SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Features ‧Close to the human eye's response ‧15 bit effective resolution ‧50Hz/60Hz rejection ‧Low sensitivity variation across various light sources o o ‧Operating temperature performance, -40 C to 85 C ‧Wide supply voltage range, 2.7V to 5.5V ‧ Low power consumption, less than 2mW while operating ‧ Shut-down mode, current consumption less than 0.1uA 2 ‧ I C serial port communication: (1) Standard 100kHz, (2) Fast 400kHz ‧High dynamic sensing range from 0 to 88,000 Lux ‧Dimension: 2.0mm(L)x2.0mm(W)x0.6mm(H) ‧RoHS compliant and Pb Free Description 2 The ALS-PDIC17-57B/TR8 is a digital-output light sensor with a two-wire, I C serial interface that is compatible with SMBus operating at 100 KHz serial clock frequency. It combines a photodiode and an analog-to-digital converter (ADC) on a single CMOS integrated circuit to provide light measurements over an effective 15-bit dynamic range. Provided with constantly refreshing ADC. The integrating conversion technique used by ALS-PDIC17-57B/TR8 effectively eliminates the effect of flicker from AC-powered lamps, increasing the stability of the measurement. ALS-PDIC17-57B/TR8 is very close to human-eye vision, having very low response to non-visible light, such as infrared and ultra-violet light. Applications ‧Detection of ambient light to control display backlighting Mobile devices – Mobile phones, PDAs, Table PC and GPS Computing device – TFT LCD monitor Consumer device – TFT LCD TV, Plasma TV, Video camera, Digital camera, Toys ‧Detection of ambient light for controlling the backlighting of TFT LCD display ‧Automatic residential and commercial lighting management ‧Automatic contrast enhancement for electronic signboard ‧Ambient light monitoring device for daylight and artificial light 1 Copyright Revision :2 © LifecyclePhase: 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 Date:2013-06-04 08:06:07.0 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Package Dimensions Unit: mm Tolerance: ±0.2mm 2 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Absolute Maximum Ratings (Ta=25℃) Parameter Symbol Rating Unit Storage Temperature TSTG -40 ~ 100 ℃ Operating Temperature TOPR -40 ~ 85 ℃ Supply Voltage VDD -0.3 ~ 6 V Digital Output Voltage VO -0.3 ~ 6 V Digital Output Current IO -10 ~ 10 mA ESDHBM ≧2 KV ESD Tolerance (Human Body Model) Block Diagram & Pad Descriptions Figure 1. 3 Copyright Revision :2 © LifecyclePhase: ALS-PDIC17-57B/TR8 Functional Block Diagram Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Electrical and Optical Characteristics (Ta=25℃, VDD=3.3V) Parameter Symbol Min. Typ. Max. Unit Condition Supply Current IDD ----- 0.4 0.53 mA VDD=3.3V Power-Down Mode Supply Current IDDQ ----- ----- 0.1 μA VDD=3.3V VOL ----- ----- 0.4 V Io = 4mA Detection Full Counts ----- ----- 32767 Counts Detection Limit ----- 44200 ----- Lux 2 I C output low voltage Peak Sensitivity Wavelength λP ----- 580 ----- nm Response in Dark Environment Rdark ----- ---- 1 Count Rfrst 44 73 102 Counts Ricd 65 108 151 Counts Response in Fluorescent Light [Note1] Response in Fluorescent Light [Note2] TINT=100mS VDD=3.3V EV=0Lux TINT=100ms VDD=3.3V EV=100Lux TINT=100mS VDD=3.3V EV=100Lux TINT=100mS Note: 1. Fluorescent light (Color Temperature = 6500K) is used as light source. However, White LED is substituted in mass production. 2. Illuminance by CIE standard illuminant-A 2856K of incandescent lamp. 4 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 DC Characteristics of I2C Signals in Standard and Fast Mode Parameter Symbol Standard Mode Fast Mode Unit Min. Max. Min. Max VDD 2.7 5.5 2.7 5.5 V Low Level Input Voltage VIL -0.5 1.0 -0.5 1.0 V High Level Input Voltage VIH ----- VDD*0.6 V Power Supply Voltage (Recommend) VDD*0.6 ----- [Note3] Hysteresis of Schmitt trigger inputs (VDD > 2V) [Note3] Vhys 0.05*VDD ----- 0.05*VDD ----- V VOL1 0 0.4 0 0.4 V Tof ----- 250 20+0.1Cb 250 [Note2] [Note1] [Note2] Low level output voltage (open drain) at 3mA sink current (VDD > 2V) Output fall time from VIHMIN to VILMAX with a bus capacitance from 10pF to 400pF nS Input current of each IO pins with an input voltage between 0.1VDD II/P -10 10 -10 10 μA CI ----- 10 ----- 10 pF and 0.9VDD Capacitance for each IO pin Notes: 1. 2. 3. Cb = capacitance of one bus line in pF 2 The maximum tof for the I C data and clock bus lines quoted in the AC table is longer than the specified maximum tof for the output stages (250nS). This allows series protection resistors (RS) to be connected between 2 2 I C data / clock pins and the I C data / clock bus lines without exceeding the maximum specified tof. 2 The I C bus operation voltage is 1.8V, The ALS-PDIC17-57B supply voltage must≦3V (3Vx0.6=1.8V) 5 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 AC Characteristics of I2C Signals in Standard and Fast Mode Parameter 2 Symbol I C clock frequency Hold time (repeated) START condition. After this period, the first clock pulse is generated. 2 Low period of I C clock 2 High period of I C clock Set-up time for a repeated START condition 2 Data hold time for I C-bus devices Data set-up time 2 Rise time of both I C data and clock signal’s 2 Fall time of both I C data and clock signal’s Set-up time for STOP condition Bus free time between STOP and START condition Capacitive load for each bus line Standard Mode Fast Mode Unit Min. Max. Min. Max fSCL 0 100 0 400 KHz tHD;STA 4.0 0.6 - us tLOW tHIGH 4.7 4.0 1.3 0.6 us us tSU;STA 4.7 0.6 us tHD;DAT tSU;DAT 0 250 3.45 - 0 100 0.9 - us ns tr - 1000 5 300 ns tf - 300 0.1 300 ns tSU;STO 4.0 - 0.6 - us tBUF 4.7 - 1.3 - us Cb - 400 - 400 pF 2 Figure 2 I C Timing Diagram 6 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Typical Electro-Optical Characteristics Curves Fig 3 Light Output vs. Illuminance Fig 4 Current Consumption vs. Illuminance Fig 5 Current Consumption vs. Supply Voltage Fig 6 Dark Output vs. Supply Voltage Fig 7 Light Output vs. Supply Voltage Fig 8 Current Consumption vs. Temperature 7 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Fig 9 Dark Output vs. Temperature Fig 10 Light Output vs. Temperature Fig 11 Spectrum Fig 12 Relative Sensitivity vs. Angle 8 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Communication Protocol 2 ALS-PDIC17-57B contains an 8-bit command register that can be written and read via the I C bus. The command register controls the overall operation of the device. There is a two-byte word read-only register that contains the latest 2 converted value of A/D converter. The I C slave address is hardwired internally as 0101001 (0x29, MSB to LSB, A6 to A0). All the Send Byte protocol, the Receive Byte protocol and Receive Word protocol are implemented in ALS-PDIC17-57B. The Send Byte protocol allows single bytes of data to be written to the device (see Figure 13-a). The written byte is called the COMMAND byte. The Receive Byte protocol allows one-byte data to be read from the device (see Figure 13-b). Two-byte data can be read by following the Receive Word Protocol shown in Figure 13-c. In Figure 13, the clear area represents data sent by the host (master) and the shaded area represents data returned by the ambient light sensor (slave device). 1 S 7 Slave Address 1 WR 0 1 A 0 8 Command Byte 1 A 0 1 RD 1 1 A 0 8 Data 1 NA 1 1 RD 1 1 A 0 8 LS byte of ADC 1 A 0 1 P (a) Send byte protocol 1 S 7 Slave Address 1 P (b) Receive byte protocol 1 S 7 Slave Address 8 MS byte of ADC 1 NA 1 1 P (c) Receive word (two bytes) protocol S = start condition P = stop condition Shaded = slave transmission A = acknowledge NA = not acknowledge WR = write RD= read Figure 13 Communication Protocol 9 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Communication Format 2 2 ALS-PDIC17-57B is capable of working as an I C slave. Address of this device on I C bus is always 0x29 2 (hexadecimal number 29). Registers of the slave device can be programmed by sending commands over I C bus. 2 Figure 14 shows an I C write operation. To write to an internal register of the slave device a command must be sent 2 2 by an I C master. As illustrated in Figure 14, the I C write command begins with a start condition. After the start condition, seven bits of address are sent with MSB going first. RD / WRn (=Low) command bit follows the address bits. Upon 2 receiving a valid address the slave device responds by driving SDA low for an ACK. After receiving an ACK, I C master 2 sends eight bits of data with MSB first. Upon receiving eight bits of data the slave device generates an ACK. I C master terminates this write command with a stop condition. 2 Figure 14 I C Timing Diagram for Send Byte Format 2 2 Figure 15 shows an I C read command sent by the master to the slave device. I C read command begins with a start condition. After the start condition seven bits of address are sent by the master with MSB going first. After the address bits, RD / WRn command bit is sent. For a read command the RD / WRn bits is high. Upon receiving the address bits and RD / WRn command bits the slave device responds with an ACK. After sending an ACK, the slave device sends eight bits 2 of data with MSB going first. After receiving the one byte data, the I C master terminates this transaction by issuing a NACK command to indicate that the master only wanted to read one byte from the device. The master generates a stop condition to end this transaction. 2 Figure 15 I C Timing Diagram for Receive Byte Format 10 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Ambient light intensity count value can be obtained by reading registers of this device. Ambient light intensity count is a 15-bit wide number plus a valid bit and hence word (two bytes) read operation is needed, as shown in Figure 2 16. After receiving the two byte data, the I C master terminates this transaction by issuing a NACK command to indicate that the master only wanted to read two bytes from the device. The master generates a stop condition to end this transaction. 2 Figure 16 I C Timing Diagram for Receive Word Format 11 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Theory of Operation The photocurrent, generated by the built-in photodiode while being illuminated, is proportionally converted to frequency; the digital frequency signal is then integrated by a 15-bit counter for a predetermined period of time (Tint). This period of time is called integration time which can be adjusted by changing the nominal value of the resistor 2 between the RINT and GND terminals. The converted data are read out through a two-wire, I C Interface bus. Since the photodiode has been specially processed to suppress the spectral response in infrared region, the readout is very close to the photopic transfer function, v(λ), which is the mathematic expression of human-eye's response to ambient light. Address Option for I2C The device address is 0x29. ADC Register The ADC register contains 16 bits with a 15-bit wide data from D0 to D14 and a valid bit D15. The register is divided into two groups; D[15..8] is the most significant (MS) byte and D[7..0] is the least significant (LS) byte. See Table 2 for details. Valid Bit D15 D14 MSB Data Bits D13 ~ D8 D7~D1 Most Significant (MS) byte D0 LSB Least Significant (LS) byte Table 1 ADC Register Structure 12 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Device Command 2 There are three command codes are provided for I C master to control the ambient light sensor. The specific function corresponding to each command code is elaborate in Table 2. Command Code Function Shut-down mode, this is the default state after applying VDD power to the device. 1xxx_xxxx (binary code) During shut-down mode, users can do the communication test. Except the MSB must be logic 1, the value written to the command register will not change any 2 function and can be read back via the I C bus by issuing Receive Byte Protocol. 2 0x04 0x08 0x30 Activate the ambient light sensor. The integration time is controlled by I C commands, start and stop integration. Start integration: This command will reset the ADC register to 0x0000 and begin a new integration. Stop integration: This command will stop the integration and set the valid bit (D[15]) high. Table 2 Command Code List 13 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Programming Sequence External integration timing (1). After being powered on, the device will initially be in the shut-down mode (default setting). (2). To operate the device, issue an Send Byte protocol (see Figure 13-a) with the device address 0x29 followed by a command byte of 0x04 to activate the ambient light sensor. 2 (3). I C master sends a "start integration command" to the slave device by issuing Send Byte protocol with the device address 0x29 followed by a command byte of 0x08. 2 (4). After a period of user defined integration time, I C master sends a "stop integration command" to the slave device by issuing Send Byte protocol with the device address 0x29 followed by a command byte of 0x30. (5). To read the ADC conversion result, issue an Receive Word protocol (see Figure 13-c) with the device address 0x29 followed by two-byte reading procedures. (6). If the stop integration command is not received by the device, the valid bit (D[15]) will be “0” to indicate that the data is not valid. If there is a valid conversion result available, the valid bit (D[15]) will be set logic high, and the remaining 15 bits will represent valid data from the ADC register. (7). Data may be read repeatedly from the ADC register, and although it will remain valid, the ADC register will not be updated until a new complete integration cycle has been carried out. In this cases, the power consumption of the device can be reduced by issue a send Byte protocol with the device address 0x29 followed by a data byte of 1xxx_xxxx.(Binary code) 14 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Noise Rejection and Integration Time In general, integrating type ADC’s have an excellent noise rejection characteristics for periodic noise sources whose frequency is an integer multiple of the integration time. For instance, a 60Hz AC unwanted signal’s sum from 0ms to n*16.66ms (n = 1, 2...ni) is zero. Similarly, setting the ALS-PDIC17-79NB integration time to an integer multiple of periodic noise signal greatly improves the light sensor output signal in the presence of noise. The integration time, Tint, of the ALS-PDIC17-79NB is set by an external resistor Rext. The maximum detection range is inversely proportional to the integration time; that means the longer integration time the lower detection range. Integration time ( mS ) 50 100 200 300 400 Detection range ( Lux ) 88,400 44,200 22,200 14,500 11,100 Resolution ( Lux / Count ) 2.7 1.35 0.68 0.45 0.34 Table 3 Detection Range Guide In order to achieve both 120Hz and 100Hz AC rejection, the integration time needs to be adjusted to coincide with an integer multiple of the AC noise cycle times. To determine a suitable integration time, tint, that will ignore the presence of both 120Hz and 100Hz noise, users can use the formula: tint = n(1/120Hz) = m(1/100Hz), where n and m are integers. n/m = 120Hz/100Hz = 6/5. The first instance of integer values at which tint rejects both 120Hz and 10Hz is when m = 5, and n = 6, thus, tint = 6(1/120Hz) = 5(1/100Hz) = 50ms 15 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Power Supply Decoupling and Layout The power supply lines must be decoupled with capacitors, 4.7uF and 0.1uF, placed as close to the device package as possible. The bypass capacitor should have low effective series resistance (ESR) and effective series inductance (ESI), such as the common ceramic types, which provide a low impedance path to ground at high frequencies to handle transient 2 currents caused by internal logic switching. ALS-PDIC17-57B is relatively insensitive to layout. Like other I C devices, it is intended to provide excellent performance even in significantly noisy environments. There are only a few considerations 2 that will ensure best performance. Route the supply and I C traces as far as possible from all sources of noise. The pull up resister of two line serial bus “SCL” and “SDA” are recommended to be around 4.7Kohm, 2.7V ~ 5.5V Figure 17 Application Circuit 16 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Recommended method of storage 1. Do not open moisture proof bag before devices are ready to use. 2. Shelf life in sealed bag from the bag seal date: 18 months at 10°C~30°C and < 90% RH. 3. After opening the package, the devices must be stored at 10°C~30°C and 60%RH, and used within 168 hours (floor life). 4. If the moisture absorbent material (desiccant material) has faded or unopened bag has exceeded the shelf life or devices (out of bag) have exceeded the floor life, baking treatment is required. 5. If baking is required, refer to IPC/JEDEC J-STD-033 for bake procedure or recommend the following conditions: 312 hours at 40°C and < 5 % RH (reeled/tubed/loose units) or 33 hours at 90°C and < 5 % RH (reeled/tubed/loose units) or 9 hours at 125°C, not suitable for reel or tubes. Recommended Solder Profile Notice: (1) Reflow soldering should not be done more than two times. (2) When soldering, do not put stress on the devices during heating. (3) After soldering, do not warp the circuit board. 17 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Soldering Iron Each terminal is to go to the tip of soldering iron temperature less than 350℃ for 3 seconds within once in less than the soldering iron capacity 25W. Leave two seconds and more intervals, and do soldering of each terminal. Be careful because the damage of the product is often started at the time of the hand solder. Repairing Repair should not be done after the device have been soldered. When repairing is unavoidable, a double-head soldering iron should be used (as below figure). It should be confirmed beforehand whether the characteristics of the device will or will not be damaged by repairing. 18 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Packing Quantity Specification 2000 PCS/ 1 Reel Label Format CPN: Customer’s Production Number P/N: Production Number QTY: Packing Quantity CAT: Ranks HUE: Peak Wavelength REF: Reference LOT No: Lot Number MADE IN TAIWAN: Production Place 19 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Reel Dimensions Unit: mm Tolerance: ± 0.2 Tape Dimensions W E F D0 D1 P0 8.00± 0.2 1.75± 0.1 3.50± 0.05 1.50+0.1/-0 1.00± 0.1 4.00± 0.05 P1 P2 t A0 B0 K0 4.00± 0.1 2.00± 0.05 0.23± 0.05 2.15± 0.05 2.15± 0.05 0.95± 0.05 Unit: mm 20 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever DATASHEET SMD I2C Digital Ambient Light Sensor ALS-PDIC17-57B/TR8 Note: 1. Above specification may be changed without notice. EVERLIGHT will reserve authority on material change for above specification. 2. When using this product, please observe the absolute maximum ratings and the instructions for using outlined in these specification sheets. EVERLIGHT assumes no responsibility for any damage resulting from use of the product which does not comply with the absolute maximum ratings and the instructions included in these specification sheets. 3. These specification sheets include materials protected under copyright of EVERLIGHT corporation. Please don’t reproduce or cause anyone to reproduce them without EVERLIGHT’s consent. 21 Copyright Revision :2 © LifecyclePhase: Date:2013-06-04 08:06:07.0 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:Release DLS-0000049 Rev.2 www.everlight.com Expired Period: Forever