Rectron CMPSH-3S Sot-23 plastic-encapsulate schottky diode Datasheet

RECTRON
SEMICONDUCTOR
CMPSH-3S
TECHNICAL SPECIFICATION
SOT-23 PLASTIC-ENCAPSULATE
SCHOTTKY DIODE
FEATURES
* Power dissipation
P D:
350
mW (Tamb=25OC)
* Forward current
I F:
100
mA
* Reverse voltage
VR:
30
V
* Operating and storage junction temperature range
TJ,Tstg: -55OC to +150OC
SOT-23
MECHANICAL DATA
*
*
*
*
*
Case: Molded plastic
Epoxy: UL 94V-O rate flame retardant
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 0.008 gram
0.055(1.40)
0.047(1.20)
0.006(0.15)
0.003(0.08)
0.043(1.10)
0.035(0.90)
0.020(0.50)
0.012(0.30)
0.004(0.10)
0.000(0.00)
0.100(2.55)
0.089(2.25)
0.020(0.50)
0.012(0.30)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
0.019(2.00)
0.071(1.80)
Ratings at 25 o C ambient temperature unless otherwise specified.
1
0.118(3.00)
3 0.110(2.80)
2
Dimensions in inches and (millimeters)
o
ELECTRICAL CHARACTERISTICS ( @ TA = 25 C unless otherwise noted )
CHARACTERISTICS
Reverse Breakdown Voltage (IR=100mA)
Reverse voltage leakage current (VR=25V)
Reverse voltage leakage current (VR=25V, TA= 100oC)
SYMBOL
MIN
TYP
MAX
V(BR)
30
-
-
V
-
-
500
nA
-
-
100
mA
-
-
0.33
V
-
-
0.45
V
-
-
1
V
Ctot
-
-
8
pF
trr
-
-
5
ns
IR
Forward voltage (IF=2mA)
Forward voltage (IF=15mA)
VF
Forward voltage (IF=100mA)
Diode capacitance (VR=0V, f=1MHz)
Reverse recovery time (IF=IR=10mA, IRR=1.0mA, RL=100W)
Marking
Note 1: "Fully ROHS compliant", "100% Sn plating (Pb-free)".
UNITS
DA5
2006-3
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in