Sanken MPEN-230AF Schottky barrier diode Datasheet

Schottky Barrier Diode
MPEN-230AF
December. 2005
■General Description
■Package---TO-262
High Voltage Schottky Barrier Diode (100V).
The low leakage current and low VF have been achieved by
using the optimum barrier metal.
■Applications
• DC-DC converters
• AC adapter
• High frequency rectification circuit, etc.
■Key Specifications
■Features
• High Voltage 100Vguarantee
• Steady operation is possible even at high temperature with
a low leakage current.
• Ultrafast & low noise switching.
Item
• Low forward voltage drop.
Unit
Rating
VRM
V
100
VF
V
0.90
IF(AV)
A
30
Conditions
IF=15A
Typical Characteristics
IF-VF Characteristics
VR-IR Characteristics
1.0E+02
1.0E-01
Tj=150℃
1.0E-02
1.0E+01
Tj=125℃
1.0E-03
Tj=100℃
IR (A)
IF (A)
1.0E+00
Tj=150℃
1.0E-04
1.0E-01
Tj=125℃
1.0E-05
Tj=100℃
Tj=25℃
1.0E-02
1.0E-06
Tj=25℃
1.0E-03
1.0E-07
0
0.5
1
1.5
0
VF (V)
20
40
60
80
100
VR (V)
.
Sanken Electric Co.,Ltd.
http://www.sanken-ele.co.jp/en/
1/7
D01-006EA-051202
Schottky Barrier Diode
MPEN-230AF
December. 2005
‘ Absolute maximum ratings
No.
Item
Symbol
Unit
Rating
1
Transient Peak Reverse Voltage
VRSM
V
100
2
Peak Reverse Voltage
VRM
V
100
3
Average Forward Current
IF(AV)
A
30
4
Peak Surge Forward Current
IFSM
A
150
5
I2t Limiting Value
I2t
A2s
112.5
6
Junction Temperature
Tj
°C
-40 to +150
7
Storage Temperature
Tstg
°C
-40 to +150
Conditions
Half sinewave, one shot
1msec ≤ t ≤ 10msec
No.1, 2, 4 & 5 show ratings per one chip.
‘ Electrical characteristics (Ta=25°C, unless otherwise specified)
No.
Item
Symbol
Unit
Value
Conditions
1
Forward Voltage Drop
VF
V
0.90 max.
IF=15A
2
Reverse Leakage Current
IR
uA
250 max.
VR=VRM
H•IR
mA
125 max.
VR=VRM, Tj=150°C
Rth(j-c)
°C/W
1.5 max.
3
4
Reverse Leakage Current Under
High Temperature
Thermal Resistance
Between Junction and case
No.1, 2, & 3 show characteristics per one chip.
Sanken Electric Co.,Ltd.
D01-006EA-051202
2/7
Schottky Barrier Diode
MPEN-230AF
December. 2005
‘ Characteristics
Forward Power Dissipation PF (W)
Forward Power Dissipation
Average Forward Current IF(AV) (A)
Reverse Power Dissipation PR (W)
Reverse Power Dissipation
Reverse Voltage VR (V)
Average Forward Current IF(AV) (A)
Current Derating
Case temperature Tc (°C)
Sanken Electric Co.,Ltd.
D01-006EA-051202
3/7
Schottky Barrier Diode
MPEN-230AF
December. 2005
‘ Outline drawings, mm
1
2
3
‘ Connection Diagram
1
2
3
Sanken Electric Co.,Ltd.
D01-006EA-051202
4/7
Schottky Barrier Diode
MPEN-230AF
December. 2005
<Worldwide Contacts>
Asia Pacific
China
Sanken Electric Hong Kong Co., Ltd.
Suite 1026 Ocean Centre, Canton Road, Tsimshatsui, Kowloon, Hong Kong
Tel: 852-2735-5262
Fax: 852-2735-5494
Sanken Electric (Shanghai) Co., Ltd.
Room3202, Maxdo Centre, Xingyi Road 8, Changning district, Shanghai, China
Tel: 86-21-5208-1177
Fax: 86-21-5208-1757
Taiwan Sanken Electric Co., Ltd.
Room 1801, 18th Floor, 88 Jung Shiau East Road, Sec. 2, Taipei 100, Taiwan R.O.C.
Tel: 886-2-2356-8161
Fax: 886-2-2356-8261
India
Saket Devices Pvt. Ltd.
Office No.13, First Floor, Bandal - Dhankude Plaza, Near PMT Depot, Paud Road, Kothrud, Pune - 411 038, India
Tel: 91-20-5621-2340
91-20-2528-5449
Fax: 91-20-2528-5459
Japan
Sanken Electric Co., Ltd. Overseas Sales Headquaters
Metropolitan Plaza Bldg. 1-11-1 Nishi-Ikebukuro, Toshima-ku, Tokyo 171-0021, Japan
Tel: 81-3-3986-6164
Fax: 81-3-3986-8637
Korea
Sanken Electric Korea Co., Ltd.
Mirae Asset Life Bldg. 6F, 168 Kongduk-dong, Mapo-ku, Seoul, 121-705, Korea
Tel: 82-2-714-3700
Fax: 82-2-3272-2145
Singapore
Sanken Electric Singapore Pte. Ltd.
150 Beach Road, #14-03 The Gateway West, Singapore 189720
Tel: 65-6291-4755
Fax: 65-6297-1744
Sanken Electric Co.,Ltd.
D01-006EA-051202
5/7
Schottky Barrier Diode
MPEN-230AF
December. 2005
Europe
United Kingdom
Sanken Power Systems (UK) Limited
Pencoed Technology Park, Pencoed, Bridgend CF35 5HY. UK
Tel: 44-1656-869-100
Fax: 44-1656-869-162
North America
United States
Allegro MicroSystems, Inc.
115 Northeast Cutoff, Worcester, Massachusetts 01606, U.S.A.
Tel: 1-508-853-5000
Fax: 1-508-853-3353
Allegro MicroSystems, Inc. (Southern California)
14 Hughes Street, Suite B105, Irvine, CA 92618
Tel: 1-949-460-2003
Fax: 1-949-460-7837
Sanken Electric Co.,Ltd.
D01-006EA-051202
6/7
Schottky Barrier Diode
MPEN-230AF
December. 2005
CAUTION / WARNING
●The information in this publication has been carefully checked and is believed to be accurate; however, no
responsibility is assumed for inaccuracies.
● Sanken reserves the right to make changes without further notice to any products herein in the interest of
improvements in the performance, reliability, or manufacturability of its products.
Before placing an order, Sanken advises its customers to obtain the latest version of the relevant information to verify
that the information being relied upon is current.
● Application and operation examples described in this catalog are quoted for the sole purpose of reference for the use
of the products herein and Sanken can assume no responsibility for any infringement of industrial property rights,
intellectual property rights or any other rights of Sanken or any third party which may result from its use.
● When using the products herein, the applicability and suitability of such products for the intended purpose or object
shall be reviewed at the users’ responsibility.
● Although Sanken undertakes to enhance the quality and reliability of its products, the occurrence of failure nd defect
of semiconductor products at a certain rate is inevitable. Users of Sanken products are requested to take, at their own
risk, preventative measures including safety design of the equipment or systems against any possible injury, death,
fires or damages to the society due to device failure or malfunction.
● Sanken products listed in this catalog are designed and intended for the use as components in general purpose
electronic equipment or apparatus (home appliances, office equipment, telecommunication equipment, measuring
equipment, etc.). Before placing an order, the user’s written consent to the specifications is requested.
When considering the use of Sanken products in the applications where higher reliability is required (transportation
equipment and its control systems, traffic signal control systems or equipment, fire/crime alarm systems, various
safety devices, etc.), please contact your nearest Sanken sales representative to discuss and obtain written confirmation
of your specifications. The use of Sanken products without the written consent of Sanken in the applications where
extremely high reliability is required (aerospace equipment, nuclear power control systems, life support systems, etc.)
is strictly prohibited.
● Anti radioactive ray design is not considered for the products listed herein.
● This publication shall not be reproduced in whole or in part without prior written approval from Sanken.
●This is notification that you, as purchaser of the products/technology, are not allowed to perform any of the following:
1. Resell or retransfer these products/technology to any party intending to disturb international peace and security.
2. Use these products/technology yourself for activities disturbing international peace and security.
3. Allow any other party to use these products/technology for activities disturbing international peace and security.
Also, as purchaser of these products/technology, you agree to follow the procedures for the export or transfer of these
products/technology, under the Foreign Exchange and Foreign Trade Law, when you export or transfer the
products/technology abroad.
Sanken Electric Co.,Ltd.
D01-006EA-051202
7/7
Similar pages