Emerson Network Power LPQ110 Universal input Datasheet

110 Watts
LPQ110 Series
Total Power: 80-110 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs: Quad
Electrical Specs
Input
Input range
Frequency
Inrush current
Input current
Efficiency
EMI filter
Special Features
•
•
•
•
•
•
•
•
•
Universal input
High efficiency
Remote sense on main output
Built-in EMI filter
Low output ripple
Adjustable 5 V output
Overvoltage protection
Overload protection
Adjustable floating 4th output
(On LPQ112 and LPQ113)
• Power fail
• Optional L bracket (-B suffix)
• Cover kit available LPX110-C
Environmental
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from 50°
to 70°C
Safety ground
leakage current
Maximum power
Adjustment range
Cross regulation
Hold-up time
Overload protection
Overvoltage protection
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditions
80 W for convection;
110 W with 30 CFM forced air
±5% min. on main; 5-25 V on 4th
output on LPQ112 and LPQ113
±2% on output 1; ±3% on outputs
2, 3 & 4
20 ms @ 80 W load, 115 VAC
nominal line
Short circuit protection on all
outputs. Case overload protected @
110-145% above peak rating
5.7-6.7 VDC on main output.
Latching type, recycle AC to reset.
Logic Control
Power Failure
Remote sense
Humidity: Operating; non-condensing
5% to 95%
Storage temperature: -40° to 85°C
<0.5 mA @ 50/60 Hz, 264 VAC input
Output
Electromagnetic susceptibility: Designed to
meet IEC 801, -2, -3, -4, -5, -6, Level 3
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.75 G peak 5 Hz to 500 Hz, operational
85-264 VAC
120-300 VDC
47-440 Hz
<18 A peak @ 115 VAC;
<36 A peak @ 230 VAC,
cold start @ 25°C
2.5 A max. (RMS) @ 115 VAC
70% typical at full load
FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
TTL logic signal goes high 50-150
msec after 5 V output. It goes low at
least 4 msec before loss of regulation.
Compensates for 0.5 V lead drop
min. Will operate without remote
sense connected. Reverse
connection protected.
Electrical Specs
VDE
UL
CSA
NEMKO
CB
CE
0805/EN60950 (IEC950)
UL1950
CSA 22.2-234 Level 3
EN 60950/EMKO-TUE
(74-sec) 203
Certificate and report
Mark (LVD)
11774-3336-1245 (LC #84997)
E132002
LR53982C
P94102464
1423, 1424, 1425
rev 12.10.03
102
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Model
Number
Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
30 CFM Forced Air
Peak
Load1
Regulation2
Ripple
P/P (PARD)3
LPQ112
5V
12 V
-12 V
±5-25 V
2A
0A
0A
0A
9A
4.5 A
0.7 A
2.5 A
11 A
5A
1.0 A
3A
15 A
9A
1.5 A
3.5 A
±2%
±3%
±5%
±3%
50 mV
120 mV
120 mV
240 mV, max.
LPQ113
5V
15 V
-15 V
±5-25 V
2A
0A
0A
0A
9A
4.5 A
0.7 A
2.5 A
11 A
5A
1.0 A
3A
15 A
9A
1.5 A
3.5 A
±2%
±3%
±5%
±3%
50 mV
150 mV
150 mV
240 mV, max.
LPQ114
5V
12 V
-12 V
24 V
2A
0A
0A
0.5 A
9A
4.5 A
0.7 A
3.5 A
11 A
5A
1.0 A
4.5 A
15 A
9A
1.5 A
5A
±2%
±3%
±5%
+10 / -5%
50 mV
120 mV
120 mV
240 mV
LPQ110 Series
Ordering Information
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. 4th O/P adjustable 5 to 25 V, factory set at 5 V.
5. Minimum loads are required.
Note: -B suffix added to model number indicates L bracket option.
-B Bracket
Connector LPQ112
LPQ113
LPQ114
SK1-1
SK1-3
SK1-5
GND
Neutral
Line
GND
Neutral
Line
GND
Neutral
Line
SK2-1
SK2-2
SK2-3
SK2-4
SK2-5
SK2-6
SK2-7
SK2-8
SK2-9
SK2-10
SK2-11
SK2-12
SK201-1
SK201-2
SK202-1
SK202-2
+5 V
+5 V
+5 V
Common
Common
Common
Common
+12 V
+12 V
-12 V
+5-25 V
-5-25 V
+sense
-sense
POK
GND
+5 V
+5 V
+5 V
Common
Common
Common
Common
+15 V
+15 V
-15 V
+5-25 V
-5-25 V
+sense
-sense
POK
GND
+5 V
+5 V
+5 V
Common
Common
Common
Common
+12 V
+12 V
-12 V
+24 V
Common
+sense
-sense
POK
GND
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ± 0.02”
3. Specifications are for convection rating at factory settings unless otherwise stated.
4. Mounting holes M1 and M2 should be grounded for EMI purposes.
5. Mounting hole M1 is safety ground connection.
6. L bracket mounting (6-32) maximum insertion depth is .20” (5).
7. Warranty: 1 year
8. Weight: 1.25 lb./0.57 kg
2.5"
(63.5)
6.4"
(162.6)
7.3"
(185.5)
2.2"
(56)
0.86"
(21.8)
5.9"
(150.0)
0.25"
(6.35)
M2
4.0"
(101.6)
5V O/P ADJ
Mating Connectors
AC Input:
Molex 09-50-8051 (USA)
09-91-0500 (UK)
PINS: 08-58-0111
DC Outputs: Molex 09-50-8121 (USA)
09-91-1200 (UK)
PINS: 08-58-0111
Remote sense/Power fail:
Molex 22-01-1022 (USA)
22-01-1023 (UK)
PINS: 08-50-0114
Astec Connector Kit #70-841-008, includes all of the above.
#6-32 PEM
6 places
4.28"
(108.6)
3.5"
(88.9)
4th O/P ADJ
1
1
2
3
4
5
6
7
8
9
10
11
12
3
SK 1
6.5"
(165.1)
0.25"
(6.35)
7.0"
(177.8)
SK 201
(+S) 1
(-S) 2
SK 202
(POK)
1 2
SK 2
Pin Assignments
GND
N
L
M1
0.156" (4)
DIA (4 places)
1.80"
(45.7)
0.12"
(3)
www.astecpower.com
103