Mean Well LPP-150-3.3 150w single output with pfc function Datasheet

LPP-150
150W Single Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.96
Protections: Short circuit / Overload / Over voltage
Protections:Over temperature(option)
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
SPECIFICATION
MODEL
LPP-150-3.3 LPP-150-5
LPP-150-7.5 LPP-150-12 LPP-150-13.5 LPP-150-15 LPP-150-24 LPP-150-27 LPP-150-48
DC VOLTAGE
3.3V
5V
7.5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
30A
30A
20A
12.5A
11.2A
10A
6.3A
5.6A
3.2A
CURRENT RANGE
0 ~ 30A
0 ~ 30A
0 ~ 20A
0 ~ 12.5A
0 ~ 11.2A
0 ~ 10A
0 ~ 6.3A
0 ~ 5.6A
0 ~ 3.2A
RATED POWER
99W
150W
150W
150W
151.2W
150W
150W
151.2W
153.6W
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
150mVp-p
150mVp-p
250mVp-p
RIPPLE & NOISE (max.) Note.2 100mVp-p
OUTPUT
INPUT
VOLTAGE ADJ. RANGE
3.14 ~ 3.63V 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
2.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
SETUP, RISE TIME
600ms, 30ms at full load
HOLD UP TIME (Typ.)
30ms at full load
VOLTAGE RANGE
85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF 0.96/230VAC
EFFICIENCY(Typ.)
66%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
2.5A/115VAC
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
80%
80%
83%
83%
83%
3.63 ~ 4.45V 5.5 ~ 6.75V 8.25 ~ 10.1V 13.2 ~ 16.2V 14.85 ~ 18.2V 16.5~ 20.25V 26.4 ~ 32.4V 29.7 ~ 36.5V 52.8 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60 with cooling FAN(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A
MTBF
191.8Khrs min. MIL-HDBK-217F (25
222*75*41mm (L*W*H)
0.62Kg; 24pcs/16.6Kg/1.39CUFT
DIMENSION
PACKING
NOTE
79%
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
OTHERS
76%
1.2A/230VAC
OVERLOAD
WORKING TEMP.
WORKING HUMIDITY
(Note 4)
PF 0.98/115VAC at full load
72%
COLD START 40A/230VAC
<3.5mA / 240VAC
OVER VOLTAGE
EMC
120 ~ 370VDC
LEAKAGE CURRENT
PROTECTION
SAFETY &
7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V
2.0%
2.0%
2.0%
2.0%
1.0%
1.0%
1.0%
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:LPP-150-SPEC 2008-03-25
LPP-150
150W Single Output with PFC Function
Mechanical Specification
series
Unit:mm
222
212
FG
5
5
5
4
3
2
1
1
AC FUSE
F5A/250V
65
75
CN1
CN2
12
+V ADJ.
4-
2 max.
41
3.8
AC Input Connector (CN1) : JST B5P-VH or equivalent
Mating Housing
Assignment
AC/L
No Pin
AC/N
FG
Pin No.
1
2,4
3
5
JST VHR
or equivalent
DC Output Connector (CN2) : JST B6P-VH*2 or equivalent
Terminal
Pin No.
1~6
7~12
JST SVH-21T-P1.1
or equivalent
Assignment
-V
+V
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
Block Diagram
PFC fosc : 67KHz
PWM fosc : 134KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
FG
O.L.P.
ACTIVE
START
CIRCUIT
+V
-V
COSTANT CURRENT
LIMITING &
DETECTION CIRCUIT
PWM & PFC
CONTROL
O.V.P.
Derating Curve
Output Derating VS Input Voltage
100
With 18CFM FAN
100
90
80
40
70
With NO FAN
3.3V ~ 7.5V Under 100VAC With No FAN
Must derating to 60% load
LOAD (%)
LOAD (%)
60
80
20
-10
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
85
100
115
135
155
230
264
INPUT VOLTAGE (V) 60Hz
File Name:LPP-150-SPEC 2008-03-25
Similar pages