AD ADUM1201 Dual-channel digital isolator Datasheet

Narrow body, RoHS-compliant, SOIC 8-lead package
Low power operation
5 V operation
1.1 mA per channel maximum @ 0 Mbps to 2 Mbps
3.7 mA per channel maximum @ 10 Mbps
8.2 mA per channel maximum @ 25 Mbps
3 V operation
0.8 mA per channel maximum @ 0 Mbps to 2 Mbps
2.2 mA per channel maximum @ 10 Mbps
4.8 mA per channel maximum @ 25 Mbps
Bidirectional communication
3 V/5 V level translation
High temperature operation: 125°C
High data rate: dc to 25 Mbps (NRZ)
Precise timing characteristics
3 ns maximum pulse width distortion
3 ns maximum channel-to-channel matching
High common-mode transient immunity: >25 kV/μs
Qualified for automotive applications
Safety and regulatory approvals
UL recognition
2500 V rms for 1 minute per UL 1577
CSA Component Acceptance Notice #5A
VDE Certificate of Conformity
DIN V VDE V 0884-10 (VDE V 0884-10): 2006-12
VIORM = 560 V peak
current transfer ratios, nonlinear transfer functions, and temperature and lifetime effects are eliminated with the simple iCoupler
digital interfaces and stable performance characteristics. The need
for external drivers and other discrete components is eliminated
with these iCoupler products. Furthermore, iCoupler devices
consume one-tenth to one-sixth the power of optocouplers at
comparable signal data rates.
The ADuM120x isolators provide two independent isolation
channels in a variety of channel configurations and data rates
(see the Ordering Guide). Both parts operate with the supply
voltage on either side ranging from 2.7 V to 5.5 V, providing
compatibility with lower voltage systems as well as enabling a
voltage translation functionality across the isolation barrier.
In addition, the ADuM120x provide low pulse width distortion
(<3 ns for CR grade) and tight channel-to-channel matching
(<3 ns for CR grade). Unlike other optocoupler alternatives,
the ADuM120x isolators have a patented refresh feature that
ensures dc correctness in the absence of input logic transitions
and during power-up/power-down conditions.
The ADuM1200W and ADuM1201W are automotive grade
versions qualified for 125°C operation. See the Automotive
Products section for more information.
FUNCTIONAL BLOCK DIAGRAMS
VDD1 1
8
VDD2
APPLICATIONS
VIA 2
ENCODE
DECODE
7
VOA
Size-critical multichannel isolation
SPI interface/data converter isolation
RS-232/RS-422/RS-485 transceiver isolation
Digital field bus isolation
Hybrid electric vehicles, battery monitor, and motor drive
VIB 3
ENCODE
DECODE
6
VOB
5
GND2
GENERAL DESCRIPTION
1
The ADuM120x are dual-channel digital isolators based on
the Analog Devices, Inc., iCoupler® technology. Combining
high speed CMOS and monolithic transformer technologies,
these isolation components provide outstanding performance
characteristics superior to alternatives, such as optocouplers.
GND1 4
04642-001
FEATURES
Figure 1. ADuM1200 Functional Block Diagram
VDD1 1
8
VDD2
VOA 2
DECODE
ENCODE
7
VIA
VIB 3
ENCODE
DECODE
6
VOB
5
GND2
GND1 4
04642-002
Data Sheet
Dual-Channel Digital Isolators
ADuM1200/ADuM1201
Figure 2. ADuM1201 Functional Block Diagram
By avoiding the use of LEDs and photodiodes, iCoupler devices
remove the design difficulties commonly associated with optocouplers. The typical optocoupler concerns regarding uncertain
1
Protected by U.S. Patents 5,952,849; 6,873,065; 6,903,578; and 7,075,329.
Rev. I
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113 ©2004–2012 Analog Devices, Inc. All rights reserved.
ADuM1200/ADuM1201
Data Sheet
TABLE OF CONTENTS
Features .............................................................................................. 1
Applications....................................................................................... 1
General Description ......................................................................... 1
Functional Block Diagrams............................................................. 1
Revision History ............................................................................... 3
Specifications..................................................................................... 4
Electrical Characteristics—5 V, 105°C Operation ................... 4
Electrical Characteristics—3 V, 105°C Operation ................... 6
Electrical Characteristics—Mixed 5 V/3 V or 3 V/5 V,
105°C Operation........................................................................... 8
DIN V VDE V 0884-10 (VDE V 0884-10): 2006-12
Insulation Characteristics ......................................................... 20
Recommended Operating Conditions .................................... 20
Absolute Maximum Ratings ......................................................... 21
ESD Caution................................................................................ 21
Pin Configurations and Function Descriptions ......................... 22
Typical Performance Characteristics ........................................... 23
Applications Information .............................................................. 24
PCB Layout ................................................................................. 24
Propagation Delay-Related Parameters................................... 24
Electrical Characteristics—5 V, 125°C Operation ................. 11
DC Correctness and Magnetic Field Immunity........................... 24
Electrical Characteristics—3 V, 125°C Operation ................. 13
Power Consumption .................................................................. 25
Electrical Characteristics—Mixed 5 V/3 V, 125°C Operation 15
Insulation Lifetime ..................................................................... 26
Electrical Characteristics—Mixed 3 V/5 V, 125°C Operation 17
Outline Dimensions ....................................................................... 27
Package Characteristics ............................................................. 19
Ordering Guide .......................................................................... 27
Regulatory Information............................................................. 19
Automotive Products ................................................................. 28
Insulation and Safety-Related Specifications.......................... 19
Rev. I | Page 2 of 28
Data Sheet
ADuM1200/ADuM1201
REVISION HISTORY
3/12—Rev. H to Rev. I
Created Hyperlink for Safety and Regulatory Approvals
Entry in Features Section .................................................................1
Change to General Description Section.........................................1
Change to PCB Layout Section .....................................................24
Moved Automotive Products Section...........................................28
1/09—Rev. G to Rev. H
Changes to Table 5, Switching Specifications Parameter...........13
Changes to Table 6, Switching Specifications Parameter...........15
Changes to Table 7, Switching Specifications Parameter...........17
9/08—Rev. F to Rev. G
Changes to Table 9 ..........................................................................19
Changes to Table 13 ........................................................................21
Changes to Ordering Guide...........................................................27
3/08—Rev. E to Rev. F
Changes to Features Section ............................................................1
Changes to Applications Section.....................................................1
Added Table 4 ..................................................................................11
Added Table 5 ..................................................................................13
Added Table 6 ..................................................................................15
Added Table 7 ..................................................................................17
Changes to Table 12 ........................................................................20
Changes to Table 13 ........................................................................21
Added Automotive Products Section ...........................................26
Changes to Ordering Guide...........................................................27
8/07—Rev. C to Rev. D
Updated VDE Certification Throughout.......................................1
Changes to Features, Note 1, Figure 1, and Figure 2 ....................1
Changes to Table 3 ............................................................................7
Changes to Regulatory Information Section...............................10
Added Table 10 ................................................................................12
Added Insulation Lifetime Section ...............................................16
Updated Outline Dimensions........................................................18
Changes to Ordering Guide...........................................................18
2/06—Rev. B to Rev. C
Updated Format ................................................................. Universal
Added Note 1 .....................................................................................1
Changes to Absolute Maximum Ratings......................................12
Changes to DC Correctness and Magnetic Field
Immunity Section............................................................................15
9/04—Rev. A to Rev. B
Changes to Table 5 ..........................................................................10
6/04—Rev. 0 to Rev. A
Changes to Format............................................................. Universal
Changes to General Description .....................................................1
Changes to Electrical Characteristics—5 V Operation................3
Changes to Electrical Characteristics—3 V Operation................5
Changes to Electrical Characteristics—Mixed 5 V/3 V or
3 V/5 V Operation ............................................................................7
4/04—Revision 0: Initial Version
11/07—Rev. D to Rev. E
Changes to Note 1 .............................................................................1
Added ADuM120xAR Change vs. Temperature Parameter .......3
Added ADuM120xAR Change vs. Temperature Parameter .......5
Added ADuM120xAR Change vs. Temperature Parameter .......8
Rev. I | Page 3 of 28
ADuM1200/ADuM1201
Data Sheet
SPECIFICATIONS
ELECTRICAL CHARACTERISTICS—5 V, 105°C OPERATION
All voltages are relative to their respective ground; 4.5 V ≤ VDD1 ≤ 5.5 V, 4.5 V ≤ VDD2 ≤ 5.5 V; all minimum/maximum specifications apply
over the entire recommended operating range, unless otherwise noted; all typical specifications are at TA = 25°C, VDD1 = VDD2 = 5 V; this
does not apply to the ADuM1200W and ADuM1201W automotive grade products.
Table 1.
Parameter
DC SPECIFICATIONS
Input Supply Current per Channel, Quiescent
Output Supply Current per Channel, Quiescent
ADuM1200 Total Supply Current, Two Channels 1
DC to 2 Mbps
VDD1 Supply Current
VDD2 Supply Current
10 Mbps (BR and CR Grades Only)
VDD1 Supply Current
VDD2 Supply Current
25 Mbps (CR Grade Only)
VDD1 Supply Current
VDD2 Supply Current
ADuM1201 Total Supply Current, Two Channels1
DC to 2 Mbps
VDD1 Supply Current
VDD2 Supply Current
10 Mbps (BR and CR Grades Only)
VDD1 Supply Current
VDD2 Supply Current
25 Mbps (CR Grade Only)
VDD1 Supply Current
VDD2 Supply Current
For All Models
Input Currents
Logic High Input Threshold
Logic Low Input Threshold
Logic High Output Voltages
Logic Low Output Voltages
SWITCHING SPECIFICATIONS
ADuM120xAR
Minimum Pulse Width 2
Maximum Data Rate 3
Propagation Delay 4
Pulse Width Distortion, |tPLH − tPHL|4
Change vs. Temperature
Propagation Delay Skew 5
Channel-to-Channel Matching 6
Output Rise/Fall Time (10% to 90%)
Symbol
Typ
Max
Unit
IDDI (Q)
IDDO (Q)
0.50
0.19
0.60
0.25
mA
mA
IDD1 (Q)
IDD2 (Q)
1.1
0.5
1.4
0.8
mA
mA
DC to 1 MHz logic signal freq.
DC to 1 MHz logic signal freq.
IDD1 (10)
IDD2 (10)
4.3
1.3
5.5
2.0
mA
mA
5 MHz logic signal freq.
5 MHz logic signal freq.
IDD1 (25)
IDD2 (25)
10
2.8
13
3.4
mA
mA
12.5 MHz logic signal freq.
12.5 MHz logic signal freq.
IDD1 (Q)
IDD2 (Q)
0.8
0.8
1.1
1.1
mA
mA
DC to 1 MHz logic signal freq.
DC to 1 MHz logic signal freq.
IDD1 (10)
IDD2 (10)
2.8
2.8
3.5
3.5
mA
mA
5 MHz logic signal freq.
5 MHz logic signal freq.
IDD1 (25)
IDD2 (25)
6.3
6.3
8.0
8.0
mA
mA
12.5 MHz logic signal freq.
12.5 MHz logic signal freq.
−10
0.7 (VDD1 or VDD2)
+0.01
+10
0 V ≤ VIA, VIB ≤ (VDD1 or VDD2)
(VDD1 or VDD2) − 0.1
(VDD1 or VDD2) − 0.5
5.0
4.8
0.0
0.04
0.2
μA
V
V
V
V
V
V
V
IIA, IIB
VIH
VIL
VOAH, VOBH
Min
0.3 (VDD1 or VDD2)
VOAL, VOBL
0.1
0.1
0.4
Test Conditions
IOx = −20 μA, VIx = VIxH
IOx = −4 mA, VIx = VIxH
IOx = 20 μA, VIx = VIxL
IOx = 400 μA, VIx = VIxL
IOx = 4 mA, VIx = VIxL
CL = 15 pF, CMOS signal levels
PW
tPHL, tPLH
PWD
1000
1
50
150
40
11
tPSK
tPSKCD/tPSKOD
tR/tF
100
50
10
Rev. I | Page 4 of 28
ns
Mbps
ns
ns
ps/°C
ns
ns
ns
Data Sheet
ADuM1200/ADuM1201
Parameter
ADuM120xBR
Minimum Pulse Width2
Maximum Data Rate
Symbol
Typ
PW
3
Max
Unit
100
ns
50
ns
3
ns
15
ps/°C
ns
10
Propagation Delay4
tPHL, tPLH
Pulse Width Distortion, |tPLH − tPHL|4
Change vs. Temperature
Propagation Delay Skew5
Channel-to-Channel Matching
Codirectional Channels6
PWD
6
Opposing Directional Channels
Output Rise/Fall Time (10% to 90%)
ADuM120xCR
Minimum Pulse Width2
tPSK
3
tPSKCD
tPSKOD
20
25
Pulse Width Distortion, |tPLH − tPHL|4
Change vs. Temperature
Propagation Delay Skew5
Channel-to-Channel Matching
Codirectional Channels6
PWD
Refresh Rate
Dynamic Supply Current per Channel 8
Input
15
2.5
PW
tPHL, tPLH
Logic Low Output7
ns
tR/tF
Propagation Delay4
Opposing Directional Channels6
Output Rise/Fall Time (10% to 90%)
For All Models
Common-Mode Transient Immunity
Logic High Output 7
Test Conditions
Mbps
20
5
Maximum Data Rate3
Output
Min
40
ns
45
ns
3
ns
15
ps/°C
ns
3
ns
50
20
Mbps
5
tPSK
ns
ns
tPSKCD
tPSKOD
15
tR/tF
ns
2.5
ns
|CMH|
25
35
kV/μs
|CML|
25
35
kV/μs
fr
1.2
Mbps
IDDI (D)
0.19
IDDO (D)
0.05
mA/
Mbps
mA/
Mbps
1
VIx = VDD1 or VDD2, VCM =
1000 V, transient
magnitude = 800 V
VIx = 0 V, VCM = 1000 V,
transient magnitude = 800 V
The supply current values are for both channels combined when running at identical data rates. Output supply current values are specified with no output load
present. The supply current associated with an individual channel operating at a given data rate can be calculated as described in the Power Consumption section. See
Figure 6 through Figure 8 for information on per-channel supply current as a function of data rate for unloaded and loaded conditions. See Figure 9 through Figure 11
for total VDD1 and VDD2 supply currents as a function of data rate for ADuM1200 and ADuM1201 channel configurations.
2
The minimum pulse width is the shortest pulse width at which the specified pulse width distortion is guaranteed.
3
The maximum data rate is the fastest data rate at which the specified pulse width distortion is guaranteed.
4
tPHL propagation delay is measured from the 50% level of the falling edge of the VIx signal to the 50% level of the falling edge of the VOx signal. tPLH propagation delay is
measured from the 50% level of the rising edge of the VIx signal to the 50% level of the rising edge of the VOx signal.
5
tPSK is the magnitude of the worst-case difference in tPHL and/or tPLH that is measured between units at the same operating temperature, supply voltages, and output
load within the recommended operating conditions.
6
Codirectional channel-to-channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on the same side of
the isolation barrier. Opposing directional channel-to-channel matching is the absolute value of the difference in propagation delays between any two channels with
inputs on opposing sides of the isolation barrier.
7
CMH is the maximum common-mode voltage slew rate that can be sustained while maintaining VO > 0.8 VDD2. CML is the maximum common-mode voltage slew rate
that can be sustained while maintaining VO < 0.8 V. The common-mode voltage slew rates apply to both rising and falling common-mode voltage edges. The transient
magnitude is the range over which the common mode is slewed.
8
Dynamic supply current is the incremental amount of supply current required for a 1 Mbps increase in the signal data rate. See Figure 6 through Figure 8 for
information on per-channel supply current as a function of data rate for unloaded and loaded conditions. See the Power Consumption section for guidance on
calculating per-channel supply current for a given data rate.
Rev. I | Page 5 of 28
ADuM1200/ADuM1201
Data Sheet
ELECTRICAL CHARACTERISTICS—3 V, 105°C OPERATION
All voltages are relative to their respective ground; 2.7 V ≤ VDD1 ≤ 3.6 V, 2.7 V ≤ VDD2 ≤ 3.6 V; all minimum/maximum specifications apply
over the entire recommended operating range, unless otherwise noted; all typical specifications are at TA = 25°C, VDD1 = VDD2 = 3.0 V; this
does not apply to ADuM1200W and ADuM1201W automotive grade products.
Table 2.
Parameter
DC SPECIFICATIONS
Input Supply Current per Channel, Quiescent
Output Supply Current per Channel, Quiescent
ADuM1200 Total Supply Current, Two Channels1
DC to 2 Mbps
VDD1 Supply Current
VDD2 Supply Current
10 Mbps (BR and CR Grades Only)
VDD1 Supply Current
VDD2 Supply Current
25 Mbps (CR Grade Only)
VDD1 Supply Current
VDD2 Supply Current
ADuM1201 Total Supply Current, Two Channels1
DC to 2 Mbps
VDD1 Supply Current
VDD2 Supply Current
10 Mbps (BR and CR Grades Only)
VDD1 Supply Current
VDD2 Supply Current
25 Mbps (CR Grade Only)
VDD1 Supply Current
VDD2 Supply Current
For All Models
Input Currents
Logic High Input Threshold
Logic Low Input Threshold
Logic High Output Voltages
Logic Low Output Voltages
SWITCHING SPECIFICATIONS
ADuM120xAR
Minimum Pulse Width2
Maximum Data Rate3
Propagation Delay4
Pulse Width Distortion, |tPLH − tPHL|4
Change vs. Temperature
Propagation Delay Skew5
Channel-to-Channel Matching6
Output Rise/Fall Time (10% to 90%)
Symbol
Typ
Max
Unit
IDDI (Q)
IDDO (Q)
0.26
0.11
0.35
0.20
mA
mA
IDD1 (Q)
IDD2 (Q)
0.6
0.2
1.0
0.6
mA
mA
DC to 1 MHz logic signal freq.
DC to 1 MHz logic signal freq.
IDD1 (10)
IDD2 (10)
2.2
0.7
3.4
1.1
mA
mA
5 MHz logic signal freq.
5 MHz logic signal freq.
IDD1 (25)
IDD2 (25)
5.2
1.5
7.7
2.0
mA
mA
12.5 MHz logic signal freq.
12.5 MHz logic signal freq.
IDD1 (Q)
IDD2 (Q)
0.4
0.4
0.8
0.8
mA
mA
DC to 1 MHz logic signal freq.
DC to 1 MHz logic signal freq.
IDD1 (10)
IDD2 (10)
1.5
1.5
2.2
2.2
mA
mA
5 MHz logic signal freq.
5 MHz logic signal freq.
IDD1 (25)
IDD2 (25)
3.4
3.4
4.8
4.8
mA
mA
12.5 MHz logic signal freq.
12.5 MHz logic signal freq.
−10
0.7 (VDD1 or VDD2)
+0.01
+10
μA
V
0 V ≤ VIA, VIB ≤ (VDD1 or VDD2)
(VDD1 or VDD2) − 0.1
(VDD1 or VDD2) − 0.5
3.0
2.8
0.0
0.04
0.2
V
V
V
V
V
IOx = −20 μA, VIx = VIxH
IOx = −4 mA, VIx = VIxH
IOx = 20 μA, VIx = VIxL
IOx = 400 μA, VIx = VIxL
IOx = 4 mA, VIx = VIxL
IIA, IIB
VIH
VIL
VOAH, VOBH
Min
Test Conditions
0.3 (VDD1 or VDD2)
VOAL, VOBL
0.1
0.1
0.4
CL = 15 pF, CMOS signal levels
PW
tPHL, tPLH
PWD
1000
1
50
150
40
11
tPSK
tPSKCD/tPSKOD
tR/tF
100
50
10
Rev. I | Page 6 of 28
ns
Mbps
ns
ns
ps/°C
ns
ns
ns
Data Sheet
ADuM1200/ADuM1201
Parameter
ADuM120xBR
Minimum Pulse Width2
Symbol
tPHL, tPLH
Pulse Width Distortion, |tPLH − tPHL|4
Change vs. Temperature
Propagation Delay Skew5
Channel-to-Channel Matching
Codirectional Channels6
PWD
Propagation Delay
Pulse Width Distortion, |tPLH − tPHL|4
Change vs. Temperature
Propagation Delay Skew5
Channel-to-Channel Matching
Codirectional Channels6
Opposing Directional Channels6
Output Rise/Fall Time (10% to 90%)
For All Models
Common-Mode Transient Immunity
Logic High Output 7
Logic Low Output7
Refresh Rate
Dynamic Supply Current per Channel 8
Input
Output
Unit
100
ns
20
ns
3
ns
tPSK
22
ps/°C
ns
tPSKCD
3
ns
tPSKOD
22
5
tR/tF
3.0
PW
20
25
tPHL, tPLH
20
ns
ns
40
50
ns
Mbps
55
ns
3
ns
tPSK
16
ps/°C
ns
tPSKCD
3
ns
tPSKOD
16
ns
PWD
5
tR/tF
Test Conditions
CL = 15 pF, CMOS signal levels
Mbps
60
3
4
Max
10
Propagation Delay4
Maximum Data Rate
Typ
PW
Maximum Data Rate3
Opposing Directional Channels6
Output Rise/Fall Time (10% to 90%)
ADuM120xCR
Minimum Pulse Width2
Min
3.0
ns
|CMH|
25
35
kV/μs
|CML|
25
35
kV/μs
fr
1.1
Mbps
IDDI (D)
0.10
IDDO (D)
0.03
mA/
Mbps
mA/
Mbps
1
VIx = VDD1 or VDD2, VCM = 1000 V,
transient magnitude = 800 V
VIx = 0 V, VCM = 1000 V,
transient magnitude = 800 V
The supply current values are for both channels combined when running at identical data rates. Output supply current values are specified with no output load
present. The supply current associated with an individual channel operating at a given data rate can be calculated as described in the Power Consumption section. See
Figure 6 through Figure 8 for information on per-channel supply current as a function of data rate for unloaded and loaded conditions. See Figure 9 through Figure 11
for total VDD1 and VDD2 supply currents as a function of data rate for ADuM1200 and ADuM1201 channel configurations.
2
The minimum pulse width is the shortest pulse width at which the specified pulse width distortion is guaranteed.
3
The maximum data rate is the fastest data rate at which the specified pulse width distortion is guaranteed.
4
tPHL propagation delay is measured from the 50% level of the falling edge of the VIx signal to the 50% level of the falling edge of the VOx signal. tPLH propagation delay is
measured from the 50% level of the rising edge of the VIx signal to the 50% level of the rising edge of the VOx signal.
5
tPSK is the magnitude of the worst-case difference in tPHL and/or tPLH that is measured between units at the same operating temperature, supply voltages, and output
load within the recommended operating conditions.
6
Codirectional channel-to-channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on the same side of
the isolation barrier. Opposing directional channel-to-channel matching is the absolute value of the difference in propagation delays between any two channels with
inputs on opposing sides of the isolation barrier.
7
CMH is the maximum common-mode voltage slew rate that can be sustained while maintaining VO > 0.8 VDD2. CML is the maximum common-mode voltage slew rate
that can be sustained while maintaining VO < 0.8 V. The common-mode voltage slew rates apply to both rising and falling common-mode voltage edges. The transient
magnitude is the range over which the common mode is slewed.
8
Dynamic supply current is the incremental amount of supply current required for a 1 Mbps increase in the signal data rate. See Figure 6 through Figure 8 for
information on per-channel supply current as a function of data rate for unloaded and loaded conditions. See the Power Consumption section for guidance on
calculating per-channel supply current for a given data rate.
Rev. I | Page 7 of 28
ADuM1200/ADuM1201
Data Sheet
ELECTRICAL CHARACTERISTICS—MIXED 5 V/3 V OR 3 V/5 V, 105°C OPERATION
All voltages are relative to their respective ground; 5 V/3 V operation: 4.5 V ≤ VDD1 ≤ 5.5 V, 2.7 V ≤ VDD2 ≤ 3.6 V. 3 V/5 V operation:
2.7 V ≤ VDD1 ≤ 3.6 V, 4.5 V ≤ VDD2 ≤ 5.5 V; all minimum/maximum specifications apply over the entire recommended operating range,
unless otherwise noted; all typical specifications are at TA = 25°C; VDD1 = 3.0 V, VDD2 = 5.0 V; or VDD1 = 5.0 V, VDD2 = 3.0 V; this does not
apply to ADuM1200W and ADuM1201W automotive grade products.
Table 3.
Parameter
DC SPECIFICATIONS
Input Supply Current per Channel,
Quiescent
5 V/3 V Operation
3 V/5 V Operation
Output Supply Current per Channel,
Quiescent
5 V/3 V Operation
3 V/5 V Operation
ADuM1200 Total Supply Current,
Two Channels1
DC to 2 Mbps
VDD1 Supply Current
5 V/3 V Operation
3 V/5 V Operation
VDD2 Supply Current
5 V/3 V Operation
3 V/5 V Operation
10 Mbps (BR and CR Grades Only)
VDD1 Supply Current
5 V/3 V Operation
3 V/5 V Operation
VDD2 Supply Current
5 V/3 V Operation
3 V/5 V Operation
25 Mbps (CR Grade Only)
VDD1 Supply Current
5 V/3 V Operation
3 V/5 V Operation
VDD2 Supply Current
5 V/3 V Operation
3 V/5 V Operation
ADuM1201 Total Supply Current,
Two Channels1
DC to 2 Mbps
VDD1 Supply Current
5 V/3 V Operation
3 V/5 V Operation
VDD2 Supply Current
5 V/3 V Operation
3 V/5 V Operation
10 Mbps (BR and CR Grades Only)
VDD1 Supply Current
5 V/3 V Operation
3 V/5 V Operation
VDD2 Supply Current
5 V/3 V Operation
3 V/5 V Operation
Symbol
Min
Typ
Max
Unit
Test Conditions
0.50
0.26
0.6
0.35
mA
mA
0.11
0.19
0.20
0.25
mA
mA
1.1
0.6
1.4
1.0
mA
mA
DC to 1 MHz logic signal freq.
DC to 1 MHz logic signal freq.
0.2
0.5
0.6
0.8
mA
mA
DC to 1 MHz logic signal freq.
DC to 1 MHz logic signal freq.
4.3
2.2
5.5
3.4
mA
mA
5 MHz logic signal freq.
5 MHz logic signal freq.
0.7
1.3
1.1
2.0
mA
mA
5 MHz logic signal freq.
5 MHz logic signal freq.
10
5.2
13
7.7
mA
mA
12.5 MHz logic signal freq.
12.5 MHz logic signal freq.
1.5
2.8
2.0
3.4
mA
mA
12.5 MHz logic signal freq.
12.5 MHz logic signal freq.
0.8
0.4
1.1
0.8
mA
mA
DC to 1 MHz logic signal freq.
DC to 1 MHz logic signal freq.
0.4
0.8
0.8
1.1
mA
mA
DC to 1 MHz logic signal freq.
DC to 1 MHz logic signal freq.
2.8
1.5
3.5
2.2
mA
mA
5 MHz logic signal freq.
5 MHz logic signal freq.
1.5
2.8
2.2
3.5
mA
mA
5 MHz logic signal freq.
5 MHz logic signal freq.
IDDI (Q)
IDDO (Q)
IDD1 (Q)
IDD2 (Q)
IDD1 (10)
IDD2 (10)
IDD1 (25)
IDD2 (25)
IDD1 (Q)
IDD2 (Q)
IDD1 (10)
IDD2 (10)
Rev. I | Page 8 of 28
Data Sheet
ADuM1200/ADuM1201
Parameter
25 Mbps (CR Grade Only)
VDD1 Supply Current
5 V/3 V Operation
3 V/5 V Operation
VDD2 Supply Current
5 V/3 V Operation
3 V/5 V Operation
For All Models
Input Currents
Logic High Input Threshold
Logic Low Input Threshold
Logic High Output Voltages
Symbol
IIA, IIB
VIH
VIL
VOAH, VOBH
Logic Low Output Voltages
VOAL, VOBL
Typ
Max
Unit
Test Conditions
6.3
3.4
8.0
4.8
mA
mA
12.5 MHz logic signal freq.
12.5 MHz logic signal freq.
3.4
6.3
4.8
8.0
mA
mA
12.5 MHz logic signal freq.
12.5 MHz logic signal freq.
−10
0.7 (VDD1 or VDD2)
+0.01
+10
0 V ≤ VIA, VIB ≤ (VDD1 or VDD2)
(VDD1 or VDD2) − 0.1
(VDD1 or VDD2) − 0.5
VDD1 or VDD2
(VDD1 or VDD2) − 0.2
0.0
0.04
0.2
μA
V
V
V
V
V
V
V
IDD1 (25)
IDD2 (25)
SWITCHING SPECIFICATIONS
ADuM120xAR
Minimum Pulse Width 2
Maximum Data Rate 3
Propagation Delay 4
Pulse Width Distortion, |tPLH − tPHL|4
Change vs. Temperature
Propagation Delay Skew 5
Channel-to-Channel Matching 6
Output Rise/Fall Time (10% to 90%)
ADuM120xBR
Minimum Pulse Width2
0.3 (VDD1 or VDD2)
0.1
0.1
0.4
tPHL, tPLH
PWD
1000
1
50
150
40
11
tPSK
tPSKCD/tPSKOD
tR/tF
ps/°C
ns
ns
ns
100
ns
10
CL = 15 pF, CMOS signal levels
PW
tPHL, tPLH
4
ns
Mbps
ns
ns
50
50
10
4
IOx = −20 μA, VIx = VIxH
IOx = −4 mA, VIx = VIxH
IOx = 20 μA, VIx = VIxL
IOx = 400 μA, VIx = VIxL
IOx = 4 mA, VIx = VIxL
CL = 15 pF, CMOS signal levels
PW
Maximum Data Rate3
Propagation Delay
Min
Mbps
15
55
ns
3
ns
22
ps/°C
ns
Pulse Width Distortion, |tPLH − tPHL|
Change vs. Temperature
Propagation Delay Skew5
Channel-to-Channel Matching
Codirectional Channels6
PWD
tPSKCD
3
ns
Opposing Directional Channels6
Output Rise/Fall Time (10% to 90%)
5 V/3 V Operation
3 V/5 V Operation
ADuM120xCR
Minimum Pulse Width2
tPSKOD
22
ns
5
tPSK
tR/tF
3.0
2.5
ns
ns
CL = 15 pF, CMOS signal levels
PW
Maximum Data Rate3
20
25
40
ns
50
ns
3
ns
15
ps/°C
ns
50
Mbps
Propagation Delay4
tPHL, tPLH
Pulse Width Distortion, |tPLH − tPHL|4
Change vs. Temperature
Propagation Delay Skew5
Channel-to-Channel Matching
Codirectional Channels6
PWD
tPSKCD
3
ns
Opposing Directional Channels6
Output Rise/Fall Time (10% to 90%)
5 V/3 V Operation
3 V/5 V Operation
tPSKOD
15
ns
20
5
tPSK
tR/tF
3.0
2.5
Rev. I | Page 9 of 28
ns
ns
ADuM1200/ADuM1201
Parameter
For All Models
Common-Mode Transient Immunity
Logic High Output 7
Logic Low Output7
Refresh Rate
5 V/3 V Operation
3 V/5 V Operation
Input Dynamic Supply Current
per Channel 8
5 V/3 V Operation
Data Sheet
Symbol
Min
Typ
|CMH|
25
|CML|
25
3 V/5 V Operation
Unit
Test Conditions
35
kV/μs
35
kV/μs
VIx = VDD1 or VDD2, VCM = 1000 V,
transient magnitude = 800 V
VIx = 0 V, VCM = 1000 V,
transient magnitude = 800 V
1.2
1.1
Mbps
Mbps
0.19
mA/
Mbps
mA/
Mbps
fr
IDDI (D)
3 V/5 V Operation
Output Dynamic Supply Current per
Channel8
5 V/3 V Operation
Max
0.10
IDDO (D)
0.03
0.05
1
mA/
Mbps
mA/
Mbps
The supply current values are for both channels combined when running at identical data rates. Output supply current values are specified with no output load
present. The supply current associated with an individual channel operating at a given data rate can be calculated as described in the Power Consumption section. See
Figure 6 through Figure 8 for information on per-channel supply current as a function of data rate for unloaded and loaded conditions. See Figure 9 through Figure 11
for total VDD1 and VDD2 supply currents as a function of data rate for ADuM1200 and ADuM1201 channel configurations.
2
The minimum pulse width is the shortest pulse width at which the specified pulse width distortion is guaranteed.
3
The maximum data rate is the fastest data rate at which the specified pulse width distortion is guaranteed.
4
tPHL propagation delay is measured from the 50% level of the falling edge of the VIx signal to the 50% level of the falling edge of the VOx signal. tPLH propagation delay is
measured from the 50% level of the rising edge of the VIx signal to the 50% level of the rising edge of the VOx signal.
5
tPSK is the magnitude of the worst-case difference in tPHL and/or tPLH that is measured between units at the same operating temperature, supply voltages, and output
load within the recommended operating conditions.
6
Codirectional channel-to-channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on the same side of
the isolation barrier. Opposing directional channel-to-channel matching is the absolute value of the difference in propagation delays between any two channels with
inputs on opposing sides of the isolation barrier.
7
CMH is the maximum common-mode voltage slew rate that can be sustained while maintaining VO > 0.8 VDD2. CML is the maximum common-mode voltage slew rate
that can be sustained while maintaining VO < 0.8 V. The common-mode voltage slew rates apply to both rising and falling common-mode voltage edges. The transient
magnitude is the range over which the common mode is slewed.
8
Dynamic supply current is the incremental amount of supply current required for a 1 Mbps increase in the signal data rate. See Figure 6 through Figure 8 for
information on per-channel supply current as a function of data rate for unloaded and loaded conditions. See the Power Consumption section for guidance on
calculating per-channel supply current for a given data rate.
Rev. I | Page 10 of 28
Data Sheet
ADuM1200/ADuM1201
ELECTRICAL CHARACTERISTICS—5 V, 125°C OPERATION
All voltages are relative to their respective ground; 4.5 V ≤ VDD1 ≤ 5.5 V, 4.5 V ≤ VDD2 ≤ 5.5 V; all minimum/maximum specifications apply
over the entire recommended operating range, unless otherwise noted; all typical specifications are at TA = 25°C, VDD1 = VDD2 = 5 V; this
applies to ADuM1200W and ADuM1201W automotive grade products.
Table 4.
Parameter
DC SPECIFICATIONS
Input Supply Current per Channel,
Quiescent
Output Supply Current per Channel,
Quiescent
ADVM1200W, Total Supply Current,
Two Channels 1
DC to 2 Mbps
VDD1 Supply Current
VDD2 Supply Current
10 Mbps (TRZ and URZ Grades Only)
VDD1 Supply Current
VDD2 Supply Current
25 Mbps (URZ Grade Only)
VDD1 Supply Current
VDD2 Supply Current
ADVM1201W, Total Supply Current,
Two Channels1
DC to 2 Mbps
VDD1 Supply Current
VDD2 Supply Current
10 Mbps (TRZ and URZ Grades Only)
VDD1 Supply Current
VDD2 Supply Current
25 Mbps (URZ Grade Only)
VDD1 Supply Current
VDD2 Supply Current
For All Models
Input Currents
Logic High Input Threshold
Logic Low Input Threshold
Logic High Output Voltages
Logic Low Output Voltages
SWITCHING SPECIFICATIONS
ADuM120xWSRZ
Minimum Pulse Width 2
Maximum Data Rate 3
Propagation Delay 4
Pulse Width Distortion, |tPLH − tPHL|4
Propagation Delay Skew 5
Channel-to-Channel Matching 6
Output Rise/Fall Time (10% to 90%)
Symbol
Typ
Max
Unit
IDDI (Q)
0.50
0.60
mA
IDDO (Q)
0.19
0.25
mA
IDD1 (Q)
IDD2 (Q)
1.1
0.5
1.4
0.8
mA
mA
DC to 1 MHz logic signal freq.
DC to 1 MHz logic signal freq.
IDD1 (10)
IDD2 (10)
4.3
1.3
5.5
2.0
mA
mA
5 MHz logic signal freq.
5 MHz logic signal freq.
IDD1 (25)
IDD2 (25)
10
2.8
13
3.4
mA
mA
12.5 MHz logic signal freq.
12.5 MHz logic signal freq.
IDD1 (Q)
IDD2 (Q)
0.8
0.8
1.1
1.1
mA
mA
DC to 1 MHz logic signal freq.
DC to 1 MHz logic signal freq.
IDD1 (10)
IDD2 (10)
2.8
2.8
3.5
3.5
mA
mA
5 MHz logic signal freq.
5 MHz logic signal freq.
IDD1 (25)
IDD2 (25)
6.3
6.3
8.0
8.0
mA
mA
12.5 MHz logic signal freq.
12.5 MHz logic signal freq.
−10
0.7 (VDD1 or VDD2)
+0.01
+10
0 7≤ VIA, VIB ≤ (VDD1 or VDD2)
(VDD1 or VDD2) − 0.1
(VDD1 or VDD2) − 0.5
5.0
4.8
0.0
0.04
0.2
μA
V
V
V
V
V
V
V
IIA, IIB
VIH
VIL
VOAH, VOBH
Min
0.3 (VDD1 or VDD2)
VOAL, VOBL
0.1
0.1
0.4
Test Conditions
IOx = −20 μA, VIx = VIxH
IOx = −4 mA, VIx = VIxH
IOx = 20 μA, VIx = VIxL
IOx = 400 μA, VIx = VIxL
IOx = 4 mA, VIx = VIxL
CL = 15 pF, CMOS signal levels
PW
tPHL, tPLH
PWD
tPSK
tPSKCD/tPSKOD
tR/tF
1000
1
20
150
40
100
50
2.5
Rev. I | Page 11 of 28
ns
Mbps
ns
ns
ns
ns
ns
ADuM1200/ADuM1201
Parameter
ADuM120xWTRZ
Minimum Pulse Width2
Data Sheet
Symbol
Min
Typ
PW
Maximum Data Rate3
Max
Unit
100
ns
50
ns
3
ns
15
ps/°C
ns
10
Mbps
Propagation Delay4
tPHL, tPLH
Pulse Width Distortion, |tPLH − tPHL|4
Change vs. Temperature
Propagation Delay Skew5
Channel-to-Channel Matching
Codirectional Channels6
PWD
tPSKCD
3
ns
Opposing Directional Channels6
Output Rise/Fall Time (10% to 90%)
ADuM120xWURZ
Minimum Pulse Width2
tPSKOD
15
ns
Propagation Delay
20
5
tPSK
tR/tF
2.5
PW
20
ns
CL = 15 pF, CMOS signal levels
Maximum Data Rate3
4
25
tPHL, tPLH
40
50
20
ns
Mbps
45
ns
3
ns
15
ps/°C
ns
Pulse Width Distortion, |tPLH − tPHL|4
Change vs. Temperature
Propagation Delay Skew5
Channel-to-Channel Matching
Codirectional Channels6
PWD
tPSKCD
3
ns
Opposing Directional Channels6
Output Rise/Fall Time (10% to 90%)
For All Models
Common-Mode Transient Immunity
Logic High Output7
tPSKOD
15
ns
Logic Low Output7
Refresh Rate
Dynamic Supply Current per Channel8
Input
Output
Test Conditions
CL = 15 pF, CMOS signal levels
5
tPSK
tR/tF
2.5
ns
|CMH|
25
35
kV/μs
|CML|
25
35
kV/μs
fr
1.2
Mbps
IDDI (D)
0.19
IDDO (D)
0.05
mA/
Mbps
mA/
Mbps
1
VIx = VDD1, VDD2, VCM = 1000 V,
transient magnitude = 800 V
VIx = 0 V, VCM = 1000 V,
transient magnitude = 800 V
The supply current values are for both channels combined when running at identical data rates. Output supply current values are specified with no output load
present. The supply current associated with an individual channel operating at a given data rate can be calculated as described in the Power Consumption section. See
Figure 6 through Figure 8 for information on per-channel supply current as a function of data rate for unloaded and loaded conditions. See Figure 9 through Figure 11
for total IDD1 and IDD2 supply currents as a function of data rate for ADuM1200W and ADuM1201W channel configurations.
2
The minimum pulse width is the shortest pulse width at which the specified pulse width distortion is guaranteed.
3
The maximum data rate is the fastest data rate at which the specified pulse width distortion is guaranteed.
4
tPHL propagation delay is measured from the 50% level of the falling edge of the VIx signal to the 50% level of the falling edge of the VOx signal. tPLH propagation delay is
measured from the 50% level of the rising edge of the VIx signal to the 50% level of the rising edge of the VOx signal.
5
tPSK is the magnitude of the worst-case difference in tPHL and/or tPLH that is measured between units at the same operating temperature, supply voltages, and output
load within the recommended operating conditions.
6
Codirectional channel-to-channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on the same side of
the isolation barrier. Opposing directional channel-to-channel matching is the absolute value of the difference in propagation delays between any two channels with
inputs on opposing sides of the isolation barrier.
7
CMH is the maximum common-mode voltage slew rate that can be sustained while maintaining VO > 0.8 VDD2. CML is the maximum common-mode voltage slew rate
that can be sustained while maintaining VO < 0.8 V. The common-mode voltage slew rates apply to both rising and falling common-mode voltage edges. The transient
magnitude is the range over which the common mode is slewed.
8
Dynamic supply current is the incremental amount of supply current required for a 1 Mbps increase in the signal data rate. See Figure 6 through Figure 8 for
information on per-channel supply current as a function of data rate for unloaded and loaded conditions. See the Power Consumption section for guidance on
calculating per-channel supply current for a given data rate.
Rev. I | Page 12 of 28
Data Sheet
ADuM1200/ADuM1201
ELECTRICAL CHARACTERISTICS—3 V, 125°C OPERATION
All voltages are relative to their respective ground; 3.0 V ≤ VDD1 ≤ 3.6 V, 3.0 V ≤ VDD2 ≤ 3.6 V. All minimum/maximum specifications apply
over the entire recommended operating range, unless otherwise noted; all typical specifications are at TA = 25°C, VDD1 = VDD2 = 3.0 V;
this applies to ADuM1200W and ADuM1201W automotive grade products.
Table 5.
Parameter
DC SPECIFICATIONS
Input Supply Current per Channel,
Quiescent
Output Supply Current per Channel, Quiescent
ADVM1200W, Total Supply Current,
Two Channels 1
DC to 2 Mbps
VDD1 Supply Current
VDD2 Supply Current
10 Mbps (TRZ and URZ Grades Only)
VDD1 Supply Current
VDD2 Supply Current
25 Mbps (URZ Grade Only)
VDD1 Supply Current
VDD2 Supply Current
ADVM1201W, Total Supply Current,
Two Channels1
DC to 2 Mbps
VDD1 Supply Current
VDD2 Supply Current
10 Mbps (TRZ and URZ Grades Only)
VDD1 Supply Current
VDD2 Supply Current
25 Mbps (URZ Grade Only)
VDD1 Supply Current
VDD2 Supply Current
For All Models
Input Currents
Logic High Input Threshold
Logic Low Input Threshold
Logic High Output Voltages
Logic Low Output Voltages
SWITCHING SPECIFICATIONS
ADuM120xWSRZ
Minimum Pulse Width 2
Maximum Data Rate 3
Propagation Delay 4
Pulse Width Distortion, |tPLH − tPHL|4
Propagation Delay Skew 5
Channel-to-Channel Matching 6
Output Rise/Fall Time (10% to 90%)
Symbol
Typ
Max
Unit
IDDI (Q)
0.26
0.35
mA
IDDO (Q)
0.11
0.20
mA
IDD1 (Q)
IDD2 (Q)
0.6
0.2
1.0
0.6
mA
mA
DC to 1 MHz logic signal freq.
DC to 1 MHz logic signal freq.
IDD1 (10)
IDD2 (10)
2.2
0.7
3.4
1.1
mA
mA
5 MHz logic signal freq.
5 MHz logic signal freq.
IDD1 (25)
IDD2 (25)
5.2
1.5
7.7
2.0
mA
mA
12.5 MHz logic signal freq.
12.5 MHz logic signal freq.
IDD1 (Q)
IDD2 (Q)
0.4
0.4
0.8
0.8
mA
mA
DC to 1 MHz logic signal freq.
DC to 1 MHz logic signal freq.
IDD1 (10)
IDD2 (10)
1.5
1.5
2.2
2.2
mA
mA
5 MHz logic signal freq.
5 MHz logic signal freq.
IDD1 (25)
IDD2 (25)
3.4
3.4
4.8
4.8
mA
mA
12.5 MHz logic signal freq.
12.5 MHz logic signal freq.
−10
0.7 (VDD1 or VDD2)
+0.01
+10
μA
V
0 7≤ VIA, VIB ≤ (VDD1 or VDD2)
(VDD1 or VDD2) − 0.1
(VDD1 or VDD2) − 0.5
3.0
2.8
0.0
0.04
0.2
V
V
V
V
V
IOx = −20 μA, VIx = VIxH
IOx = −4 mA, VIx = VIxH
IOx = 20 μA, VIx = VIxL
IOx = 400 μA, VIx = VIxL
IOx = 4 mA, VIx = VIxL
IIA, IIB
VIH
VIL
VOAH, VOBH
Min
Test Conditions
0.3 (VDD1 or VDD2)
VOAL, VOBL
0.1
0.1
0.4
CL = 15 pF, CMOS signal levels
PW
tPHL, tPLH
PWD
1000
1
20
150
40
tPSK
tPSKCD/tPSKOD
tR/tF
100
50
3
Rev. I | Page 13 of 28
ns
Mbps
ns
ns
ns
ns
ns
ADuM1200/ADuM1201
Parameter
Data Sheet
Symbol
ADuM120xWTRZ
Minimum Pulse Width2
Unit
100
ns
10
tPHL, tPLH
4
Test Conditions
Mbps
20
PWD
60
ns
3
ns
22
ps/°C
ns
5
tPSK
Opposing Directional Channels6
Output Rise/Fall Time (10% to 90%)
ADuM120xWCR
Minimum Pulse Width2
tPSKCD
3
ns
tPSKOD
22
ns
tR/tF
3.0
PW
20
CL = 15 pF, CMOS signal levels
ns
55
ns
3
ns
tPSK
16
ps/°C
ns
tPSKCD
3
ns
25
Propagation Delay4
tPHL, tPLH
Pulse Width Distortion, |tPLH − tPHL|4
Change vs. Temperature
Propagation Delay Skew5
Channel-to-Channel Matching
Codirectional Channels6
PWD
6
Opposing Directional Channels
Output Rise/Fall Time (10% to 90%)
For All Models
Common-Mode Transient Immunity
Logic High Output7
Logic Low Output7
Refresh Rate
Dynamic Supply Current per Channel8
Input
ns
40
Maximum Data Rate3
Output
Max
CL = 15 pF, CMOS signal levels
4
Pulse Width Distortion, |tPLH − tPHL|
Change vs. Temperature
Propagation Delay Skew5
Channel-to-Channel Matching
Codirectional Channels6
Typ
PW
Maximum Data Rate3
Propagation Delay
Min
50
20
Mbps
5
tPSKOD
16
tR/tF
ns
3.0
ns
|CMH|
25
35
kV/μs
|CML|
25
35
kV/μs
fr
1.1
Mbps
IDDI (D)
0.10
IDDO (D)
0.03
mA/
Mbps
mA/
Mbps
1
VIx = VDD1, VDD2, VCM = 1000 V,
transient magnitude = 800 V
VIx = 0 V, VCM = 1000 V,
transient magnitude = 800 V
The supply current values are for both channels combined when running at identical data rates. Output supply current values are specified with no output load
present. The supply current associated with an individual channel operating at a given data rate can be calculated as described in the Power Consumption section. See
Figure 6 through Figure 8 for information on per-channel supply current as a function of data rate for unloaded and loaded conditions. See Figure 9 through Figure 11
for total IDD1 and IDD2 supply currents as a function of data rate for ADuM1200W and ADuM1201W channel configurations.
2
The minimum pulse width is the shortest pulse width at which the specified pulsewidth distortion is guaranteed.
3
The maximum data rate is the fastest data rate at which the specified pulsewidth distortion is guaranteed.
4
tPHL propagation delay is measured from the 50% level of the falling edge of the VIx signal to the 50% level of the falling edge of the VOx signal. tPLH propagation delay is
measured from the 50% level of the rising edge of the VIx signal to the 50% level of the rising edge of the VOx signal.
5
tPSK is the magnitude of the worst-case difference in tPHL and/or tPLH that is measured between units at the same operating temperature, supply voltages, and output
load within the recommended operating conditions.
6
Codirectional channel-to-channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on the same side of
the isolation barrier. Opposing directional channel-to-channel matching is the absolute value of the difference in propagation delays between any two channels with
inputs on opposing sides of the isolation barrier.
7
CMH is the maximum common-mode voltage slew rate that can be sustained while maintaining VO > 0.8 VDD2. CML is the maximum common-mode voltage slew rate
that can be sustained while maintaining VO < 0.8 V. The common-mode voltage slew rates apply to both rising and falling common-mode voltage edges. The transient
magnitude is the range over which the common mode is slewed.
8
Dynamic supply current is the incremental amount of supply current required for a 1 Mbps increase in the signal data rate. See Figure 6 through Figure 8 for
information on per-channel supply current as a function of data rate for unloaded and loaded conditions. See the Power Consumption section for guidance on
calculating per-channel supply current for a given data rate.
Rev. I | Page 14 of 28
Data Sheet
ADuM1200/ADuM1201
ELECTRICAL CHARACTERISTICS—MIXED 5 V/3 V, 125°C OPERATION
All voltages are relative to their respective ground; 5 V/3 V operation: 4.5 V ≤ VDD1 ≤ 5.5 V, 3.0 V ≤ VDD2 ≤ 3.6 V. 3 V/5 V operation; all
minimum/maximum specifications apply over the entire recommended operating range, unless otherwise noted; all typical specifications
are at TA = 25°C; VDD1 = 5.0 V, VDD2 = 3.0 V; this applies to ADuM1200W and ADuM1201W automotive grade products.
Table 6.
Parameter
DC SPECIFICATIONS
Input Supply Current per Channel,
Quiescent
Output Supply Current per Channel,
Quiescent
ADuM1200W, Total Supply Current,
Two Channels1
DC to 2 Mbps
VDD1 Supply Current
VDD2 Supply Current
10 Mbps (TRZ and URZ Grades Only)
VDD1 Supply Current
VDD2 Supply Current
25 Mbps (URZ Grade Only)
VDD1 Supply Current
VDD2 Supply Current
ADuM1201W, Total Supply Current,
Two Channels1
DC to 2 Mbps
VDD1 Supply Current
VDD2 Supply Current
10 Mbps (TRZ and URZ Grades Only)
VDD1 Supply Current
VDD2 Supply Current
25 Mbps (URZ Grade Only)
VDD1 Supply Current
VDD2 Supply Current
For All Models
Input Currents
Logic High Input Threshold
Logic Low Input Threshold
Logic High Output Voltages
Logic Low Output Voltages
SWITCHING SPECIFICATIONS
ADuM120xWSRZ
Minimum Pulse Width2
Maximum Data Rate3
Propagation Delay4
Pulse Width Distortion, |tPLH − tPHL|4
Propagation Delay Skew5
Channel-to-Channel Matching6
Output Rise/Fall Time (10% to 90%)
Symbol
Typ
Max
Unit
IDDI (Q)
0.50
0.6
mA
IDDO (Q)
0.11
0.20
mA
IDD1 (Q)
IDD2 (Q)
1.1
0.2
1.4
0.6
mA
mA
DC to 1 MHz logic signal freq.
DC to 1 MHz logic signal freq.
IDD1 (10)
IDD2 (10)
4.3
0.7
5.5
1.1
mA
mA
5 MHz logic signal freq.
5 MHz logic signal freq.
IDD1 (25)
IDD2 (25)
10
1.5
13
2.0
mA
mA
12.5 MHz logic signal freq.
12.5 MHz logic signal freq.
IDD1 (Q)
IDD2 (Q)
0.8
0.4
1.1
0.8
mA
mA
DC to 1 MHz logic signal freq.
DC to 1 MHz logic signal freq.
IDD1 (10)
IDD2 (10)
2.8
1.5
3.5
2.2
mA
mA
5 MHz logic signal freq.
5 MHz logic signal freq.
IDD1 (25)
IDD2 (25)
6.3
3.4
8.0
4.8
mA
mA
12.5 MHz logic signal freq.
12.5 MHz logic signal freq.
−10
0.7 (VDD1 or VDD2)
+0.01
+10
0 V ≤ VIA, VIB ≤ (VDD1 or VDD2)
(VDD1 or VDD2) − 0.1
(VDD1 or VDD2) − 0.5
VDD1 or VDD2
(VDD1 or VDD2) − 0.2
0.0
0.04
0.2
μA
V
V
V
V
V
V
V
IIA, IIB
VIH
VIL
VOAH, VOBH
Min
0.3 (VDD1 or VDD2)
VOAL, VOBL
0.1
0.1
0.4
Test Conditions
IOx = −20 μA, VIx = VIxH
IOx = −4 mA, VIx = VIxH
IOx = 20 μA, VIx = VIxL
IOx = 400 μA, VIx = VIxL
IOx = 4 mA, VIx = VIxL
CL = 15 pF, CMOS signal levels
PW
tPHL, tPLH
PWD
tPSK
tPSKCD/ tPSKOD
tR/tF
1000
1
15
150
40
50
50
3
Rev. I | Page 15 of 28
ns
Mbps
ns
ns
ns
ns
ns
ADuM1200/ADuM1201
Parameter
Data Sheet
Symbol
ADuM120xWTRZ
Minimum Pulse Width2
Typ
Max
Unit
100
ns
10
4
tPHL, tPLH
Pulse Width Distortion, |tPLH − tPHL|4
Change vs. Temperature
Propagation Delay Skew5
Channel-to-Channel Matching
Codirectional Channels6
6
Opposing Directional Channels
Output Rise/Fall Time (10% to 90%)
ADuM120xWURZ
Minimum Pulse Width2
Mbps
15
55
ns
3
ns
tPSK
22
ps/°C
ns
tPSKCD
3
ns
tPSKOD
22
ns
PWD
5
tR/tF
3.0
PW
20
ns
CL = 15 pF, CMOS signal levels
40
ns
50
ns
3
ns
tPSK
15
ps/°C
ns
ns
Maximum Data Rate3
25
50
Mbps
Propagation Delay4
tPHL, tPLH
Pulse Width Distortion, |tPLH − tPHL|4
Change vs. Temperature
Propagation Delay Skew5
Channel-to-Channel Matching
Codirectional Channels6
PWD
tPSKCD
3
Opposing Directional Channels6
Output Rise/Fall Time (10% to 90%)
For All Models
Common-Mode Transient Immunity
Logic High Output7
tPSKOD
15
Logic Low Output7
Refresh Rate
Dynamic Supply Current per Channel8
Input
Output
Test Conditions
CL = 15 pF, CMOS signal levels
PW
Maximum Data Rate3
Propagation Delay
Min
20
5
tR/tF
ns
3.0
ns
|CMH|
25
35
kV/μs
|CML|
25
35
kV/μs
fr
1.2
Mbps
IDDI (D)
0.19
IDDO (D)
0.03
mA/
Mbps
mA/
Mbps
1
VIx = VDD1, VDD2, VCM = 1000 V,
transient magnitude = 800 V
VIx = VDD1, VDD2, VCM = 1000 V,
transient magnitude = 800 V
The supply current values are for both channels combined when running at identical data rates. Output supply current values are specified with no output load
present. The supply current associated with an individual channel operating at a given data rate can be calculated as described in the Power Consumption section. See
Figure 6 through Figure 8 for information on per-channel supply current as a function of data rate for unloaded and loaded conditions. See Figure 9 through Figure 11
for total IDD1 and IDD2 supply currents as a function of data rate for ADuM1200W and ADuM1201W channel configurations.
2
The minimum pulse width is the shortest pulse width at which the specified pulse width distortion is guaranteed.
3
The maximum data rate is the fastest data rate at which the specified pulse width distortion is guaranteed.
4
tPHL propagation delay is measured from the 50% level of the falling edge of the VIx signal to the 50% level of the falling edge of the VOx signal. tPLH propagation delay is
measured from the 50% level of the rising edge of the VIx signal to the 50% level of the rising edge of the VOx signal.
5
tPSK is the magnitude of the worst-case difference in tPHL and/or tPLH that is measured between units at the same operating temperature, supply voltages, and output
load within the recommended operating conditions.
6
Codirectional channel-to-channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on the same side of
the isolation barrier. Opposing directional channel-to-channel matching is the absolute value of the difference in propagation delays between any two channels with
inputs on opposing sides of the isolation barrier.
7
CMH is the maximum common-mode voltage slew rate that can be sustained while maintaining VO > 0.8 VDD2. CML is the maximum common-mode voltage slew rate
that can be sustained while maintaining VO < 0.8 V. The common-mode voltage slew rates apply to both rising and falling common-mode voltage edges. The transient
magnitude is the range over which the common mode is slewed.
8
Dynamic supply current is the incremental amount of supply current required for a 1 Mbps increase in the signal data rate. See Figure 6 through Figure 8 for
information on per-channel supply current as a function of data rate for unloaded and loaded conditions. See the Power Consumption section for guidance on
calculating per-channel supply current for a given data rate.
Rev. I | Page 16 of 28
Data Sheet
ADuM1200/ADuM1201
ELECTRICAL CHARACTERISTICS—MIXED 3 V/5 V, 125°C OPERATION
All voltages are relative to their respective ground; 3.0 V ≤ VDD1 ≤ 3.6 V, 4.5 V ≤ VDD2 ≤ 5.5 V; all minimum/maximum specifications apply
over the entire recommended operating range, unless otherwise noted; all typical specifications are at TA = 25°C; VDD1 = 3.0 V, VDD2 = 5.0 V;
this applies to ADuM1200W and ADuM1201W automotive grade products.
Table 7.
Parameter
DC SPECIFICATIONS
Input Supply Current per Channel,
Quiescent
Output Supply Current per Channel,
Quiescent
ADuM1200W, Total Supply Current,
Two Channels1
DC to 2 Mbps
VDD1 Supply Current
VDD2 Supply Current
10 Mbps (TRZ and URZ Grades Only)
VDD1 Supply Current
VDD2 Supply Current
25 Mbps (URZ Grade Only)
VDD1 Supply Current
VDD2 Supply Current
ADuM1201W, Total Supply Current,
Two Channels1
DC to 2 Mbps
VDD1 Supply Current
VDD2 Supply Current
10 Mbps (TRZ and URZ Grades Only)
VDD1 Supply Current
VDD2 Supply Current
25 Mbps (URZ Grade Only)
VDD1 Supply Current
VDD2 Supply Current
For All Models
Input Currents
Logic High Input Threshold
Logic Low Input Threshold
Logic High Output Voltages
Logic Low Output Voltages
SWITCHING SPECIFICATIONS
ADuM120xWSRZ
Minimum Pulse Width2
Maximum Data Rate3
Propagation Delay4
Pulse Width Distortion, |tPLH − tPHL|4
Propagation Delay Skew5
Channel-to-Channel Matching6
Output Rise/Fall Time (10% to 90%)
Symbol
Typ
Max
Unit
IDDI (Q)
0.26
0.35
mA
IDDO (Q)
0.19
0.25
mA
IDD1 (Q)
IDD2 (Q)
0.6
0.5
1.0
0.8
mA
mA
DC to 1 MHz logic signal freq.
DC to 1 MHz logic signal freq.
IDD1 (10)
IDD2 (10)
2.2
1.3
3.4
2.0
mA
mA
5 MHz logic signal freq.
5 MHz logic signal freq.
IDD1 (25)
IDD2 (25)
5.2
2.8
7.7
3.4
mA
mA
12.5 MHz logic signal freq.
12.5 MHz logic signal freq.
IDD1 (Q)
IDD2 (Q)
0.4
0.8
0.8
1.1
mA
mA
DC to 1 MHz logic signal freq.
DC to 1 MHz logic signal freq.
IDD1 (10)
IDD2 (10)
1.5
2.8
2.2
3.5
mA
mA
5 MHz logic signal freq.
5 MHz logic signal freq.
IDD1 (25)
IDD2 (25)
3.4
6.3
4.8
8.0
mA
mA
12.5 MHz logic signal freq.
12.5 MHz logic signal freq.
−10
0.7 (VDD1 or VDD2)
+0.01
+10
0 V ≤ VIA, VIB ≤ (VDD1 or VDD2)
(VDD1 or VDD2) − 0.1
(VDD1 or VDD2) − 0.5
VDD1 or VDD2
(VDD1 or VDD2) − 0.2
0.0
0.04
0.2
μA
V
V
V
V
V
V
V
IIA, IIB
VIH
VIL
VOAH, VOBH
Min
0.3 (VDD1 or VDD2)
VOAL, VOBL
0.1
0.1
0.4
Test Conditions
IOx = −20 μA, VIx = VIxH
IOx = −4 mA, VIx = VIxH
IOx = 20 μA, VIx = VIxL
IOx = 400 μA, VIx = VIxL
IOx = 4 mA, VIx = VIxL
CL = 15 pF, CMOS signal levels
PW
tPHL, tPLH
PWD
tPSK
tPSKCD/
tPSKOD
tR/tF
1000
1
15
3
Rev. I | Page 17 of 28
150
40
ns
Mbps
ns
ns
50
50
ns
ns
ns
ADuM1200/ADuM1201
Parameter
Data Sheet
Symbol
ADuM120xWTRZ
Minimum Pulse Width2
Max
Unit
Typ
100
ns
55
ns
3
ns
tPSK
22
ps/°C
ns
tPSKCD
3
ns
tPSKOD
22
Test Conditions
CL = 15 pF, CMOS signal levels
PW
Maximum Data Rate3
Propagation Delay
Min
10
4
tPHL, tPLH
Pulse Width Distortion, |tPLH − tPHL|4
Change vs. Temperature
Propagation Delay Skew5
Channel-to-Channel Matching
Codirectional Channels6
Opposing Directional Channels6
Output Rise/Fall Time (10% to 90%)
ADuM120xWURZ
Minimum Pulse Width2
PWD
5
tR/tF
2.5
PW
20
CL = 15 pF, CMOS signal levels
ns
50
ns
3
ns
tPSK
15
ps/°C
ns
tPSKCD
3
ns
25
Propagation Delay4
tPHL, tPLH
Pulse Width Distortion, |tPLH − tPHL|4
Change vs. Temperature
Propagation Delay Skew5
Channel-to-Channel Matching
Codirectional Channels6
PWD
Opposing Directional Channels
Output Rise/Fall Time (10% to 90%)
For All Models
Common-Mode Transient Immunity
Logic High Output7
Logic Low Output7
Refresh Rate
Input Dynamic Supply Current
per Channel8
Output Dynamic Supply Current
per Channel8
ns
ns
40
Maximum Data Rate3
6
Mbps
15
50
20
Mbps
5
tPSKOD
15
tR/tF
ns
2.5
ns
|CMH|
25
35
kV/μs
|CML|
25
35
kV/μs
fr
IDDI (D)
1.1
0.10
IDDO (D)
0.05
Mbps
mA/
Mbps
mA/
Mbps
1
VIx = VDD1, VDD2, VCM = 1000 V,
transient magnitude = 800 V
VIx = 0 V, VCM = 1000 V,
transient magnitude = 800 V
The supply current values are for both channels combined when running at identical data rates. Output supply current values are specified with no output load
present. The supply current associated with an individual channel operating at a given data rate can be calculated as described in the Power Consumption section. See
Figure 6 through Figure 8 for information on per-channel supply current as a function of data rate for unloaded and loaded conditions. See Figure 9 through Figure 11
for total IDD1 and IDD2 supply currents as a function of data rate for ADuM1200W and ADuM1201W channel configurations.
2
The minimum pulse width is the shortest pulse width at which the specified pulse width distortion is guaranteed.
3
The maximum data rate is the fastest data rate at which the specified pulse width distortion is guaranteed.
4
tPHL propagation delay is measured from the 50% level of the falling edge of the VIx signal to the 50% level of the falling edge of the VOx signal. tPLH propagation delay is
measured from the 50% level of the rising edge of the VIx signal to the 50% level of the rising edge of the VOx signal.
5
tPSK is the magnitude of the worst-case difference in tPHL and/or tPLH that is measured between units at the same operating temperature, supply voltages, and output
load within the recommended operating conditions.
6
Codirectional channel-to-channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on the same side of
the isolation barrier. Opposing directional channel-to-channel matching is the absolute value of the difference in propagation delays between any two channels with
inputs on opposing sides of the isolation barrier.
7
CMH is the maximum common-mode voltage slew rate that can be sustained while maintaining VO > 0.8 VDD2. CML is the maximum common-mode voltage slew rate
that can be sustained while maintaining VO < 0.8 V. The common-mode voltage slew rates apply to both rising and falling common-mode voltage edges. The transient
magnitude is the range over which the common mode is slewed.
8
Dynamic supply current is the incremental amount of supply current required for a 1 Mbps increase in the signal data rate. See Figure 6 through Figure 8 for
information on per-channel supply current as a function of data rate for unloaded and loaded conditions. See the Power Consumption section for guidance on
calculating per-channel supply current for a given data rate.
Rev. I | Page 18 of 28
Data Sheet
ADuM1200/ADuM1201
PACKAGE CHARACTERISTICS
Table 8.
Parameter
Resistance (Input-to-Output)1
Capacitance (Input-to-Output)1
Input Capacitance
IC Junction-to-Case Thermal Resistance, Side 1
Symbol
RI-O
CI-O
CI
θJCI
IC Junction-to-Case Thermal Resistance, Side 2
θJCO
1
Min
Typ
1012
1.0
4.0
46
41
Max
Unit
Ω
pF
pF
°C/W
Test Conditions
f = 1 MHz
Thermocouple located at
center of package underside
°C/W
The device is considered a 2-terminal device; Pin 1, Pin, 2, Pin 3, and Pin 4 are shorted together, and Pin 5, Pin 6, Pin 7, and Pin 8 are shorted together.
REGULATORY INFORMATION
The ADuM1200/ADuM1201 and ADuM1200W/ADuM1201W are approved by the organizations listed in Table 9; refer to Table 14 and
the Insulation Lifetime section for details regarding recommended maximum working voltages for specific cross-isolation waveforms and
insulation levels.
Table 9.
UL
Recognized Under 1577 Component
Recognition Program1
Single/Basic 2500 V rms Isolation Voltage
File E214100
1
2
CSA
Approved under CSA Component Acceptance
Notice #5A; approval pending for ADuM1200W/
ADuM1201W automotive 125°C temperature grade
Basic insulation per CSA 60950-1-03 and
IEC 60950-1, 400 V rms (566 peak) maximum
working voltage
Functional insulation per CSA 60950-1-03 and
IEC 60950-1, 800 V rms (1131 V peak) maximum
working voltage
File 205078
VDE
Certified according to DIN V VDE V
0884-10 (VDE V 0884-10): 2006-122
Reinforced insulation, 560 V peak
File 2471900-4880-0001
In accordance with UL 1577, each ADuM120x is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection limit = 5 μA).
In accordance with DIN V VDE V 0884-10, each ADuM120x is proof tested by applying an insulation test voltage ≥ 1050 V peak for 1 sec (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 10.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Symbol
L(I01)
Value
2500
4.90 min
Unit
V rms
mm
Minimum External Tracking (Creepage)
L(I02)
4.01 min
mm
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
CTI
0.017 min
>175
IIIa
mm
V
Rev. I | Page 19 of 28
Conditions
1 minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
ADuM1200/ADuM1201
Data Sheet
DIN V VDE V 0884-10 (VDE V 0884-10): 2006-12 INSULATION CHARACTERISTICS
This isolator is suitable for reinforced isolation only within the safety limit data. Maintenance of the safety data is ensured by protective
circuits. Note that the asterisk (*) marking on the package denotes DIN V VDE V 0884-10 approval for a 560 V peak working voltage.
Table 11.
Description
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method B1
Input-to-Output Test Voltage, Method A
After Environmental Tests Subgroup 1
After Input and/or Safety Test Subgroup 2
and Subgroup 3
Highest Allowable Overvoltage
Safety-Limiting Values
Case Temperature
Side 1 Current
Side 2 Current
Insulation Resistance at TS
Conditions
VIORM × 1.875 = VPR, 100% production test,
tm = 1 second, partial discharge < 5 pC
VIORM × 1.6 = VPR, tm = 60 seconds,
partial discharge < 5 pC
VIORM × 1.2 = VPR, tm = 60 seconds,
partial discharge < 5 pC
Transient overvoltage, tTR = 10 seconds
Maximum value allowed in the event of a failure
(see Figure 3)
VIO = 500 V
Symbol
Characteristic
Unit
VIORM
VPR
I to IV
I to III
I to II
40/105/21
2
560
1050
V peak
V peak
896
672
V peak
V peak
VTR
4000
V peak
TS
IS1
IS2
RS
150
160
170
>109
°C
mA
mA
Ω
VPR
RECOMMENDED OPERATING CONDITIONS
200
Table 12.
SAFETY-LIMITING CURRENT (mA)
180
80
Parameter
Operating Temperature (TA) 1
Operating Temperature (TA) 2
Supply Voltages (VDD1, VDD2)1, 3
Supply Voltages (VDD1, VDD2)2, 3
Input Signal Rise and Fall Times
60
1
160
140
SIDE #2
SIDE #1
120
100
40
0
0
50
100
150
CASE TEMPERATURE (°C)
200
04642-003
20
Rating
−40°C to +105°C
−40°C to +125°C
2.7 V to 5.5 V
3.0 V to 5.5 V
1.0 ms
Does not apply to ADuM1200W and ADuM1201W automotive grade
products.
2
Applies to ADuM1200W and ADuM1201W automotive grade products.
3
All voltages are relative to their respective ground. See the DC Correctness
and Magnetic Field Immunity section for information on immunity to external
magnetic fields.
Figure 3. Thermal Derating Curve, Dependence of Safety-Limiting Values
on Case Temperature per DIN V VDE V 0884-10
Rev. I | Page 20 of 28
Data Sheet
ADuM1200/ADuM1201
ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Table 13.
Parameter
Storage Temperature (TST)
Ambient Operating Temperature (TA) 1
Ambient Operating Temperature (TA) 2
Supply Voltages (VDD1, VDD2) 3
Input Voltages (VIA, VIB)3, 4
Output Voltages (VOA, VOB)3, 4
Average Output Current per Pin (IO) 5
Common-Mode Transients (CML, CMH)6
Rating
−55°C to +150°C
−40°C to +105°C
−40°C to +125°C
−0.5 V to +7.0 V
−0.5 V to VDDI + 0.5 V
−0.5 V to VDDO + 0.5 V
−11 mA to +11 mA
−100 kV/μs to +100 kV/μs
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION
1
Does not apply to ADuM1200W and ADuM1200W automotive grade
products.
2
Applies to ADuM1200W and ADuM1201W automotive grade products.
3
All voltages are relative to their respective ground.
4
VDDI and VDDO refer to the supply voltages on the input and output sides of a
given channel, respectively.
5
See Figure 3 for maximum rated current values for various temperatures.
6
Refers to common-mode transients across the insulation barrier.
Common-mode transients exceeding the absolute maximum ratings
can cause latch-up or permanent damage.
Table 14. Maximum Continuous Working Voltage1
Parameter
AC Voltage, Bipolar Waveform
AC Voltage, Unipolar Waveform
Functional Insulation
Basic Insulation
DC Voltage
Functional Insulation
Basic Insulation
1
Max
565
Unit
V peak
Constraint
50-year minimum lifetime
1131
560
V peak
V peak
Maximum approved working voltage per IEC 60950-1
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
1131
560
V peak
V peak
Maximum approved working voltage per IEC 60950-1
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
Refers to continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more details.
Rev. I | Page 21 of 28
ADuM1200/ADuM1201
Data Sheet
VIA 2
VIB 3
ADuM1200
TOP VIEW
(Not to Scale)
GND1 4
8 VDD2
VDD1 1
7 VOA
VOA 2
6 VOB
VIB 3
5 GND2
04642-004
VDD1 1
ADuM1201
TOP VIEW
(Not to Scale)
GND1 4
Figure 4. ADuM1200 Pin Configuration
8
VDD2
7
VIA
6
VOB
5
GND2
04642-005
PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS
Figure 5. ADuM1201 Pin Configuration
Table 15. ADuM1200 Pin Function Descriptions
Table 16. ADuM1201 Pin Function Descriptions
Pin
No.
1
2
3
4
5
6
7
8
Pin
No.
1
2
3
4
5
6
7
8
Mnemonic
VDD1
VIA
VIB
GND1
GND2
VOB
VOA
VDD2
Description
Supply Voltage for Isolator Side 1.
Logic Input A.
Logic Input B.
Ground 1. Ground Reference for Isolator Side 1.
Ground 2. Ground Reference for Isolator Side 2.
Logic Output B.
Logic Output A.
Supply Voltage for Isolator Side 2.
Mnemonic
VDD1
VOA
VIB
GND1
GND2
VOB
VIA
VDD2
Description
Supply Voltage for Isolator Side 1.
Logic Output A.
Logic Input B.
Ground 1. Ground Reference for Isolator Side 1.
Ground 2. Ground Reference for Isolator Side 2.
Logic Output B.
Logic Input A.
Supply Voltage for Isolator Side 2.
Table 17. ADuM1200 Truth Table (Positive Logic)
VIA Input
H
L
H
L
X
VIB Input
H
L
L
H
X
VDD1 State
Powered
Powered
Powered
Powered
Unpowered
VDD2 State
Powered
Powered
Powered
Powered
Powered
VOA Output
H
L
H
L
H
VOB Output
H
L
L
H
H
X
X
Powered
Unpowered
Indeterminate
Indeterminate
Notes
Outputs return to the input state within
1 μs of VDDI power restoration.
Outputs return to the input state within
1 μs of VDDO power restoration.
Table 18. ADuM1201 Truth Table (Positive Logic)
VIA Input
H
L
H
L
X
VIB Input
H
L
L
H
X
VDD1 State
Powered
Powered
Powered
Powered
Unpowered
VDD2 State
Powered
Powered
Powered
Powered
Powered
VOA Output
H
L
H
L
Indeterminate
VOB Output
H
L
L
H
H
X
X
Powered
Unpowered
H
Indeterminate
Rev. I | Page 22 of 28
Notes
Outputs return to the input state within
1 μs of VDDI power restoration.
Outputs return to the input state within
1 μs of VDDO power restoration.
Data Sheet
ADuM1200/ADuM1201
TYPICAL PERFORMANCE CHARACTERISTICS
10
20
15
CURRENT (mA)
CURRENT/CHANNEL (mA)
8
6
4
5V
3V
10
5V
5
2
0
10
20
DATA RATE (Mbps)
30
0
04642-006
0
0
30
Figure 9. Typical ADuM1200 VDD1 Supply Current vs. Data Rate
for 5 V and 3 V Operation
4
3
3
CURRENT (mA)
4
2
5V
1
2
5V
3V
1
0
0
10
20
DATA RATE (Mbps)
30
0
0
Figure 7. Typical Output Supply Current per Channel vs. Data Rate
for 5 V and 3 V Operation (No Output Load)
10
20
DATA RATE (Mbps)
30
04642-010
3V
04642-007
CURRENT/CHANNEL (mA)
Figure 6. Typical Input Supply Current per Channel vs. Data Rate
for 5 V and 3 V Operation
10
20
DATA RATE (Mbps)
04642-009
3V
Figure 10. Typical ADuM1200 VDD2 Supply Current vs. Data Rate
for 5 V and 3 V Operation
4
10
CURRENT (mA)
5V
2
6
5V
4
3V
3V
1
0
0
10
20
DATA RATE (Mbps)
30
Figure 8. Typical Output Supply Current per Channel vs. Data Rate
for 5 V and 3 V Operation (15 pF Output Load)
0
0
10
20
DATA RATE (Mbps)
30
04642-011
2
04642-008
CURRENT/CHANNEL (mA)
8
3
Figure 11. Typical ADuM1201 VDD1 or VDD2 Supply Current vs. Data Rate
for 5 V and 3 V Operation
Rev. I | Page 23 of 28
ADuM1200/ADuM1201
Data Sheet
APPLICATIONS INFORMATION
PCB LAYOUT
The ADuM120x are extremely immune to external magnetic
fields. The limitation on the magnetic field immunity of the
ADuM120x is set by the condition in which induced voltage in
the receiving coil of the transformer is sufficiently large enough
to either falsely set or reset the decoder. The following analysis
defines the conditions under which this can occur. The 3 V
operating condition of the ADuM120x is examined because
it represents the most susceptible mode of operation.
The ADuM120x digital isolators require no external interface
circuitry for the logic interfaces. Power supply bypassing is
strongly recommended at the input and output supply pins.
The capacitor value should be between 0.01 μF and 0.1 μF.
The total lead length between both ends of the capacitor and
the input power supply pin should not exceed 20 mm.
See the AN-1109 Application Note for board layout guidelines.
PROPAGATION DELAY-RELATED PARAMETERS
Propagation delay is a parameter that describes the time it takes
a logic signal to propagate through a component. The propagation
delay to a logic low output can differ from the propagation delay
to a logic high output.
INPUT (VIx)
50%
OUTPUT (VOx)
tPHL
04642-012
tPLH
50%
The pulses at the transformer output have an amplitude greater
than 1.0 V. The decoder has a sensing threshold at about 0.5 V,
therefore establishing a 0.5 V margin in which induced voltages
can be tolerated. The voltage induced across the receiving coil is
given by
V = (−dβ/dt)Σ∏rn2; n = 1, 2, … , N
where:
β is the magnetic flux density (gauss).
N is the number of turns in the receiving coil.
rn is the radius of the nth turn in the receiving coil (cm).
Given the geometry of the receiving coil in the ADuM120x and
an imposed requirement that the induced voltage be 50% at
most of the 0.5 V margin at the decoder, a maximum allowable
magnetic field is calculated, as shown in Figure 13.
Figure 12. Propagation Delay Parameters
Pulse width distortion is the maximum difference between
these two propagation delay values and is an indication of
how accurately the timing of the input signal is preserved.
DC CORRECTNESS AND MAGNETIC FIELD IMMUNITY
Positive and negative logic transitions at the isolator input send
narrow (~1 ns) pulses to the decoder via the transformer. The
decoder is bistable and is therefore either set or reset by the pulses,
indicating input logic transitions. In the absence of logic transitions of more than ~1 μs at the input, a periodic set of refresh
pulses indicative of the correct input state is sent to ensure dc
correctness at the output. If the decoder receives no internal
pulses for more than about 5 μs, the input side is assumed to be
unpowered or nonfunctional, in which case the isolator output
is forced to a default state (see Table 17 and Table 18) by the
watchdog timer circuit.
Rev. I | Page 24 of 28
10
1
0.1
0.01
0.001
1k
10k
100k
1M
10M
MAGNETIC FIELD FREQUENCY (Hz)
100M
Figure 13. Maximum Allowable External Magnetic Flux Density
04642-013
Propagation delay skew refers to the maximum amount that
the propagation delay differs between multiple ADuM120x
components operating under the same conditions.
MAXIMUM ALLOWABLE MAGNETIC FLUX
DENSITY (kgauss)
100
Channel-to-channel matching refers to the maximum amount
that the propagation delay differs between channels within a
single ADuM120x component.
Data Sheet
ADuM1200/ADuM1201
For example, at a magnetic field frequency of 1 MHz, the
maximum allowable magnetic field of 0.2 kgauss induces a
voltage of 0.25 V at the receiving coil. This is about 50% of the
sensing threshold and does not cause a faulty output transition.
Similarly, if such an event occurs during a transmitted pulse
(and has the worst-case polarity), it reduces the received pulse
from >1.0 V to 0.75 V—still well above the 0.5 V sensing
threshold of the decoder.
The preceding magnetic flux density values correspond to
specific current magnitudes at given distances away from the
ADuM120x transformers. Figure 14 expresses these allowable
current magnitudes as a function of frequency for selected
distances. As seen, the ADuM120x are extremely immune and
can be affected only by extremely large currents operating very
close to the component at a high frequency. For the 1 MHz
example, a 0.5 kA current would have to be placed 5 mm away
from the ADuM120x to affect the operation of the component.
DISTANCE = 1m
100
10
DISTANCE = 100mm
1
DISTANCE = 5mm
0.1
0.01
1k
10k
100k
1M
10M
MAGNETIC FIELD FREQUENCY (Hz)
100M
04642-014
MAXIMUM ALLOWABLE CURRENT (kA)
1000
Figure 14. Maximum Allowable Current for Various
Current-to-ADuM120x Spacings
POWER CONSUMPTION
The supply current at a given channel of the ADuM120x
isolator is a function of the supply voltage, the data rate of the
channel, and the output load of the channel.
For each input channel, the supply current is given by
IDDI = IDDI (Q)
f ≤ 0.5fr
IDDI = IDDI (D) × (2f − fr) + IDDI (Q)
f > 0.5fr
For each output channel, the supply current is given by
IDDO = IDDO (Q)
f ≤ 0.5fr
−3
IDDO = (IDDO (D) + (0.5 × 10 ) × CLVDDO) × (2f − fr) + IDDO (Q)
f > 0.5fr
where:
IDDI (D), IDDO (D) are the input and output dynamic supply currents
per channel (mA/Mbps).
CL is the output load capacitance (pF).
VDDO is the output supply voltage (V).
f is the input logic signal frequency (MHz, half of the input data
rate, NRZ signaling).
fr is the input stage refresh rate (Mbps).
IDDI (Q), IDDO (Q) are the specified input and output quiescent
supply currents (mA).
To calculate the total IDD1 and IDD2 supply currents, the supply
currents for each input and output channel corresponding to
IDD1 and IDD2 are calculated and totaled. Figure 6 and Figure 7
provide per-channel supply currents as a function of data rate
for an unloaded output condition. Figure 8 provides perchannel supply current as a function of data rate for a 15 pF
output condition. Figure 9 through Figure 11 provide total
VDD1 and VDD2 supply current as a function of data rate for
ADuM1200 and ADuM1201 channel configurations.
Note that, at combinations of strong magnetic fields and high
frequencies, any loops formed by PCB traces can induce sufficiently large error voltages to trigger the threshold of succeeding
circuitry. Care should be taken in the layout of such traces to
avoid this possibility.
Rev. I | Page 25 of 28
ADuM1200/ADuM1201
Data Sheet
All insulation structures eventually break down when subjected
to voltage stress over a sufficiently long period. The rate of insulation degradation is dependent on the characteristics of the
voltage waveform applied across the insulation. In addition
to the testing performed by the regulatory agencies, Analog
Devices carries out an extensive set of evaluations to determine
the lifetime of the insulation structure within the ADuM120x.
Analog Devices performs accelerated life testing using voltage
levels higher than the rated continuous working voltage. Acceleration factors for several operating conditions are determined.
These factors allow calculation of the time to failure at the actual
working voltage. The values shown in Table 14 summarize the
peak voltage for 50 years of service life for a bipolar ac operating
condition and the maximum CSA/VDE approved working voltages. In many cases, the approved working voltage is higher than
the 50-year service life voltage. Operation at these high working
voltages can lead to shortened insulation life in some cases.
In the case of unipolar ac or dc voltage, the stress on the insulation is significantly lower, which allows operation at higher
working voltages yet still achieves a 50-year service life. The
working voltages listed in Table 14 can be applied while maintaining the 50-year minimum lifetime provided the voltage
conforms to either the unipolar ac or dc voltage cases. Any crossinsulation voltage waveform that does not conform to Figure 16
or Figure 17 is to be treated as a bipolar ac waveform, and its
peak voltage is to be limited to the 50-year lifetime voltage value
listed in Table 14.
Note that the voltage presented in Figure 16 is shown as sinusoidal for illustration purposes only. It is meant to represent any
voltage waveform varying between 0 V and some limiting value.
The limiting value can be positive or negative, but the voltage
cannot cross 0 V.
RATED PEAK VOLTAGE
04642-021
INSULATION LIFETIME
0V
Figure 15. Bipolar AC Waveform
The insulation lifetime of the ADuM120x depends on the
voltage waveform type imposed across the isolation barrier.
The iCoupler insulation structure degrades at different rates
depending on whether the waveform is bipolar ac, unipolar
ac, or dc. Figure 15, Figure 16, and Figure 17 illustrate these
different isolation voltage waveforms, respectively.
04642-022
RATED PEAK VOLTAGE
0V
Figure 16. Unipolar AC Waveform
RATED PEAK VOLTAGE
04642-023
Bipolar ac voltage is the most stringent environment. The goal
of a 50-year operating lifetime under the ac bipolar condition
determines the Analog Devices recommended maximum
working voltage.
0V
Figure 17. DC Waveform
Rev. I | Page 26 of 28
Data Sheet
ADuM1200/ADuM1201
OUTLINE DIMENSIONS
5.00 (0.1968)
4.80 (0.1890)
1
5
6.20 (0.2441)
5.80 (0.2284)
4
1.27 (0.0500)
BSC
0.25 (0.0098)
0.10 (0.0040)
COPLANARITY
0.10
SEATING
PLANE
1.75 (0.0688)
1.35 (0.0532)
0.51 (0.0201)
0.31 (0.0122)
0.50 (0.0196)
0.25 (0.0099)
45°
8°
0°
0.25 (0.0098)
0.17 (0.0067)
1.27 (0.0500)
0.40 (0.0157)
COMPLIANT TO JEDEC STANDARDS MS-012-AA
CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN.
012407-A
8
4.00 (0.1574)
3.80 (0.1497)
Figure 18. 8-Lead Standard Small Outline Package [SOIC_N]
Narrow Body (R-8)
Dimensions shown in millimeters and (inches)
ORDERING GUIDE
Model1, 2
ADuM1200AR
ADuM1200ARZ
ADuM1200ARZ-RL7
ADuM1200BR
ADuM1200BR-RL7
ADuM1200BRZ
ADuM1200BRZ-RL7
ADuM1200CR
ADuM1200CR-RL7
ADuM1200CRZ
ADuM1200CRZ-RL7
ADuM1200WSRZ
ADuM1200WSRZ-RL7
ADuM1200WTRZ
ADuM1200WTRZ-RL7
ADuM1200WURZ
ADuM1200WURZ-RL7
ADuM1201AR
ADuM1201AR-RL7
ADuM1201ARZ
ADuM1201ARZ-RL7
ADuM1201BR
ADuM1201BR-RL7
ADuM1201BRZ
ADuM1201BRZ-RL7
ADuM1201CR
ADuM1201CRZ
ADuM1201CRZ-RL7
Number
of Inputs,
VDD1 Side
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
Number
of Inputs,
VDD2 Side
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
Maximum
Data Rate
(Mbps)
1
1
1
10
10
10
10
25
25
25
25
1
1
10
10
25
25
1
1
1
1
10
10
10
10
25
25
25
Maximum
Propagation
Delay, 5 V (ns)
150
150
150
50
50
50
50
45
45
45
45
150
150
50
50
45
45
150
150
150
150
50
50
50
50
45
45
45
Rev. I | Page 27 of 28
Maximum
Pulse Width
Distortion (ns)
40
40
40
3
3
3
3
3
3
3
3
40
40
3
3
3
3
40
40
40
40
3
3
3
3
3
3
3
Temperature
Range
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
Package
Option3
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
ADuM1200/ADuM1201
Model1, 2
ADuM1201WSRZ
ADuM1201WSRZ-RL7
ADuM1201WTRZ
ADuM1201WTRZ-RL7
ADuM1201WURZ
ADuM1201WURZ-RL7
Number
of Inputs,
VDD1 Side
1
1
1
1
1
1
Data Sheet
Number
of Inputs,
VDD2 Side
1
1
1
1
1
1
Maximum
Data Rate
(Mbps)
1
1
10
10
25
25
Maximum
Propagation
Delay, 5 V (ns)
150
150
50
50
45
45
Maximum
Pulse Width
Distortion (ns)
40
40
3
3
3
3
Temperature
Range
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
Package
Option3
R-8
R-8
R-8
R-8
R-8
R-8
1
Z = RoHS Compliant Part.
W = Qualified for Automotive Applications.
3
R-8 = 8-lead narrow-body SOIC_N.
2
AUTOMOTIVE PRODUCTS
The ADuM1200W/ADuM1201W models are available with controlled manufacturing to support the quality and reliability requirements
of automotive applications. Note that these automotive models may have specifications that differ from the commercial models; therefore,
designers should review the Specifications section of this data sheet carefully. Only the automotive grade products shown are available for
use in automotive applications. Contact your local Analog Devices account representative for specific product ordering information and
to obtain the specific Automotive Reliability reports for these models.
©2004–2012 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D04642-0-3/12(I)
Rev. I | Page 28 of 28
Similar pages