Rectangular, Multiple-Position Rack/Panel Insulation Displacement Connectors (IDC)
QR/P18 Series
■Overview
The QR/P18 Series of miniature rack/panel connectors is
designed for the complete segmentation of the structure of the
external holder/terminal units of the well-received QR/P Series
of plug-in rectangular rack/panel connectors; furthermore, the
subsequent insertion of the harnessed terminal unit affords a
more efficient harness mounting task. These connectors are
configured with 12, 18, or 24 (insulation displacement
connection) positions in the signal portion, and 4 (crimp)
positions in the power supply portion.
Power supply contact male unit
External holder
Power supply contact
female unit
Power supply
male contacts
Signal contact
female unit
■Features
1. Completely segmented structure of the external
holder/terminal unit
In order to improve the harness mounting task, the connectors are
designed for the complete segmentation of the external holder and the
signal/power supply unit, and the method of subsequently inserting
harnessed products aims to improve the workability of the power
supply/signal section harness as well as the mounting of the set.
Panel
Power supply
female contacts
Signal contact
male unit
2.5 Gbps Eye Pattern Waveform
2. Signal unit
The signal unit uses the highly reliable insulation displacement
connection method. (The wire is AWG #26 and the insulation outside
diameter is 0.88 mm.)
The insulation displacement task can now be used by fitting a special
applicator to a commercially available automatic insulation
displacement machine, or a manual press can also be selected.
3. Power supply portion
The power supply terminals permit the use of a crimp harness
using wire of AWG #16 to 18 (and insulation outside diameter
of 2.1 to 2.2 mm), and can accommodate a maximum of 12 A.
4. Sequenced structure
Connectors possess two sequenced contacts in the signal
male unit and one sequenced contact in the power supply
female unit making them perfect in terms of safety too.
5. Panel installation
Installation to a panel uses a single-action method on the
anchored side and a floating screw structure on the floating side
which permits smooth insertion and disconnection without forcing.
6. RoHS compliant
All components and materials comply with the requirements of the
EU Directive 2002/95/EC.
*A portion of this series is suitably constructed for high-speed differential
transfer, and using a suitable cable, transfer of 2.5Gbps per pair is possible.
2.5Gbps
Scale
AWG28 2m
X : 100psec/div
Y : 100V/div
■Applications
PPC, transmitting and receiving devices,
data communications equipment, vending
machines, measuring instruments, factory
automation equipment, and other highspeed transfer applications, etc.
2007.4
1
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
■Product Specifications
125 V AC (Signal contacts)
-40ç to +105ç
300V AC (Power contacts)
Operating temperature range
1A (Signal contacts)
(Note 1)
12A (Power contacts)
Voltage rating
Ratings
Current rating
Item
1. Contact resistance
2. Insulation resistance
3. Withstanding Voltage
4. Durability (mating /
un-mating)
Specification
50mø max. (Signal contacts) (Note 2)
10mø max. (Power contacts) (Note 2)
1000Mø min. (Signal contacts)
5000Mø min. (Power contacts)
No flashover or insulation breakdown.
Contact resistance: 70mø max. (Signal contacts)
20mø max. (Power contacts)
Conditions
100 mA
500 V DC
500 V AC / one minute
3000 cycles
Frequency: 10 to 55 Hz, single amplitude of 0.75 mm,
2 hours in each of the 3 axis.
Acceleration of 490 m/s2, 11 ms duration, sine half-wave
6. Shock
waveform, 3 cycles in each of the 3 axis
Contact resistance: 70mø max. (Signal contacts) Temperature: -55ç→+5ç to +35ç→+105ç→+5ç to +35ç
20mø max. (Power contacts) Time: 30→5→30→5 (Minutes)
7. Temperature cycle
5 cycles
No damage, cracks, or parts dislocation.
Insulation resistance: 100Mø min. (Signal contacts, state)
8. Humidity
3000Mø min. (Power contacts, state) 96 hours at 40ç and RH 90% to 95%
(Steady state)
No damage, cracks, or parts dislocation.
No corrosions.
9. Salt mist
5% salt water solution for 48 hours
5. Vibration
No electrical discontinuity of 10µs or more.
No damage, cracks, or parts dislocation.
Note1: Includes temperature rise caused by current flow.
Note2: Excludes wire conductor resistance.
■Materials
Components
Insulator
Insulator
Female contacts
Male contacts
Insulator
Female contacts
Male contacts
Female contacts
Male contacts
Products
External holder
Signal contact unit
Power contact unit
Power supply contacts
Material
PBT
PA
Phosphor bronze
Phosphor bronze
PBT
Phosphor bronze
Phosphor bronze
Copper alloy
Copper alloy
Finish
----------------------------Gold plated
Gold plated
--------------Gold plated
Gold plated
Gold plated + Tin copper plated
Gold plated + Tin copper plated
■Function Diagram
●Power supply/signal combination type
QR/P18-Pπ4S
QR/P18-Sπ4S-π
QR/P17-PCA-π11(50) QR/P18-4P-C
QR/P18-4S-C
QR/P18-πSπ
QR/P18-πPπ
●Signal type
QR/P18-Sπ
QR/P18-πSπ
2
QR/P18-Pπ
QR/P18-πPπ
QR/P17-SCA-π11(50)
Remarks
UL94V-0
UL94V-0
---------------------------UL94V-0
-----------------------------------------------------
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
■Ordering information
●External holder.
QR / P18 - S A 4 P - A
1
2
3
1
Series name
2
Signal contact type
3
Number of signal contact of external holder
S: Female contact
4
5
6
4
Number of power contact
5
Power contact type
6
Applicable panel thickness
P: Male contact
S: Female contact
P: Male contact
A: 12 pos. (Contact pitch 1.5mm)
A: 2mm
B: 18 pos. (Contact pitch 1.5mm)
B: 1.5mm
C: 24 pos. (Contact pitch 1.5mm)
●Signal contact termination block
QR / P18 - 12 S A
1
1
Series name
2
Number of signal contact
3
Signal contact type
2
3
4
4
Number of signal contact of signal contact
termination block
S: Female contact
A: 12 pos. (Contact pitch 1.5mm)
P: Male contact
B: 18 pos. (Contact pitch 1.5mm)
C: 24 pos. (Contact pitch 1.5mm)
●Power contact insert
QR / P18 - 4 P - C
1
1
Series name
2
Number of power contact
3
Power contact type
2
3
4
4
Connector type
C: Crimp housing
S: Female contact
P: Male contact
●Power contact
QR / P17 - PC A - 1 1 1
1
1
Series name
2
Power contact type
3
Applicable wire style A: UL1015
2
3
4
5
6
4
Packaging
5
Applicable wire
1: AWG#16 to 18
6
Contact plating
1: Gold plated
PC: Male crimp contact
SC: Female crimp contact
1: Pack packaging
2: Reel packaging
3
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
■External holder
Mated condition (Shown for reference)
Panel
Panel
QR/P18-Sπ4P-A
QR/P18-Pπ4S
QR/P15-SCREW
2
6.15
23
26.5
2
2.5
5.1
7.4
29
Note: Establish panel mounting so that the mating gap
dimensions of the power supply side and the
signal side are 1.5 mm or less.
●Female power contact, male signal contact type
A
B
Panel cutout
Applicable panel thickness: 2.0mm
0 .2
5 -0
20.7 +0.1
0
(2)
0.
C±0.1
19.8 +0.1
0
14.75±0.05
10.5
3 23
32.65
R0
D+0.1
0
18.8
2-
26.5
R
6-
.2
+0 0
.3
2-M3∞0.5
10.5±0.1
13.9 +0.1
Die roll side should be
0
connector mating side.
Number of contacts
Signal
Power
QR/P18-PA4S
CL221-0293-8
12
4
QR/P18-PB4S
CL221-0313-3
18
4
QR/P18-PC4S
CL221-0297-9
24
4
Panel attachment screw (QR/P15-SCREW CL221-0251-8) is optional.
Part number
4
CL No.
A
B
C
D
RoHS
54.65
58.65
63.15
46.25
50.25
54.75
46.25
50.25
54.75
27.2
31.2
35.7
YES
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
●Male power contact, female signal contact type
A
B
Panel cutout
Applicable panel thickness: 2.0mm
0 .2
5 -0
20.7 +0.1
0
(2)
0.
C±0.1
19.8 +0.1
0
14.75±0.05
10.5
3 23
32.65
R0
D+0.1
0
18.8
2-
26.5
R
6-
.2
+0 0
.3
2-M3∞0.5
10.5±0.1
13.9 +0.1
Die roll side should be
0
connector mating side.
Part number
CL No.
QR/P18-SA4P-A
QR/P18-SB4P-A
QR/P18-SC4P-A
CL221-0294-0
CL221-0315-9
CL221-0298-1
Number of contacts
Signal
Power
12
4
18
4
24
4
A
B
C
D
RoHS
43.85
47.85
52.35
37.9
41.9
46.4
27.25
31.25
35.75
17.3
21.3
25.8
YES
5
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
■External holder (Signal type)
Mated condition (Shown for reference)
QR/P18-Sπ-B
QR/P18-Pπ
QR/P15-SCREW
Panel
1.5
1.5
15
3
2.5
17.5
5.1
7.4
Note: Establish panel mounting so that the mating gap
dimensions of the power supply side and the
signal side are 1.5 mm or less.
●Male signal contact type
Panel cutout
R0
.3m
in.
R
5ax
5m
0.
3
15
18
Applicable panel thickness: 1.5mm
C
(15)
+0.2
0
t=1.5
13
4.7
D+0.2
0
E±0.1
Die roll side should be
connector mating side.
B
A
Number of contacts
A
Signal
QR/P18-PB
CL221-0309-6
18
37.7
QR/P18-PC
CL221-0311-8
24
42.2
Panel attachment screw (QR/P15-SCREW CL221-0251-8) is optional.
Part number
6
4.7±0.1
14.8
+0.2
0
0
2.2 -0.2
.
2-M3∞0.5
CL No.
B
C
D
E
RoHS
29.5
34.0
27.0
31.5
23.5
28.0
29.5
34.0
YES
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
●Female signal contact type
Panel cutout
R0
.3m
in.
ax
5m
0.
R
5-
3
15
18
Applicable panel thickness: 1.5mm
C
(15)
+0.2
0
t=1.5
13
4.7
4.7±0.1
14.8
+0.2
0
0
2.2 -0.2
.
2-M3∞0.5
D+0.2
0
E±0.1
Die roll side should be
connector mating side.
B
A
Part number
CL No.
QR/P18-SB-B
QR/P18-SC-B
CL221-0310-5
CL221-0312-0
Number of contacts
Signal
18
24
A
B
C
D
RoHS
28.05
32.55
25.1
29.6
13.00
15.25
07.3
11.8
YES
7
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
■Signal contact termination block
●Male, contact pitch 1.5mm
15
A
B
Sequence contact
Sequence contact
Number of
contacts
QR/P18-12PA
CL221-0291-2
12
QR/P18-18PB
CL221-0285-0
18
QR/P18-24PC
CL221-0295-3
24
Adscable cable: AWG#26, insulator diameter 0.88mm
Part number
CL No.
A
B
RoHS
13.5
17.5
22.0
14.0
18.0
22.5
YES
B
A
●Female, contact pitch 1.5mm
15
Number of
contacts
QR/P18-12SA
12
CL221-0292-5
18
QR/P18-18SB
CL221-0286-2
QR/P18-24SC
CL221-0296-6
24
Applicable cable: AWG#26, insulator diameter 0.88mm
Part number
8
CL No.
A
B
RoHS
13.5
17.5
22.0
14.0
18.0
22.5
YES
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
■Power contact insert
●Male
15.9
31.1
17.9
Part number
CL No.
RoHS
QR/P18-4P-C
CL221-0316-1
YES
●Female
Sequence contact(No.4)
13.5
27.7
16.2
Part number
CL No.
RoHS
QR/P18-4S-C
CL221-0314-6
YES
9
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
■Power contact
●Male contact
28.5
3
Applicable
wire size
16-18
Part number
CL No.
Applicable cable
QR/P17-PCA-111(50)
CL221-0265-2-50
AWG16~18 UL1015
QR/P17-PCA-211(50)
CL221-0263-7-50
AWG16~18 UL1015
Applicable cable: AWG#16 to 18, insulator diameter 2.1mm to 3.2mm
Packaging
Q'ty
RoHS
Bag
Reel
100
3000
YES
●Female contact
4
Part number
CL No.
Applicable cable
CL221-0264-0-50
AWG16~18 UL1015
QR/P17-SCA-111(50)
CL221-0262-4-50
AWG16~18 UL1015
QR/P17-SCA-211(50)
Applicable cable: AWG#16 to 18, insulator diameter 2.1mm to 3.2mm
10
16-18
18.3
Applicable wire size
Packaging
Q'ty
RoHS
Bag
Reel
100
3000
YES
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
BTools
●Signal contact termination block IDC tool
Type
Part number
Hand press for 12 pos.
QR/P18-12/IDCR-MP
Hand press for 18 pos.
QR/P18-18/IDCR-MP
Hand press for 24 pos.
QR/P18-24/IDCR-MP
Automatic IDC applicator for male
signal contact
Automatic IDC applicator for female
signal contact
Applicable connector
QR/P18-12PA
QR/P18-12SA
QR/P18-18PB
QR/P18-18SB
QR/P18-24PC
QR/P18-24SC
QR/P18-12PA
2957-1000
QR/P18-18PB
QR/P18-24PC
QR/P18-12SA
2957-1500
QR/P18-18SB
QR/P18-24SC
Automatic IDC machine (Murata kogyo co., Ltd., P/N MS-01) is available.
●Power contact crimp tool
Applicable contact
Type
Part number
Hand tool
HT104/QR/P17-1
Applicable for automatic crimp
AP105-QR/P17-1
QR/P17-PCA-211(50)
machine
AP105-QR/P17-1
QR/P17-SCA-211(50)
Automatic crimp machine
CM-105
QR/P17-PCA-111(50)
QR/P17-SCA-111(50)
QR/P17-PCA-211(50)
QR/P17-SCA-211(50)
QR/P17-PCA-111(50)
Extraction tool
QR/P17-TC
QR/P17-SCA-111(50)
QR/P17-PCA-211(50)
QR/P17-SCA-211(50)
11
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
■Inspection After Cable Wiring
●Signal contact unit
Signal contact unit (male)
Signal contact unit (female)
Cable
Cable
A
A
B
B
0~0.5
Cable end position
A-A
B-B
2.55±0.1
2.55±0.1
2.08±0.1
2.08±0.1
0~0.5
Cable end position
Insulation displacement height
Insulation height
Insulation displacement height
Insulation height
(1) After wiring the cable, examine the cable end position, the insulation displacement height, and the insulation height.
(2) In examining the insulation displacement height and the insulation height, use a measurement pin having a tip of 0.5 mm diameter.
(3) For information about the detailed inspection method, please request the "Inspection Standards Manual" from Hirose Electric.
(4) The inspection method of the diagrams is for cable with AWG #26 wire and an insulation outside diameter of 0.88 mm.
●Power supply contacts
Male contact
Cable
Female contact
Cable
Spring
3.6 mm or greater
1.6 mm or greater
Spring
Before inserting the power supply contacts into the power supply terminal unit, check that the spring portion illustrated in the
diagram is not misshapen.
When the spring portion is less than the dimensions indicated in the diagram, the spring could pull out from the power supply
terminal unit; therefore, the specified dimensions should be maintained.
®
12
5-23,OSAKI 5-CHOME,SHINAGAWA-KU,TOKYO 141-8587,JAPAN
PHONE: 81-3-3491-9741, FAX: 81-3-3493-2933
http://www.hirose.com
http://www.hirose-connectors.com
The contents of this catalog are current as of date of publication. Contents are subject to change without notice for the purpose of improvements.
Similar pages