MPD MPM30T5312CM Mpm-30cm sery Datasheet

MPM-30CM Series
Chassis Mount, 30W
Single, Dual & Triple Out
AC/DC Power Supplies
Key Features:
• 30W Output Power
• Universal 85-265 VAC Input
• EN 60950 Approved (UL)
• Single, Dual & Triple Outputs
• Meets EN 55022 B
• Meets IEC Safety Class II
• Chassis Mount Case
PCB Mount Models
& DIN Rail Mount
Option Available!
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
Conditions
Inrush Current
EMI
Min.
Typ.
Max.
85
265
47
440
See Model Selection Guide
115 VAC
20.0
230 VAC
40.0
Meets CISPR Pub. 22/FCC Class B
Units
VAC
Hz
Conditions
Min.
Typ.
Max.
See Model Selection Guide
See Model Selection Guide
±1.0
±2.0
VIN = Min to Max
±0.2
±1.0
IO = Min to Max
±0.5
±1.0
IO = Min to Max
±2.5
±5.0
IO = Min to Max
±2.5
±5.0
IO = Min to Max
±4.0
3.3 & 5.0 VDC Output
1.5
1.8
All Other Outputs
1.0
1.3
115 VAC, 60 Hz
20
±0.02
Zener Diode Clamp
120
Continuous (Autorecovery)
Typ. 120% to 180% of Output Power
Units
A Pk
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy, Note 1
Line Regulation
Load Regulation, Single Output
Load Regulation, Dual Output
Load Regulation, Triple Output - Primary
Load Regulation, Triple Output - Aux.
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection, Note 4
Overload Protection, Note 5
%
%
%
%
%
%
%VP-P of VO
mSec
%/°C
% of VO
General
Parameter
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
EMI/RFI
Conditions
Input to Output
Input to Output, Flash Tested For 60S
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
EMC Compliance
Switching Frequency
Min.
3,000
4,700
100
Typ.
Max.
Units
VAC
VAC
M
EN 55022 Level B
EN 61000-4-2 Level B
EN 61000-4-3
EN 61000-4-4 Level 3 2 kV
EN 61000-4-5 Level 3 1kV/2 kV
100
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size, Chassis Mount
Case Size, DIN Rail Option
Case Material
Weight
Conditions
Min.
Typ.
Max.
-25
+25
+71
-40
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
4.41 x 2.51 x 1.01 Inches (112.0 x 63.8 x 25.6 mm)
4.41 x 2.51 x 1.44 Inches (112.0 x 63.8 x 36.6 mm)
Non-Conductive Plastic& Fiberglass (UL94-V0)
6.72 Oz (191g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
Safety Class
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
250
UL 60950, EN 60950
UL, cUL; File No. E245422
IEC 61140 Class II
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Model
Number
MPM-30S-05CM
MPM-30S-12CM
MPM-30S-15CM
MPM-30S-24CM
MPM-30S-48CM
MPM-30D-12CM
MPM-30D-15CM
MPM-30T-0512CM
MPM-30T-0512CMA
MPM-30T-0515CM
MPM-30T-5312CM
MPM-30T-3512CM
Output 2 (Vout 2)
Current (A)
Voltage
(VDC)
Max.
Min.
Input
Current (A)
Output 1 (Vout 1)
Current (A)
Voltage
115 VAC 230 VAC (VDC)
Max.
Min.
0.557
0.543
0.543
0.543
0.543
0.565
0.543
0.572
0.572
0.572
0.588
0.483
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
5.0
12.0
15.0
24.0
48.0
+12.0
+15.0
5.0
5.0
5.0
5.0
3.3
6.000
2.500
2.000
1.250
0.625
+1.300
+1.000
3.000
3.000
3.000
4.500
4.000
0.600
0.250
0.200
0.125
0.063
+0.130
+0.100
+0.600
+0.600
+0.300
+0.900
+0.800
-12.0
-15.0
+12.0
+12.0
+15.0
+3.3
+5.0
-1.300
-1.000
+0.600
+1.000
+0.500
+1.000
+1.500
-0.130
-0.100
+0.120
+0.200
+0.050
+0.220
+0.300
Output 3 (Vout 3)
Current (A)
Voltage
(VDC)
Max.
Min.
-12.0
-12.0
-15.0
+12.0
+12.0
-0.600
-0.250
-0.500
+0.250
+0.250
-0.120
-0.050
-0.050
+0.050
+0.050
Capacitive
Load
Efficiency
(µF, Max)
(%, Typ)
8,000
3,900
3,900
1,500
1,000
±1,500
±1,500
See Note 6
See Note 6
See Note 6
See Note 6
See Note 6
78
80
80
80
80
80
80
76
76
76
71
71
Derating Curve
Other output combinations are available
Contact the factory for details at:
[email protected]
Notes:
1. For triple output models, the output voltage accuracy of the auxilliary outputs is typically ±4%.
2. Load regulation is measured for an output change of 0% to 100% at nominal input line. For multiple
output models, the loads are balanced.
3. Operation at no-load will not damage these units. However, they may not meet all specifications.
4. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed.
5. Output overload protection is provided by a fold back current limiting circuit.
6. For triple output models, the maximum capacitive load for 5 VDC and 3.3VDC outputs is 2,200 µF.
For all other outputs it is ±1,500 µF.
7. The MPM-30CM series includes a built-in 3.5A/250 VAC fuse. It is recommended that an
external 1.5A slow blow fuse also be used on the input for protection.
Pin Connections
Mechanical Dimensions, Chassis Mount
Pin
Single
Dual
Triple
1
AC-Neutral
2
AC-Line
3
+Vo
+Vo
+Vo 2
4
NC
NC
+Vo 1
5
-Vo
Common
Common 2/3
6
NC
NC
-Vo 1
7
NC
-Vo
+Vo 3
NC = No Connection
Model Number
A DIN Rail mounting kit is available
Contact the factory for details at:
[email protected]
MicroPower Direct
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]