output
Number
Voltage
Voltage
(Range)
VDC
MSLU301
MSLU302
MSLU304
MSLU305
MSLU306
MSLU308
MSLU309
MSLU311
MSLU312
MSLU314
MSLU315
MSLU316
MSLU318
MSLU319
MSLU321
MSLU322
MSLU324
MSLU325
MSLU326
MSLU328
MSLU329
5
(4.5 ~ 5.5)
12
(10.8 ~ 13.2)
24
(21.6 ~ 26.4)
VDC
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
Output Current
Input Current
Max.
Min.
@Max. Load
@No Load
mA
260
200
84
67
±100
±42
±34
260
200
84
67
±100
±42
±34
260
200
84
67
±100
±42
±34
mA
5
4
2
1.5
±2
±0.8
±0.7
5
4
2
1.5
±2
±0.8
±0.7
5
4
2
1.5
±2
±0.8
±0.7
mA(typ.)
238
267
255
251
267
255
255
98
110
105
103
110
105
106
51
57
53
53
57
53
54
mA(typ.)
30
15
8
Load
Max. capacitive
Regulation
Load
Efficiency
(typ.)
@Max. Load
% (max.)
10
10
7
7
10
7
7
10
8
5
5
8
5
5
10
8
5
5
8
5
5
uF
33
33
4.7
4.7
10#
2.2#
2.2#
33
33
4.7
4.7
10#
2.2#
2.2#
33
33
4.7
4.7
10#
2.2#
2.2#
# For each output
%
72
75
79
80
75
79
80
73
76
80
81
76
80
80
70
73
79
79
73
79
79
Input Specifications
Parameter
Model
5V Input Models
12V Input Models
24V Input Models
5V Input Models
12V Input Models
24V Input Models
Input Voltage Range
Input Surge Voltage (1 sec. max.)
Reverse Polarity Input Current
Input Filter
Internal Power Dissipation
All Models
---
E-mail:[email protected]
2011/12/15 REV:8
Min.
4.5
10.8
21.6
-0.7
-0.7
-0.7
---
Tel:886-6-2923150
Page 1 of 4
Typ.
Max.
5
5.5
12
13.2
24
26.4
--9
--18
--30
--0.3
Internal Capacitor
--550
Unit
VDC
A
mW
MSLU300 SERIES
DC/DC CONVERTER 1W, High Isolation,SMD-Package
Output Specifications
Parameter
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Temperature Coefficient
Short Circuit Protection
Conditions
Dual Output, Balanced Loads
For Vin Change of 1%
Io=20% to 100%
Min.
-----
Typ.
Max.
±0.1
±1.0
±1.2
±1.5
See Model Selection Guide
75
100
--150
--15
±0.01
±0.02
0.5 Second Max.
---------
Over Line, Load & Temp.
Unit
%
%
mV P-P
mV P-P
mV rms
%/℃
General Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
3000
---
---
VDC
I/O Isolation Resistance
500 VDC
10
---
---
GΩ
I/O Isolation Capacitance
100KHz, 1V
---
60
100
pF
50
100
150
KHz
2,000,000
---
---
Hours
I/O Isolation Voltage (rated)
Switching Frequency
MTBF (calculated)
MIL-HDBK-217F@25℃, Ground Benign
Moisture Sensitivity Level (MSL)
IPC/JEDEC J-STD-020D
Level 2
Input Fuse
5V Input Models
500mA Slow-Blow Type
12V Input Models
200mA Slow-Blow Type
24V Input Models
100mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Temperature Range (with Derating)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
Conditions
Ambient
Min.
-40
---50
--Free-Air convection
---
Max.
+85
+90
+125
95
Unit
℃
℃
℃
% rel. H
300
℃
+20%
+20%
+20%
+20%
+15%
+15%
+15%
+15%
+10%
+10%
+10%
Max.
+5%
+5%
Typ.
Vnom
Vnom
Min.
-5%
-5%
-10%
0%
20%
40%
60%
80%
Output Load Current (%)
(3.3V & 5V Output)
E-mail:[email protected]
2011/12/15 REV:8
Tel:886-6-2923150
Page 2 of 4
-10%
100%
Output Voltage(%)
Output Voltage(%)
Output Voltage Tolerance
+10%
Max.
+5%
+5%
Typ.
Vnom
Vnom
Min.
-5%
-5%
-10%
0%
20%
40%
60%
Output Load Current (%)
(All other Output)
80%
-10%
100%
MSLU300 SERIES
DC/DC CONVERTER 1W, High Isolation,SMD-Package
Power Derating Curve
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2
Ripple & Noise measurement bandwidth is 0-20MHz.
3
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
4
All DC/DC converters should be externally fused at the front end for protection.
modules; however they may not meet all specifications listed.
5
Other input and output voltage may be available, please contact factory.
6
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
7
Specifications subject to change without notice.
8
It is not recommended to use water-washing process on SMT units.
Package Specifications
7
1
5
6
3
R
0.
5
2
1.8
[0.07]
5.08 5.08
[0.2] [0.2]
2.54
[0.1]
12.70 [0.50]
2.54 [0.10]
1.7 [0.07]
0~
4
8
11.0 0.2
[0.43 0.008]
12 11 10
0.25 [0.01]
Connecting Pin Patterns
8.0 [0.31]
Mechanical Dimensions
10.6 [0.42]
( Magnification of A )
16.3 [0.64]
0.60 [0.02]
8.0 0.5
[0.31 0.02]
5.08 [0.20]
S SEATING PLANE
►All dimensions in mm (inches)
1.5 0.1
[0.06 0.004]
0.3
[0.01]
7.7 [0.3]
1.0 [0.04]
5.5
[0.22]
5.5
[0.22]
1.5 0.1
[0.06 0.004]
0.1
S
►Tolerance: X.X±0.25 (X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
►Pins ±0.05 (±0.002)
Pin Connections
Pin
Single Output
Dual Output
1
-Vin
-Vin
2
+Vin
+Vin
3
NA
NA
5
-Vout
Common
6
NA
-Vout
7
NA
NA
8
+Vout
+Vout
10
NA
NA
11
NA
NA
12
NA
NA
NA : Not Available for Electrical Connection
E-mail:[email protected]
2011/12/15 REV:8
Tel:886-6-2923150
Page 3 of 4
Physical Characteristics
Case Size
:
16.3x8.0x7.7mm (0.64x0.31x0.30 Inches)
Case Material
:
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Weight
:
2g
MSLU300 SERIES
DC/DC CONVERTER 1W, High Isolation,SMD-Package
Test Configurations
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.33uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between
50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Scope
Cout
Resistive
Load
Cout
Scope
Copper Strip
Design & Feature Considerations
Maximum Capacitive Load
The MSLU300 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <
1.0Ω at 100 KHz) capacitor of a 2.2uF for the 5V input devices, a 1.0uF for the 12V input devices and a 0.47uF for the 24V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 1.0uF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
+
Cout
Load
-Out
+Vin
DC Power
Source
-
+Out
Dual Output
DC / DC
Com.
Converter
-Vin
-Out
Cout
Load
Load
Cout
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2011/12/15 REV:8
Page 4 of 4
Similar pages