Emerson Network Power LPQ150 Lpq150 sery Datasheet

150 Watts
LPQ150 Series
Total Power: 110-150 Watts
Input Voltage: 85-132 / 170-264 VAC
220-300 VDC
# of Outputs: Quad
Electrical Specs
Input
Input range
85-132 VAC or 170-264 VAC automatically selected. 220-300 VDC
47-63 Hz
38 A max, cold start @ 25°C
75% typical at full load
Meets FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
Frequency
Inrush current
Efficiency
EMI filter
Safety ground leakage
current
Special Features
•
•
•
•
•
•
•
•
•
•
•
Auto ranging input
Remote sense on main output
Remote inhibit
Single wire current sharing
Power fail
Built-in EMI filter
Low output ripple
135 khz switching frequency
Overvoltage protection
Overload protection
Adjustable floating 4th output
(On LPQ152 and LPQ153 models)
• Optional cover (-C suffix). See page 64.
Environmental
Output
Maximum power
Adjustment range
Cross regulation
Hold-up time
Overload protection
Overvoltage protection
Power failure
Remote inhibit
Electromagnetic susceptibility: designed to meet
IEC 801, -2, -3, -4, -5, -6, Level 3
Remote sense
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.75 G peak 5 Hz to 500 Hz, operational
Temperature coefficient: ± .04% per °C
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient condition
TTL logic signal goes high 50-150
msec after 5 V output. It goes low at
least 3 msec before loss of regulation
Requires an external TTL high signal to
inhibit outputs
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection
protected.
Safety
VDE
UL
CSA
NEMKO
CB
CE
114
110 W convection (75 W with cover)
150 W with 30 CFM forced air
(130 W with cover)
±5% on main; 5-25 V on 4th output
on LPQ 152 & LPQ 153
±2% on output 1; ±3% on outputs 2, 3
&4
20 ms @110 W load at nominal line
Short circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating
5.7-6.7 VDC on main output
Logic Control
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from
50° to 70°C
Storage temperature: -40° to 85°C
0.5 mA @ 50/60 Hz, 264 VAC input
0805/EN60950 (IEC950)
UL1950
CSA 22.2-234 Level 3
EN 60950/EMKO-TUE
(74-sec) 203
Certificate and report
Mark (LVD)
11774-3336-1260 (LC# 88585)
EI32002
LR53982
P95102999
2061
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
rev 12.10.03
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
LPQ150 Series
Ordering Information
Regulation2
Model
Output
Minimum
Maximum Load with
Maximum Load with
Peak
Number
Voltage
Load
Convection Cooling
30 CFM Forced Air
Load1
LPQ152
5V
12 V
-12 V
±5-25 V
2A
.1 A
.1 A
0A
15 A
6A
2A
2.5 A
22 A
8A
2.5 A
3A
30 A
10 A
3A
3A
±2%
±3%
±3%
±3%
50 mV
120 mV
120 mV
240 mV, max.
LPQ153
5V
15 V
-15 V
±5-25 V
2A
.1 A
.1 A
0A
15 A
4.8 A
1.6 A
2.5 A
22 A
6.4 A
2A
3A
30 A
8A
2.4 A
3A
±2%
±3%
±3%
±3%
50 mV
150 mV
150 mV
240 mV, max.
LPQ154
5V
12 V
-12 V
24 V
2A
.1 A
.1 A
.5 A
15 A
6A
2A
3.5 A
22 A
8A
2.5 A
4.5 A
30 A
10 A
3A
5A
±2%
±3%
±3%
+10 / -5%
50 mV
120 mV
120 mV
240 mV
1.
2.
3.
4.
5.
Ripple
P/P (PARD)3
Peak current lasting <30 seconds with a maximum 10% duty cycle.
At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4th output adjustable 5-25 V factory set at 5 V.
Minimum loads are required.
SK3
LPQ152
INHIBIT -ve
INHIBIT +ve
+12 V
No Connection
COMMON
-SENSE
+SENSE
LPQ153
INHIBIT -ve
INHIBIT +ve
+15 V
No Connection
COMMON
-SENSE
+SENSE
LPQ154
INHIBIT -ve
INHIBIT +ve
+12 V
No Connection
COMMON
-SENSE
+SENSE
PIN 8
SK2 PIN 1,2
PIN 3,4,5
PIN 6
PIN 7
PIN 8
I SHARE
+12 V
COMMON
-12 V
POK
+5 V to +25 V (Float)
I SHARE
+15 V
COMMON
-15 V
POK
+5 V to +25 V (Float)
I SHARE
+12 V
COMMON
-12 V
POK
+24 V
PIN 9
SK3 TB-1
COMMON (Float)
COMMON
COMMON (Float)
COMMON
COMMON
COMMON
TB-2
SK4 PIN 1
PIN 3
PIN 5
+5 V
GROUND
LINE
NEUTRAL
+5 V
GROUND
LINE
NEUTRAL
+5 V
GROUND
LINE
NEUTRAL
Mating Connectors
(SK4) AC Input:
Molex 09-50-8051 (USA)
Molex 09-91-0500 (UK)
PINS: 08-58-0111
(SK2) Aux DC Output/Power fail:
Molex 09-50-8091 (USA)
Molex 09-91-0900 (UK)
PINS: 08-58-0111
(SK1) Remote sense/Remote inhibit:
Molex 51110-0851 (USA)
PINS: 503-94-8100
2
1
SK2
#6-32 UNC (8 places)
1234
.5625
987654321
4th O/P ADJ
Connector
SK1 PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
SK1
8765
5V O/P ADJ
Pin Assignments
DO NOT ADJ
Note: -C suffix added to the model number indicates cover option.
7.4
(188.0)
8.5
(216.0)
Notes
1. Specifications subject to change
without notice.
2. All dimensions in inches (mm),
tolerance is ±0.02”.
3. Specifications are for convection
rating at factory settings unless
otherwise stated.
4. Remote inhibit requires an external
5V @ 10mA to activate.
5. Mounting (6-32) maximum insertion
depth is 0.12”.
6. Warranty: 1 year
7. Weight: 1.75 lb. / 0.80 kg
531
SK4
4.25
(108.0)
.875
(22.25)
.75 (19.0)
1.5
(38.1)
2.5
(63.5)
Astec Connector Kit #70-841-010, includes al of the above.
www.astecpower.com
115