MPD MPM15S09 Mpm-15s sery Datasheet

MPM-15S Series
Universal Input, 15W
Miniature, PC Mount
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 15W Output Power
Parameter
• Universal 85-264 VAC Input
Input Voltage Range
• EN 60950 Approved (UL)
Input Frequency
Input Current
• Meets IEC Safety Class II
• Adjustable Output
Min.
Typ.
85
120
47
See Model Selection Guide
115 VAC
10.0
230 VAC
20.0
Max.
264
370
63
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
±2.0
±0.5
VIN = Min to Max
See Note 2
±1.0
50
115 VAC
30
230 VAC
80
±0.02
Continuous (Autorecovery)
Zener Diode Clamp
Autorecovery 110
Max.
Units
100
%
%
%
mV P-P
Conditions
Input to Output
500 VDC
Max.
Inrush Current
• Meets EN 55022 B
Output
• >300 kHour MTBF
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
• Compact PC Mount Case
Conditions
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Over Voltage Protection
Overload Protection
Units
VAC
VDC
Hz
A Pk
mSec
%/°C
%W
General
Parameter
Isolation Voltage
Isolation Resistance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
Min.
3,000
100
Typ.
65
Standard
See Note 4
See Note 5
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
Min.
Typ.
Min.
-40
Typ.
+25
Units
VAC
M
kHz
Max.
Units
Class B
Class B
Criteria B; ±8 kV Air/±6 kV Contact
Criteria A; 10V/m
Criteria B; ±2 kV
Criteria B; ±1 kV/±2 kV
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Max.
+70
+90
-40
+105
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Case
Units
°C
°C
°C
%
Physical
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Case Size
Case Material
Weight
2.44 x 1.77 x 0.88 Inches (62.0 x 45.0 x 22.50 mm)
Non-Conductive Black Plastic (UL94-V0)
2.82 Oz (80g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Class
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
300
EN 60950
IEC 60536 Class II
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Model
Number
MPM-15S-03
MPM-15S-05
MPM-15S-09
MPM-15S-12
MPM-15S-15
MPM-15S-24
MPM-15S-48
Input
Output
Current (A)
Current (A)
Voltage
Max
Min
115 VAC 230 VAC (VDC)
0.25
0.14
3.3
3.00
0.0
0.25
0.14
5.0
2.80
0.0
0.25
0.14
9.0
1.60
0.0
0.25
0.14
12.0
1.25
0.0
0.25
0.14
15.0
1.00
0.0
0.25
0.14
24.0
0.62
0.0
0.25
0.14
48.0
0.32
0.0
Typical Connection
Notes:
Over Volt.
ciency 1. Operation at no load will not damage the units, however, they may not meet
Protection Effi
all specifications.
(%, Typ)
(VDC)
7.5
7.5
12.0
20.0
20.0
30.0
60.0
2. Load regulation is measured for an output change of 10% to 100% at nominal
input line.
3. All units are rated for EN 55022 (CE/RE) class B without external components.
4. All units are rated for EN 61000-4-4 (±2 kV) without external components. They
will meet EN 61000-4-4 (±4 kV) with additional input filtering as shown below.
5. All units are rated for EN 61000-4-5 (±1 kV/±2 kV) without external components.
They will meet EN 61000-4-5 (±2 kV/±4 kV) with additional input filtering as shown
below.
6. It is recommended that a fuse be used on the input of a power supply for protection.
For the MPM-15S series, a 2.0A/250 VAC slow blow should be used.
73
76
78
80
80
84
85
The diagram below illustrates a typical application connection of the MPM-15S-xx series. Notes on this circuit (starting with the input circuit) are:
1. It is recommended that an external fuse and NTC be used. The recommended
fuse is a 3.15A/250V slow blow and for the NTC, a 5D-9.
2. An external MOV is required on the input to protect the unit in the event of
a surge. A 561KD14 or equivalent is recommended.
3. Recommended output filtering capacitors are:
C1
680 µF/16V
680 µF/16V
470 µF/25V
220 µF/25V
220 µF/25V
68 µF/25V
33 µF/25V
MPM-15S-03
MPM-15S-05
MPM-15S-09
MPM-15S-12
MPM-15S-15
MPM-15S-24
MPM-15S-48
Typical Connection: With ACFM-01 Input Module (See note 4)
C2
0.01 µF/25V
0.01 µF/25V
0.01 µF/25V
0.01 µF/25V
0.01 µF/25V
0.01 µF/25V
0.01 µF/25V
TVS
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
SMBJ60A
Output capacitor (C2) is a high frequency, low resistance electrolytic capacitor.
Capacitor (C1) is ceramic. Voltage derating of capacitors should be >80%.
4. Input noise and surge suppression modules are available for a number of
MPD AC/DC power supplies.An MPM-15S-xx connection with the ACFM-01
is illustrated in the diagram at left. For pricing or full technical information on
these modules (ACFM-01 and ACFM-02) please contact the factory.
Pin Connections
Pin Function
2 AC-Neutral
3
AC-Line
Derating Curve
Pin
4
8
Function
-Vout
+Vout
Mechanical Dimensions
Input Voltage Vs Load
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
The MPM-15-xx series is also available with
a chassis mount or DIN mount adapter.
Contact the factory for more information
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages