MICROJET RECORDER (180mm) DATA SHEET PHA This recorder can record a maximum of 12 channels of DC voltage, mA, thermocouples and resistance bulbs. The adoption of an ink jet system makes it possible to record measured data in analog trace mode or to print in digital mode at a high speed. This 180mm-wide recorder performs recording clearly in 6 different colors. FEATURES 1. Compact size Compact and lightweight design, 199mm in depth and about 6kg in mass{weight}. 2. High quality recording • Ink jet system is used for recording and printing measured data in 6 different colors at a high speed. Operating noise is minimized. • Six and twelve continuous traces without pen offset are possible with this compact size of recorder; a unique recording system is used for the first time in the industry. • Scale of each channel is printed on chart paper, elimi- nating the need for scales. 3. Easy setting of input signals DC voltage input (5mV span, 50V max.), 12 kinds of thermocouples (Type B, R, S, K, E, J, T, N, W, L, U, PN) and resistance bulbs (Pt100) can be set for each channel. 4. Digital printing Beside the analog recording of measured data, digital printing is also available (periodic printing, list printing, alarm printing, daily report printing, message printing). • Periodic data printing: Channel No., date, time, unit, chart speed, measured value • List printing: Date, time, unit, recording range, scaling value, alarm set value, chart speed, Tag No. • Alarm printing: Channel No., alarm type, on/off time, output relay No. • Daily report and totalized data printing: Printing of maximum, minimum, average and total of data measured during maximum 24 hours • Message printing : 10 messages, 16-character userentered messages 5. Interactive key operation Fluorescent indicator is used to clearly indicate alphanumeric characters and symbols. Input mode, recording range, alarm value, chart speed, etc., can be set according to the comments indicated by the display and operating keys. No bothersome operation is required. 6. Easy handling • A cartridge type recording device is used for easy replacement. • Chart paper can be loaded without drawing out the internal unit of the recorder. • Shortage of ink is detected in early stages and an alarm is given to the operator. • The end of chart paper is detected and indicated on the front panel display. • Shortage of ink and the end of chart paper alarm output is possible. 7. Full variety of functions • Alarm relay output/external control (record start/ stop, chart speed change, data printing, message printing). This unit can easily be connected to the recorder by user (option). • Chart paper illumination lamp (option): The result of printing can be checked even in lower light. • Burnout function is provided as a standard. • Various recording: Enlarged/reduced recording, auto-range recording, zone recording. • Calculation: Square root extraction, subtraction, engineering unit conversion, logarithm. • Language: Selectable 3 languages in display and printing. • Passcode security is configurable. • The message print and alarm print function are operational, even when the recording mode is off. • All parameters of recording format, daily report, totalize, message and periodic data printing can be printed cut. EDSX10-60m Date Nov. 24, 2011 PHA Chart speeds: SPECIFICATIONS Input system Input points: 6 or 12 continuous recording and intermittent recording Input signal: Thermocouple input…B, R, S, K, E, J, T, N, W, L, U, PN Resistance bulb input…Pt100Ω DC voltage input…50mV, 500mV, 5V, 50V range DC current input…4 to 20mA DC, 10 to 50mA DC (Shunt resistor (option) need to be connected to the terminal) Max. input voltage: • Thermocouple, resistance bulb and DC voltage (50mV, 500mV range) …±10V DC or less • DC voltage input (5V, 50V range) …±100V DC or less Input signal setting and change: Setting and change of input signal between thermocouple, resistance bulb and DC voltage (50mV, 500mV, 5V, 50V range) is possible for each channel by the setting pin in the instrument. Setting of recording range: Setting is possible within the reference range by using the keyboard. Burnout function:When thermocouple or resistance bulb input is disconnected, the recording is deflected to 100%. Reference range: Kind Reference range Thermocouple Resistance bulb DC voltage Note: N W L U PN Pt100 B R S K E J T N W L U PN 400 0 0 –200 –200 –200 –200 0 0 –200 –200 0 to to to to to to to to to to to to 1760°C 1760°C 1760°C 1370°C 800°C 1100°C 400°C 1300°C 1760°C 900°C 400°C 1300°C Pt100 –200 to 600°C –50 –500 –5 –50 to to to to +50mV +500mV +5V +50V Reference range 752 32 32 –328 –328 –328 –328 32 32 –328 –328 32 to to to to to to to to to to to to 3200°F 3200°F 3200°F 2498°F 1472°F 2012°F 752°F 2372°F 3200°F 1652°F 752°F 2372°F –328 to 1112°F Scaling is possible within the range of –32767 to +32767 (decimal point may be put as necessary) : NICROSIL-NISIL (IEC584) : +side 5% Re, –side 26% Re.W (Hoskins Mfg. Co., U.S.A.) : +side Fe, –side Cu.Ni alloy (DIN43710) : +side Cu, –side Cu.Ni alloy (DIN43710) : Platinel : DIN IEC751 Recording system Writing system: Ink jet system, 6 colors Chart width: 180mm Recording color: No. 1,7 channel (orange), No. 2.8 channel (green), No. 3, 9 channel (purple), No. 4, 10 channel (red), No. 5, 11 channel (black), No. 6, 12 channel (blue) Recording color can be assigned for each channel. Chart length: Z fold 20m 2 Continuous recording type 5 to 300 mm/h, continuous recording 301 to 1500 mm/h, intermittent recording Intermitter recording type 5 to 1500 mm/h Each can be set in 1 mm/h steps. Recording cycle: Intermitter recording…30sec/all points Continuous recording…Depends on chart speed. <Calculation formula> Recording 450 = cycle[sec] Chart speed [mm/h] (not faster than 3 seconds.) Measuring cycle: Up to 3 inputs…160ms 6, 12 inputs…320ms Service life of ink: (Depends on operating conditions) About 6 months for 6 points of linear recording at 25 mm/h of chart speed Chart handling: Tear off without disturbance of recording. Indicating system Indication: Fluorescent indication (blue-green), 20 characters × 2 lines Characters indicated: 5 × 7 dots, 5.0mm high, 3.5mm wide Contents of indication: (1) Measured value: Temperature…1 digit below decimal point; Voltage…6 digits (including sign and decimal point) M easured value of No.1 channel to No.6 or No.7 channel to No.12 can be indicated simultaneously. (2) Channel No.: 2 digit (1 to 12) (3) Engineering unit: Max. 7 digits (°C, °F, %, Pa, bar, ppm, m3/h, etc.) (4) Tag No….8 characters (5) Time: Year, month, day, hour, minute (6) Status indication: R ecord ON, chart end, battery alarm, alarm, ink shortage alarm, burnout, carriage failure Configuration: These can be set according to the comments indicated by operating keys as follows, Passcode Main chart speed Sub chart speed Alarm setting Record mode (trend/logging) Recording range Input signal List print request Tag No. Daily report setting Totalize function Communication parameter Date and time setting Ink monitor clear Illumination on/off Message definition Measured value shift Printing system Writing system: Ink jet system, 6 colors Periodic data printing: Measured value, unit, date, time, time line, chart speed, channel No. List printing: (1) Measured value list (date, time, channel No., measured value, unit) (2) P arameter list (date, time, channel No., recording range, scaling, unit, alarm set value, chart speed, Tag No.) (3) Test pattern (all characters and color patterns) Message printing: 1 0 m e s s a g e s , 1 6 - c h a r a c t e r u s e rentered messages. Alarm printing: Channel No., alarm type (H, L, RH, RL), output relay No., on/off time Burnout printing: Burnout channel No. and time Other: Ink shortage message, automatic range selection mark, recording start mark, chart speed change mark Note: Printing is not available for more than 301 mm/h (continuous recording), or more than 51 mm/h (intermittent recording). Performance and characteristics Accuracy and resolution: Performance under reference condition (23±2°C, 65±10%RH, power voltage and frequency variation ±1%, warm-up time 30 minutes or more, vertical mounting, free from the effect of external noise) Resistance bulb DC voltage Physical data Mounting: Panel (may be inclined up to 30° backwards from the vertical.) Indication (digital) Recording Input Thermocouple Power supply terminal - ground …2000V AC, 1 minute Input terminal - ground …500V AC, 1 minute Power terminal - input terminal …500V AC, 1 minute Between alarm terminals …750V AC, 1 minute (Leakage current 5mA or less, however, if the power supply is 24V DC, Leakage current of “Power supply terminal - ground” is 10mA or less) Reference junction compensation accuracy: K, E, J, T, N, L, U, PN ............. ±0.5°C (In case of minus input measurement: ±1.2°C) R, S, B, W .............................. ±1°C (In case of minus input measurement: ±2.4°C) Common mode noise rejection: 120dB at 50, 60Hz ±0.1Hz Series mode noise rejection: 30dB at 50, 60Hz ±0.1Hz Accuracy B R S K E J T N W L U PN ±(0.15% +1 digit) (without reference junction compensation error) Pt100 ±(0.15% +1 digit) –50 to +50mV ±(0.15% –500 to +500mV +1 digit) –5 to 5V –50 to 50V Resolution 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C Accuracy Material: Indication accuracy, ±0.25% of recording span 0.1mm minimum 0.1°C 10 µV 100 µV 1mV 10mV Note: Indication accuracy is in % of reference range. Indication accuracy of B type TC is ±(0.36%+1digit) between 400°C to 600°C. Indication accuracy of all type TC is ±(0.36%+1digit) between –200°C to –100°C. Input resistance: =90° to 60° Resolution Thermocouple:>10MΩ 50mV range: >10MΩ 500mV range: >100kΩ 5V and 50V range: >1MΩ Chart speed accuracy: ±0.1% (expansion and contraction of paper is not included) Clock accuracy: ±50ppm or less (monthly error; about 2 minutes) Insulation resistance: 100MΩ or more (between each terminal and earth, at 500V DC) Withstand voltage: Input terminal - input terminal …500V AC, 1 minute Case...Steel plate Front door frame…Polycarbonate with glass wool Mass{weight}: Approx. 6 kg (without option) Approx. 7 kg (with option) Case size: Bezel 288x288mm Depth 199mm Cutout 281x281mm Finish color: Case…Black, Front door frame…Black External terminals: Screw terminal (M4 screw) Power requirement 1) S upply voltage 100 to 240V AC products (9digit of code symbol = “E”) • Power supply voltage: 100V (-15%) to 240V (+10%) AC (Free power supply) • Supply frequency: 50/60Hz both employable • Power consumption: 1 00V AC with all options approximately 37VA 2 40V AC with all options approximately 56VA 2) Supply voltage 24V DC products (9digit of code symbol = “L”) • Power supply voltage: 24V (±10%) DC • Power consumption: 2 6.4V DC with all options 37VA or less 3 PHA Operating environment (for devices to operate continuously) Temperature limits: 0 to 50°C Humidity limits: 20 to 80%RH, non condensing is required (temperature x humidity<3200) Vibration: 10 to 60Hz, 0.2m/s2{0.02G} or less Mounting position: Front inclination 0°, rear inclination 30°, left/right inclination 0° Signal source resistance: Thermocouple input…1kΩ or less Voltage input…Less than 0.1% of input resistance Resistance bulb input…Less than 10Ω per line (Resistance of each wire of 3-wire system should be balanced with others.) Warm-up time: 30 min or more Shock: No external shock Environmental protection: IEC IP50(Front) / 20(Terminal) Installation category: Ⅱ Pollution degree: 2 Operating altitude: 2000m max. Operating environment influence Effect of power supply fluctuation : (1) Supply voltage 100 to 240V AC products (9digit of code symbol = “E”) Voltage variation: 85 to 264V AC (frequeucy: 50/60Hz) 100VAC base Change in indication… ±(0.1%+1 digit) max. Change in recording… ±0.2% of recording span, max. Frequency variation: 47 to 63Hz (power voltage: 100V AC) 50Hz base Change in indication… ±(0.1%+1 digit) max. Change in recording… ±0.2% of recording span, max. (2) S upply voltage 24V DC products (9digit of code symbol = “L”) With 21.6 to 26.4V DC fluctuation, 24V DC base Change in indication....±(0.1% + 1 digit) max. Change in recording....±0.2% of recording span, max. Input signal source resistance or wiring resistance influence: Thermocouple…10 µV per 100Ω Vo l t a g e i n p u t … Va r i a t i o n o f 0 . 1 % change of resistance Change in indication… ±(0.1%+1 digit) max. Change in recording… ±0.2% of recording span, max. Reistance bulb…Variation of resistance with changes in 10Ω per wire Change in indication… ±(0.1%+1 digit) max. Change in recording… ±0.2% of recording span, max. (3 wires should be balanced.) 4 Temperature influence: Change in indication… ±(0.3%+1 digit)/10°C, max. Change in recording… ±0.5%/10°C, max. Mounting position influence: Inclination within 30° Change in indication… ±(0.1%+1 digit) max. Change in recording… ±0.2% of recording span, max. Vibration influence: Linear vibration with 10 to 60Hz of frequency and 0.2m/s 2 {0.02G} of acceleration is applied to each of 3 directions for 2 hours. Change in indication… ±(0.1%+1 digit) max. Change in recording… ±0.2% of recording span, max. Effect of external noise: Normal mode noise (50,60Hz±0.1Hz) …30dB or more ommon mode noise (50,60Hz±0.1Hz) C …120dB or more Chart paper influence: Standard temperature/humidity: 20°C, 65%RH Expansion at 85%RH…0.4% max. Contraction at 35%RH…0.5% max. Alarm Setting method: Setting from keyboard Number of alarm levels: Max. 4 levels for each channel Alarm type: High(H), Low(L), High-rate of change(RH), Low-rate of change(RL) Alarm action indication: Kind of alarm and output relay No. are indicated for each channel at occurrence of alarm. Printing: Channel No., kind of alarm, output relay No. and on/off time are printed on chart paper. Output: See optional specifications. Hysteresis: Approx. 0.5% of recording span Alarm timing: Recognition; 1 second (worst case) Action; additional 1 second (worst case) Alarm latch: Hold the alarm display and alarm output. Others: Shortage of ink and the end of chart paper alarm output is possible. Transportation/storage condition (Detach a recording head from the main unit before transportation) Temperature limits: –10 to +60°C Humidity limits: 5 to 90%RH, non condensing is required Vibration: 10 to 60Hz, 2.45m/s2{0.25G} Shock: 294m/s2{30G} or less Optional specifications 1. Chart illumination: LED 2. Alarm output/3-point external control: This unit can be mounted from the rear side of the recorder. (1) Alarm output (DO): 6 or 12 points of relay contact N.O. (1a) output for individual channel operation or common operation Maximum contact voltage 240V AC, 30V DC Maximum contact current 3A (resistive load) (2) External control (DI): The following control is possible with external contact signal. • Recording start/stop; Recording start/stop is effected by contact signal. Recording is started when contact is closed and stopped when contact is open. • Chart speed change; Selection between normal and remote chart speeds is effected by contact signal. Remote chart speed is selected when contact is closed and normal when contact is open. • Measured value printing; Measured value list printing (date, time, channel No., measured value, unit) is effected by contact signal. Printing is started when contact is closed. • Message printing Periodic data printing function Time, date, chart speed, measured value and unit can be printed at fixed intervals. Printing can be enabled/disabled from keyboard. Message printing Maximum 10 messages, 16- character userentered messages can be printed. Alarm printing function Time, channel No., kind of alarm, and output relay No. can be printed when alarm is on or off. Unit indication Engineering units such as °C, °F, %, mV, mA, Pa,L, etc., are indicated (setting from key board). Scaling function Scaling with DC voltage input is possible. (Setting of decimal point is also possible within the range of –32767 to +32767). Subtract function Difference between any channels is recorded (channel is set from keyboard). Logarithm Measured value can be displayed and printed by 10n power Auto-range recording Recording range is automatically changed for recording in the event of overrange or underrange (setting with keyboard). This function is not available for combination of zone recording and enlarged/reduced recording. Zone recording Recording area is divided into a maximum of 4 zones for recording. This function is not available for combination of automatic range selection and enlarged/reduced recording. Enlarged/reduced recording A part of recording area of each channel is expanded or contracted for recording. This function is not available for combination of automatic range selection and zone recording. Square-root extraction function Square-root extraction of DC voltage input is possible. Daily report function Measured value of every hour for maximum one day (24 data) in each channel is stored for printing. Maximum, minimum and average values are also printed at the same time. ON-OFF operation, ON-OFF of each channel and operation start time/stop time can be set from keyboard. Totalize function Integrated value of every hour for maximum one day (24 data) in each channel is stored for printing (integration in 1 sec steps). Possible to print total value only. Total value is also printed at the same time. ON-OFF operation, ON-OFF of each channel and operation start time/stop time can be set from keyboard. Measured value shift Shift the zero point and inclination of the measured value so that the measured value can be adjusted according to other instruments. Memory backup Set data and clock function are protected by built-in lithium battery (expected battery life, about 10 years under normal temperature). Input filter Response is delayed according to sudden changes in input of each channel (1st order lag filter). Time constant setting range: 0 to 900 sec (setting from keyboard). Burnout function When thermocouple or resistance bulb input is disconnected, it is deflected 100%. Also, it is indicated and printed at the same time. Passcode 4 digits passcode security is available. Language English, German, or French is selectable for display and printing. Alarm latch function The alarm display and alarm output are held even after the cause of alarming was gone. ON-OFF operation can be set from keyboard. Cancellation of the held alarm can be made from external control (DI). Parameter copy Set parameters on any channel can be copied to any other channels. Note: For external control, use a dry contact. Contact capacity: 12V DC, 0.05A, N.O. (1a) contact 3. Transmission function: T-link interface for transmitting measured value and receiving the condition of setting. Transmission method Half-duplex bit serial Transmission speed 500kbps Transmission distance Max. 500m I/O frame 8w or 16w Message frame Available to set/change parameters etc. FUNCTIONS Function Description Recording range can be set for each channel. Input setting Any input can be set for each channel. Skip function Used to skip recording, indication and alarm at any measuring point. List printing function Range setting Measured value list Date, time, and measured value unit can be printed. Parameter list Date, time, recording range, scaling, unit, kind of input, alarm set value, chart speed, and Tag No. can be printed. Test pattern All characters and color patterns can be printed. 5 PHA SCOPE OF DELIVERY CODE SYMBOLS 1 2 3 4 5 6 7 8 - 9 10111213 PHA 0 0 4 6 7 8 9 V Description Recording points 6 continuous recording 6 intermittent recording 12 intermittent recording 12 continuous recording 6 6 8 8 E L A B 2 Y T Note: Ink cartridge is not mounted on the recorder at the time of delivery. Power Supply 100 to 240V AC 50/60Hz 24V DC Spare parts Chart paper illumination Without With Ink cartridge PHZH1002 Chart paper (0 to 100, 100 uniform division) PEX00BL1-1000B Alarm output/external control Without 6-point alarm output/3-point external control 12-point alarm output/3-point external control 0 1 Recorder, panel mounting bracket, accessories (ink cartridge (1), fuse (1), chart paper (1), ink absorption cloth (1)). Instruction manual (1). Transmission function Without With T-Link Remarks: Input signal Setting prior to delivery is as follows. • Thermocouple K: 0 to 1200 °C Note: Contact Fuji Electric for additional features not listed such as Flow integration record and Calculation of input signals. Item Part No. Unit of quantity for sale 1 pc 1 box (6 charts) Other (optional items) Item Type Specification Shunt resistor PHZT8101 For 10Ω ±0.1% Alarm output/ external control unit PHZK8601 With 6-point alarm output/3-point external control PHZK8201 With 12-point alarm output/3-point external control The product conforms to the requirements of the Electromagnetic compatibility Directive 89/336/EEC as detailed within the technical construction file number TN510405. The applicable standards used to demonstrate compliance are:EN 55011 : 1991 CLASS A Conducted and Radiated emissions EN 50082-1 :-1992 Radiated immunity, ESD and FBT PHA 6 OUTLINE DIAGRAMS (Unit:mm) Alarm unit(option) (Alarm 7 to 12) 2 Alarm/external control unit(option) (Alarm 1 to 6, DI 1 to 3) Transmission terminal (option) T 30 t Mounting bracket Panel Input terminal 1 (Input 1 to 6) 288 280 Input terminal 2 (Input 7 to 12) Power terminal 39 280 288 160 199 312 18 360 min. Panel cutout 320 min. 281+20 281+20 CONNECTION DIAGRAMS Input terminal 2 Terminal No. Thermocouple Resistance Voltage + buld – Input terminal 1 71 72 Input 7 73 81 82 + – + – 11 12 Input 2 31 32 33 Input 9 41 102 42 Input 10 103 43 111 51 123 Transmission terminal (option) 21 12 22 13 23 DI 1 DI 2 DI 3 TRX1 TRX2 SHLD – + Power terminal 23 101 122 11 Input 1 13 21 22 Input 8 91 112 113 121 Alarm/external control unit (option) (Alarm 1 to 6, DI 1 to 3) Terminal No. 83 92 93 Alarm unit (option) (Alarm 7 to 12) Input 11 Input 12 Input 3 Input 4 Input 5 + 52 53 61 – 62 Input 6 63 31 41 Alarm 7 14 24 Alarm 1 32 42 Alarm 8 15 25 Alarm 2 33 43 Alarm 9 16 26 Alarm 3 34 44 Alarm 10 17 27 Alarm 4 35 45 Alarm 11 18 28 Alarm 5 36 46 Alarm 12 19 29 Alarm 6 DI 1 DI 2 DI 3 AC AC G Power source 100 to 240V AC 50/60Hz + - G Power source 24V DC Record start or message print 1 Chart speed change or message print 2 Measured value printing or alarm latch cancel or message print 3 7 PHA Caution on Safety *Before using this product, be sure to read its instruction manual in advance. International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fujielectric.com/products/instruments/ Information in this catalog is subject to change without notice. Printed in Japan