MW159 100 Watt Medical Adapter Family • 100-240VAC Universal Input • IPX1 Waterproof • Low Life-Cycle Operation Cost • Desktop Style • Complies with EMI/RFI Regulations • CE compliant (EMC, WEEE, RoHS) • Impact Resistant, Non-vented Polycarbonate Enclosure • Modified and Custom Designs also Available International Safety Standard Approvals Specifications Output Specifications Line and Load Voltage Regulation Environmental Specifications ±1% Thermal Performance Operating Temperature 0° C to 40° C with no Derating Ripple 1% Vp-p max. Cooling Convectional Transient Response ms max. for 50% load 5 change, slew rate of 0.1A/µs Relative Humidity Non-condensing Protection Excluding Cord ycle-by-cycle current C limiting, automatic recovery for overload, short circuit or over temperature protection; active OVP Voltage 100-240VAC nominal Line Frequency 47-63Hz Input Current Protection 5% to 95% Altitude 0-10,000 feet Storage Temp -30° C to +85° C General Specifications Topology ctive PFC and DC-DC A converter Efficiency up to 86% typical Certifications Input Specifications Non-ventilated Enclosure UL60601-1, EN60601-1, IEC60601-1 Hold-up Time >16ms at 120V input, typical 2.0A max. MTBF >200,000 Hours Input fuse, inrush limited Weight 24.4 oz (691g) Case and Dimension 6.6L X 3.2W X 1.6H (in) 167L X 82W X 40H (mm) Case Material Cord 94V-0 Polycarbonate, Black 3.28ft (1m), 2-conductor, 18AWG standard for 18V, 24V output 3.28ft (1m), 4-conductor, 22AWG standard for 12V, 15V output SL Power Electronics Corp • 6050 King Drive • Ventura, CA 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:[email protected] • www.slpower.com MW159 100 Watt Medical Adapter Family For the most current data and application support visit www.slpower.com Output Currents Output Voltage Min Max Ault Part Number Max Watts MW159RA1251F01 12 V 0.00 A 6.66 A 80.0 W MW159RA1551F01 15 V 0.00 A 5.33 A 80.0 W MW159RA1803F01 18 V 0.00 A 5.00 A 90.0 W MW159RA2403F01 24 V 0.00 A 4.20 A 100.0 W Ault Part Number Key MW159 R A 12 51 F 01 Product Family Name Manufacturing Location Type Revision Output Voltage Output Connector Style Input Connector Style Standard Item (other numbers for custom) General Specifications (continued from p. 1) Output Connectors EMI Compliance EN55011 and FCC PART15 conducted and radiated Class B IEC 61000-3-2 Class D IEC 61000-4-2 (ESD), CD level 2 and AD level 3, criterion B IEC 61000-4-3 (RFS), level 2, criterion A IEC 61000-4-4 (EFT), level 2, criterion A IEC 61000-4-5 (Surge), level 3, criterion B Input Connectors IEC320 w/ground C14 (F) IEC320 w/o ground C18 (Q) N. America/ Japan (B) Europe (M) United Kingdom (G) Australian (E) Shaver C8 (N) Optional Features Ault #3, #51 high-retention barrel connector standard arious output cord wire gauges and connector styles available. See Ault V connector style sheets for connector options “Power-on” LED Private label marking SL Power Electronics Corp • 6050 King Drive • Ventura, CA 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:[email protected] • www.slpower.com Data Sheet © 2008 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. Rev.3/20/08