Aeroflex ACT4436 Act 4436 dual transceiver for mil-std-1553/1760 Datasheet

ACT 4436 DUAL TRANSCEIVER
FOR MIL-STD-1553/1760
Features
CIRCUIT TECHNOLOGY
★ Smaller Case Outline than ACT4487D
www.aeroflex.com/act1.htm
General Description
• +5 / ±15 Volt Supply Operation
• Low Power Dissipation
• Outstanding MIL-STD-1553 performance
• Radiation Hard Dielectric Isolation Monolithic
Construction for Severe Environments
• Input and Output TTL Compatible Design
• Processed and Screened to MIL-STD-883 Specs
• MIL-PRF-38534 Compliant Devices Available
• DESC SMD# 5962-89447
TX DATA OUT
TX DATA IN
DRIVER
TX DATA IN
ACTIVE
FILTER
OUTPUT
STAGE
TX DATA OUT
TX INHIBIT IN
+5V (VL)
+15V (VCC)
-15V (VEE)
RX DATA OUT
REFERENCE
COMP.
ACTIVE
FILTER
COMP.
GND1
GND2
GND3
RX DATA IN
RX DATA IN
INPUT
AMPLIFIER
RX DATA OUT
CASE
RX STROBE IN
Block Diagram (Without Transformer)
The Aeroflex Circuit Technology
ACT 4436 is a next generation
monolithic
transceiver
design
which provides full compliance to
MIL-STD-1553A/B and 1760 requirements in a smaller package
with lower pin count then the
ACT4487D, for those designs with
less board space.
The ACT 4436 series performs
the front-end analog function of
inputting and outputting data
through a transformer to the
MIL-STD-1553 data bus.
Design of this transceiver reflects
particular attention to active filter
performance. This results in low bit
and word error rate with superior
waveform purity and minimal zero
crossover
distortion.
Efficient
transmitter electrical and thermal
design provides low internal power
dissipation and heat rise at high as
well as low duty cycles.
Transmitter:
The Transmitter section accepts
bi-phase TTL data at the input and
when coupled to the data bus with a
1.4:1 ratio transformer, isolated on
the data bus side with two 52.5
Ohm fault isolation resistors, and
loaded
by
two
70
Ohm
terminations, the data bus signal is
typically 7.5 Volts P-P at point A
(See Figure 5). When both DATA
and DATA inputs are held low or
high,
the
transmitter
output
becomes a high impedance and is
“removed” from the line. In addition,
eroflex Circuit Technology – Data Bus Modules For The Future © SCD4436D REV B 3/10/98
an overriding “INHIBIT" input
provides for the removal of the
transmitter output from the line. A
logic “1” signal applied to the
“INHIBIT” takes priority over the
condition of the data inputs and
disables the transmitter (See
Transmitter
Logic
Waveform,
Figure 1). The Transmitter may be
safely operated for an indefinite
period with the bus (point A) short
circuited at 100% duty cycle.
Receiver:
The Receiver section accepts
bi-phase differential data at the
input and produces two TTL signals
at the output. The outputs are DATA
and DATA, and represent positive
and negative excursions of the input
beyond a pre-determined threshold
(See Receiver Logic Waveform,
Figure 2).
The pre-set internal thresholds will
detect data bus signals, point A
Figure 5, exceeding 1.20 Volts
P-P and reject signals less than
0.6 Volts P-P when used with a
transformer (See Figure 5 for
transformer data and typical
connection).
A low level at the RX Strobe
input inhibits the DATA and
DATA outputs. If unused, a 2K
pull-up to +5 Volts
is
recommended.
Figure 1 — Transmitter Logic Waveforms Idealized
DATA IN
DATA IN
INHIBIT
LINE TO LINE
OUTPUT
Note: DATA and DATA inputs must be complementary waveforms or 50% duty cycle average, with no delays between them,
and must be in the same state during off times (both high or low).
Figure 2 — Receiver Logic Waveforms Idealized (ACT4436D)
LINE TO LINE
INPUT
STROBE
DATA OUT
DATA OUT
Note overlap
Aeroflex Circuit Technology
2
SCD4436D REV B 3/10/98/98 Plainview NY (516) 694-6700
Absolute Maximum Ratings
Operating case temperature
-55°C to +125°C
Storage case temperature
-65°C to +150°C
Power supply voltage
VCC
VEE
VL
-0.3 V to +18 V
+0.3 V to-18 V
-0.3 V to +7.0 V
Logic input voltage
-0.3 V to +5.5 V
±40 VP-P
Receiver differential input
Receiver input voltage (common mode)
±10 V
Driver peak output current
300 mA
Total package power dissipation over the full operating case
temperature rise
2.5 Watts
(Note: Normal operation conditions require one
transceiver on and the other off)
Maximum junction to case temperature
10°C
Thermal resistance – junction to case
4°C/W
Electrical Characteristics — Driver Section
I nput Characteristics, TX DATA IN or TX DATA IN (Notes 2 & 3 apply)
Parameter
Condition
"0" Input Current
VIN = 0.4 V
"1" Input Current
VIN = 2.7 V
Symbol
Typ
Max
Unit
IILD
-0.1
-0.2
mA
IIHD
1
40
µA
0.7
V
"0" Input Voltage
VIHD
"1" Input Voltage
VIHD
Min
2.0
V
Inhibit Characteristics
"0" Input Current
"1" Input Current
VIN = 0.4 V
IILI
-0.1
-0.2
VIN=2.7V
IIHI
1.0
40
"0" Input Voltage
VILI
"1" Input Voltage
VIHI
Delay from TX inhibit, (0→1) to inhibited output
Delay from TX inhibit, (1→0) to active output
From mid pt
inhibit to
±1.2V pt B,
See Figure 5
Differential output noise, inhibit mode
Differential output impedance (inhibited) Note 1
See Figure 5
0.7
mA
µA
V
V
2.0
tDXOFF
175
225
tDXON
90
150
VNOI
2
10
nS
nS
mVP-P
Point B
ZOI
2K
Ω
Point C
ZOI
1K
Ω
Point A
VO
6
7.5
9
Point A
tr
100
160
200
nS
Point A
VOS
± 90
mV peak
Point A
tDXT
200
nS
Output Characteristics
Differential output level,
See Figure 5
Rise and fall times(10% to 90% at pt A output)
See Figure 5
Output offset, Figure 3, 2.5µS after midpoint crossing
of the parity bit of the last word of a 660µS message
See Figure 5
Delay from 50% point of TX DATA or TX DATA input
to zero crossing of differential signal. See Fig 5
Aeroflex Circuit Technology
3
100
VP-P
SCD4436D REV B 3/10/98/98 Plainview NY (516) 694-6700
Electrical Characteristics — Receiver Section
Parameter
Differential Receiver Input Voltage Range
(See Figure 5, Point B)
Condition
Symbol
TXFMR
1.4:1
VIDR
Common Mode Rejection Ratio (Note 3)
CMRR
Min
Typ
Max
Unit
40
VP-P
45
dB
"1" State – Rx Data or Rx Data Output
IOH = -0.4 mA
VOH
"0" State – Rx Data or Rx Data Output
IOI = 4 mA
VOL
0.35
0.5
V
tDXT
270
400
nS
0.75
1.15
VP-P
Delay (average) from Differential Input Zero
Crossings to RX DATA and RX DATA Output
50% points
Input Threshold Voltage (referred to the bus)
100KHz–1MHz
VTH
2.5
0.60
3.7
V
Strobe Characteristics (Logic "0" Inhibits Output)
"0" Input Current
VS=0.4V
IIL
-0.1
"1" Input Current
VS=2.7V
IIH
1
-0.2
mA
+40
µA
0.7
V
"0" Input Voltage
VIL
"1" Input Voltage
VIH
Strobe Delay (Turn-on or Turn-off)
tSD
50
100
ICC
IEE
IL
ICC
IEE
IL
ICC
IEE
IL
ICC
IEE
IL
0
12
18
1
16
30
45
12
18
90
12
18
180
12
18
50
20
30
100
20
30
200
20
30
±15V Operating Power Supply Voltage Range
VCC
VEE
+14.25 +15.00 +15.75
-14.25 -15.00 -15.75
V
+5V Operating Power Supply Voltage Range)
VL
+4.50
V
V
2.0
nS
Power Data
Power Supply Currents – Per Channel – See Figure 4
Transmitter Standby
25% duty cycle
50% duty cycle
100% duty cycle
mA
Power Supply Voltages
+5.00
+5.50
Note 1. Power on or off, measured from 75KHz to 1MHz at point A and transformer self impedance of 3KΩ minimum
at 1MHz.
Note 2: Power Supplies: ±15 Volts ±0.75 V & +5 Volts ±0.5 V, bypassed by 10 µF (Tantalum recommended)
Capacitor minimum. All measurements & specifications apply over the temperature range of -55°C to +125°C
(case temperature) unless otherwise specified.
Note 3: When measured as shown per Figure 5 with ± 10 Volt peak, line to ground, DC to 2MHz
Note 4: Typical power is measured with VBUS at point A = 7.5 VP-P
Aeroflex Circuit Technology
4
SCD4436D REV B 3/10/98/98 Plainview NY (516) 694-6700
Figure 3 – Transmitter (TX) Output Offset
Figure 5 – Typical 1553 Bus Connections
LAST BIT
Transformer Coupled Stub
70Ω
Magnified View
ACT 4436
OUTPUT OFFSET
*
OUTPUT OFFSET
*
TX DATA OUT
0 Volts
1:1.4 52.5Ω
2:1
3
7
2
TX DATA OUT
2.5 µsec
C
A
1
5
T1553-2
52.5Ω
RX DATA IN
Zoi
VCM
RX DATA IN
*Offset measured at point A in Figure 5
Direct Coupled Stub
Figure 4 – Hybrid Power Dissipation vs. Duty Cycle
(Total hybrid with one channel transmitting
and the other not powered – 100% Duty Cycle)
ACT 4436
TX DATA OUT
3600
2
3200
52.5Ω
1.4:1
3
8
B
A
POWER DISSIPATION
MILLIWATTS
2.97W
0.270
2800
TX DATA OUT
Typical Hybrid Input Power
2400
1
4
T1553-2
RX DATA IN
2000
52.5Ω
Zoi
1.87W
70Ω
RX DATA IN
1600
1200
800
Typical Hybrid
Dissipation
400
0
0
10
20
30
40
50
60
70
80
Transformer Model use Technitrol Part# 1553-2
or equivalent
90 100
DUTY CYCLE – PERCENT
Note: Vcc= +15V, VEE = -15V, VL= +5V, Transformer ratio 1.4:1,
VBUS (point A) at 7.5VP-P.
Configurations and Ordering Information
ACT
Model # / Ordering Part #
Case
Style
DESC
Number
Rx Standby
ACT 4436-D
Plug In
5962-TBA
Normally Low
ACT 4436-DI
Plug In
5962-8944708HUX
Normally High
ACT 4436-DF
Flat Package
5962-TBA
Normally Low
ACT 4436-DFI
Flat Package
5962-8944708HZX
Normally High
Specifications subject to change without notice.
Aeroflex Circuit Technology
5
SCD4436D REV B 3/10/98/98 Plainview NY (516) 694-6700
Figure 6 – Lead Numbers & Functions
ACT4436D – Plug In and Flat Package
Aeroflex Circuit Technology
Pin #
Function
Channel
1
TX DATA OUT/ RX DATA IN
A
2
TX DATA OUT/ RX DATA IN
A
3
GROUND
A
4
RX STROBE
A
5
RX DATA OUT
A
6
RX DATA OUT
A
7
CASE
A
8
TX DATA OUT/ RX DATA IN
B
9
TX DATA OUT/ RX DATA IN
B
10
GROUND
B
11
RX STROBE
B
12
RX DATA OUT
B
13
RX DATA OUT
B
14
NC
B
15
GROUND
B
16
-V
B
17
VL
B
18
TX INHIBIT
B
19
TX DATA IN
B
20
TX DATA IN
B
21
+V
B
22
GROUND
A
23
-V
A
24
VL
A
25
TX INHIBIT
A
26
TX DATA IN
A
27
TX DATA IN
A
28
+V
A
6
SCD4436D REV B 3/10/98/98 Plainview NY (516) 694-6700
CIRCUIT TECHNOLOGY
Plug In Package Outline
1.480 MAX.
28
15
0.780
MAX.
0.600
Pin 1 & ESD
Designator
14
0.210
MAX.
.250
.018
.100
1.300
(13 Equal Spaces at .100)
Flat Package Outline
.180
MAX.
.072
1.500 MAX.
.015
28
15
0.780
MAX.
Lead 1 & ESD
Designator
14
.400
MIN.
.100
.010
1.300
(13 Equal Spaces at .100)
Telephone: (516) 694-6700
FAX:
(516) 694-6715
Toll Free Inquiries: (800) THE-1553
E-Mail: [email protected]
Aeroflex Circuit Technology
35 South Service Road
Plainview New York 11830
www.aeroflex.com/act1.htm
Aeroflex Circuit Technology
7
SCD4436D REV B 3/10/98 Plainview NY (516) 694-6700
Similar pages