Click on Series name for product info on aimtec.com Series AME5-CJZ 5 Watt | AC-DC / DC-DC Converter Picture coming soon FEATURES: • • • • I/O Isolation 3000VAC Operating Temp: -25 °C to +70 °C Input: 85-264VAC, 47-63Hz, or 120-370VDC Over current, Over Voltage Protection • • • • Continuous Short circuit protection Energy Star compliant Compact package Efficiency up to 82% Models Single output Model AME5-3.3SCJZ AME5-5SCJZ AME5-9SCJZ AME5-12SCJZ AME5-15SCJZ AME5-24SCJZ Input Voltage (VAC/Hz) Input Voltage (VDC) 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 120-370 120-370 120-370 120-370 120-370 120-370 Input Voltage (VAC/Hz) Input Voltage (VDC) 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 120-370 120-370 120-370 120-370 Output Voltage (V) 3.3 5 9 12 15 24 Output Current max (A) 1.25 1 0.55 0.42 0.330 0.23 Maximum capacitive Load (µF) Efficiency 230VAC (%) 8100 6800 1200 1000 680 270 70 75 77 79 80 82 Maximum capacitive Load (µF) Efficiency 230VAC (%) ±1480 ±130 ±110 ±16 75 79 79 80 Models Dual output Model AME5-5DCJZ AME5-12DCJZ AME5-15DCJZ AME5-24DCJZ Output Voltage (V) ±5 ±12 ±15 ±24 Output Current max (A) ±0.50 ±0.21 ±0.16 ±0.1 Models Triple output Model AME5-505TCJZ AME5-512TCJZ AME5-515TCJZ AME5-524TCJZ Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Auxiliary Output Voltage (V) Output Current max (A) Maximum capacitive Load (µF) Efficiency 230VAC (%) 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 120-370 120-370 120-370 120-370 5 5 5 5 ±5 ±12 ±15 ±24 0.8/±0.10 0.6/±0.10 0.6/±0.08 0.6/±0.05 2400/370 1600/170 1760/80 1170/50 70 73 74 75 Output Current max (A) Maximum capacitive Load (µF) Efficiency 230VAC (%) 3360/370 2400/170 2160/170 3000/100 71 73 73 75 Models Asymmetric Separated Dual output Model AME5-505DCJZ AME5-512DCJZ AME5-515DCJZ AME5-524DCJZ www.aimtec.com F 052e R8 Input Voltage (VAC/Hz) Input Voltage (VDC) 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 120-370 120-370 120-370 120-370 Output Voltage (V) 5/5 5/12 5/15 5/24 Tel: +1 514 620 2722 1 of 5 0.9/0.1 0.75/0.1 0.7/0.1 0.6/0.1 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME5-CJZ 5 Watt | AC-DC / DC-DC Converter Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current External fuse Conditions Typical 115 VAC 230 VAC 115 VAC 230 VAC 230VAC/50Hz Recommended slow blow type Maximum 125 80 Units mA mA A A mA A 10 20 0.3 1 Output Specifications Parameters Conditions Typical Voltage accuracy Line regulation Load regulation (single output) Load Regulation (dual output) Load Regulation (triple & asymmetric separated output) Minimum load Full load, main output Full load, auxiliary output 10-100% load 10-100% Balanced load 10-100% Balanced load, main output 10-100% Balanced load, auxiliary output Single output Others Ripple & Noise * 115VAC, 20MHz bandwidth 230VAC, 20MHz bandwidth Hold-up time ±2 ±0.5 ±1.5 ±1 ±2 ±3 ±5 0 10 50 15 80 Maximum Units % % % % % 150 % % mV p-p ms ms Rated Units 3000 500 VAC VDC MΩ Isolation Specifications Parameters Conditions Tested I/O voltage Isolation voltage between Main and Auxiliary output Isolation Resistance 60 sec 60 sec Typical >1000 General Specifications Parameters Switching frequency Conditions Typical Single and asymmetrical dual output Dual and triple output Maximum Units 140 KHz 65 Class I ≥110 Zener diode clamp Continuous, Auto recovery -25 to +70 -25 to +105 Protection class Over current protection % of Iout Over voltage protection Short circuit protection o Operating temperature See derating curve C o Storage temperature C o Maximum Case temperature 100 C o Temperature coefficient ±0.02 %/ C Cooling Free air convection Humidity Non condensing 95 % RH Case material Plastic (flammability to UL 94V-0) Weight 50 g Dimensions (L x W x H) 1.91 x 1.42 x 0.81 inches 48.5 x 36 x 20.5 mm o MTBF > 300,000 hrs (MIL-HDBK -217F, t=+25 C)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. www.aimtec.com F 052e R8 Tel: +1 514 620 2722 2 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME5-CJZ 5 Watt | AC-DC / DC-DC Converter Safety Specifications Parameters Agency approvals cULus, CE pending Information technology Equipment EMI - Conducted and radiated emission Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Standards IEC/EN/UL 60950-1 EN55022, class B IEC 61000-4-2 Level 3 IEC 61000-4-3 Level 3 IEC 61000-4-4 Level 3 IEC 61000-4-5 Level 3 IEC 61000-4-6 Level 3 IEC 61000-4-8 Level 3 IEC 61000-4-11 Class 2 Dimensions 3 2 Bottom View 8 7 6 5 4 1 2 Top View 6 7 8 3 1 40.50 (1.59) 4.00 (0.16) 4 5 4.00 (0.16) 12.50 (0.49) 36.00 (1.42) 10.00 (0.39) 5.50 (0.22) 48.50 (1.91) 4.00 (0.16) DIV: 10.00 (0.40) 20.50 (0.81) Ø 1.50 (Ø 0.06) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004) 6.00 (0.24) 1.00 (0.04) Pin Out Specifications Pin Single Dual Triple Asymmetric Dual 1 2 3 4 5 6 7 8 Ground AC Input (N) AC Input (L) -V Output No pin No pin No pin +V Output Ground AC Input (N) AC Input (L) -V Output No pin Common No pin +V Output Ground AC Input (N) AC Input (L) -V Output 1 +V Output 1 -V Output 2 Common +V Output 2 Ground AC Input (N) AC Input (L) -V Output 1 +V Output 1 No pin -V Output 2 +V Output 2 www.aimtec.com F 052e R8 Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME5-CJZ 5 Watt | AC-DC / DC-DC Converter Derating Free Air Convection at 25°C 100 100 80 Output Power (%) Output power (%) Free Air Convection Safe Operating Area 70 Input 100-240VAC or 120-340VDC 60 40 80 75 Safe Operating Area 60 40 20 20 0 85 100 (100) (120) 0 - 25 -20 -10 70 55 0 20 40 60 80 100 Ambient Temperature º C 240 (320) 264 (350) Input Voltage VAC (VDC) Typical application circuits AC L FUSE 1A/300V Single Output NTC + Vout AC L MOV S14K350 AC N DC AC FUSE 1A/300V AC N AC L AC - Vout - Vout + Vout DC Com C1 1µF/50V C3 1µF/50V AC N Earth/GND www.aimtec.com TVS + Dual Output NTC MOV S14K350 F 052e R8 C1 C2 1µF/50V AC N Earth/GND AC L + Vout - Vout C2 + C4 + + Vout TVS 1 Com TVS 2 - Vout Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME5-CJZ 5 Watt | AC-DC / DC-DC Converter AC L FUSE 1A/300V Asymmetric Dual Output NTC + AC L MOV S14K350 DC + AC AC N AC N AC L C3 1µF/50V Vout 2 Earth/GND FUSE 1A/300V C1 1µF/50V Vout 1 C2 C4 + Vout 1 + TVS 1 - Vout 1 + Vout 2 + TVS 2 - - Vout 2 Triple Output NTC + AC L C1 1µF/50V Vout 1 MOV S14K350 - AC N AC N AC Earth/GND + Vout 2 DC C5 1µF/50V Com C3 1µF/50V C2 + Single 3.3 & 5 Vout Single 9 Vout Single 12 Vout Single 15 Vout Single 24 Vout Dual ±5 Vout Dual ±12 Vout Dual ±15 Vout Dual ±24 Vout Triple 5/±5 Vout Triple 5/±12 & 5/±15 Vout Triple 5/±15 Vout Dual 5/5 Vout Dual 5/12 Vout Dual 5/15 Vout Dual 5/24 Vout TVS1 Vout 1 - C6 + C4 + + Vout 2 TVS2 Com TVS3 - Vout 2 - Vout 2 Model + C2 C4 C6 TVS1 TVS2 TVS3 330 µF 120 µF 120 µF 68 µF 68 µF 120 µF 68 µF 47 µF 10 µF 220 µF 120 µF 68 µF 47 µF 10 µF 22 µF 22 µF 7V 12V 20V 20V 30V 7V 20V 20V 30V 7V 7V 20V 20V 30V 7V 7V 120 µF 22 µF 22 µF 7V 20V 20V 120 µF 220 µF 220 µF 120 µF 120 µF 22 µF 22 µF 22 µF 22 µF 22 µF 22 µF - 7V 7V 7V 7V 7V 30V 7V 20V 20V 30V 30V - NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8 Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only