Astrodyne MPS200-48 200w 1~4 output for medical type Datasheet

MPS/D/T/Q200
200W 1 ~ 4 Ou t p u t f or Medi c al Ty pe
series
Universal AC input
Low leakage current ≤ 0.18mA
Protections: Short circuit / Overload / Over voltage / Over
temperature
Fixed switching frequency at 100KHz
Free air convection for 140W and forced air convection for
200W
UL60601-1 medical safety approved
With power good and fail signal output
Built-in remote ON-OFF control
Built-in remote sens function
Model Number
Output Volts
SINGLE OUTPUT
MPS200-3.3
MPS200-5
MPS200-12
MPS200-15
MPS200-24
MPS200-48
3.3 Volts(DC)
5 Volts(DC)
12 Volts(DC)
15 Volts(DC)
24 Volts(DC)
48 Volts(DC)
40 Amps
40 Amps
16.7 Amps
13.4 Amps
8.4 Amps
4.2 Amps
80mV pk-pk
80mV pk-pk
100mV pk-pk
100mV pk-pk
150mV pk-pk
2000mV pk-pk
28 Amps
28 Amps
11.7 Amps
9.4 Amps
5.9 Amps
3.0 Amps
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±1.0% ±1.0%
±1.0% ±1.0% ±1.0% ±1.0% ±2.0%
±2.0%
±2.0%
±2.0%
±1.0%
±1.0%
5 Volts(DC)
12 Volts(DC)
5 Volts(DC)
24 Volts(DC)
20 Amps
8 Amps
20 Amps
4 Amps
80mV pk-pk
120mV pk-pk
80mV pk-pk
180mV pk-pk
15 Amps
5.4 Amps
15 Amps
2.7 Amps
±0.5%
±2.0%
±0.5%
±2.0%
±1.0% ±4.0%
±1.0% +4,-6%
±2.0%
+8,-5%
±2.0%
±6.5%
DUAL OUTPUT
MPD-200A
MPD-200B
Output Amps(25CFM) Ripple & Noise Convection Line Reg Load Reg Volt Tolerance
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
MPS/D/T/Q200
200W 1 ~ 4 Ou t p u t f or Medi c al Ty pe
Model Number
TRIPLE OUTPUT
MPT-200A
MPT-200B
MPT-200C
MPT-200D
QUAD OUTPUT
MPQ-200B
MPQ-200C
MPQ-200D
MPQ-200E
Output Volts
series
Output Amps(25CFM) Ripple & Noise Convection Line Reg Load Reg Volt Tolerance
5 Volts(DC)
12 Volts(DC)
-5 Volts(DC)
5 Volts(DC)
12 Volts(DC)
-12Volts(DC)
5 Volts(DC)
15 Volts(DC)
-15 Volts(DC)
5 Volts(DC)
24 Volts(DC)
12 Volts(DC)
20 Amps
7.5 Amps
2.0 Amps
20 Amps
6.0 Amps
2.0 Amps
20 Amps
4.7 Amps
2.0 Amps
20 Amps
3.0 Amps
2.0 Amps
80mV pk-pk
120mV pk-pk
80mV pk-pk
80mV pk-pk
120mV pk-pk
80mV pk-pk
80mV pk-pk
150mV pk-pk
80mV pk-pk
80mV pk-pk
180mV pk-pk
80mV pk-pk
15 Amps
5.0 Amps
1.0 Amps
15 Amps
4.4 Amps
1.0 Amps
15 Amps
3.3 Amps
1.0 Amps
15 Amps
2.2 Amps
1.0 Amps
±0.5%
±1.0%
±0.5%
±0.5%
±1.0%
±0.5%
±0.5%
±1.0%
±0.5%
±0.5%
±1.0%
±0.5%
±1.0% ±5.0%
±1.0%
±1.0%
±5.0%
±1.0%
±1.0% ±5.0%
±1.0%
±1.0% ±5.0%
±1.0%
±2.0%
±8.0%
±5.0%
±2.0%
±8.0%
±5.0%
±2.0%
±8.0%
±5.0%
±2.0%
±8.0%
±5.0%
5 Volts(DC)
12 Volts(DC)
-5 Volts(DC)
-12 Volts(DC)
5 Volts(DC)
15 Volts(DC)
-5 Volts(DC)
-15 Volts(DC)
5 Volts(DC)
24Volts(DC)
12 Volts(DC)
-12 Volts(DC)
5 Volts(DC)
24 Volts(DC)
15 Volts(DC)
-15 Volts(DC)
15 Amps
7.0 Amps
2.0 Amps
2.0 Amps
15 Amps
5.0 Amps
2.0 Amps
2.0 Amps
15 Amps
3.0 Amps
2.0 Amps
2.0 Amps
15 Amps
2.7 Amps
2.0 Amps
2.0 Amps
80mV pk-pk
120mV pk-pk
80mV pk-pk
80mV pk-pk
80mV pk-pk
150mV pk-pk
80mV pk-pk
80mV pk-pk
80mV pk-pk
180mV pk-pk
300mV pk-pk
80mV pk-pk
80mV pk-pk
180mV pk-pk
80mV pk-pk
80mV pk-pk
12 Amps
5.3 Amps
1.0 Amps
1.0 Amps
12 Amps
4.0 Amps
1.0 Amps
1.0 Amps
12 Amps
2.3 Amps
1.0 Amps
1.0 Amps
12 Amps
2.1 Amps
1.0 Amps
1.0 Amps
±0.5%
±1.0%
±0.5%
±0.5%
±0.5%
±1.0%
±0.5%
±0.5%
±0.5%
±1.0%
±0.5%
±0.5%
±0.5%
±1.0%
±0.5%
±0.5%
±1.0% ±5.0%
±1.0%
±1.0%
±1.0%
±5.0%
±1.0%
±1.0%
±1.0% ±5.0%
±1.0%
±1.0%
±1.0% ±5.0%
±1.0%
±1.0%
±2.0%
±8.0%
±5.0%
±5.0%
±2.0%
±6.0%
±5.0%
±5.0%
±2.0%
±8.0%
±5.0%
±5.0%
±2.0%
±8.0%
±5.0%
±5.0%
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
200W 1 ~ 4 Ou t p u t f or Medi c al Ty pe
INPUT SPECIFICATIONS
Input Voltage Range
90-264VAC / 127-370 Volts(DC)
Frequency Range
47-440 Hz
Inrush Current, typ:
cold start <25 Amps @ 115VAC Input
40 Amps @ 230VAC
Input Current
3.5 Amps max @ 115VAC
1.6 Amps max @ 230VAC
Power Factor @ FL
PF>0.95/230VAC
PF>0.98/115VAC
Leakage current
heart leakage
< 0.18mA / 264VAC
patient leakage
< 0.1mA / 264VAC
OUTPUT SPECIFICATIONS
Voltage and Current
See Selection Chart
Line Regulation
See Selection Chart
Load Regulation
See Selection Chart
Voltage Tolerance (Note 2)
See Selection Chart
Ripple/Noise (Note 1)
See Selection Chart
Hold Up Time @ FL
16mS @ 230VAC
16mS @ 115VAC
Setup, Rise Time @ FL:
1000mS, 20mS / 230VAC
3000mS, 20ms / 115VAC
Over Temperature Protection
TSW1 Temp ≥ 95°C, shutdown
auto recover
Over Voltage Protection
5Volts only:115~135%, shutdown
Over Current Protection
Hiccup type 120~160% auto recover
Peak Load (Note 3)
120% of output min.
Min load
Single O/P
0%
Multi O/P
20%
DC Volt Adj
-5%~10% rated output volt
by potential meter
GENERAL SPECIFICATIONS
Safety
Insulation Resistance
UL60601-1 / UL60950-1
TUV EN60601-1 / TUV EN60950-1
IEC60601-1 approved
≥ 100MΩ
MPS/D/T/Q200
series
EMI
Compliance to EN55011, EN55022
Class B
Harmonic Current
Compliance to EN61000-3-2,-3
Efficiency
81% typ.
Isolation
4000VAC Input - Output
1500VAC Input - Ground
1500VAC Output- Ground
EMS
Compliance to
EN61000-4-2,3,4,5,6,8,11; ENV50204
Remote Control
RC+/RC-: 0~0.8Vots(DC) = Power On
4~10Volts(DC) = Power Off
Power Good/Fail
500ms/1ms
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
-20°C to +70°C (See Derate Curve)
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
-40°C to +85°C, 10~90% RH
20 to +90% RH 0.04% / °C (0-50°C)
262.1KHrs min, MIL-HDBK-217F(25°C)
10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size
Millimeters
177.8 x 107.2 x 35.5
Inches
7” x 4.22” x 1.4”
Weight
23.28 oz (660g)
NOTE
1. Ripple and Noise are measured at 20MHz of bandwidth by using a
12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor.
2. Tolerance: includes set up tolerance, line regulation and load regulation.
3. 33% Duty cycle max within every 30S. Average output power should
not exceed the rated power.
4. Derating may be needed under low inpt voltages. Please check the
derating curve for more details.
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
200W 1 ~ 4 Ou t p u t f or Medi c al Ty pe
WWW.ASTRODYNETDI.COM
MPS/D/T/Q200
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
200W 1 ~ 4 Ou t p u t f or Medi c al Ty pe
WWW.ASTRODYNETDI.COM
MPS/D/T/Q200
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
200W 1 ~ 4 Ou t p u t f or Medi c al Ty pe
WWW.ASTRODYNETDI.COM
MPS/D/T/Q200
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
200W 1 ~ 4 Ou t p u t f or Medi c al Ty pe
WWW.ASTRODYNETDI.COM
MPS/D/T/Q200
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
Similar pages