RUILON GXP34 2-electrode spark gap Datasheet

ELECTRONICS
2-electrode
Spark
Gap
GXP Series
Circuit Protection
System
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.
2-electrode Spark Gap - GXP Series
The GXP Series of 2-electrode spark gaps are gas discharge tubes,
hermetically sealed in a glass/metal envelope. Tubes with a DC breakdown
voltage in the range 250 V to 10 kV are available. This is signified by a
numeral or numerals following the type letters and is expressed in hundreds
of volts, e.g. GXP60 has a 6kV DC breakdown voltage.
Typical Applications
1. Single-shot pulse generators
2. Turbine engine ignition circuits
3. Medical lithotripsy
4. High energy switches
Electrical And Physical Characteristics
All ratings given in this data sheet a reab solute, nonsimultaneous ratings. It is the equipment designer’s responsibility to ensure
that they are not exceeded.The spark gap life depends on circuit conditions such as peak discharge current and duration,
charge transfer per discharge and the
repetition rate.
Charge transfer, single discharge
(8/20 ms waveshape)
0.5C max
Cumulative charge transfer
6000C at 0.81mC
per discharge at 1 Hz
Operating temperature
-55 to +125°C
Mechanical shock, half-sine
(to B.S. 2011 test Ea)
40g for 4ms
Mounting
screw mounted
Radioactivity
tritium (3H), 5.44 MBq
(147 mCi) max per device
Circuit Protection
System
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.
Page:1
2-electrode Spark Gap - GXP Series
Electriacl Characteristics
Part No.
DC
Spark-over
Voltage
Max.Impulse
Discharge
Current (8/20μs)
MAX Energy Level
Minimum
Insulation
Resistance
MaximumC
apacitance
(V)
(KA)
(J)
(MΩ)
pF
W
GXP05
500
30
60
100
5
60
GXP10
1000
30
60
100
5
60
GXP12
1200
30
60
100
5
60
GXP14
1400
30
60
100
5
60
GXP15
1500
30
60
100
5
60
GXP16
1600
30
60
100
5
60
GXP18
1800
30
60
100
5
60
GXP20
2000
30
60
100
5
60
GXP21
2100
30
60
100
5
60
GXP22
2200
30
60
100
5
60
GXP23
2300
30
60
100
5
60
GXP24
2400
30
60
100
5
60
GXP25
2500
30
60
100
5
60
GXP26
2600
30
60
100
5
60
GXP27
2700
30
60
100
5
60
GXP28
2800
30
60
100
5
60
GXP29
2900
30
60
100
5
60
GXP30
3000
30
60
100
5
60
GXP31
3100
30
60
100
5
60
GXP32
3200
30
60
100
5
60
GXP33
3300
30
60
100
5
60
GXP34
3400
30
60
100
5
60
GXP35
3500
30
60
100
5
60
GXP40
4000
30
60
100
5
60
GXP45
4500
30
60
100
5
60
GXP50
5000
30
60
100
5
60
GXP55
5500
30
60
100
5
60
GXP60
6000
30
60
100
5
60
GXP65
6500
30
60
100
5
60
GXP70
7000
30
60
100
5
60
GXP75
7500
30
60
100
5
60
GXP80
8000
30
60
100
5
60
GXP85
8500
30
60
100
5
60
GXP90
9000
30
60
100
5
60
GXP95
9500
30
60
100
5
60
GXP100
10000
30
60
100
5
60
GXP105
10500
30
60
100
5
60
GXP110
11000
30
60
100
5
60
GXP115
11500
30
60
100
5
60
GXP120
12000
30
60
100
5
60
Circuit Protection
System
Maximum power
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.
Page:2
2-electrode Spark Gap - GXP Series
OUTLINE (All dimensions in millimetres)
HOLE THREADED M3 x 5.0 MIN DEEP
CONTACT CAP
Φ9.5 ± 0.5
Φ29.0
MAX
Φ29.0
MAX
42.0
MAX
42.0
MAX
64.0
MAX
Warehouse Storage Conditions of Products
· Storage Conditions:
1. Storage Temperature: -10°C~+40°C
2. Relative Humidity:≤75%RH
3. Keep away from corrosive atmosphere and sunlight.
· Period of Storage: 1 year
Circuit Protection
System
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.
Page:3
RuiLongYuan Electronics Co., Ltd.
· Reproducing and modifying information of the document is prohibited without permission from
Ruilongyuan International Inc.
· Ruilongyuan International Inc. reserves the rights to make changes of the content herein the document anytime
without notification. Please refer to our website for the latest document.
· Ruilongyuan International Inc. disclaims any and all liability arising out of the application or use of any product
including damages incidentally and consequentially occurred.
· Ruilongyuan International Inc. does not assume any and all implied warranties, including warranties of fitness
for particular purpose, non-infringement and merchantability.
· Applications shown on the herein document are examples of standard use and operation. Customers are responsible
in comprehending the suitable use in particular applications.Ruilongyuan International Inc. makes no representation or
warranty that such applications will be suitable for the specifed use without further testing or modifcation.
· The products shown herein are not designed and authorized for equipments requiring high level of reliability or relating to
human life and for any applications concerning life-saving or life-sustaining, such as medical instruments, transportation
equipment,aerospace machinery et cetera. Customers using or selling these products for use in such applications do so at
their own risk and agree to fullyindemnify Ruilongyuan International Inc. for any damages resulting from such improper use or
sale.
Tel: +86-755-8290 8296
Circuit Protection
System
Fax: +86-755-8290 8002
E-mail: [email protected]
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.