Red Lion ANT-G30B108111 Model xchspa â hspa cellular modem option card for data station plus, modular controller and ptv Datasheet

Bulletin No. XCHSPA-B
Drawing No. LP0966
Released 04/15
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL XCHSPA – HSPA+ CELLULAR MODEM OPTION CARD FOR DATA
STATION PLUS, MODULAR CONTROLLER AND PTV
zz SUPPORTS HSPA+ CELLULAR DATA CONNECTIVITY WITH FALL
BACK TO 3G AND 2G
zz UP TO 21 MBPS DOWNLINK/5.76 MBPS UPLINK SPEEDS
zz CONFIGURED USING CRIMSON® 3.0 SOFTWARE
zz FOR INSTALLATION WITH A DATA STATION PLUS, A MODULAR
CONTROLLER MASTER OR A ProducTVity STATION (PTV)
zz INSTALLATION AND CONNECTION HARDWARE ARE INCLUDED
WITH CARD
GENERAL DESCRIPTION
SAFETY SUMMARY
The XCHSPA option card allows the user to add HSPA+ cellular modem
capability to their Data Station Plus, Modular Controller Master or PTV. The
cellular standard adopted in this option card is HSPA+ with fallback capability
to 3G and 2G. It can get speeds up to 21 Mbps downlink and 5.76 Mbps uplink.
It’s built upon the GSM standard and widely available throughout the world.
HSPA+ can be used for services such as Wireless Application Protocol (WAP)
access, Short Message Service (SMS), and for Internet connectivity.
The XCHSPA option card is penta-band, allowing it to work in frequencies
across the Americas, Europe and Asia. US and Canada work in the 850/1900
MHz bands, while Europe, Middle East, Africa and most of Asia work in the
900/1700/2100 MHz HSPA+ frequencies.
The XCHSPA requires the addition of a SIM (Subscriber Identity Module)
card, which is inserted into the holder prior to installation of the XCHSPA card.
The SIM card securely stores the service-subscriber key (IMSI) used to identify
a subscriber, and is used to connect to the network to obtain an IP address from
the provider.
The XCHSPA communication card is easily installed by removing the blank
expansion port cover of your Data Station Plus, Modular Controller Master or
PTV and plugging the XCHSPA card into the expansion port. Configuration is
simple using Red Lion’s free Crimson® 3.0 software.
All safety related regulations, local codes and instructions that appear in the
literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Do not use the controller to directly command motors, valves, or other
actuators not equipped with safeguards. To do so can be potentially harmful to
persons or equipment in the event of a fault to the controller.
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
SPECIFICATIONS
1. POWER REQUIREMENTS:
HSPA+ Mode: During continuous active webserver traffic
Instantaneous maximum: 24 V @ 300 mA
Average:
24 V @ 200 mA
GPRS Mode:
Instantaneous maximum: 24 V @ 650 mA (1.1 msec every 4.6 msec)
Average:
24 V @ 275 mA
Power is supplied to the option card from the main board of the Modular
Controller Master, Data Station Plus or PTV.
2. LINK STATUS LEDs:
Link Status - Link Status LED shows cellular link condition.
3. COMMUNICATIONS:
Isolation from XCHSPA Antenna connector to Modular Controller
Master, Data Station Plus or PTV: 500 VDC for 1 minute.
2. ANTENNA CONNECTOR:
SMA Female connector requires:
50 Ohm antenna with SMA male connector
Penta-band HSPA+ antenna (850/900/1700/1900/2100 MHz) for global
support.
Dual-band (850/1900 MHz) antenna for US and Canada only
Dual band (900/2100 MHz) for Europe only
Voltage Standing Wave Ratio (VSWR) should not exceed 2.0:1
The antenna cable should be 50Ω impedance, RG178/U or RG174/U type
and be able to connect to the RSMA (Male) jack bulkhead. The antenna
could be horizontal, vertical or right angled. Longer antenna cable would
equate to signal loss. This device is intended for connection to an antenna
mounted within the building or a UL certified enclosure suitably rated for
application.
CONTENTS OF PACKAGE
- XCHSPA option card
- This hardware bulletin
ORDERING INFORMATION
MODEL NO.
XCHSPA
DESCRIPTION
GSM/HSPA+ Modem Option Card
PART NUMBER
1
2G/3G 3" hinged antenna
ANT
1
XCHSPA00
ANT-TG090113
2G/3G/4G LTE low profile direct
permanent mount antenna, IP67 rated
ANT-G30B108111
2G/3G 4.5" whip magnetic mount antenna,
IP65 rated
ANT-GA107201111
2G/3G low profile direct permanent mount
antenna, IP65 rated
ANT-G21B301111
Antenna is NOT included with the card. Must be purchased separately if
needed.
1
3. CERTIFICATIONS AND COMPLIANCES:
Refer to main unit manual or “Agency Approvals” section of Red Lion’s
website for agency certifications.
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for
Measurement, Control and Laboratory use.
Reference Data Station Plus, Modular Controller Master or PTV unit for
EMC specifications
The XCHSPA option card has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC rules.
4. ENVIRONMENTAL CONDITIONS:
Refer to the specifications of the Data Station Plus, Modular Controller
Master or PTV you are installing this card in. * See Thermal Performance
and Consideration section when installing in DSP extended
temperature units.
5. CONSTRUCTION: For indoor use only. Installation Category II, Pollution
Degree 2.
6. INSTALLATION REQUIREMENTS: See “Installing the XCHSPA Option
card” for more details.
7. WEIGHT: 3.0 oz (85.05 g)
EMC INSTALLATION GUIDELINES
effective. The following EMI suppression devices (or equivalent) are
recommended:
Fair-Rite part number 0443167251 (RLC part number FCOR0000)
Line Filters for input power cables:
Schaffner # FN2010-1/07 (Red Lion Controls # LFIL0000)
6. To protect relay contacts that control inductive loads and to minimize radiated
and conducted noise (EMI), some type of contact protection network is
normally installed across the load, the contacts or both. The most effective
location is across the load.
a. Using a snubber, which is a resistor-capacitor (RC) network or metal oxide
varistor (MOV) across an AC inductive load is very effective at reducing
EMI and increasing relay contact life.
b. If a DC inductive load (such as a DC relay coil) is controlled by a transistor
switch, care must be taken not to exceed the breakdown voltage of the
transistor when the load is switched. One of the most effective ways is to
place a diode across the inductive load. Most RLC products with solid state
outputs have internal zener diode protection. However external diode
protection at the load is always a good design practice to limit EMI.
Although the use of a snubber or varistor could be used.
RLC part numbers: Snubber: SNUB0000
Varistor: ILS11500 or ILS23000
7. Care should be taken when connecting input and output devices to the
instrument. When a separate input and output common is provided, they
should not be mixed. Therefore a sensor common should NOT be connected
to an output common. This would cause EMI on the sensitive input common,
which could affect the instrument’s operation.
Although Red Lion Controls Products are designed with a high degree of
immunity to Electromagnetic Interference (EMI), proper installation and wiring
methods must be followed to ensure compatibility in each application. The type
of the electrical noise, source or coupling method into a unit may be different
for various installations. Cable length, routing, and shield termination are very
important and can mean the difference between a successful or troublesome
installation. Listed are some EMI guidelines for a successful installation in an
industrial environment.
1. A unit should be mounted in a metal enclosure, which is properly connected
to protective earth.
2. Use shielded cables for all Signal and Control inputs. The shield connection
should be made as short as possible. The connection point for the shield
depends somewhat upon the application. Listed below are the recommended
methods of connecting the shield, in order of their effectiveness.
a. Connect the shield to earth ground (protective earth) at one end where the
unit is mounted.
b. Connect the shield to earth ground at both ends of the cable, usually when
the noise source frequency is over 1 MHz.
3. Never run Signal or Control cables in the same conduit or raceway with AC
power lines, conductors, feeding motors, solenoids, SCR controls, and
heaters, etc. The cables should be run through metal conduit that is properly
grounded. This is especially useful in applications where cable runs are long
and portable two-way radios are used in close proximity or if the installation
is near a commercial radio transmitter. Also, Signal or Control cables within
an enclosure should be routed as far away as possible from contactors, control
relays, transformers, and other noisy components.
4. Long cable runs are more susceptible to EMI pickup than short cable runs.
5. In extremely high EMI environments, the use of external EMI suppression
devices such as Ferrite Suppression Cores for signal and control cables is
Thermal Performance
Visit RLC’s web site at http://www.redlion.net/emi for more information on
EMI guidelines, Safety and CE issues as they relate to Red Lion Controls
products.
and
This option card is rated for operation from -20°C to +70°C (See below for
thermal de-ratings) when the proper thermal considerations are taken into
account. Please refer to the following information to maximize the performance
of this option card when it’s operated under extreme temperatures.
Considerations
• Reduced wireless performance may occur when operating above +60 °C in
continuous webserver mode of operation with refresh rate set at 0 seconds.
• Running at temperatures above 60 °C for extended periods of time may
reduce the performance and longevity of the unit.
High Temperature Operating Conditions:
If your wireless communications is atypically high or frequent, then the
maximum ambient operating temperature may be reduced. The wireless circuit(s)
in this option card may shutdown to protect from permanent damage when the
internal circuitry temperature becomes extreme.
This option card has many modes of operation which can cause the power
consumption and corresponding heat dissipation to vary greatly. This factor,
along with others, can affect the performance and longevity of the unit.
The maximum ambient temperature rating is further defined as follows:
• 60 °C maximum for continuous data usage and webserver operation with
refresh rate set at 0 seconds in Crimson:
• 65 °C maximum for continuous webserver operation with refresh rate set
to 10 seconds in Crimson
• 70 °C maximum for continuous web server operation with a refresh rate
set to 30 seconds in Crimson
• 70 °C maximum for SMS mode of operation (sending and receiving text
messages). These units may also be operated at 70 °C if data usage is brief
and intermittent (e.g. downloading a 100 kB log file once an hour).
• For best performance and longevity, try to maintain an ambient air
temperature less than 60 °C.
• The ambient temperature is defined as the temperature of the air
immediately surrounding the unit.
2
Installing
the
XCHSPA Option Card
The first step is to buy a SIM Card from one of the GSM/HSPA+ providers
and insert it into the SIM Card slot of the option card. The SIM Card slot is the
rectangular slot on top of the GSM/HSPA+ Cellular Modem in the XCHSPA
option card as shown in Figure 1. See SIM Card details in the Software/Unit
Operation Section for more details.
1. Remove power from the unit.
2. Insert a flat-bladed screwdriver into the slot at the top of the expansion port
cover. Gently apply pressure on the screwdriver in an upward direction until
the expansion port cover disengages from the unit as shown in Figure 2.
3. Verify that the option card knobs are in the “unlocked” position as shown in
Figure 3.
4. Carefully insert the option card into the expansion port opening while
aligning the card-edge connector on the option card with the main board's
header, as shown in Figure 4. Once aligned, gently press on the front of the
card until it is flush with the front of the case.
5. Turn the option card knobs to the locked position as shown in Figure 5.
Caution: The expansion and main circuit boards contain static
sensitive components. Before handling the cards, discharge static
charges from your body by touching a grounded bare metal object.
Ideally, handle the cards at a static controlled clean workstation.
Also, handle the cards by the edges only. Dirt, oil, or other
contaminants that may contact the cards can adversely affect circuit
operation.
Warning: Risk of Danger: Be sure to remove all power before
removing the expansion port cover.
XCHSPA
LINK
STATUS
SIM CARD ORIENTATION
A
M
Figure 1
Figure 2
Figure 3
XCHSPA
LINK
STATUS
THE OPTION CARD LABEL
Place the option card label on your outer plastic cover
of the Data Station Plus, Modular Controller Master or
PTV. The label displays the FCC ID of the particular
modem being used in the XCHSPA option card.
XCHSPA
LINK
STATUS
Figure 5
Figure 4
3
POWER SUPPLY REQUIREMENTS
NEW AND EXISTING INSTALLATIONS
The XCHSPA option card draws all of its power from the main board of the
Data Station Plus, Modular Controller Master or PTV. The specifications of the
Modular Controller Master, Data Station Plus or PTV account for the power
needs of an option card.
Software/Unit Operation
CRIMSON SOFTWARE
Crimson® 3.0 software is available as a free download from www.redlion.net
or it can be purchased on a CD, see “Ordering Information” for part number.
The latest version of the software is always available from the web site, and
updating your copy is free.
LED
LINK STATUS – MODEM STATUS LED
The Link Status LED is a green LED that provides information regarding the
state of the modem module’s cellular connection. The status is described below.
OFF
No power to the unit
ON
Powered and not registered on the cellular
network.
BLINKING
Powered and registered on the cellular network.
SIM CARD INSTALLATION & DETAILS
A SIM Card with data plan enabled has to be installed on the XCHSPA option
card before installing the option card in the Data Station Plus, Modular
Controller Master or PTV. Please contact your GSM/HSPA+ cellular network
provider on setting up an account and data plan. The carrier should provide you
with a SIM card to insert into the module, along with the APN, username, and
password for data connectivity.
TROUBLESHOOTING YOUR XCHSPA OPTION
CARD
If for any reason you have trouble operating, connecting, or simply have
questions concerning your new XCHSPA option card, contact Red Lion’s
technical support. For contact information, refer to the back page of this bulletin
for phone and fax numbers.
EMAIL: [email protected]
Web Site: http://www.redlion.net
CONFIGURING A XCHSPA OPTION CARD
The XCHSPA option card is configured using Crimson (3.0 or later)
software. After choosing the appropriate Cellular modem option card, it is set
up as a PPP Modem client (choosing HSPA+ modem in the drop down box
selection), PPP Modem Server or SMS via HSPA+ Modem.
Additional information can be found in your Data Station Plus, Modular
Controller Master or PTV hardware bulletin and the Crimson User Manual.
LIMITED WARRANTY
The Company warrants the products it manufactures against defects in materials and workmanship
for a period limited to two years from the date of shipment, provided the products have been stored,
handled, installed, and used under proper conditions. The Company’s liability under this limited
warranty shall extend only to the repair or replacement of a defective product, at The Company’s
option. The Company disclaims all liability for any affirmation, promise or representation with
respect to the products.
The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against
damages, claims, and expenses arising out of subsequent sales of RLC products or products
containing components manufactured by RLC and based upon personal injuries, deaths, property
damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be
to any extent liable, including without limitation penalties imposed by the Consumer Product Safety
Act (P.L. 92-573) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty
Act (P.L. 93-637), as now in effect or as amended hereafter.
No warranties expressed or implied are created with respect to The Company’s products except
those expressly contained herein. The Customer acknowledges the disclaimers and limitations
contained herein and relies on no other warranties or affirmations.
Red Lion Controls
Headquarters
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
Red Lion Controls
Europe
Softwareweg 9
NL - 3821 BN Amersfoort
Tel +31 (0) 334 723 225
Fax +31 (0) 334 893 793
Red Lion Controls
India
201-B, 2nd Floor, Park Centra
Opp 32 Mile Stone, Sector-30
Gurgaon-122002 Haryana, India
Tel +91 984 487 0503
Red Lion Controls
China
Unit 1102, XinMao Plaza
Building 9, No.99 Tianzhou Road
ShangHai, P.R. China 200223
Tel +86 21 6113 3688
Fax +86 21 6113 3683
Similar pages